A Study on Leakage and Energy Resolution

Slides:



Advertisements
Similar presentations
Beam-plug and shielding studies related to HCAL and M2 Robert Paluch, Burkhard Schmidt November 25,
Advertisements

US CMS H1/H2 Issues1 H C A L Dan is interested in the calibration of the HCAL for jets. He defines “R” as the measured energy of a pion, probably in ADC.
Electromagnetic shower in the AHCAL selection criteria data / MonteCarlo comparison of: handling linearity shower shapes CALICE collaboration meeting may.
1 AHCAL answers IDAG Erika Garutti On behalf of AHCAL analysis team.
INTRODUCTION TO e/ ɣ IN ATLAS In order to acquire the full physics potential of the LHC, the ATLAS electromagnetic calorimeter must be able to identify.
Interactions of hadrons in the SiW ECAL (CAN-025) Philippe Doublet - LAL Roman Pöschl, François Richard - LAL CALICE Meeting at Casablanca, September 22nd.
1 Study of the Tail Catcher Muon Tracker (TCMT) Scintillator Strips and Leakage with Simulated Coil Rick Salcido Northern Illinois University For CALICE.
1 N. Davidson E/p single hadron energy scale check with minimum bias events Jet Note 8 Meeting 15 th May 2007.
A preliminary analysis of the CALICE test beam data Dhiman Chakraborty, NIU for the CALICE Collaboration LCWS07, Hamburg, Germany May 29 - June 3, 2007.
1 Calice Analysis Meeting 13/02/07David Ward Just a collection of thoughts to guide us in planning electron analysis In order to end up with a coherent.
1/9/2003 UTA-GEM Simulation Report Venkatesh Kaushik 1 Simulation Study of Digital Hadron Calorimeter Using GEM Venkatesh Kaushik* University of Texas.
Track Extrapolation/Shower Reconstruction in a Digital HCAL – ANL Approach Steve Magill ANL 1 st step - Track extrapolation thru Cal – substitute for Cal.
Michele Faucci Giannelli TILC09, Tsukuba, 18 April 2009 SiW Electromagnetic Calorimeter Testbeam results.
LCG Meeting, May 14th 2003 V. Daniel Elvira1 G4 (OSCAR_1_4_0) Validation of CMS HCal V. Daniel Elvira Fermilab.
Interactions of pions in the Si-W ECAL prototype Towards a paper Naomi van der Kolk.
Energy Flow Technique and *where I am Lily Have been looking at the technique developed by Mark Hodgkinson, Rob Duxfield of Sheffield. Here is a summary.
Optimizing DHCAL single particle energy resolution Lei Xia Argonne National Laboratory 1 LCWS 2013, Tokyo, Japan November , 2013.
Irakli Chakaberia Final Examination April 28, 2014.
Optimizing DHCAL single particle energy resolution Lei Xia 1 CALICE Meeting LAPP, Annecy, France September 9 – 11, 2013.
The CALICE Si-W ECAL - physics prototype 2012/Apr/25 Tamaki Yoshioka (Kyushu University) Roman Poschl (LAL Orsay)
DHCAL - Resolution (S)DHCAL Meeting January 15, 2014 Lyon, France Burak Bilki, José Repond and Lei Xia Argonne National Laboratory.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
Event Reconstruction in SiD02 with a Dual Readout Calorimeter Detector Geometry EM Calibration Cerenkov/Scintillator Correction Jet Reconstruction Performance.
1 Calice UK Meeting 27/03/07David Ward Plans; timescales for having analysis results for LCWS Status of current MC/data reconstruction Reconstruction status;
CALICE Digital Hadron Calorimeter: Calibration and Response to Pions and Positrons International Workshop on Future Linear Colliders LCWS 2013 November.
January 21, 2007Suvadeep Bose / IndiaCMS - Santiniketan 1 Response of CMS Hadron Calorimeter to Electron Beams Suvadeep Bose EHEP, TIFR, Mumbai Outline:
7 May 2009Paul Dauncey1 Tracker alignment issues Paul Dauncey.
Results from particle beam tests of the ATLAS liquid argon endcap calorimeters Beam test setup Signal reconstruction Response to electrons  Electromagnetic.
Interactions of hadrons in the SiW ECAL Towards paper Naomi van der Kolk.
1ECFA/Vienna 16/11/05D.R. Ward David Ward Compare these test beam data with Geant4 and Geant3 Monte Carlos. CALICE has tested an (incomplete) prototype.
13 July 2005 ACFA8 Gamma Finding procedure for Realistic PFA T.Fujikawa(Tohoku Univ.), M-C. Chang(Tohoku Univ.), K.Fujii(KEK), A.Miyamoto(KEK), S.Yamashita(ICEPP),
Min-DHCAL: Measurements with Pions Benjamin Freund and José Repond Argonne National Laboratory CALICE Collaboration Meeting Max-Planck-Institute, Munich.
Custom mechanical sensor support (left and below) allows up to six sensors to be stacked at precise positions relative to each other in beam The e+e- international.
ScECAL Beam FNAL Short summary & Introduction to analysis S. Uozumi Nov ScECAL meeting.
1 1 - To test the performance 2 - To optimise the detector 3 – To use the relevant variable Software and jet energy measurement On the importance to understand.
Longitudinal shower profile - CERN electron runs Valeria Bartsch University College London.
Calice Meeting Argonne Muon identification with the hadron calorimeter Nicola D’Ascenzo.
AHCAL analyses overview List of ongoing analyses targeted to the upcoming publications Erika Garutti.
Interactions of hadrons in the SiW ECAL (CAN-025) Philippe Doublet - LAL Roman Pöschl, François Richard - LAL SiW ECAL Meeting at LLR, February 8th 2011.
DREAM Coll. Meeting, Rome 2009F. Bedeschi, INFN-Pisa Template Analysis of DRS Data  Motivations  Preliminary results F. Bedeschi, R. Carosi, M. Incagli,
Régis Lefèvre (LPC Clermont-Ferrand - France)ATLAS Physics Workshop - Lund - September 2001 In situ jet energy calibration General considerations The different.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
09/06/06Predrag Krstonosic - CALOR061 Particle flow performance and detector optimization.
Energy Reconstruction in the CALICE Fe-AHCal in Analog and Digital Mode Fe-AHCal testbeam CERN 2007 Coralie Neubüser CALICE Collaboration meeting Argonne,
Interactions of pions in the Si-W ECAL prototype Towards a paper Naomi van der Kolk.
W Prototype Simulations Linear Collider Physics & Detector Meeting December 15, 2009 Christian Grefe CERN, Bonn University.
K. Holubyev HEP2007, Manchester, UK, July 2007 CP asymmetries at D0 Kostyantyn Holubyev (Lancaster University) representing D0 collaboration HEP2007,
DESY BT analysis - updates - S. Uozumi Dec-12 th 2011 ScECAL meeting.
ECAL Interaction layer PFA Template Track/CalCluster Association Track extrapolation Mip finding Shower interaction point Shower cluster pointing Shower.
HCAL Leakage Studies CLIC Physics & Detector Meeting 10. November 2008 Christian Grefe CERN.
Michele Faucci Giannelli
or getting rid of the give-away particles in a test-beam environment
on behalf of ATLAS LAr Endcap Group
Predrag Krstonosic - ILC Valencia
CALICE scintillator HCAL
Interactions of hadrons in the Si-W ECAL
Calice Collaboration Meeting Sep. 2009
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Introduction The aim of this talk is to try to get a feeling on the expected degradation of performance of a calibration once we move from MonteCarlo.
ScECAL+AHCAL+TCMT Combined Beam FNAL
Scintillator HCAL: LOI issues
Plans for checking hadronic energy
Rick Salcido Northern Illinois University For CALICE Collaboration
Reports for highly granular hadron calorimeter using software compensation techniques Bing Liu SJTU February 25, 2019.
Michele Faucci Giannelli
Status of CEPC HCAL Optimization Study in Simulation LIU Bing On behalf the CEPC Calorimeter working group.
Steve Magill Steve Kuhlmann ANL/SLAC Motivation
LC Calorimeter Testbeam Requirements
Rick Salcido Northern Illinois University For CALICE Collaboration
Presentation transcript:

A Study on Leakage and Energy Resolution Ivan Marchesini , CALICE Collaboration Meeting, 2010-09-22

Outlook Introduction. Pion event selection. Variables sensitive to the leakage: Shower Start; End-Fraction. A correction to the leakage. Comments and next steps.

Introduction

Cern 2007 Prototype This study uses pion data collected in 2007 at CERN by the CALICE prototype. ECAL HCAL TCMT 1λ 4.5λ 10 λ ECAL+HCAL+TMCT: leakage from the complete set-up very small, in the energy region of interest of ILD.

Tasks of the Study - 1 1) Study a correction to the leakage from the HCAL, using the HCAL alone, without TCMT information. ECAL HCAL TCMT This talk In an ILD/Particle Flow perspective a correction to the leakage essentially matters for the neutrals (study on the pions easily transferable).

Tasks of the Study – 1 This part of the study does not consider the punchthrough pions, that start showering in the TCMT (~1%). Studies of corrections to the leakage, so far: developed in an idealistic case: using the a-priori knowledge of the beam energy. power: 14% sigma/mean relative improvement at 80 GeV (B.Lutz PhD Thesis). Main task of the study is to develop a realistic correction: no a-priori knowledge of the beam energy.

Tasks of the Study - 2 2) In ILD non-instrumented coil between HCAL and TMCT. Can be simulated removing information from the first TCMT layers. See the benefit of having additionally a TCMT in such an ILD-like configuration: ECAL HCAL TCMT Not in this talk

Single Pion Event Selection

Event Selection CERN 2007 pion- runs. Examples for 80 GeV run 330962. Cuts: 0.5 MIP threshold. TRIGGER: BeamBit==1; b100x100Bit==0 no muons. CherenkowBit==0 no electrons. Shower start in the HCAL: Marina processor: shower start after HCAL layer 2. Currently excluding also layers 37, 38, since the processor puts the punchthrough at the end of the HCAL. Triangle cut included: E TCMT vs E HCAL+ECAL for muon rejection. Further muon rejection. Frac-10 cut: E hits > 10 MIPs / total E > 0.01 (for ECAL + HCAL + TCMT).

Note Selecting a subsample of the full sample, with more leakage from the HCAL in average, than the full-sample: Using the ECAL only as a tracker reduces systematics and simplifies selection and analysis. Negligible amount of events with leakage excluded. Study is not biased, but one needs to remember that the effect of the leakage from the HCAL, on the energy resolution, is amplified, when comparing with the full sample.

Total Energy ECAL+HCAL+COIL+TCMT = ILD All ECAL+HCAL

Variables Sensitive to Leakage

End-fraction & Shower Start End-fraction: fraction of measured energy from the shower start deposited in the end (last 4 layers) of the HCAL: High End-fraction -> shower not concluded -> high leakage; Low End-fraction -> shower almost concluded -> low leakage.

Correction (Idealistic Case) Correction can be obtained, strongly energy dependent. Here applied in the idealist case (correction chosen depending on beam energy information).

Result Mean value recovered and RMS reduced. Power of the two corrections comparable: RMS/Mean relative improvement ~ 20%. Uncorrected Shower Start Corr End-Fraction Corr

Correction to the Leakage

Content Shower start and End-fraction: sensitive to the leakage but corrections are energy dependent. Idea: add measured energy observable to obtain an energy independent correction. I present here a Monte Carlo study. Monte Carlo files: physics list: FTFP_BERT; detector model: TBCern0707_p0709. Correction studied over the full energy range [2.5, 100] GeV.

3D Distribution X: shower start layer; Y: End-fraction; Z: measured energy (Ecal+Hcal). 80 GeV 70 GeV 60 GeV 50 GeV 40 GeV

2D Projections 80 GeV 70 GeV 60 GeV 50 GeV 40 GeV

Correction Structure Different energies cover different regions of the 3D space, though with overlaps. Idea: use the position in the 3D space to replace the beam energy information use. Note: shower start finder uses the beam energy information, but a new version which uses the measured energy already implemented (Alex and Marina) and included in the new software release of last week. Build a template using energies from [2.5,100] GeV. Apply the correction to energies not used to build the template, to assure statistical independence.

Fit: Step 1 Shower start/ End-fraction 2D distributions.

Fit: Step 2 For each bin Shower start/ End-fraction 2D distributions correction based on the plot: average measured energy vs true beam energy. True ene (GeV) True ene (GeV) Bin : early start/low End-fraction => no leakage Bin : advanced start/higher End-fraction => leakage for high energies Measured ene (GeV) Measured ene (GeV)

Application: 87.5 GeV Correction is able to identify proper energy. RMS90/Mean % improvement 27%: effect comparable to the individual energy-tuned corrections. Mean 74.1 RMS 17.2 RMS90 10.4 Mean 87.2 RMS 15.7 RMS90 8.9 Uncorrected Corrected

Application: 3.75 GeV Ideal correction should leave untouched the low energies. Correction does not spoil significantly the low energies. Mean 3.63 RMS 0.63 RMS90 0.52 Mean 3.80 RMS 0.70 RMS90 0.56 Uncorrected Corrected

Correction Response (Partial) Good recovery of the leakage. Mean recovery better than 1% over the full range from 10 GeV. Under control even at very low energies < 10 GeV (2.5%). RMS90 % improvement 15% at high energies.

Fit: Step 3 Possible to further improve the fit response, adding on top a correction to the events depending on the measured energy corrected, using the average deviation of the fit response as a function of the measured energy.

Final Correction Response Mean improvement further improved, without spoiling the RMS improvement. Fit response better than ~0.5% over the full range, including low energies.

About Energy Distributions This fit structure not influenced by the chosen energy distribution. Ex: flat vs exponential peaking at low energies (exp(-0.05*Energy)). Results are compatible. On the other side. The correction is event-wise, therefore assumptions on the energy distribution of the sample to be corrected is not relevant.

Importance of the Calorimeter Depth MC fit works perfectly but does not replace a deeper calorimeter. Using the TCMT information still gives a better resolution with respect to the HCAL only + correction response.

Next Steps & Conclusions

Next Steps & Conclusions The high granular calorimeter promising for a correction to the leakage. Correction powerful in restoring the mean of the total energy, and reduces the RMS, but does not replace the calorimeter depth. Application to data is being finalized. Possible improvement: apply the correction on top the energy density re-weighting. The re-weighting should increase the correlation between the leakage and the observables used for the correction.

End

Additional Slides

Resolution Compare resolution for the full-sample and pion showers after the 2nd HCAL layer: weights optimized for individual energies with Ebeam constraint. Selection of showers starting in the ECAL not optimized (purpose is only this plot). Leakage effect is more evident for the second subsample. Showers from ECAL Showers from 3rd layer HCAL

Note: Monte Carlo Linearity Relevant for the study to check the proper response of the correction to different energies. Important to start with a good Monte Carlo linearity in terms of energy. Linearity depends on a proper choice of: Sampling weights, which express the fraction of visible energy and are energy-dependent. Mip to GeV conversion. For the purpose of the study Monte Carlo produced without noise and without zero-suppression: at low energies noise creates relevant deviation from linearity. Difficult to disentangle from correction effects.

Sampling Weights Optimization ECAL HCAL TCMT 1 2 3 4 5 6 6 weights for different sections. SW by a c2 minimization on the total energy: We use pions starting in the HCAL, no sensitivity ECAL weights: ratios between w1, w2, w3 fixed to those given by the literature.

Monte Carlo Linearity Still deviation, due to some uncertainty in the sampling weights optimization, but not big.

Fit: Details - 1 Fit a pol2 to the distribution. In case the curvature of the pol2 is too small (0.0001), fit a pol1. Inverse of the fitting function gives the correction to be applied to the measured energy.

Fit: Details - 2 In case for a certain event solution of the inverse pol2 fit should not exist, or correction for small energies should give a negative value, using the average correction for the measured energy in that bin (~1% of the events get this correction).