MESH Crystal Injectors

Slides:



Advertisements
Similar presentations
Instrumental Chemistry
Advertisements

Research Instrumentation Special Interest Group Sensors & Instrumentation Knowledge Transfer Network Report on American Light Source Facilities Oliver.
Ultrafast Experiments Hao Hu The University of Tennessee Department of Physics and Astronomy, Knoxville Course: Advanced Solid State Physics II (Spring.
1 SpectroscopIC aNALYSIS Part 7 – X-ray Analysis Methods Chulalongkorn University, Bangkok, Thailand January 2012 Dr Ron Beckett Water Studies Centre &
Instrumental Chemistry Chapter 12 Atomic X-Ray Spectroscopic.
Mechanical and fluidic integration of scintillating microfluidic channels into detector system 1 Davy Brouzet 10 th September 2014.
Seminar Author: Bojan Hiti Mentor: doc. dr. Matjaž Kavčič Determination of trace impurities on Si wafers with x-ray fluorescence.
Birth of the X-Ray Laser and a New Era of Science Joachim Stohr
Chem X-ray Crystallography X-ray crystallography is an experimental technique that exploits the fact that X-rays are diffracted by the periodic.
P. Skopintsev1,2,3, A. Singer1, J. Bach4, L. Müller1, B. Beyersdorff2, S. Schleitzer1, O. Gorobtsov1, A. Shabalin1, R.P. Kurta1, D. Dzhigaev1,5, O.M. Yefanov1,
Frontiers of THz Science ZX Shen SLAC Chief Scientist 1.
Atomic Emission Spectra
Conclusions References 1. A. Galimberti et al., Nucl. Instrum. Meth. A 477, (2002). 2. F. Capotondi et al., Thin Solid Films 484, (2005).
Laserlaser. Laser printer Laser pointer Laser: everywhere in your life.
Santina Russo, Expose GmbH, September 2013 Enhancing the Drug Discovery Cycle Services in Protein Crystallography at the Swiss Light Source BioValley Life.
At XFELs Joachim Schulz Sample Delivery Methods for Biology Experiments.
Free Powerpoint Templates Page 1 Free Powerpoint Templates Protein Crystallization -by Creative Biostructure.
Anne-Charlotte Franc1, Aina Cohen2
The Electromagnetic Spectrum High Harmonic Generation
Mathematical Derivation of Probability
Jonathan Donkers1, Lin Zhang1+
Measuring the Thickness of Cryosheet Jets
Serial Femtosecond Crystallography
Madhu Karra1, Jason Koglin1,2
National SYNCHROTRON Radiation Centre SOLARIS Jagiellonian University, Krakow, Poland Piotr Goryl Motion Workshop, Soleil,
Image Processing For Soft X-Ray Self-Seeding
Structure and Function: Ubiquitination of NEMO and Optineurin
Characterizing Optics with White-Light Interferometry
Matter in Extreme Conditions at LCLS:
Kevin Shimbo1, Matt Hayes+
X-Ray Shielding Introduction Application Research Conclusions
Crystallography images
Hutch 4 (XCS) Laser System
MAKING WAY FOR LCLS II HERRIOTT CELL IGNIS THE NEED FOR LCLS-II
A remote EPICS monitoring tool
Designing and Prototyping Optics Table and Shelves
Managing Diffraction Beam
Integration of Blu-Ice into
Effects of Wrapping Vacuum
Scintillation Material Encapsulation Fixture
LCLS CXI Sample Chambers and Engineering Solutions
Values to Normalize Data
Designing a molecular probe for detection
LAMP Vacuum System Documentation
G6PD Complex Structural Study Crystallization Setup
Your Name, Elias Catalano, Robert Sublett, Robin Curtis
Determining a Detector’s Saturation Threshold
HXRSD Helium Enclosure
Crystallography Labeling Using Machine Learning
Structural study of soluble ammonia monooxygenase
Creation and development of a PRP database
IT Inventory and Optimization
Electro Optic Sampling of Ultrashort Mid-IR/THz Pulses
Margaret Koulikova1, William Colocho+
Analytical Solutions for Heat Distribution in KB Mirror Systems
Repeatability Test of Attocube Piezo Stages
Analytical Solutions for Temperature
Barron Montgomery1,2, Christopher O’Grady2, Chuck Yoon2, Mark Hunter2+
Elizabeth Van Campen, Barrack Obama2, Stephen Curry1,2, Steve Kerr2+
Advanced Methods of Klystron Phasing
Ryan Dudschus, Alex Wallace, Zachary Lentz
Jennifer Hoover1, William Colocho2
X-Ray Spectrometry Using Cauchois Geometry For Temperature Diagnostics
Redesigning of The SED Calendars
Automatic compression control for the LCLS injector laser
Russell Edmonds1, Matt Hayes2+ 1LCLS Summer Research Intern
Title of Your Poster Introduction Research Conclusions Acknowledgments
Reconstruction algorithms Challenges & Future work
Lab Equipment.
Presentation transcript:

MESH Crystal Injectors Development of LCP and MESH Crystal Injectors Megumi Tanaka1,2,3, Aina Cohen3 1Keio University, 2 Chome-15-45 Mita, Minato-ku, Tokyo 108-8345, Japan. 2Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA. 3Stanford Synchrotron Radiation Lightsource +Contact: acohen@slac.stanford.edu Introduction Macromolecular crystallography through X-ray diffraction analysis creates a 3D understanding of protein structures within crystals at an atomic level. The goal of my project is to develop and test two types of crystal injectors new to LCLS and SSRL, the MESH and LCP injectors. A crystal injector is a sample delivery device that produces a continuous liquid stream that contains micro-crystals. Efficiently collecting X-ray diffraction data from many small crystals, reduces radiation exposure to each crystal. The LCP injector uses gas pressure to drive a piston that pushes crystals that flow in a viscous (LCP) delivery medium, while the MESH injector uses high voltage (HV) to produce an electro-spray that propels crystals within various solutions. Our goal is to combine use of the mixing MESH injector with UV-visible absorption spectroscopy (UV-vis ABS) to simultaneously monitor the color (electronic state) of protein crystals and collect X-ray diffraction data to determine the corresponding protein structure. Keywords: Crystallography, crystal injectors, LCP, electro-spray, MESH Fig 5: Schematic view of UV-Vis ABS incorporated into a crystallography beamline at SSRL Fig 3: Schematic of LCP injector The LCP injector was developed as an alternative to the Gas Dynamic Virtual Nozzle (GDVN) injector, which is incompatible with protein crystals that grow in viscous mediums or for crystals in limited supply. All crystal injectors are useful for laser pump-probe experiments, but the MESH and LCP injectors have lower sample consumption than the earlier developed GDVN injector. LCP is a growth medium for membrane protein crystals, and was chosen as a delivery material to fill the high-viscosity injector because of its ability to grow well ordered crystals. Injectors are commonly used with very radiation sensitive crystals. At LCLS only one shot (of approximately 40 femtoseconds) per crystal can be applied, requiring a constant flow of new crystals. The diffraction pattern is collected before the crystal experiences significant radiation damage but it is destroyed in the process (diffraction before destruction). Proteins that bind the common biological chromophore retinal are ideal for time-resolved measurements, since they can be activated with a flash of laser light. At SSRL, crystals exiting the LCP injector will be exposed to a continuous beam of X-rays. Research 1 MESH injector The MESH injector is a new low flow delivery system for crystals in various solutions that uses high voltage (HV) to charge the carrier solution. A maximum of 5 KeV will be used. The charged crystal slurry travels from a syringe through a capillary. It exits the capillary and is propelled towards a grounded target. Before reaching the target, the sample is exposed to x-rays, creating diffraction patterns measured by an area detector. The uniqueness of the MESH injector is that it is a low flow injector that does not require viscous media. Therefore reactions within crystals may be triggered through solution mixing. The timing for these reactions can be adjusted for a more optimal experimental setup. Fig 6, 7: Absorption spectra from a MET myoglobin sample before and after X-ray exposure using UV-Vis ABS system controlled by the Blu-Ice software. After radiation exposure, the MET myoglobin is reduced.  Conclusions So far through my project I have gained substantial skills and knowledge on growing crystals, utilizing the UV-Vis ABS system using the Blu-ice software, and evaluating achieved sample spectra. For the remainder of my internship, I will work on testing a new MESH injector setup and monitor the spectra of solutions and crystals exiting the injector while determining and optimizing mixing times.  I will also work on setting up the LCP injector at SSRL BL12-2. Both the LCP and MESH injector hardware we are setting up are compatible with the MFX instrument at LCLS and can also be used at microfocus synchrotron beamlines such as SSRL BL12-2 and BL12-1 prior to LCLS beamtime. In the mixing MESH injector, a shorter capillary is inserted within a wider capillary, so the inner liquid mixes with the outer liquid according to the difference in capillary length. Acknowledgments Many thanks to the SMB group for being so welcoming and engaging throughout my internship, and special thanks to my mentor Aina Cohen for her support and guidance on my project, and Michael Soltis for his support on preparations for the LCP injector. Use of the Stanford Synchrotron Radiation Light Source, Linac Coherent Light Source (LCLS) and SLAC National Accelerator Laboratory, is supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences under Contract No. DE-AC02-76SF00515. Fig 4: Photo of ideal straight LCP jet 3. UV-Visible Absorption Spectroscopy Fig 1: MESH injector schematic UV-Vis ABS is useful to monitor the reactions occurring within crystals, and to verify the intermediate state of enzymes that change color during reactions. X-rays are used to obtain the structure of a sample, but even low doses of X-rays may cause local damage to the sample structure itself, such as photo-reduction of metal centers. Absorbance: The benefits of UV-Vis ABS include its speed and non-invasiveness, allowing for rapid monitoring of the protein state during X-ray diffraction experiments. To monitor the chemical state of metalloenzymes within the mixing MESH injector, reactions can be monitored using UV-Vis ABS. For our experiments, we will be setting up the mixing MESH injector at SSRL BL9-2 and will use an in-situ UV-Vis ABS system. 2 LCP injector References 1. Introduction to Macromolecular Crystallography (Alexander McPherson) 2. LCP injector for use in crystallography (Silje Skeide Fuglerud, Norwegian University of Science and Technology, Norway ) 3. Lipidic cubic phase injector is a viable crystal delivery system for time-resolved serial crystallography (Przemvslaw Nogly, others) 4. Concentric-Flow Electrokinetic Injector Enables Serial Crystallography of Ribosome and Photosystem-II (Raymond G. Sierra, others) 5. UV-Visible Absorption Spectroscopy Enhanced X-ray Crystallography at Synchrotron and X-ray Free Electron Laser Sources (Aina E. Cohen, Tzanko Doukova and S Michael Soltis) Fig 2: Main parts of the LCP injector in a disassembled state A) nozzle body B) reservoir C) hydraulic stage body D) piston Date: 08/28/2017