CENTIFUGAL PUMP OPERATION

Slides:



Advertisements
Similar presentations
Service Delivery 3 Pumps.
Advertisements

SAMPLE SLIDES OF THE 1-DAY SEMINAR FOR PUMP USERS
CHE Pumps and gas moving equipment  For the fluid flow from point to another, a driving force is needed.  The driving force may be supplied by.
Pumps, Compressors, Fans, Ejectors and Expanders
Our Plan – Weeks 6 and 7 Review energy relationships in single pipes Extend analysis to progressively more complex systems – Pipes in parallel or series.
HYDRAULIC DESIGN.
Water Pumps turbo-hydraulic pumps, positive-displacement pumps.
Pump Basics. Centrifugal Pumps From the Center of a Circle RADIAL DIRECTION To the Outside of a Circle A machine for moving fluid by accelerating the.
PUMPS, VALVES, & FANS …Moving fluids Objectives Comprehend the basic construction and application of valves used Comprehend the basic construction and.
Pump Installation Vigyan Ashram, Pabal.
The Centrifugal Pump.
Lesson 26 CENTRIFUGAL PUMPS
Pacific school of Engineering , surat A Presentation on
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement.
After successfully completing this lesson, you will be familiar with:  Head-Flow Curves  Power-Flow Curves  Net Positive Suction  Head  Cavitation;
Components of Centrifugal pumps
DESIGN AND CONSTRUCTION OF AN INDUCTION FURNACE (COOLING SYSTEM) Presented by MG THANT ZIN WIN Roll No: Ph.D-M-7 Supervisors : Dr Mi Sanda Mon Daw Khin.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
Dr. subhash technical campus
To prevent cavitation:
Fluid Mechanics and Applications Inter American Chapter 7 MEEN 3110 – Fluid Mechanics and Applications Fall Lecture 07 CENTRIFUGAL PUMP CHARACTERISTICS.
Presentation prepared by: Nimesh Gajjar
Metso - Slurry Pumping.
Quadna Field Installation Expert Field Installation Including Start-up and Commissioning Field Service Quadna Field Installation Expert Field Installation.
Process Design CEN 574 Spring 2004
PRESENTED BY : N.SRIKAUSIGARAMAN
SUBJECT CODE NAME OF SUBJECT TOPIC :::::: FLUID POWER ENGINEERING CENTRIFUGAL PUMP Parul Institute of Engineering & Technology.
Parul Institute of Technology
Parul Institute of Engineering & Technology Subject Code : Name Of Subject : Fluid Power Engineering Name of Unit : Pumps Topic : Reciprocating.
Urban Storm Drain Design: Multiple Pumps. Multiple Pumps The HDM and FHWA recommend more than one pump Redundancy Flexibility Ability to manage flows.
A Primer on Pumps Shenandoah Valley December 2, 2015.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
Parul Institute of Engineering & Technology Subject Code : Name Of Subject :Fluid Power Engineering Topic :Rotodynamic Pumps.
Introduction to Energy Management
1 ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 6 : PUMPS.
FLUID FLOW FOR CHEMICAL ENGINEERING Dr Mohd Azmier Ahmad Tel: +60 (4) EKC 212 CHAPTER 8 (Part 5) TRANSPORTATION SYSTEM.
CENTRIFUGAL PUMPS:- DESIGN & PERFORMANCE Ir. N. Jayaseelan 2012.
A Presentation on Centrifugal pumps
A.D PATEL INST OF TECH. NAME : SETA BHAUMIK D. ( ) TOPIC : CENTRIFUGAL PUMPS FACULTY : BHAUMIK SHETH.
SUDHIR REDDY S.V.R M.TECH(CAD/CAM)
Chapter 10: Flows, Pumps, and Piping Design
Fluid Mechanics for Chemical Engineers Arif Hussain (Lecturer)
Power Consuming Fluid Machines BY Dr. P M V Subbarao Mechanical Engineering Department I I T Delhi Small Things Make Huge Events possible!!!
PUMPS Thermal Systems Laboratory Samuel A. Santiago Pérez Modesto González David Alvarado.
System One Pumps S1-200 Centrifugal Hydraulics
Week 1 Unit Conversions Conservation of Mass Ideal Gas
Deptt. of Irrigation and Drainage Engineering, Dr. PDKV, Akola
Components Pumps.
CE 3372 Water Systems Design
pumps Principle of operation of a pump: Classifications of pumps:
EXECUTIVES & NON-EXECUTIVES
CENTRIFUGAL PUMP TROUBLESHOOTING
Pumps Outline: Where are pumps used
ME444 ENGINEERING PIPING SYSTEM DESIGN
ITEMS TO CHECK ON Running Pumps
Lecture 15 TDH and NPSH Dr. C. L. Jones Biosystems and Ag. Engineering.
System One Pumps Selecting Centrifugal Pumps S1-201
Review from Lecture 1: Pumps
BAE4400 Topics in Processing
SIMILARITY AND DIMENSIONLESS GROUPS
Review from Lecture 1: Pumps
Review from Lecture 1: Pumps
Performance Curves Dr. C. L. Jones Biosystems and Ag. Engineering.
4.6 Cavitation Since NPSHav. is the absolute pressure available less the vapor pressure of the liquid, the NPSHav. should always be greater than the NPSHreq.
Pumps and pumping station
Presented By: Vinod Dahiya Lecturer Mechanical Engg. RGGP Narwana.
Introduction to Fluid Mechanics
Hydraulic Pump Power Power = rate of conversion of energy.
PUMPS AND DRIVERS NCCER
Presentation transcript:

CENTIFUGAL PUMP OPERATION

Static Suction Head

Some Important Terminologies Static Suction Lift The distance measured vertically the intake of the pump or the pump is placed above the surface of the liquid in the suction tank. Static Suction Head The distance measured vertically the pump is placed below the surface of the liquid in the suction tank. Static Discharge Head The distance measured vertically the pump is placed below the surface of the liquid in the discharge tank. Total Static Head The vertical distance from the surface of the liquid in the suction tank to the surface of the liquid in the discharge tank. TSH = SSL + SDH TSH = SDH - SSH

Velocity Head The energy required to put the liquid in motion. Pressure Head The energy required to impart additional pressure on the liquid to overcome the system pressure. Friction Head The amount of energy required to overcome resistance in the pipes, valves and fittings. Total Dynamic Head The sum of velocity, pressure and friction head. In the suction line it is called DSH In the discharge line it is called DDH Total Head The total energy required to move the fluid from the suction to the discharge point. It is the sum of static and dynamic head.

CENTRIFUGAL PUMP OPERATION Cavitation Definition of cavitation Effect of cavitation on pump performance Indication that a centrifugal pump may be cavitating Steps that can be taken to stop pump cavitation How to avoid pump cavitation

Definition of cavitation The process of the formation and subsequent collapse of vapor bubbles in a pump is called cavitation.

Effect of cavitation on pump performance Three effects of pump cavitation are: Degraded pump performance resulting in a fluctuating flow rate and discharge pressure Excessive pump vibration Destructive to pump internal components (damage to pump impeller, bearings, wearing rings, and seals)

Pressure profile inside a centrifugal pump.

Cavitation damage on an impeller The shock of the imploding bubbles on the surface of the vane produces a gradual erosion and pitting which damages the impeller. Cavitation damage on an impeller

Erosion of the blades of the mixed flow pump impeller

Indication that a centrifugal pump may be cavitating There are three indications that a centrifugal pump is cavitating. Noise Fluctuating discharge pressure and flow Fluctuating pump motor current

Steps that can be taken to stop pump cavitation Steps that can be taken to stop pump cavitation include: Increase the pressure at the suction of the pump. Reduce the temperature of the liquid being pumped. Reduce head losses in the pump suction piping. Reduce the flow rate through the pump.(reduce NPSHR ) Reduce the speed of the pump impeller. (reduce NPSHR )

How to avoid pump cavitation To avoid cavitation in centrifugal pumps, the pressure of the fluid at all points within the pump must remain above saturation pressure. This can be achieved if: The net positive suction head available must be greater than the net positive suction head required. NPSHA > NPSHR

If the head losses in the pump suction piping can be reduced, the NPSHA will be increased. Various methods for reducing head losses include increasing the pipe diameter, reducing the number of elbows, valves, and fittings in the pipe, and decreasing the length of the pipe.

Calculation of the net positive suction head available NPSHA

Gas Binding (in systems containing dissolved gases) Gas binding of a centrifugal pump is a condition where the pump casing is filled with gases or vapors to the point where the impeller is no longer able to contact enough fluid to function correctly. The impeller spins in the gas bubble, but is unable to force liquid through the pump. Effect of gas binding This can lead to cooling problems for the pump's packing and bearings.

To avoid gas binding Centrifugal pumps are designed so that their pump casings are completely filled with liquid during pump operation. Pumps in systems containing dissolved gases that are not designed to be self-venting should be periodically vented manually to ensure that gases do not build up in the pump casing.

Pump Priming Methods of Priming Definition: Filling the pump casing and the suction line with the liquid being pumped. Methods of Priming 1- If the pump is above the source of supply close the discharge valve and open the suction valve. Open the air vent valves to allow the air in the pump casing to escape. When water flows from the vents, they can be closed and the pump is then in primed conditions and ready for starting

2- If the pump is above the source of supply

Fig. a The priming water comes from an external source. The discharge valve is closed and the external supply valve is opened as are the vent valves. The water flows into the pump and into the suction line where it is prevented from escaping by the foot valve. The water fills the suction line and then the pump casing. When water flows from the vent valves, they and the external supply valve are closed and the pump is ready for starting.

Fig. b The pump is primed by water which is supplied from the pump discharge line. The discharge valve is closed and the priming valve and the air vents are opened. Water from the discharge line fills the pump casing and the suction line. When water flows from the vents, the vent valves and the priming valve are closed and the pump is ready for starting.

3- Suction Lift Method

A separate hand operated priming pump (vacuum pump) is used. The main pump discharge valve is closed and priming pump valve is opened. The priming pump is operated and it exhausts air from the main pump casing and suction line causing water to fill them. When water flows from the priming pump discharge, then the priming pump is shut and the main pump is ready for starting.

Centrifugal Pump Characteristic Curves A vendor manual for a specific pump usually contains a curve of pump flow rate versus pump head called a pump characteristic curve. After a pump is installed in a system, it is usually tested to ensure that the flow rate and head of the pump are within the required specifications.

Shutoff head is the maximum head that can be developed by a centrifugal pump operating at a set speed. Pump runout is the maximum flow that can be developed by a centrifugal pump without damaging the pump. Centrifugal pumps must be designed and operated to be protected from the conditions of pump runout or operating at shutoff head.

Head Flow Pump performance curve Pump operating point System curve Static head Pump performance curve System curve Pump operating point

Centrifugal Pump Protection Centrifugal pumps must be protected from running dead head (shutoff conditions) and runout. One method for protecting the pump from running dead-headed is to provide a recirculation line from the pump discharge line upstream of the discharge valve, back to the pump's supply source. Centrifugal pumps must also be protected from runout. Runout can lead to cavitation. One method for ensuring that there is always adequate flow resistance at the pump discharge to prevent excessive flow through the pump is to place an orifice or a throttle valve immediately downstream of the pump discharge.