CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS

Slides:



Advertisements
Similar presentations
K series for close control NEW C series for Close control.
Advertisements

Optimizing High Density Cooling Solutions for Data Centers
G.E. UPS Productline.
ZPAS Solutions for Data Center ZPAS GROUP ZPAS Solutions for DATA CENTER.
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.
Variable Frequency Drives VFD Basics
Delta Confidential Apr GAIA-series 5-11KVA Introduction.
Zycko’s data centre proposition The very best products and technologies Focus on what your customers need Turning products into solutions Wide range of.
Cooling Product Positioning
DPA TM UPScale Best-in-class modular UPS for maximum availability.
Data Centre World Expo 2009 Designing, building and operating high density data centres Kevin Sell Head of Technical Facilities, Telstra International.
CIT 470: Advanced Network and System AdministrationSlide #1 CIT 470: Advanced Network and System Administration Data Centers.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
September 18, 2009 Critical Facilities Round Table 1 Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure.
Campus Network Infrastructure Bangladesh University of Professionals(BUP) Prepared By: Mazharul Islam Tuhin.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
Confidential & Proprietary. What happens when Wind /Solar do not meet requirements? What next?
High Density Cooling Air conditioning for high density applications
Saving up to 60% of Energy With The Precision Cooling SmartAisle ™ Configuration.
Cooling: Best Practices and Economizers
Perfect solution for large building
Applying Precision Air Conditioning Systems
ENERGY of 21 st Century Independent Power Supplies.
Emerson Network Power Datacenter Infrastructure Solutions for Business Critical Continuity Many Needs, One Answer. May 28 th 2010.
COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.
Mission Energy: Energy Efficient Cooling How Data Centre energy consumption and operating costs can be significantly reduced through readily available.
PowerScale 10-50kVA Ed Maximize your availability.
Infrastructure Gina Dickson – Product Manager Kevin Jackson – Sales Manager.
Delivering total power infrastructures worldwide for IBM.
Schneider Electric: Total Cooling Solutions for Data Centers
1 BREC Air-cooled water chillers BREF Air-cooled water chillers with free-cooling system 1602A A A A A 3202A A A -
Energy Efficient Data Centre Design
Computing Facilities CERN IT Department CH-1211 Geneva 23 Switzerland t CF CERN Computer Centre Consolidation Project Vincent Doré IT Technical.
© Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. HP Restricted Data Availability.
We can…. 2 GLOBAL REFERENCES Rev: 00 References :
COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.
TGYDGL09 Project DEPLOYABLE RAPID DIAGNOSTIC LABORATORY MOBIOCHEM Ltd.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Row Cooling.
GEA Denco Close Control Climate control with the best in precision
PIC port d’informació científica First operational experience from a compact, highly energy efficient data center module V. Acín, R. Cruz, M. Delfino,
Altivar 32 So slim, So smart!
InfraStruXure Systems Alex Tavakalov
2016 Chiller New Products Presentation.
West Cambridge Data Centre Ian Tasker Information Services.
Setting up the Zeroth level of a Computational Grid Vincenzo Spagnoletti District Manager
I-RACH range I-RACH range I-RACH range I-RACH range High efficiency air/water heat pump with INVERTER scroll compressor Range Modularity Components Highlights.
Dell EMC Modular Data Centers
Poseidon 4002 Rack monitoring.
1-Port Ultra PoE to 4-Port 802.3af/at Gigabit PoE Extender
Avaya VA Line-interactive UPS
IP-based 8-port Switched Power Manager
Emerson Network Power Datacenter Infrastructure
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
CERN Data Centre ‘Building 513 on the Meyrin Site’
AdaptaPAK The sustainable, energy-efficient outdoor refrigeration solution.
PowerValue 11 RT Sales Presentation
True modular UPS system for critical applications
The Challenges of Electronic Enclosures for US Navy Ships
PowerValue 11/31 T Sales Presentation
Sunnytek sensor networks
Best-in-class modular UPS ensuring business continuity
HELIOS AMX5000 Minimax GmbH & Co. KG © Minimax 2009.
Data Centre Environment
Integrated data center unit
IT Wiring 综合布线.
Door Heat Exchanger: Specification

Presentation transcript:

CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS

Mobile (Container) DC Container DC is a method of deploying data centers that is designed to add data center capacity and to reduce an organization's cooling and power consumption costs Builds on capability of integrating cabinets, cooling, electrical distribution, sensors, and fire suppression systems into a single package

Why Container DC ? Rugged Containers Reduced CAPEX Energy Efficient Plug & Play Relocatable Fast time to execute Minimal use of space All in one DC

Canovate Mobile Data Center

From Concept to Reality

40 Foot Container painted to customer requirements. 4 by 28 KW outside compressor & condenser units supporting 4 DX based in row cooling systems. DX based eliminates links to a chiller. Caged for unauthorized access.

ROXTEC cabling entrances to ensure IP 65 rating.

Generator Unit Diesel generator based on customer requirement. 350 KW supplied based on customer requirement.

Sealed Entrance Door

Entrance Door Sensors Video based entry detection connected to EMS system for secure access. Smart card reader also installed with link to EMS system

Cold and hot aisles

Cold Aisle Sealed Cold Aisle Removable Panels 10 Cabinets 42U 600 * 1000 4 In Row Coolers Single 80% Perforation Doors Cold Aisle

Hot Aisle Sealed Hot Aisle Removable Panels Double 80% Perforation Doors Hot Aisle

Cabinet interiors

Cabinet with Mounting Rails and PDU’s Two PDU’s with Per Outlet Power (POP) switching 1500 KG Static Load AL Frame A and B feed for redundancy Monitored by EMS system Cabinet with Mounting Rails and PDU’s Depth adjustable mounting rails included

IP PDU’s with POPS Feature Per Outlet Power Sensing and Control  Integrated temperature and humidity sensors Wireless sensor connectivity -up to 9 sensors Industry leading accuracy level: 97% accuracy in measuring Camera connection capability 16

Cooling units

COLD AISLE CONTAINMENT + Gas Based DX (Refrigerant R 410) Front Cooler 28 kW cooling capacity in 42U 300x1000 Cabinet Automatically controlled between 11 to 28 kW by inverter technology for maximum energy efficiency COP ratio is above 4 for maximum energy efficiency External Compressor unit to have better noise level Cooling units work 100% sensible (without condensed water) Specially developed for cold & hot aisle containment applications Modular construction In-Row cooling technology Eliminating raised floor requirement Variable speed fans: EC-Technology Modular design: Allowing capacity expansion Hot-swappable fans Multipoint Injection System

Cooling Units N + 1 Redundant Design. (3+1)

Cooling Controller and Monitor Speed, alarms, thresholds

Hot Swappable Fans

sensors

Smoke Temperature, Humidity Sensors

Air Flow Sensor Opposite each In Row unit, additional check for fan performance

. Water Sensor Rope type water sensor

Environmental Monitoring System Designed to monitor the working environment and control access to electronic equipment in racks and data center applications Real time monitoring through LAN or WAN Monitoring technique based on SNMP Precision air conditioning system monitoring and management Security system monitoring Fire protection system monitoring and management Power consumption statistics and analysis Monitoring Master Unit Monitoring Master Unit with outlets

SNMP Environmental Monitoring System

Electrical

Modular UPS Solution Online Double Conversion Power rating ranges from 25kVA to 250kVA Possibility to connect two frames parallel to reach maximum 500KVA power Modular Design using hot-swappable power modules Intelligent Battery Management by DSP Intelligent Protection System 29

Modular UPS System Control Panel

Modular Power Distribution Panel Modular and Scalable Capacity up to 3200 A Shock-Safe Adding extra circuit without prior scheduling Temperature control Dielectric properties Short-circuit withstand Electrical distribution panel can be configured according to your datacenter power requirements 31

Electrical Distribution System Generator feeds EDS, power distributed to A and B UPS systems, from UPS, to IP PDU and In Row Cooling Electrical Distribution System

Fire suppression

Fire Suppression System

Fire Suppression System

Fire suppression nozzle – two each aisle

Battery backup

Battery Backup Cage

deployment

Ready for Deployment

Ready for Deployment

THANK YOU FOR YOUR ATTENTION QUESTIONS? 42