Anterior segment Scheimpflug imaging for screening angle closure diseases Andrew Winegarner1,, Atsuya Miki1, Miho Kumoi1, Yuchiro Ishida1, Taku Wakabayashi1,

Slides:



Advertisements
Similar presentations
Comparison of Endothelial Cell Count by Manual and Automated Methods in Normal Corneas and in Fuchs' Endothelial Dystrophy Somasheila I Murthy, Debarun.
Advertisements

J Glaucoma Volume 20, Number 5, June/July 2011 R1 何元輝 2011/09/15 EBM discussion.
Eugene Ng, Arthur B. Cummings, Patrick P. Collins, Alexander V. Goncharov, Diana Bogusevschi, Chris Dainty, Michael C. Mrochen. The authors of this paper.
Anterior Chamber Depth, Iridocorneal Angle Width, and Intraocular Pressure Changes After Phacoemulsification: Narrow vs Open Iridocorneal Angles Huang.
Phacoemulsification with Goniosynechialysis in the Management of Refractory Acute Angle-closure Glaucoma Ghasem Fakhraie*, MD, Mahmoud Jabbarvand, MD,
David Zadok MD, Isaac Avni MD
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group The impact of reference body selection for calculating.
Repeatability of Anterior and Posterior Corneal Higher- Order Aberrations in 4 mm, 6 mm and 8 mm diameters measured by Pentacam System Jadwiga Wojtowicz.
REFERENCES 1.Roberts E, Morgan R, King D, Clerkin L. Funduscopy: a forgotten art? Postgrad Med J. 1999; 75: McComiskie JE, Greer RM, Gole GA.
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
Dept. of Ophthalmology, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany. Outcome after big-bubble deep anterior lamellar keratoplasty.
Abstract ID 1196 CT volumetry of adrenal glands in normal subjects.
Biometric Accuracy in High Hypermetropes and Myopes
Cataract Surgery After Trabeculectomy: The Effect on Trabeculectomy Function Husain R, Liang S, Foster PJ. Cataract surgery after trabeculectomy: the effect.
Phoebe D. Lenhart, M.D. 1, Amy K. Hutchinson, M.D. 1, Michael J. Lynn, M.S. 2, Scott R. Lambert M.D. 1 1 Department of Ophthalmology, Emory University,
Khairidzan Mohd Kamal MD
Endothelial Keratoplasty in Patients With an Anterior Chamber Intraocular Lens: A Montreal Experience Georges M. Durr, MD 1,2 Johanna Choremis, MD, FRCSC.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
Introduction Left bundle branch block (LBBB) is notorious for obscuring the ECG diagnosis of acute myocardial infarction (AMI) and, therefore, the decision.
Prospective, Randomized, Double-Blind Study Comparing Nepafenac 0.1% (Nevanac™) and Bromfenac Sodium 0.09% (Xibrom™) in Post-Op Cataract Patients Hon-Vu.
Partial Coherence Interferometry Failure Rate in a Teaching Hospital Leslie A. Wei 1,2, BA, Nickolaus P. Katsoulakis 2, MD, Theodoros Filippopoulos 3,
Adriana S. Forseto1, MD Walton Nosé1,2, MD
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Minimizing Risk in Visian ICL Implantation.
COMPARISON AND EVALUATION OF OCULAR BIOMETRY USING A NEW NON-CONTACT OPTICAL LOW COHERENCE REFLECTOMETER David Goldblum 1,3, Kaspar Rohrer 1, Rudolf Waelti.
Ce Zheng 1, 2, 3, John Mark S de Leon 1, Carol Y Cheung 1, Arun K Narayanaswamy 1, Sim-Heng Ong 4, Clement W Tan 2, Paul T Chew 2, Shamira A Perera 1,
Genetic Susceptibility Variations and Visual Field Progression in Singaporean Chinese Patients with Primary Angle Closure Glaucoma 1 Duke-National University.
1. Ankara University School of Medicine, Department of Ophthalmology
SUBACUTE ANGLE CLOSURE MISDIAGNOSED AS MIGRAINE / CHRONIC HEADACHE IN MIDDLE AGED SOUTH INDIAN POPULATION Poornima Kandasamy1, Ajita Sasidharan1 1Glaucoma,
Use of the ICare Home Rebound Tonometer for home self-monitoring of intraocular pressure in a Singaporean population Jeanne Joyce OGLE1, Wai Cheng SOO.
iStent with phacoemulsification, n=50
Anterior Segment OCT in Strabismus
The effects of Nd:YAG (neodymium: yttrium-aluminum-garnet) laser peripheral iridotomy (PI) on contra-lateral eye anterior chamber parameters of patients.
OCULAR FINDINGS OF SCHOOL SCREENING AND EYE CAMP IN NEPAL
Tulsi Changulani 1,*, Jenny Bo 2, Mei-Ling Cheng 1, Andrew Tatham 1
Selective laser trabeculoplasty in Korean eyes with medically uncontrolled pseudoexfoliation glaucoma Su Chan Lee1, Jung Hyun Lee1,
Comparison of Endothelial Cell Loss After Phacoemulsification Performed by Third Year Residents and Anterior Segment Surgeons Alexandra Braunstein, MD.
Peters’ anomaly: A Clinical Study of 36 Patients
Characteristics of Primary Angle-Closure Glaucoma Patients with Normal Intraocular Pressure at the First Visit Won Hyuk Oh1, Bum Gi Kim1, Joo Hwa Lee2.
Understanding Barriers to Access to Eye Care in Western India
Optical coherence tomography in the diagnosis and managment
Safety of medication reduction for Primary Angle Closure (PAC) –
Diabetes and Hypertension Health Screening in the Fresno Sikh Population: A Cross Sectional Approach Baljit Singh Dhesi 1,2 1University of California,
Early Intraocular Pressure Rise After Phacoemulsification In Non-Glaucomatous And Eyes With Primary Open-Angle Glaucoma Milos Todorovic 1, Suncica Sreckovic.
Purpose Results Results Methods Conclusion
Measurement of 60 kHz Femtosecond LASIK Flaps with Anterior Segment Ocular Coherence Tomography & Ultrasonic Subtraction Pachymetry Edward E. Manche, MD.
B. Kozomara, E. Potkonjak, R. Lazic, N. Gabric
Structure-Function Relationship Between the Bruch Membrane Opening-based Minimum Rim Width and Visual Field Defects in Advanced Glaucoma Serhat Imamoglu,
Maria A Henriquez MD Luis Izquierdo MD Jackeline Parraga MD
EVIDENCE LEVEL III CONFIRMATORY
Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation Zina Zhang MD1, Logan.
References: Available upon request
Comparison of Single-Scheimpflug and Dual-Scheimpflug Pachymetry Measurements and Effect of Decentration World Cornea Congress VI April 7-9, 2010.
Terson Syndrome: a prospective analysis of 45 consecutive patients
Comparison of anterior and posterior polar cataracts with novel Scheimpflug images  Shafi Balal MBBS, Anant Sharma MD, Nisha Nesartanam MBBS, Jonathan.
39 DEVELOPED HCC by EASL criteria
FAMILY MEDICINE AND LABORATORY TESTS Elham
David B Henson Medical School University of Manchester
Johnson CH TAN, MBBS, MRCSEd(Ophthalmology)
Mehdi Ghajarnia, MD Mark Mifflin, MD John A. Moran Eye Center
Comparison of corneal powers obtained from four different devices
Screening, Sensitivity, Specificity, and ROC curves
Associate Professor of Ophthalmology
Vicente J. Correa-Gomez MD, Guillermo Tapia MD, Oscar Macias Manuel MD, Alejandro Navas Perez MD, Gilberto Islas MD, Tito Ramírez-Luquin MD, Enrique O.
Yumiko Ban,1,2,3) Seika Den,2) Jun Shimazaki,2,3)
New 3-Dimensional Scheimpflug Analysis of Cataract Density
Bernilla E; Izquierdo Jr. L; Miranda M.
Joshua C. Teichman, MD Richard Lee, MD Andrea Butler, BSc
Khairidzan Mohd Kamal MD
International Vision Correction Research Centre
Presentation transcript:

Anterior segment Scheimpflug imaging for screening angle closure diseases Andrew Winegarner1,, Atsuya Miki1, Miho Kumoi1, Yuchiro Ishida1, Taku Wakabayashi1, Shinichi Usui1, Kenji Matsushita1, Kohji Nishida1 1Department of Ophthalmology Osaka University Graduate School of Medicine Introduction Results PACG affects approximately 0.75% of all adult Asians with rates doubling every decade, and affects 0.4% of all European-descent adults over the age of 40 Gonioscopic examination is the gold standard for the diagnosis of PACG. However, it requires a highly-trained ophthalmologist, direct contact with the eyeball, and results are not easily reproducible by unskilled examiners. Anterior segment Scheimpflug imaging offers a noninvasive means to quantitatively assess anterior chamber parameters in an automated and standardized manner. Technicians would require minimal training and be able to screen and refer suspected cases of PACG to an ophthalmologist for proper diagnosis. Normative data on anterior chamber parameters such as depth, volume, and angle have been generated from two previous studies and included in the Pentacam Scheimpflug imaging device. Patient’s individual data may be analyzed against the normative data directly on the device. We have used the normative data as screening tool on our own patient population to both further validate the normative data, and test the feasibility of establishing a screening protocol. We generated our own normative data for comparison with previous normative data. 2 Representative control case for Scheimpflug imaging data page Representative patient case for Scheimpflug imaging data page Normative Data Screen Methods & Materials 88 consecutive patients with gonioscopy-diagnosed angle closure diseases (PACS, PAC, and PACG) and Scheimpflug imaging data were retroactively surveyed. 35 healthy control subjects were analyzed via Scheimpflug imaging for comparison. The analyzing software of the Pentacam Scheimpflug imaging device provides threshold values (standard deviations) based on the normative data. We used 1 SD from the normative mean values (depth ≤ 2.37mm, volume ≤ 111 mm2, and angle ≤ 31degrees) as cut-off points for delineating between angle closure disease and those not at risk for PACG. The raw data from the present study was analyzed via ROC curves in order to generate new cut-off values to compare with previous studies’ sensitivity and specificity. Exclusion criteria included intraocular diseases such as a history of intraocular surgery, history of laser iridotomy, secondary glaucoma, and being over the age of 90 and under the age of 40. Cataract and epiretinal membrane cases were not excluded. Variables of age, axial length, spherical equivalent, ACD, ACV, and ACA were compared, with P-value less than 0.05 considered significant. ROC Curves TABLE 1. Clinical characteristics Total Angle Closure Control P Value Eyes / Subjects 122 / 122 87 / 87 35 / 35   Age, years (range) 72.1 ± 7.7 (49 – 87) 72.3 ± 7.7 (49 – 87) 71.6 ± 8 (56–87) 0.6403 Gender, female / male 80 / 42 62 / 25 18 / 17 0.037 Eye, right / left 64 /58 50 / 37 14 / 21 0.081 Axial Length, mm (range) 23.1 ± 1.5 (20.5 – 27.8) 22.5 ± 0.8 (20.5 – 24.4) 24.7 ± 1.6 (20.8 – 27.8) <0.001 Spherical equivalent refraction (range) -0.2 ± 3.1 (-10.6 – 5) 0.9 ± 1.9 (-5.4 – 5) -2.8 ± 4 (-10.6 – 4.4) Anterior chamber depth, mm (range) 2.12 ± 0.61 (1.26 – 3.97) 1.8 ± 0.27 (1.26 – 2.51) 2.92 ± 0.47 (1.97 – 3.97) Anterior chamber volume, mm2 (range) 88.8 ± 45.6 (29 – 244) 65.1 ± 17.3 (29 – 122) 147.7 ± 40.2 (75 – 244) Anterior chamber angle, degree (range) 25.0 ± 7.8 (9.2 – 45.7) 21.6 ± 5.7 (9.2 – 34.2) 33.7 ± 5.4 (20.8 – 45.7) Depth Volume  Table 2. Sensitivity and Specificity Sensitivity with 1 SD normative Specificity with ROC analysis Depth 97.7% 91.4% 95.4% 94.3% Volume 98.9% 71.4% Angle 88.5% 85.7% Angle Conclusions Previous studies’ normative data have been incorporated into the Pentacam Scheimpflug image analyzing software, so the technician may easily determine whether the values of the examined eyes fall within the normal limits (Fig. 1c). Technicians may noninvasively screen for angle closures with automated and standardized Scheimpflug imaging, which takes under 5 minutes per patient. Positive screens may be referred to an ophthalmologist for proper diagnosis via gonioscopy. In conclusion, our study clarified the excellent discriminative performance of the anterior segment Scheimpflug imaging parameters for angle closure diseases. Using the integrated thresholds generated from previous studies’ normative data, we accurately discriminated angle closure diseases from normal subjects. Our study confirmed the relevance of using these threshold values as screening tools in a large patient population, distinct from the one used in the normative data’s creation. Additionally, cut-off points generated from our own raw data yielded even better sensitivity and specificity. Our data strongly support the use of Scheimpflug imaging for screening angle closure diseases. References Study was undertaken to assess the discriminative power of anterior chamber parameters obtained with the anterior segment Scheimpflug imaging in screening angle closure diseases. Using 1 SD from the mean anterior chamber depth in normative data, angle closure patients were screened with a 97.7% sensitivity, and a 91.4% specificity. This study provides a larger population of patients with angle closure diseases than previous studies using anterior segment Scheimpflug imaging. It is the first study to validate the incorporated normative data with a separate patient population. Study’s limitation is all patients were taken from a university hospital setting, but we still believe these numbers to sufficient for screening purposes, especially given that the cut-off points used were not generated from the population being screened, excluding the possibility of an over-fitting. 1. S. Glaucoma is the second leading cause of blindness globally. Bull World Health Organ. 2004 Nov;82 (11): 887-8 2. Kingman Gupta P, Zhao D, Guallar E, et al. Prevelance of Glaucoma in the United States: The 2005-2008 National Health and Nutrition Examination Survey. Invest Ophthalmol Vis Sci. 2016 May; 57(6): 2577-2585 3. Cheng J, Zong Y, Zeng Y, et al. The Prevalence of Primary Angle Closure Glaucoma in Adult Asians: A Systematic Review and Meta-Analysis. Ed. Ted S. Acott. PLoS ONE. 2014 Jul 24;9(7) 4. Day A, Baio G, Gazzard G, et al. The prevalence of primary angle closure glaucoma in European derived populations: a systemic review. Br J Ophthalmol. 2012 Sep; 96(9):1162-7 5. Aung T, Friedman DS, Chew PT et al. Long-term outcomes in Asians after acute primary angle closure. Ophthalmology. 2004;111: 1464–1469 6. Weinreb RN, Healey PR, Topouzis F. Glaucoma Screening. World Glaucoma Association WGA Concensus series 5. 2008. 7. Foster PJ, Buhrmann R, Quigley HA, et al. The definition and classification of glaucoma in prevalence surveys. Br J Ophthalmol. 2002 Feb;86(2):238-42. 8. Thomas R, George R, Parikh R, et al. Five year risk of progression of primary angle closure suspects to primary angle closure: a population based study. Br J Ophthalmol. 2003;87:450–454. 9. Thomas R, Parikh R, Muliyil J, et al. Five-year risk of progression of primary angle closure to primary angle closure glaucoma: a population-based study. Acta Ophthalmol Scand. 2003;81:480–485. 10. Jain R, Grewal SPS. Pentacam: Principle and Clinical Application. J Curr Glaucoma Pract. 2009; 3(2):20-32 11. Georgios L, Maria G, Andreas K, et al. Anterior chamber volume measurements with Visante optical coherence tomography and Pentacam: repeatability and level of agreement. Clin Experiment Ophthalmol. 2009;37:772–774. 12. Shankar H, Taranath D, Santhirathelagan CT, et al. Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements. J Cataract Refract Surg. 2008;34:103–113 13. Kurita N, Mayama C, Tomidokoro A, et al. Potential of the pentacam in screening for primary angle closure and primary angle closure suspect. J Glaucoma. 2009 Sep; 18(7): 506-12 14. Hong S, Yi J, Kang SY, et al. Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography. Yonsei Med J. 2009 Aug 31: 50(4): 525-528 15. Grewal DS, Brar GS, Jain R, et al. Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles. Eye (Lond). 2011 May; 25(5): 603-11 16. Koç M, Özülken K, Ayar O, et al. Measurement of the anterior chamber angle according to quadrants and age groups using Pentacam Scheimpflug camera. J Glaucoma. 2013 Mar; 22(3): 226-9 17. Dabasia PL, Edgar DF, Murdoch IE, et al. Noncontact Screening Methods for the Detection of Narrow Anterior Chamber Angles. Invest Ophthalmo Vis Sci. 2015 Jun; 56 (6): 3929-35 18. Rabsilber TM, Khoramnia R, Auffarth GU. Anterior chamber measurement using Pentacam rotating Scheimpflug camera. J Cataract Refract Surg. 2006 Mar;32(3): 456-9 19. Pakravan M, Sharifipour F, Yazdani S, et al. Scheimpflug imaging criteria for identifying eyes at high risk of acute angle closure. J Ophthalmic Vis Res. 2012 Apr; 7(2): 111-7 20. R Core Team (2016). R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. URL https://www.R-project.org/. 21. Herman C. What makes a screening exam “good”?. Virtual Mentor 2006 Jan 1;8(1): 34-7