1 In-house Training on ICP-MS. ICP-MS??? Inductively Coupled Plasma Mass Spectrometry or ICP-MS is an analytical technique used for elemental determinations.

Slides:



Advertisements
Similar presentations
FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Advertisements

FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
ACADs (08-006) Covered Keywords analytical balance, conductivity bridge with flow cell, inductively coupled plasma analyzer, in-line sodium monitor, ion.
Mass spectroscopy. In a typical MS procedure:  1- a sample is loaded onto the MS instrument, and undergoes vaporization.  2- the components of the sample.
Elemental Spectroscopy ICP-OES
Ion Sources Some characteristics of ion sources (especially in high precision work): It should have high efficiency in generating ions of the element of.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
Chapter 10 ATOMIC EMISSION SPECTROMETRY
AAS and FES (Ch 10, 7th e, WMDS)
Atomic Emission Spectroscopy
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
IDDepth δ 13 CCarbonNitrogenδ 13 C Depth: (cm)(‰)(%) (‰)(cm) Gr. 3-5A %0.17% Gr %0.12% Gr %0.09%
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Spectroscopy Atomic Spectroscopic Methods Covered in Ch 313: Optical Atomic Spectrometry (Ch 8-10) Atomic X-ray Spectrometry (Ch 12) Atomic Mass.
INTRODUCTION TO OPTICAL METHODS
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Flame photometry.
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Instrumental Chemistry Chapter 11 Atomic Mass Spectrometry.
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
ATOMIC EMISSION SPECTROMETRY Chap 10 Sections: Sections: 10A 10A 10A-1 10A-1 10A-3 (skim) 10A-3 (skim) 10A-4 10A-4.
Atomic Absorption Spectroscopy (AAS)
Atomic Mass Spectrometry
Mass Spectrometry.
Molecular Mass Spectrometry
LC-MS Lecture 7.
Introduction to the Varian ICP-MS. What is a mass spectrometer? The Inductively Coupled Plasma Mass Spectrometer (ICP-MS) is a fast, precise and extremely.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Mass Spectrometer Mass spectrometere is a very powerful method to analyse the structure of organic compounds.
Agilent 7500 ICP-MS Date: 28JUL2005.
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
Secondary ion mass spectrometry (SIMS)
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Mass Spectroscopy 1 Mass Spectroscopy (Mass Spec) Applying Atomic Structure Knowledge to Chemical Analysis.
Adv. Inst. Techs.  flame emission (eg flame photometer) known as low temperature emission ( K) ◦ first form of spectroscopy ◦ used in commercial.
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
ATOMIC SPECTROMETRY 1. Flames 2. Electrothermal Atomizers 3. Plasmas.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
Plasma A Plasma consists of a collection of free-moving electrons and ions and is very hot. Energy must be continually applied to sustain the plasma.
Chem. 133 – 4/12 Lecture. Announcements I Strike – No Strike now planned Exam 2: – Average was 77 (range 61 to 93) Last HW Set (Set 3 – see handout) Lab.
Chemistry 4631 Instrumental Analysis Lecture 18 Chem 4631.
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
THE MASS SPECTROMETER WHAT IS A MASS SPECTROMETER
CHEM133 Mass Spectrometry: Lecture 1
Components of Mass Spectrometer
Analytical Chemistry II ChEm 321
Flame Emission Spectrometry
Atomic structure L.O. 1. To be able to recall definitions of relative atomic, isotopic and molecular mass. 2. To learn about the key principles of mass.
Chem. 133 – 4/13 Lecture.
Introduction to the Varian ICP-MS
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Instrumental Chemistry
Instrumental Chemistry
Mass Spectroscopy (MS) Applications as Residual Gas Analyzer (RGA)
Пламена Спектроскопија
Residual Gas Analyzer (RGA)
Atomic absorption spectroscopy
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
M.Prasad Naidu MSc Medical Biochemistry, Ph.D,.
Inductively Coupled Plasma
Mass spectrometry (MS) is an analytical technique that can be used to determine the mass, elemental composition or chemical structure of molecules. Mass.
Suppose we make a new compound containing of C,H, and N
Presentation transcript:

1 In-house Training on ICP-MS

ICP-MS??? Inductively Coupled Plasma Mass Spectrometry or ICP-MS is an analytical technique used for elemental determinations. An ICP-MS combines a high-temperature ICP (Inductively Coupled Plasma) source with a mass spectrometer. The ICP source converts the atoms of the elements in the sample to ions. These ions are then separated and detected by the mass spectrometer.

Atomic Spectroscopy Techniques Three techniques share the same basic components Atomic Absorption (Flame and Furnace) ICP-AES ICP-MS All three are used for the analysis of metals

Comparison of Techniques ICP-MSICP-AESGFAASFAAS Detection LimitsExcellentGoodExcellentGood ProductivityExcellent LowGood Precision1-3%0.3 – 2 %1 – 5 %0.1 – 1 % Chemical Interferences ModerateFewMany IonizationMinimal Some Mass EffectsHigh on low mass None Dissolved solids0.1 – 0.4 %2 – 25 %Up to 20 %0.5 – 3 % # Elements Sample UsageLowMediumVery LowHigh Isotope AnalysisYesNo Method DevelopmentSkill required Easy Running CostsHigh MediumLow Capital CostsVery highHighMediumLow

ICP-MS Components Sample Introduction Plasma Generation Interface Ion Optics Mass Analyzer Vacuum System

Sample Introduction Delivers finely divided sample (usually aerosol) to plasma Plasma Source  Ion Source  Ar plasma  K Interface Allows transfer of atmospheric pressure ion source to high-vacuum mass analyser

Ion Optics Focuses ion beam and helps eliminate neutral species and photons Mass Analyzer Separates and measures individual ions by mass Vacuum System  Provides low pressure environment for mass spectrometer to operate effectively (no collisional losses)  Enables transition from plasma to high-vacuum via interface region

The Detector Converts ions into electrical pulses Magnitude of the electrical pulse is proportional to the number of ions in sample

Sample nebulized in spraychamber Argon transports sample and sustains plasma RF generator supplies energy to induction coil Sample atomized and ionized in the plasma Ions are transmitted through the interface, most of the gas removed Quadrupole filters the ions by mass Detector counts the ions Steps Involved in ICP-MS

How is a Plasma formed?

Sample Introduction System Low uptake concentric nebulizer standard External spraychamber  Double pass glass spray chamber  Room temperature to -15º C  Moves with torch Three channel peristaltic pump  Computer controlled  Smart Rinse enabled for optimized rinseout

The Plasma A plasma is a cloud of ionized gas Plasma temperature K Most elements >90% ionized Singly charged positive ions predominate Small molecular and doubly charged ion population Complete elemental analysis in a single determination

ICP-MS Torch

Process to form Plasma A flow of argon gas is passed between outer and middle tube of torch RF power is applied to load coil producing intense electromagnetic field A high-voltage spark produces free electrons Free electrons are accelerated by electric field Accelerated free electrons produce high energy collision and ionization of Argon gas Self-sustaining plasma is formed at open end of quartz torch

Processes in the Plasma Recombination ← Ionisation ← Atomisation ← Vaporisation Oxides ← Ions ← Atoms ← Gas ← Solid ← Liquid Sample aerosol M(H 2 0) + X- MXn MX M+ MO+

ICP: Why are there four gas flows? – Auxiliary Flow holds plasma away from torch/injector tube prevents torch melting – Plasma Flow forms the plasma – Nebulizer Flow punches cooler channel through centre of plasma carries sample – Sheath Gas (some ICPMS instruments) Allows control of the velocity of the center channel independent of the sample delivery rate

Interface: Ion Sampling TURBO- MOLECULAR PUMP VACUUM PUMP SAMPLER CONE SKIMMER CONE PLASMA ZONE OF SILENCE INTERFACE ~5 Torr ATMOSPHERE 760 Torr ROTARY ION OPTICS ~1x10 -4 Torr

19 ICP-MS Cones Sample Ions from the Plasma Sampler Cone Plasma encounters this cone first Skimmer Cone Located behind the sampler cone

The Mass Spectrometer Responsible for the high sensitivity of ICPMS instruments. Separates ionized species on the basis of their mass to charge ratio. Requires high vacuum (~ Torr) to operate Resolution must allow detection of low concentration elements in presence of adjacent high concentration elements. Scanning speed must be fast enough to cope with transient signals from various sample introduction systems Must accept a wide distribution of ion energies

Mass Spectrometer: Common Mass Analyzers Quadrupole Ion Trap Time of Flight Double-Focusing Magnetic Sector

Mass Spectrometer: Quadrupole Mass Analyser Schematic Only one mass has a stable trajectory

Vacuum System: Turbomolecular Pumps

Rotary Pumps

Element Name Element Symbol ArsenicAsLithiumLi BariumBaManganeseMn BerylliumBeMercuryHg BismuthBiNickelNi CadmiumCdRubidiumRb CesiumCsSeleniumSe ChromiumCrSilverAg CobaltCoStrontiumSr CopperCuThalliumTl GalliumGaUraniumU IndiumInVanadiumV LeadPbZincZn Elements analysed by ICP-MS in ARD

Analysis of Samples by ICP-MS Follow BCSIR SOP – 22 Prepare tuning solution Prepare standard solution of metals of different concentrations Always use de-ionized water having a resistivity of 17.5–18.5 MΩ/cm Use suprapure ICP-MS grade acids

Seven Elements of Quality Control during sample analysis by ICP-MS Certification of operator competence Calibration Analysis of externally supplied standards Analysis of blanks Analysis of duplicates Recovery of known additions Control charts

The End