Water Cooled Screw Chillers And Water/Water Heat Pumps.

Slides:



Advertisements
Similar presentations
Welcome Bienvenue Willkommen Bienvenido Добро пожаловать ようこそ 歡迎.
Advertisements

Operated by the Southeastern Universities Research Association for the U.S. Department of Energy Thomas Jefferson National Accelerator Facility Page 1.
Johnson Controls1 YORK Model YVAA Air-Cooled Chillers Variable Speed Screw, tons.
CNG Refuelling station. A company located in Cherasco (Italy), is among the world leaders in the field of designing and manufacturing of components and.
Engineer Presentation
C oncerns Ltd ool Energy Efficient Refrigeration Jane Gartshore, Cool Concerns Ltd.
Thermosyphon - Free Cooling
Product Introduction.
44 th Annual Conference & Technical Exhibition By Thomas Hartman, P.E. The Hartman Company Georgetown, Texas Sustainable Chilled Water.
Jim Chmielewski – HVAC Sales Manager Emerson Control Techniques
UTSW Thermal Energy Plants, Power Generation and Electrical System What do we do to meet the Emission Reduction, Energy usage Reduction and Electrical.
RLC-CMS002-E4© American Standard Companies, inc All Rights Reserved Concentration of intelligence, High reliability. Series R TM.
ENGINEERING YOUR SUCCESS. PDF Market and Sales Meeting Refrigerated Dryers.
REFRIGERATION, COMPRESSED AIR SYSTEMS & EFFICIENT USE OF ENERGY
Chilled Water Systems Total Cost of Ownership
Refrigeration Terms Cooling Load, Cooling Capacity – Q in Compressor Load – W in Condenser Load – Q out Tons of Refrigeration – Rate of Heat Input Refrigerant.
CHAPTER 4 CPB 20004: Plant Utility n Maintenance
Grundfos FLOW THINKING Air conditioning the Grundfos Way.
Perfect solution for large building
Hawke’s Bay Refrigeration
Chilled water Meyrin consolidation Study 1 st Part Many thanks for their contribution to: Pasquale Alemanno, Fortunato Candito, Alexander Putzu.
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
© 2008 Data Power Services, LLC By: Tom Taranto 2010 Energy Expo Hosted by National Grid NYSERDA Reducing Compressed Air Energy Cost Using a Systems Approach.
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
Heat Transfer Equations For “thin walled” tubes, A i = A o.
NOVO ETS IMPROVING YOUR ORGANIZATIONS’ ENVIRONMENTAL, HEALTH AND SAFETY PERFORMANCE ENERGY MANAGEMENT IN THE CONTEXT OF GREEN PRODUCTIVITY.
Smartcool Systems Inc. Providing effective and reliable energy efficiency solutions for HVAC-R customers around the globe.
Flooded Screw Chiller FWSF Electronic Expansion Valve Condenser Evaporator Control box compressor Flooded Screw Chiller - FWSF.
November 2004 Low Hanging Fruit Low Cost Energy Efficiency Opportunities in Cleanrooms.
/ 1 ERA A chiller to suit everyone. Air cooled water chillers Free-cooling chillers Air/water heat pumps.
BCWC Water-cooled water chillers with centrifugal compressor/s
Pressure-Enthalpy and the Variable Refrigerant Cycle
We can…. 2 GLOBAL REFERENCES Rev: 00 References :
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Water is the Natural Choice Hydronic Comfort Systems Increase and Maintain Building Efficiency For the Life of Your Building
Water is the Natural Choice Water: The Natural Choice For Efficiency – Building System efficiency not just a unit rating – Equipment Ratings EER and COP.
Air Cooled Chillers with High Speed Centrifugal Compressors.
GeoExchange / Thermal Energy Storage Systems Reduce Overall Energy Use and Peak Demand.
I-RACH range I-RACH range I-RACH range I-RACH range High efficiency air/water heat pump with INVERTER scroll compressor Range Modularity Components Highlights.
James McIntyre VRF Training Manager V5 Key Components.
EMERGING TECHNOLOGIES AVAILABLE TO REDUCE COMPRESSED AIR DEMAND Double Acting Air Cylinder Double Acting Air Cylinder Air Operated Diaphragm Pumps Air.
Capacity Efficiency Versatility Reliability
Lecture Objectives: Learn about thermal storage systems
The New C55* CPVSd 10-20hp People. Passion. Performance.
Compact line ‘EW*D~J-’ water-cooled chiller range
CHIGO VRF System Commissioning.
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
HYDRONIC HVAC: The Most Comfortable and Efficient System
Chillers for Tomorrow… Today
Chiller Energy Audit Welcome remarks TBD..
WELCOME Indoor Chillers.
Thermal Energy Storage
2016, 9-11 & 13 May RTWF RTHF.
10TR Nominal Glycol Chiller
The advantages of going wireless
Emerson TX7 Series Thermostatic Expansion Valve.
New Air Cooled Scroll Chiller
Energy Efficiency in District Coiling System
August 23, 2000 R.N. Dubois Dow Chemical
Trane Care Energy RTHD Adaptive Frequency Drive retrofit.
SHANGHAI ROTORCOMP COMPRESSOR ONLY USE.
WELCOME Indoor Chillers.
Robicon Perfect Harmony.
Mathew C. Wright January 26, 2009
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Title RTWD Water-Cooled Chillers subtitle START
The smart choice for demanding motor switching
BSE Magnetic Levitation Oil Free Centrifugal Chiller Traditional Chiller.
Power monitoring software
Presentation transcript:

Water Cooled Screw Chillers And Water/Water Heat Pumps

YOUR EXPECTATIONS IN ONE PRODUCT Capacity Efficiency Versatility Reliability kW

RELIABILITYVERSATILITYEFFICIENCYCAPACITY HIGHEST CAPACITIES IN THE INDUSTRY 900 kW1100 kW1300 kW1500 kW1700 kW1900 kW2100 kW2300 kW RTHFRTWF RTWF SE RTWF HE RTWF HSE RTHF XE RTHF HSE Cooling capacities: 12/7°C Entering/Leaving evaporator - 30/35°C Entering/Leaving Condenser 2 circuits 3 or 4 compressors 2 circuits 2 compressors

RELIABILITYVERSATILITYEFFICIENCYCAPACITY ONE MODEL, FLEXIBLE DESIGN First Cost High Efficiency Best Value for Money Criteria HSE XE HE SE RTWF SE RTWF HE RTHF HSE RTHF XE RTWF HSE

RELIABILITYVERSATILITYEFFICIENCYCAPACITY UNIT DESIGN Compressor Direct drive, low Speed Load matching ₋ Min = 10% of load with Variable Speed ₋ Max = 15% of load with Fixed Speed Heat Exchangers Cross Flow Serial Heat Exchangers design Trane patented evaporator design New condenser design Designed to convert Trane compressor design into premium performance at all applications 3 Controls Fastest controls of the industry ₋ Safe VPF ₋ No nuisance trips (Adaptive controls) ₋ Temperature control within 0.3C 4 Adaptive Frequency ™ Drive Industry leading Seasonal Efficiency Eliminates inrush current

RELIABILITYVERSATILITYEFFICIENCYCAPACITY VARIABLE FLOW Pressure Drop Pump Power Flow Rate 100% 12.5% 100% 25% 50% Benefits Less pump power for more system efficiency  80% part load = 51% pump power  60% part load = 22% pump power  50% part load = 12.5% pump power Constant temperatures  Accurate stable controls Lower speed: Lower pump wear Less noise in piping and valves Full speed Reduced speed

RELIABILITYVERSATILITYEFFICIENCYCAPACITY Min. Flow 50% Max. Flow 150% Nom. Flow 100% VPF Area SmartFlow Control Algorithm designed to handle variations of 10% per minute Maintains water temperature within ± 0.3 o C Ability to deliver a signal to control variable speed pump %Flow variation Leaving Water temp o C ±0.3 o C Time (minutes) VARIABLE FLOW COMPATIBILITY Evaporator Designed to afford VPF

RELIABILITYVERSATILITYEFFICIENCYCAPACITY Series counterflow configuration Improves system efficiency Saves installation cost  Smaller diameter piping  Fewer pumps  Smaller pumps Great opportunity for Free Cooling on first Chiller (if appropriate) VPF operation further enhances system efficiency 1800 kW Traditional Parallel piped chillers configurationSeries Counterflow Configuration SERIES COUNTERFLOW CONFIGURATION Total pump power 134 kW Total pump power 100 kW

RELIABILITYVERSATILITYEFFICIENCYCAPACITY COMPRESSOR More than 28 years of experience Designed, built and tested according to the highest demanding and rugged standards Proven track record  More than compressors worldwide  Industry leading reliability: rate greater than 99.5% Fewer moving parts Direct drive low speed Suction gas cooled No oil pump needed Resistance to liquid slugging Field serviceable Wider operating map in the industry

RELIABILITYVERSATILITYEFFICIENCYCAPACITY CONTROLS Diagnostics Trane Adaptive Control TM Patented Industry leading algorithms Takes actions to prevent shutdown due to abnormal operating conditions: ₋ Flow failure ₋ Cooling tower or Dry cooler malfunction ₋ Extreme operating conditions Clear visibility of operation through graphics: ₋ Trend monitoring ₋ Performance follow-up ₋ Preventive maintenance anticipation More than 100 diagnostics made when a fault is detected Display indicates fault, time and date of diagnostic ₋ Quick localization of problem ₋ Faster action Allows problem fixing without shutting off ₋ Downtime minimized Trend Charts Intuitive Display in Local Language

RELIABILITYVERSATILITYEFFICIENCYCAPACITY TESTING Extended testing Operation in extreme operating conditions leading to World Class reliability ₋ Ambient Air: from -25 o C to 55 o C ₋ Leaving Water: from -12 o C to 65 o C Pressure vessels resistance Electro-Magnetic compatibility (CE compliance) Finite element analysis for structure and components design resistance and robustness Acoustics and vibrations testing

RELIABILITYVERSATILITYEFFICIENCYCAPACITY CE compliance Pressure Equipment Directive (PED) 97/23/CE Machinery Directive (MD) 2006/42/CE Low Voltage Directive (LV) 2006/95/CE Electromagnetic Compatibility Directive (EMC) 2004/108/CE Electrical Machinery Safety Standard EN Electromagnetic Emission and Immunity Standard EN category C3 Quality Insurance processes ISO9001 ISO rd Party certifications AHRI certification program (>700kW) Eurovent certification in 2016 Guaranteed performance of the investment QUALITY STANDARDS In 2016

RELIABILITYVERSATILITYEFFICIENCYCAPACITY DESIGNED FOR MULTIPLE APPLICATIONS Office buildingsHealthcareData CentersAutomotive Industry Pharmaceutical IndustryPlastic IndustryHospitality IndustryDistrict Cooling District Heating

RELIABILITYVERSATILITYEFFICIENCYCAPACITY OPERATING TEMPERATURE RANGE High condensing water Heating applications +65 o C Low condensing water +20 o C Comfort High Temp. Process +20 o C Low Brine Applications -12 o C 90% Elimination In 2 hours Instantaneaous Elimination 90% Elimination In 2 minutes Optimum temperatures for bacteria growth Bacteria alive But inactive Legionella Bacteria Development

RELIABILITYVERSATILITYEFFICIENCYCAPACITY HEAT PUMP OPERATION RTWF High leaving water temperature  Up to 65 o C High capacity water/water heat pump  Up to 2.0 MW at 40/45 o C*  Up to 1.9 MW at 47/55 o C* High COP**  Up to 4.55 at 40/45 o C*  Up to 3.55 at 47/55 o C* Dedicated and optimized compressor for heating applications * Entering/Leaving evaporator : 10/7 o C ** Net COP Calculated according to EN standard

RELIABILITYVERSATILITYEFFICIENCYCAPACITY BRINE PROCESS APPLICATIONS Compliant with Med Temp industrial process application minimum efficiency requirements (SEPR) ₋ European regulation (EU) 2015/1095 ₋ Entry into force on 2106, July 1 st Operation from 4 down to -12 o C leaving water temp Dedicated compressor for efficiency and reliability Operation with various brines: ₋ Ethylene Glycol ₋ Propylene Glycol ₋ Ethanol ₋ Value of standardized design, capable to meet special requirements

RELIABILITYVERSATILITYEFFICIENCYCAPACITY Ice usage Chiller usage Building Load Time of the day Typical ice storage application ICE STORAGE Energy storage application Chiller builds ice when utility rates are lower, or when heating requirement overtakes cooling requirement Chiller smartly balances the contribution of ice melting and chiller operation to meet the cooling load with the best system efficiency Controls takes charge of: ₋ controlling set points, ₋ actuating chiller and or ice pump and other accessories

RELIABILITYVERSATILITYEFFICIENCYCAPACITY Compatible with all Trane Building Management Systems and chiller plant controls Communication interfaces BACnet ™ IP BACnet ™ MSTP ModBus ™ RTU LonTalk ™ (LCI-C) COMMUNICATION

YOUR EXPECTATIONS IN ONE PRODUCT Capacity Efficiency Versatility Reliability kW

Copyright ©Ingersoll Rand, 2016, all rights reserved.