EE 369 POWER SYSTEM ANALYSIS
Lecture 3 Three Phase, Power System Operation Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
ECE 333 Renewable Energy Systems Lecture 13: Per Unit, Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
CHAPTER 9 Electrical Design of Overhead Lines
CHAPTER 9 Electrical Design of Overhead Lines
Announcements Be reading Chapter 3
Lecture 8 Transmission Lines, Transformers, Per Unit Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Lecture7 Development of Transmission Line Models Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
EE369 POWER SYSTEM ANALYSIS Lecture 6 Development of Transmission Line Models Tom Overbye and Ross Baldick 1.
Chapter 3Transmission Lines Why use high-voltage transmission lines? The best answer to that question is that high-voltage transmission lines transport.
Lecture 5 Power System Operation, Transmission Lines Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Pharos University EE-385 Electrical Power & Machines
Transmission Lines …….. Conductor Material
ELG4125 Transmission and Distribution Systems
Performance Equations and Parameters of Transmission Lines
Power Lines The power transmission line is one of the major components of an electric power system. Its major function is to transport electric energy,
ECE 476 Power System Analysis Lecture 6: Power System Operations, Transmission Line Parameters Prof. Tom Overbye Dept. of Electrical and Computer Engineering.
Announcements For lectures 8 to 10 please be reading Chapter 3
Announcements Please read Chapter 3 H4 is 4.34, 4.41, 5.2, 5.7, 5.16
ECE 476 Power System Analysis Lecture 7: Transmission Line Parameters Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
ECE 476 Power System Analysis Lecture 5:Transmission Line Parameters Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
Announcements Please read Chapter 4 HW 1 is due now
Lecture 6 Development of Transmission Line Models Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
ECE 576 – Power System Dynamics and Stability Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
Announcements Please read Chapter 3; start on Chapter 6
Lecture 6 Development of Transmission Line Models Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
EE369 POWER SYSTEM ANALYSIS Lecture 4 Power System Operation, Transmission Line Modeling Tom Overbye and Ross Baldick 1.
ECE 476 Power System Analysis Lecture 11: Ybus, Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
Announcements For lectures 9 and 10 please be reading Chapter 3
ECE 476 Power System Analysis Lecture 8: Transmission Line Parameters, Transformers Prof. Tom Overbye Dept. of Electrical and Computer Engineering University.
ECE 476 Power System Analysis Review 1 Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign
Announcements Read Chapters 8 and 9
ECE 576 – Power System Dynamics and Stability Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
Presentation Course: Power System Presented BY: M.Hamza Usman Roll No# BSEE Date: 10, November Section(B) To: Sir, Kashif Mehmood.
Lecture 5 Development of Transmission Line Models Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
1 Transmission of Electrical Energy Electrical energy is carries by conductors such as overhead transmission lines and underground cables. The conductors.
Announcements Please read Chapters 11 and 12
Announcements Please read Chapters 4 and 5 Quiz today on HW 2
Announcements Design Project has firm due date of Dec 4
Announcements Please read Chapters 8 and 9
Announcements Please read Chapters 9, 10 and 11 HW 8 quiz today
Announcements Please read Chapter 2.4, Chapter 6 up to 6.6
Announcements Please read Chapter 3
Announcements For lectures 7 to 9 please be reading Chapter 5.
Announcements Please read Chapters 4 and 5
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 Power System Analysis
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 Power System Analysis
ECEN 460 Power System Operation and Control
ECE 476 Power System Analysis
ECE 476 Power System Analysis
Module T1 Transmission Work problems 1, 2, 3, 6, 7, 8, 9 at end of Module T1. Turn in on Tuesday, Oct 24.
ECEN 460 Power System Operation and Control
ECE 476 POWER SYSTEM ANALYSIS
Electrical Capacitance
EE 483 Power System 1 Lecture 5: Chapter 4 T.L. Resistance and Inductance.
ECE 333 Green Electric Energy
ECE 333 Green Energy Systems
Exercise 10 Power systems.
ECEN 460 Power System Operation and Control
ECEN 460 Power System Operation and Control
ECE 333 Green Energy Systems
ECE 476 POWER SYSTEM ANALYSIS
Applied Electromagnetic Waves
ECE 476 POWER SYSTEM ANALYSIS
C H A P T E R 5 Capacitance. C H A P T E R 5 Capacitance.
ECE 476 POWER SYSTEM ANALYSIS
Power System Analysis (EELE 4351)
Presentation transcript:

ECE 476 Power System Analysis Lecture 7: Transmission Line Parameters Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign overbye@illinois.edu

Announcements Please read Chapters 4 and 5 (skim 4.7, 4.11, 4.12) HW 3 is 4.9 (use lecture results for 4.8 comparison), 4.12, 4.19 (just compare 4.19a to 4.19b), 4.25 It does not need to be turned in, but will be covered by an in-class quiz on Thursday Sept 15 Positive sequence is same as per phase; it will be covered in Chapter 8 Use Table A.4 values to determine the Geometric Mean Radius of the wires (i.e., the ninth column).

Birds Do Not Sit on High Voltage Lines

Voltage Difference

Voltage Difference, cont’d

Multi-Conductor Case

Multi-Conductor Case, cont’d

Absolute Voltage Defined

Three Conductor Case Assume we have three infinitely long conductors, A, B, & C, each with radius r and distance D from the other two conductors. Assume charge densities such that qa + qb + qc = 0 A B C

Line Capacitance

Line Capacitance, cont’d

Bundled Conductor Capacitance

Line Capacitance, cont’d

Line Capacitance Example Calculate the per phase capacitance and susceptance of a balanced 3, 60 Hz, transmission line with horizontal phase spacing of 10m using three conductor bundling with a spacing between conductors in the bundle of 0.3m. Assume the line is uniformly transposed and the conductors have a a 1cm radius.

Line Capacitance Example, cont’d

ACSR Table Data (Similar to Table A.4) Inductance and Capacitance assume a Dm of 1 ft. GMR is equivalent to r’

ACSR Data, cont’d Term independent of conductor with Dm in feet. Term from table assuming a one foot spacing

ACSR Data, Cont. Term independent of conductor with Dm in feet. Term from table assuming a one foot spacing

Dove Example

Line Conductors Typical transmission lines use multi-strand conductors ACSR (aluminum conductor steel reinforced) conductors are most common. A typical Al. to St. ratio is about 4 to 1.

Line Conductors, cont’d Total conductor area is given in circular mils. One circular mil is the area of a circle with a diameter of 0.001 =   0.00052 square inches Example: what is the area of a solid, 1” diameter circular wire? Answer: 1000 kcmil (kilo circular mils) Because conductors are stranded, the equivalent radius must be provided by the manufacturer. In tables this value is known as the GMR and is usually expressed in feet.

Line Resistance

Line Resistance, cont’d Because ac current tends to flow towards the surface of a conductor, the resistance of a line at 60 Hz is slightly higher than at dc. Resistivity and hence line resistance increase as conductor temperature increases (changes is about 10% between 25C and 50C, 0.4% per degree C) Because ACSR conductors are stranded, actual resistance, inductance and capacitance needs to be determined from tables.

Variation in Line Resistance Example

345 kV+ Transmission Growth at a Glance

345 kV+ Transmission Growth at a Glance Note that these facilities have exceeded their lives and key ones like the Mt Storm – Doubs 500kV line built in 1966 that Dominium announced is in need of replacment. Going to upgrade capacity using triple ACSR in lieu of double all alumimum conductors too. See 4/11 SNL article…

345 kV+ Transmission Growth at a Glance

345 kV+ Transmission Growth at a Glance

345 kV+ Transmission Growth at a Glance

Ameren Illinois Rivers 345 kV Project Ameren is in the process of building a number of 345 kV transmission lines across Central Illinois. Locally this includes a line between Sidney and Rising in Champaign County http://www.ilriverstransmission.com/maps

Sidney to Bunsonville 345 kV

Sidney to Kansas (IL) 345

Sidney to Rising 345 kV

Champaign-Urbana Part of Grid

Additional Transmission Topics Multi-circuit lines: Multiple lines often share a common transmission right-of-way. This DOES cause mutual inductance and capacitance, but is often ignored in system analysis. Cables: There are about 3000 miles of underground ac cables in U.S. Cables are primarily used in urban areas. In a cable the conductors are tightly spaced, (< 1ft) with oil impregnated paper commonly used to provide insulation inductance is lower capacitance is higher, limiting cable length

Additional Transmission Topics Ground wires: Transmission lines are usually protected from lightning strikes with a ground wire. This topmost wire (or wires) helps to attenuate the transient voltages/currents that arise during a lighting strike. The ground wire is typically grounded at each pole. Corona discharge: Due to high electric fields around lines, the air molecules become ionized. This causes a crackling sound and may cause the line to glow!

Additional Transmission Topics Shunt conductance: Usually ignored. A small current may flow through contaminants on insulators. DC Transmission: Because of the large fixed cost necessary to convert ac to dc and then back to ac, dc transmission is only practical for several specialized applications long distance overhead power transfer (> 400 miles) long cable power transfer such as underwater providing an asynchronous means of joining different power systems (such as the Eastern and Western grids).

HVDC Lines in North America http://www.grainbeltexpresscleanline.com/site/page/history_of_hvdc_transmission