[1] Ophir, Jonathan, et al. "Elastography: a quantitative method for imaging the elasticity of biological tissues." Ultrasonic imaging (1991) [2] Muthupillai,

Slides:



Advertisements
Similar presentations
Wave propagation via laser ultrasound IR laser focused on 19 mm line Laser line source.
Advertisements

Foundations of Medical Ultrasonic Imaging
Chen Wu 1, Zhaolong Han 1, Shang Wang 1,5, Jiasong Li 1, Manmohan Singh 1, Chih-hao Liu 1, Salavat Aglyamov 2, Stanislav Emelianov 2, Fabrice Manns 3,4,
PHOTOACOUSTIC PROBE FOR TUMOR DETECTION
Two dimensional elasticity mapping of partially cross-linked rabbit corneas using optical coherence elastography Jiasong Li 1, Manmohan Singh 1, Srilatha.
Frequency Domain Optical Coherence Tomography (FDOCT) Joon S Kim IMSURE Summer Research Fellow At Beckman Laser Institute University of California at Irvine.
ECE 501 Introduction to BME
Ultrasonic Nonlinear Imaging- Tissue Harmonic Imaging.
Optical Coherence Tomography Zhongping Chen, Ph.D. Optical imaging in turbid media Coherence and interferometry Optical coherence.
Introduction Theory Methods Experiments Results Application Summary Dr. Heiko Maaß Institut für Angewandte Informatik Noninvasive Measurement of Elastic.
Ultrasound Medical Imaging Imaging Science Fundamentals.
In Vivo Evaluation of a Mechanically-Oscillating Dual- Mode Applicator for Ultrasound Imaging and Thermal Ablation Neil Owen et al. IEEE Transactions on.
1 Swept Source Frequency Domain Optical Coherence Tomography Swept Source Frequency Domain Optical Coherence Tomography Anurag Gupta University of Rochester,
Non Destructive Testing: Finding Defects in Metal Objects
2-DIMENSIONAL KASAI VELOCITY ESTIMATION FOR DOPPLER OPTICAL COHERENCE TOMOGRAPHY Darren Morofke a,b,c, Michael C. Kolios a,b, Victor X.D. Yang b,d a Dept.
Ultrasound Imaging Atam Dhawan.
Introduction Theory Methods Experiments Results Application Summary Dr. Heiko Maaß Institut für Angewandte Informatik Noninvasive Measurement of Elastic.
What is OCT? Ultrahigh resolution optical coherence tomography (UHR OCT) is an upcoming new technology that allows non-invasive, optical medical diagnostic.
Concept Generation Mechanical Actuator for Magnetic Resonance Elastography of the Lumbar Spine Overview Background Information Project Scope Metrics Design.
1 Opto-Acoustic Imaging 台大電機系李百祺. 2 Conventional Ultrasonic Imaging Spatial resolution is mainly determined by frequency. Fabrication of high frequency.
Introduction to the Physics of Ultrasound
Ultrasound measurements on tissue Penny Probert Smith Institute of Biomedical Engineering Department of Engineering Science University of Oxford (also.
Principles of Medical Ultrasound
Doppler echocardiography & Magnetic Resonance Imaging.
1 RADIATION FORCE, SHEAR WAVES, AND MEDICAL ULTRASOUND L. A. Ostrovsky Zel Technologies, Boulder, Colorado, USA, and Institute of Applied Physics, Nizhny.
Photo-induced Multi-Mode Coherent Acoustic Phonons in the Metallic Nanoprisms Po-Tse Tai 1, Pyng Yu 2, Yong-Gang Wang 2 and Jau Tang* 2, 3 1 Chung-Shan.
1 Ultrasonic Elasticity Imaging. 2 Elasticity Imaging Image contrast is based on tissue elasticity (typically Young’s modulus or shear modulus).
Ultrasonic imaging parameters ~Attenuation coefficient Advisor: Pai-Chi Li Student: Mei-Ru Yang Wei-Ning Lee.
WHY ???? Ultrashort laser pulses. (Very) High field physics Highest peak power, requires highest concentration of energy E L I Create … shorter pulses.
Building Three-Dimensional Images Using a Time-Reversal Chaotic Cavity
Abstract: A laser based ultrasonic technique for the inspection of thin plates and membranes is presented, in which Lamb waves are excited using a pulsed.
Quantitative assessment of the biomechanical properties of tissue-mimicking phantoms by optical coherence elastography via numerical models Zhaolong Han,
Assessment of wave propagation in mice cornea and lens using phase stabilized swept source optical coherence tomography Ravi K. Manapuram, Floredes M.
WAVES Wave - a periodic disturbance that propagates energy through a medium or space, without a corresponding transfer of matter. e.g.1 sound wave (regular.
Tissue classification of nephritic kidney using optical coherence elastography (OCE) Chih-Hao Liu1, Manmohan Singh1, Jiasong Li1, Chen Wu1, Raksha1, Rita.
4-Jun-161 ULTRASOUND IMAGING Lec 1: Introduction Ultrasonic Field Wave fundamentals. Intensity, power and radiation pressure.
Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.
1/20 Joyce McLaughlin Rensselaer Polytechnic Institute Interior Elastodynamics Inverse Problems I: Basic Properties IPAM – September 9, 2003.
3. Optical Coherence Tomography (OCT)
Harmonic Deconvolution in Ultrasound Vibro-Acoustic images Alexia Giannoula Communications group, Dept of Electrical & Computer Engineering, University.
Quantitative Assessment of Hyaline Cartilage Elasticity during Optical Clearing using Optical Coherence Elastography Chih-Hao Liu 1, Manmohan Singh 1,
The effects of curvature and thickness of cornea-based structures assessed by finite element modeling and optical coherence elastography Zhaolong Han,
Image Compression in Optical Coherence Tomography Biomedical Engineering, Tambov State Technical University, Russia K.E.S.Ghaleb, A.Yu.Potlov, S.N.Abdulkareem,
1 Resolution Enhancement Compression- Synthetic Aperture Focusing Techniques Student: Hans Bethe Advisor: Dr. Jose R. Sanchez Bradley University Department.
Tissue analysis of nephritic kidney using optical coherence elastography (OCE) Chih-Hao Liu1, Manmohan Singh1, Jiasong Li1, Chen Wu1, Raksha1, Rita Idugboe1,
Ultrasonic imaging parameters ~Attenuation coefficient Advisor: Pai-Chi Li Student: Mei-Ru Yang Wei-Ning Lee.
12-Jun-161 ULTRASOUND IMAGING Lec 1: Introduction Ultrasonic Field Wave fundamentals. Intensity, power and radiation pressure.
Date of download: 6/21/2016 Copyright © 2016 SPIE. All rights reserved. Scanning mechanisms for (a) conventional FD-OCT and (b) streak-mode FD-OCT. Figure.
Date of download: 6/22/2016 Copyright © 2016 SPIE. All rights reserved. Schematic of spectral-domain optical coherence tomography (SD-OCT) system and forward-facing.
1 Opto-Acoustic Imaging 台大電機系李百祺. 2 Conventional Ultrasonic Imaging Spatial resolution is mainly determined by frequency. Fabrication of high frequency.
Date of download: 7/8/2016 Copyright © ASME. All rights reserved. From: Measurement of the Dynamic Shear Modulus of Mouse Brain Tissue In Vivo by Magnetic.
Metallurgha.ir1. Lecture 5 Advanced Topics II Signal, Noise and Bandwidth. Fundamental Limitations of force measurement metallurgha.ir2.
DVM Summary and Acoustic Microscopy Imaging of Cu Sample
Pressure Vessel Inspection Techniques
By ASST. Prof. DR. ASEEL BASIM
Ultrasound.
Single-element transducers properties
Ultrasound.
Non-Destructive testing of Weldments
Optical Coherence Tomography
Vassiliy Tsytsarev University of Maryland school of Medicine
Spatially Varying Frequency Compounding of Ultrasound Images
Photo acoustic tomography
Review of Ultrasonic Imaging
Doppler Effect (continued from Lecture 13 - slides 7-12) Ultrasound
ELASTOGRAPHY - DR SHEFALI MESHRAM.
Electroencephalogram (EEG)
Magnetic resonance elastography can be used to image transplant kidney stiffness. Magnetic resonance elastography can be used to image transplant kidney.
Fig. 1 Experimental schematic and setup.
Presentation transcript:

[1] Ophir, Jonathan, et al. "Elastography: a quantitative method for imaging the elasticity of biological tissues." Ultrasonic imaging (1991) [2] Muthupillai, R., et al. "Magnetic resonance elastography by direct visualization of propagating acoustic strain waves." Science (1995)

Air-pulse OCE ( cornea ) [3] mm-OCE (Rat liver and chicken muscle) [6] Mechanical actuator for tissue phantom [4] [3] Wang, Shang, and Kirill V. Larin. "Shear wave imaging optical coherence tomography (SWI-OCT) for ocular tissue biomechanics." Optics letters (2014) [4] Nguyen, Thu-Mai, et al. "Shear wave pulse compression for dynamic elastogrcoherence tomography." Journal of biomedical optics (2014) [5] Song, Shaozhen, et al. "Quantitative shear-wave optical coherence elastography with a programmable phased array ultrasound as the wave source." Optics letters (2015) [6] Ahmad, Adeel, et al. "Magnetomotive optical coherence elastography using magnetic particles to induce mechanical waphy using phase-sensitive optical aves." Biomedical optics express (2014) Ultrasound as wave source (porcine retina) [5]

Megahertz Optical Coherence Elastography  ~1.5 MHz A-scan rate  New scanning mechanism compared to conventional OCE

Sample Air-pulse Excitation OCT Scan Path [3] Wang, Shang, and Kirill V. Larin. "Shear wave imaging optical coherence tomography (SWI-OCT) for ocular tissue biomechanics." Optics letters (2014)

Sample Air-pulse Excitation OCT Scan Path

 Megahertz OCE system ~1.5 MHz A-scan rate 4X Buffered FDML OptoRes Gmbh 1316 nm central wavelength 100 nm bandwidth 16 µm axial resolution Up to 160 mW of power 7.3 kHz resonant scanner  Lorentz force excitation system Waveform generator Power amplifier Two magnets Probe

Future work  Improve the SNR of displacement signal; Electrical current Magnetic field Tissue conductivity  Analyze tissue viscoelasticity by elastic wave dispersion  Frequency analysis