Do-more Technical Training

Slides:



Advertisements
Similar presentations
Copyright © 2005 Rockwell Automation, Inc. All rights reserved. 1 Micro Logix 1100 RSLogix 500 LAB#2 Timing, Counting & Comparing.
Advertisements

DNR-322L & DNR-326.
Introduction to MS Word 2007
Using Millennium Cataloging A Quick Drive through the Landscape.
Copyright © 2005 Rockwell Automation, Inc. All rights reserved. 1 Starting & Stopping Motors Micro Logix 1100 RSLogix 500 LAB#1.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
TUTORIAL # 2 INFORMATION SECURITY 493. LAB # 4 (ROUTING TABLE & FIREWALLS) Routing tables is an electronic table (file) or database type object It is.
Getting Started with Expression Web 3
Classroom User Training June 29, 2005 Presented by:
Microsoft Internet Security and Acceleration (ISA) Server 2004 is an advanced packet checking and application-layer firewall, virtual private network.
Otasuke GP-EX! Chapter 11 GP-Viewer EX
ADAM2 Single Remocon MCU IDE User’s Manual S/W Integrated Development Environment - Assembler - Simulator - Code Wizard V1.0 Technical Sales Team, ETA.
Session Objectives • Login to PeopleSoft Test Framework(PTF)
Copyright 2002, Paradigm Publishing Inc. CHAPTER 1 BACKNEXTEND 1-1 LINKS TO OBJECTIVES Worksheet Elements Worksheet Elements Worksheet Area Elements Worksheet.
VISTA IMAGING RADIOLOGY VIEWER. 2 The focus of this document is on the VistA Imaging Display Radiology Viewer. Other Display changes will be discussed.
Overview of MSWS Control of 212-LC July 15, 2006.
1 Micro Economix 1500 RSLogix 500 LAB#3 Sequencing and Subroutines.
Introduction to KE EMu
Microsoft Office 2013 Try It! Chapter 4 Storing Data in Access.
Word and the Writing Process. To create a document 1.On the Start menu, point to Programs, and then click Microsoft Word. A new document opens in Normal.
SNG via Webinar. Where’s Webinar??  Double click Aflac 2000 folder  Highlight “SNGWebCommunicator”  Right Click and “Send To - Desktop”
Do-more Technical Training Designer Basics. Programming Environment 1)Toolbar 2)Utilities 3)Tabs 4)Status.
MetaViewer Interface and Navigation start now. What is MetaViewer? Log On/Off to the system Main Window and Panes Master Index and Folder Pane Account.
Windows Server 2003 { First Steps and Administration} Benedikt Riedel MCSE + Messaging
5/14/2003Sprint TekNet IP Train the Trainer1 Open TekNet Software If working at a client station, enter the IP address of the server and mark page as a.
Enlisted Association of the National Guard of the United States Data Extract Instructional Guide.
Do-more Technical Training Connecting C-more. Two easy ways: ▫C▫Create TAGs manually ……in C-more Programming ▫C▫Create TAGs automatically ……by importing.
Chapter 5 Using a Template to Create a Resume and Sharing a Finished Document Microsoft Word 2013.
Pasewark & Pasewark 1 Windows Vista Lesson 1 Windows Vista Basics Microsoft Office 2007: Introductory.
Co-director CCNA CATC - Ft. Worth, TX
Do-more Technical Training
Do-more Technical Training
Eclipse EHX System Diagnostic tools
Standard Operating Procedure
Do-more Technical Training
Chapter 2: The Visual Studio .NET Development Environment
Do-more Technical Training
Do-more Technical Training
Production Maestro Training
Programming and Debugging with the Dragon and JTAG
Do-more Technical Training
Do-more Technical Training
Boeing 787 SCMP Training June 2016
Microsoft Outlook By: Phuong Nguyen.
Do-more Technical Training
Configuring Windows 10 for Your Studio
Eclipse Navigation & Usage.
3.14 Microscan QX-870 Scanner Configuration
Word and the Writing Process
GIS - NetmapWEB Training Slides
Central Document Library Quick Reference User Guide View User Guide
Office 2010 and Windows 7: Essential Concepts and Skills
MicroEconomix 1500 RSLogix 500 LAB#2
Cover page.
EndNote by: fatimah alotaibi.
MCS-Connect Change all frames to windows
Navigation Details Boeing 787 SCMP March 2018.
Do-more Technical Training
MicroEconomix 1500 RSLogix 500 LAB#1
Chapter 2 – Introduction to the Visual Studio .NET IDE
Do-more Technical Training
Introduction to EBSCOhost
Do-more Technical Training
Aleph Beginning Circulation
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Software Setup & Validation
Shelly Cashman: Microsoft Word 2016
Approving Time in Kronos Manager/Supervisor Reference Guide
Wings 2.0 Business Flow Reference
Microsoft Excel 2007 – Level 2
Presentation transcript:

Do-more Technical Training Designer Basics

Programming Environment Toolbar Utilities Tabs Status

Programming Environment Toolbars Offline Online Ladder File Edit Search View Tools PLC Debug Window Help

Programming Environment Utilities Launchpad Project Browser Debug View Data View PID Overview

Programming Environment Utilities Launchpad Projects Applications Links

Programming Environment Utilities Launchpad Projects Remove – Removes project from list and/or from disk Folders – Change project folder locations

Programming Environment Utilities Launchpad Applications Do-more Designer Do-more Logger

Programming Environment Utilities Launchpad Applications Do-more Designer Do-more Logger Displays debug & status messages received from Do-more CPU w/ Ethernet port. Packets are sent to UDP Port # 7272(hex) $EnableMsgDump (ST36) = ON to enable Very handy for troubleshooting EMAIL

Programming Environment Utilities Launchpad Applications Do-more Designer Do-more Logger NetEdit3 IPConfig Recover missing Ethernet device (NetEdit can’t see; IPX unavail) (1) Select Adapter at bottom (2) Get MAC address from device’s label (3) Enter MAC address in “Ethernet Address” (4) Enter “IP Address” you want missing device to have (must be on PC’s subnet) (5) “Subnet Mask” got set when Adapter was selected (but you can change it) (6) Press <Write> button  “Cool! Found device!” or “Sorry! Unable to find device!”

Programming Environment Utilities Launchpad Applications Visit Host Engineering Host Forum, FAQs, Downloads… Calculator Windows Network Control Panel Windows Firewall Windows Device Manager Windows Services CTRIO WB 2 – Do-more PLC CTRIO WB 2 – DirectcLogic PLC CTRIO WB 2 – Offline Do-more Designer Do-more Logger NetEdit3 IPConfig Do-more Version DmDesigner1_3.ini DMLoader DBWin32Logger ERM Workbench 205 Do-more Hardware Manual Terminator Do-more Manual Visit AutomationDirect

Programming Environment Utilities Project Browser Control Logic Configuration - Control Logic Filter - New Code Block - Execution Order - Status - Sort Code Blocks - Sort Memory

Programming Environment Utilities Project Browser BUTTONS - Execution Order - Status

Programming Environment Utilities Project Browser Control Logic Shows all Programs & Tasks Programs expand to show Rungs & Stages Tasks expand to show Rungs Shows first line of Comment Double-click opens code block in Ladder View When in Edit Mode, right- click on code block allows many functions (e.g. create, remove, etc.)

Programming Environment Utilities Project Browser Configuration: lists Data Blocks, Heap Items & Devices Memory – all memory types in System Configuration Devices – all system-created & user-created Devices in System Configuration, e.g. @CTRIO_001_C1F1 @IntEthernet @IntModTCPClient Unassigned Nicknames – any Nicknames not yet assigned to actual memory Have them open the Memory section Do System Configuration and configure the internal serial port to “General Purpose” Enter a STREAMIN (with Network Timeout set to 10 seconds) Enable STREAMIN (pull up the Device Status) to show the hotlink

Programming Environment Utilities Debug View Debug – enable Pause – stops scan Scan – starts scan Single Scan – runs one scan then pauses N-Scan – runs # of scans then pauses Stages – enable/disable Message Dump – enable to Do-more Logger app; sets $EnableMsgDump (ST36) = ON Watchdog… - test hardware or software watchdog Unsuspend, Unsuspend All, Suspend… - manually for Program or Task Enter INC D0 Put D0 in Data View to watch it increment Put $EnableDebug (ST33) in Data View Pull up Debug  Debug View Notice you can turn ST33 ON or OFF in Data View or in Debug View Turn it ON <Pause> … D0 stops incrementing <Scan> … D0 increments again <Single Scan> … D0 increments once Enter 10 into the N-scan variable <N-scan> … D0 increments 10 times Create MyTask task Program INC D1 Back in $Main, enter C0 to ENTASK “MyTask” (power flow, not edge) C0 = ON … D1 increments Debug mode <Pause> … D0 & D1 stop incrementing <Single Scan> … D0 & D1 increment by 1 <Scan> … D0 & D1 incrementing <Suspend…> MyTask … D1 stops incrementing (D0 keeps incrementing), MyTask is listed as suspended In Project Browser, MyTask (with status ON) shows yellow Select MyTask in Debug View, <Unsuspend> … D0 & D1 both incrementing Exit Debug

Programming Environment Utilities Data View Right-click

Programming Environment Utilities PID Overview

Programming Environment Tabs Top Start Page Ladder Views Trend Views PID Views Documentation Editor Bottom (dock/float) Cross Reference View Output Window

Programming Environment Tabs Top Start Page (Global) Customizable

Programming Environment Tabs Top Ladder View Individual tabs Re-orderable tabs Scroll (arrows/wheel) Search  Find (CTRL-F) Search  Goto (CTRL-G) View  Options  Ladder Hover Element (Xref w/links) Hover Instruction (Help w/links) View  Themes… View  Color Setup… Split screen bar Window  New Window, Cascade, Tile Horizontally, Tile Vertically, Arrange Icons Window  Default Layout (Recover!) View  Zoom In / Zoom Out (buttons / toolbar)

Programming Environment Tabs Top Ladder View Status bar Project Differences (hover) S = System Configuration P = Program D = Documentation Colors Green: not saved to disk Cyan: not saved to PLC Program Usage Used / Available Click for System Information Cursor Location <CodeBlock>#<Rung>:<Row>:<Column>

Programming Environment Tabs Top Trend View Logging / Historical Panes: Discrete Integers / Real Crosshair cursor Click for snapshot Zoom: CTRL + wheel Buttons: Opt – Trend View Options Hist – Toggle historical mode Exp – Export range of data points Sync – Synchronize time Rec – Record data to a file Pse – Pause recording Time Scale slider (500ms to 1 hour) Have them program a RAMPSOAK and use a system toggle bit (i.e. ST4 ($1second)) Pull up Data View with pertinent parameters Right-click on Data View and select Trend All Play with various things in Trend View

Programming Environment Tabs Top PID View Configuration, tuning & monitoring 3 panes Data form PV / SP trend Output / Bias trend

Programming Environment Tabs Top Documentation Editor Saved in the PLC PLC  System Information  Memory Usage box shows Max Documentation & Documentation Used Displays only used Element: program element (*) no documentation Nickname: 16 characters Extra Info: 16 characters Description: 132 characters CTRL-Enter manual line break Buttons: Add Record Add Sym Const – e.g. PI = 3.14159 Clean Database – remove records not being used Find Find Again

Programming Environment Tabs Bottom Dockable / Floatable Cross Reference View Tools  Cross Reference… or CTRL-Y Modes: (1) Xref mode (2) Usage mode

Programming Environment Tabs Bottom Dockable / Floatable Cross Reference View Modes: (1) Xref mode Element Extended Info – Structure member / Casting Access Type – Input, Output, In/Out Address - <CodeBlock>@<Address> Instruction Parameter Info – Instruction’s parameter Double-click places cursor

Programming Environment Tabs Bottom Dockable / Floatable Cross Reference View Modes: (1) Xref mode Buttons Follow Ladder Cursor Point Scope – Ladder View cursor itself Instruction Scope – Ladder View instruction Rung Scope – Ladder View rung Block Scope – Ladder View code block Full Scope – Entire project Include Bits Include Numerics Include Structures Include Devices Include Inputs Include Outputs Expand – include range entries (e.g. SETR “C100 thru C120”) Sort order – Element, Nickname, Data-Block/Number ID

Programming Environment Tabs Bottom Dockable / Floatable Cross Reference View Modes: (2) Usage mode Buttons Follow Ladder Cursor Reverse Usage Field Size 8 Field Size 10 Field Size 16 X = explicit use [ = start range ] = end range – = inside range

Programming Environment Tabs Bottom Dockable / Floatable Output Window Displays errors, warnings & info Can be activated by: Edit  Accept PLC  Program Check File  Import Search  Replace… Changes to System Configuration After PID Auto-tune Connecting to PLC Filter Buttons: Error, Warning, Message

Programming Environment Status Bar FUNCTION POSSIBLE VALUES APPEARANCE Writing to PLC N/A PLC writing ROM PLC Mode Switch Run, Term, Stop Force status Forces, Forces Suspended Project/PLC sync System (S), Program (P), Documentation (D) Device status Devs OK, Device Error PLC status PLC OK, Info, Warning, Error Session status Online-Offline/<user>/<link> PLC mode Run, Program Memory usage Program: <current>/<total> PLC type e.g. H2-DM1E Cursor position <CodeBlock>#<Rung>:<Row>:<Column>