Stefano Bianco for the Frascati and Napoli groups June 29, 2012 In collaboration with Richard Fortin - PH-DT-DI CERN AIDA ENVIRONMENTAL SENSORS STATUS REPORT
March 16th, 2012AIDA S.Bianco Environmental sensors2 OBJECTIVE atmospheric (p), temperature (T), relative humidity (RH) monitoring of GIF++ experimental area possibly include experimental gases RH monitoring o(10) sampling points total, in irradiated and non-irradiated areas Precision o C T +-2% RH Simple, cost- and labour- effective technique Complying to CERN monitoring standards PVSS/DCS Reusing existing material if possible
March 16th, 2012AIDA S.Bianco Environmental sensors3 GIF (R.Fortin PH-DT-DI) The existing GIF sensors are ~15 years old and addressed via Profibus. Three weather stations in separate sampling locations: Control Room (T, RH, p) - Irradiation Room (T,RH) - Gas Area (T,RH,p) Each location uses a Wago module to provide the interface support. At the time of X5 beam the Profibus was made available to all GIF users, but today only the weather stations are connected. tcp/ip over the CERN network seems "lighter" to install if we start from scratch. The existing GIF system is not directly compatible with PVSS/DCS
March 16th, 2012AIDA S.Bianco Environmental sensors4 Conceptual layout n.4 gas sampling points INFLOW, OUTFLOW each with 2 sampling points p, T, RH measurements n.1 environment sampling point p, T, RH measurement n.5 environment sampling points T, RH measurement Pb shielding in radiation area BASELINE READOUT PICO ADC Software: Labview + PVSS + DCS OPTION READOUT CAEN System SY5527+ A1676A board+EZcrate3000+ A3801A ADC Software: DCS
March 16th, 2012AIDA S.Bianco Environmental sensors5 EXAMPLE OF BASELINE DESIGN IN SGX5: SENSORS BOX OF CMS RPC GAS GAIN MONITORING SYSTEM n.2 PICO ADC + Gefran sensors + Mitchell sensors 10 sampling points Stainless steel gas receptacles (3 gas lines) and environmental sensors LabView + PVSS + DCS
March 16th, 2012AIDA S.Bianco Environmental sensors6 EXAMPLE OF BASELINE DESIGN IN SGX5: SENSORS BOX OF CMS RPC GAS GAIN MONITORING SYSTEM n.2 PICO ADC + Gefran p sensors + Mitchell T,RH sensors 10 sampling points Stainless steel gas receptacles (3 gas lines) and environmental sensors LabView + PVSS + DCS
PLAN Estimate of costs/labour for baseline and option (see A.Polini’s DCS presentation)