The easiest way to access Pure & Ultra Pure Water from tap

Slides:



Advertisements
Similar presentations
Instructional Presentation
Advertisements

WHO - PSM Water –part 3 Workshop on GMP and Quality Assurance of HIV products Shanghai, China 28 Feb - 4 March 2005 Maija Hietava M.Sci.Pharm Quality Assurance.
Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank.
Dialysis Water Treatment Systems
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
The pumps should be tightened about once a month. If a new pump is installed, the pump should be initially tightened and then re-torqued one week later.
Tools Material Pre-Assembly Assembly Purpose Test 4/24/2015 JTOT Jet A – Thermal Oxidation Test Training Memphis Refinery Lab Tools Material Pre-Assembly.
ClearWater Tech LLC EcoTex - Advanced Laundry Oxidation Systems Ozone Laundry Methodology.
FoamPro 1600 Series Fully automatic Class A foam ONLY
Summit E & Summit XL Dispensers for small OPL to large laundry washer extractors and tunnels.
Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions VWR Set Up 12 groups Mira Costa kit.
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube.
LSRII Troubleshooting Tips
Power-Fill Operation Demonstration Power-Fill Operation Demonstration (See Installation and Operation Manual for detailed instructions)
Millipore DI Water Purifier Ron Kmak, Zeljko Matijas, Laura Skubal, Dean Walters, and Bob Wagner 28 September 2011.
FILTERING MDP. Safety and Safety Gear  When filtering from a fermentation vessel you should never use carbon dioxide to push the beer through the filter,
AccuMax Multi-Point Injection Mechanics
Information about Purified water Ten steps to Purified Water Photos of Purified water in process Conclusion.
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
No Metal; All Glass aquarium Do not use tap water because it could have metal in it. “ Universal solvent” holds salts in solution chlorine can evaporate.
1. Footer Date CPP OWS and Filters Chicago Pneumatic People. Passion. Performance.
Presented by Steven P. Feltman Food Safety and Quality Specialist.
Scout Pro Training Introducing the Scout Pro Portable Balance: 7 Models From 200g x 0.01g to 6000g x 1g 5 Application Modes Optional USB or RS232 Interface.
TrueSTEAM™ Humidification Systems Module 7: Maintenance and Service.
Training Session August 11, Nitro Express Features Probe or probeless operation from the same unit Compact splash resistant ABS enclosure Pre-wired.
CBS-7000 Series Coffee/Tea Brewers and Dispensers High Volume Brewing.
TrueSTEAM™ Humidification Systems Module 6: User Interface.
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
Honda factory, Guangzhou, China Objective: provide drinkable water to 5'000 employees.
Acidification of water to feed for lab animals System to acidify drinking water for lab animals, bench integrated with 60l tank for max 300l/h Space needed.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
STEP 1 Locate the transmission cooler line connection on the vehicle. Identify the correct adapters to be used by referring to the vehicle application.
STORAGE AND MAINTENANCE OF LARGE FARM EQUIPMENT Prepared by : Von G. Peavy South Region Ag Mechanics.
June 25, 2016 Centri-MAX10 Centrifugal Absolute Oil Cleaning System.
OSMOSIS. MEMBRANES ARE SELECTIVE PERMEABLE Many substances can diffuse (move) across biological membranes, but some are too big or too strongly charged.
"This document can not be used without Samsung's authorization"
BioTector COD TOC TN analyzer
The BioTector B7000i TOC analyzer with integrated oxygen concentrator
Manual Instructions Installation Cleaning Instructions
Quick Start Guide for Flex Flow Pump
RAINMAKER and RAINMAKER Enviro
Module 1: System Overview
Laboratory Glassware and equipment
Developing Film To develop your exposed film, you need to transfer the film from the film cassette into the light-proof processing tank. This needs to.
Provides a continuous supply of ready to use product on demand
Staying in Compliance: Spill and Overfill
GLASS RAINBOW SPARKLE.
Module 3 Domestic Heating/MMA Welding
Saeco Espresso Intuita Descaling
SB Packing Automatic Downpuller Power Unit
Module 1: System Overview
Troubleshooting 11/14/2018 Water King Service Seminar.
Part 2 – Supplied-air Respirators
Jet A – Thermal Oxidation Test Training Memphis Refinery Lab
Be Your Own First Tea Customer EVERYDAY!!!
Service Tips April 2005.
Jet A – Thermal Oxidation Test Training Memphis Refinery Lab
GLASS SPARKLE.
Maximum Contaminant Levels
Light Vehicle Diesel Engines
Universal Interrupted Electronic Oil Primary R7184U Training Module
Benzene in Water by Purge and Trap Analysis
Terry A. Ring Chemical Engineering University of Utah
BX-6WH / 8WH / 12 WH VIBRATORY PLATES.
Risk Management Student Powerpoint
Presentation transcript:

The easiest way to access Pure & Ultra Pure Water from tap Direct-Q 3 Direct-Q 3, the easiest way to access both pure & UPW from tap ! The easiest way to access Pure & Ultra Pure Water from tap

Introduction Movies to support you for the installation, the operation and the maintenance of a Direct-Q 3. Direct-Q 3, The easiest way to produce pure & ultrapure water from tap ! Throughout this presentation, we are going to show different movies which will support you for the installation, the operation & the maintenance of this system. It will be crystal clear at the end of this show that the DQ3 is the easiest way to produce pure & UPW from tap.

Direct-Q 3 Installation This combines 3 steps : The unpacking & installation of the system The SmartPak installation The connection of filters First of all, we are going to present the DQ3 installation. It consists of 3 steps: 1st- the system itself is unpacked and installed. 2nd- the Smartpak consumable is put in place. And 3rd- the different filters are connected. Each part is now going to be reviewed in detail…

Unpacking & Installing Our first movie is going to show how to unpack & install the system. Install the reservoir valve… and plug ! UV lamp easily accessible for future maintenance Quick Reference Guide always available with the system Just connect to the tap, secure the tubing to the drain…

SmartPak Installation Now the SmartPak is to be installed. Then an air purge and hydratuing phase will be performed. Lets see how it works.

SmartPak Installation Close the valve and allow the tank to fill up for 1h Let flush the pack for 15 min Always wet de SmartPak O-rings Open the reservoir valve Easy positioning of the Smartpak !

SmartPak Purging & Hydrating Start production until the reservoir is empty Connect the Point-Of-Use to the drain

Filters Connection Vent filter connected at the back of the system Final step of the installation: the vent filter and the point-of-use filter have to be connected. Vent filter connected at the back of the system Let produce 1L of water to flush & hydrate the filter New point-of-use filter connection Start production & vent the filter

2 water qualities available : Direct-Q 3 Operation 2 water qualities available : Type 3 from reverse osmosis stored in 6L internal reservoir. Type 1 after the polishing cartridge : dispensed at the point of use We are now going to operate the DQ3 we have just installed. We remind you this system produces 2 types of water: Type 3 water from reverse osmosis technology. It is stored in its 6L internal reservoir. Type 1 UPW dispensed at the point-of-use The next films will show how to access these purified waters.

Accessing Type 3 Water in the Internal reservoir Depending on the system installation, the type 3 water access can be different Reservoir valve integrated in the wall mounting bracket Reservoir valve available nearby the system, on the bench

Delivering Type 1 Water at Point Of Use The UPW is delivered at the POU after a brief recirculation step… Before producing type 1 water, allow internal water to recirculate Press once on the trigger to dispense the ultra pure water Check volume in reservoir… then press again to stop dispensing

The Ultra Pure Water Volumetric Dispensing The UPW is delivered at the POU after a brief recirculation step… Enter the appropriate mode FO1 Choose the required volume pressing + or - key Start UPW production : the system automatically dispenses the expected volume

Direct-Q 3 Maintenance A maintenance greatly simplified ! 3 STEPS ONLY ! Changing the SmartPak & Filters Replacing the UV Lamp Sanitizing the reservoir Similarly to the installation & operation, the maintenance of the DQ3 has been greatly simplified in order to make the customers’ work easier & quicker. It only consists of 3 steps which are going to be described in details through the following slides.

SmartPak Replacement 1st step, the replacement of the SmartPak when the system asks for it. Flush 15min to the drain then refill the reservoir Replace the old pack & drain the reservoir The red SmartPak icon flashes as an indicator

UV Lamp Replacement (once every 2 years) 2nd maintenance operation : the UV lamp replacement every 2 years. The system will also specifically ask for it. This step is always followed by the UV lamp timer resetting. Gloves to protect the lamp integrity Goggles in case of glass break The red UV lamp icon flashes as an indicator In the C05 mode, reset the timer for the next UV reminder to be on-time

Internal Reservoir Sanitization Finally the customers can sanitize the DQ3 internal reservoir. Millipore recommends such a cleaning once every year, particularly for customers’ applications sensitive to microbial contamination. To efficiently rinse, refill the tank then empty it again Let the system fill the tank - wait for 1 hour, then drain Chemical sanitant = Hydrogen Peroxyde 30% & purified water The ‘sanitization kit’ includes the necessary accessories By the vent filter access, inject 100mL of chemical then 100mL of pure water

Conclusion Easy to install Easy to operate Easy to maintain And good looking ! The Direct-Q 3 is THE solution for customers needing low volumes of Pure & Ultra Pure Water from tap ! Easy to install. Easy to operate. Easy to maintain. And good looking !!! The DQ3 is THE solution for customers needing low volumes of both pure & UPW water from tap. Thank You.