HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman
Advertisements

Heating, Ventilation, and Air-Conditioning (HVAC) Systems
Heating, Ventilating, and Air-Conditioning
Heating, Ventilating, and Air-Conditioning
Commercial Mechanical Requirements
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Heating, Ventilating, and Air-Conditioning (HVAC)
Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®
Foundations of Real Estate Management TM BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building.
Components of HVAC System
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
HVAC Heating, Ventilation and Air Conditioning -something that you never think about until it doesn’t work properly.
Chapter 6 Thermal Energy
Section 16.3 Using Heat.
Brought to you by: Connecticut Energy Code Frederick F. Wajcs Senior Energy Engineer Northeast Utilities February 10, 2011.
 Air conditioning Category: 1. Refrigeration cycle 2. Heat pump 3. Evaporative cooling  Refrigerants  Air conditioning system configurations  Refrigeration.
Important variables Water: Air: Conversion:
Announcements Midterm Project Prepare groups of 3 to 4 students You can submit the list at the end of next class Midterm Exam 03/09/10 - In class Exam:
5.3 Essential Questions What are the first and second laws of thermodynamics? How does an internal combustion engine work? How does a refrigerator work?
Section 3 Using Heat.
Heat engines played a key role in the development of the modern industrial world. Steam locomotives were an important early use of the steam engine. Electric.
Facilities Management and Design Chapter 7 HVAC Systems.
HEATING AND COOLING SYSTEMS
HEAT-GENERATING EQUIPMENT INTRODUCTION SELECTION EFFICIENCY FURNACES BOILERS CENTRAL HVAC SYSTEMS.
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
Warm-up: Predict whether leaving the refrigerator door open on a hot summer day will help to cool the kitchen. Explain your answer.
Chapter 5 – Thermal Energy
Maria’s Restaurant Chapter 2 Section 9
Maria’s Restaurant Lesson 18 Appendix A Zone 2 Equipment Loads
Maria’s Restaurant Chapter 2 Section 7
Maria’s Restaurant Chapter 1 Section 4
DESIGN AND DEVELOPEMENT OF AIR CONDITIONING CUM WATER COOLER
Section 6: Air-Conditioning (Heating And Humidification)
Welcome to the Colorado Restaurant Association Pikes Peak Chapter Energy Efficiency in the Restaurant Industry.
Maria’s Restaurant Chapter 1 Section 3
Maria’s Restaurant Chapter 3 Section 13
Technology in Architecture
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
Lesson 24 Appendix F Outside Air Calculation
BUILDING HEATING AND COOLING
Heating, Ventilating, and Air Conditioning
Heating Ventilating and Air Conditioning
Maria’s Restaurant Chapter 1 Section 2
High Temperature Reservoir Low Temperature Reservoir
Lesson 23 Appendix C Exhaust Calculation
Maria’s Restaurant Chapter 2 Section 8
HVAC EQUIPMENT General
Section 3: Using Thermal Energy
Electrical Gas Plumbing Heating & Cooling
5.3 notes What are the first and second laws of thermodynamics?
Heating, Ventilating, and Air-Conditioning
Chilled Beam Performance:
Bell work Predict whether leaving the refrigerator door open on a hot summer day will help to cool the kitchen.
Ch. 16 Sec. 3 Using Heat.
______________ Combustion Engine
Air Conditioning System-1
Flip The Long House Let’s imagine the Long house example in Manual J has undergone a house flipping/energy savings update. The insulation was increased,
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Mandatory Design Requirements
FBE03: Building Construction & Science
Announcements Exam 1 Next Class (Thursday, March 14th):
Objective Revie the Cooling Cycle Learn about air distribution systems
Refrigeration & Air conditioning
Maria’s Restaurant Chapter 1 Section 3
Maria’s Restaurant Chapter 2 Section 7
Maria’s Restaurant Chapter 2 Section 9
Maria’s Restaurant Chapter 2 Section 8
Lesson 24 Appendix F Outside Air Calculation
Maria’s Restaurant Chapter 1 Section 2
Presentation transcript:

Maria’s Restaurant Chapter 2 Section 6

Manual CS Commercial Applications, Systems and Equipment

Heating Equipment Selection Forced Air Fossil fuel furnaces (gas or oil) Stoves burning wood or fuel pellets Air source heat pump Electric furnace or resistance heat Geothermal or water source heat pump Variable refrigerant flow Hydronic Heat Boiler (hot water or steam heat) Electric water heater Fossil fuel water heater

Cooling Equipment Selection Forced Air Electric Air Conditioner Air source heat pump Evaporative Cooler (Swamp cooler) Geothermal or water source heat pump Chilled water Variable Refrigerant Flow Hydronic Cooling Radiant Chilled Beam

Designer Needs To Know Cooling/heating airflow – Generally expressed in these blower speed intervals: Low - High, Low – Medium – High, Low – Medium Low - Medium High - High. Variable (Continued next page)

Designer Needs To Know Outdoor air temperature – This is the temperature of the air around the outdoor condensing coil*, sometimes called the condenser air temperature. (Keep in mind this temperature may not exactly match what is listed on the manufacturer’s data, so we may have to interpolate.) Condition of air entering the indoor coil – OEMs use either a dry bulb temperature, a wet bulb temperature, or may ask for some dry bulb – wet bulb combination. *Note: The temperature of the air at the outdoor coil may be warmer than the outdoor temperature if the equipment is on a flat, black roof or near masonry walls, etc.

Cooling Design Information

Heating Design Information

Zone 1 Dining Area Sketch

Zone 2 Kitchen Area Sketch

Sizing for Cooling Indoor Design = 75OF and 50% RH; Outdoor Design = 88OF and 70OF WB; Entering Dry Bulb = 77OF; Entering Wet Bulb = 64 OF Zone 1: Zone 2: Sensible Load = 50,185 Btuh Sensible Load = 96,495 Btuh Latent Load = 21,481 Btuh Latent Load = 19,039 Btuh HVAC System CFM = 2,400 HVAC System CFM = 3,200 Fresh air makeup = 689 CFM Make Up Air CFM = 3,550

Positive Building Pressure More Mechanical Air Coming Air Than Air Being Exhausted = Positive Pressure

Building Pressure Less Mechanical Air Coming Air Than Air Being Exhausted = Negative Pressure

Pressurization Question (worksheet 4) A restaurant has an exhaust fan that is designed to pull 2,300 CFM of air of the kitchen. It has a dedicated outdoor makeup air system that brings in 2,300 CFM. If you wanted to make the kitchen positively pressurized what would need to happen?

Total Area Pressurization Question (worksheet 4) The kitchen exhaust hood could be slowed down so it pulled out less air. However, it may not meet the code airflow requirements. The dedicated outside air system could be adjusted so it will bring in more outside air if the unit sizing will allow for the increase and still properly heat and cool the entering air. Air could be brought in from the dining area if it is operating at a higher pressure than the kitchen. Again Codes must be followed. For example, in the location where Maria’s restaurant was located the air transferred would need to be filtered.

What Pressure Is Best A slightly positive building pressure is preferable to keep contaminants in the air from leaking in.

Odor From Kitchen In Dining Area (worksheet 4) Kitchen odors are coming into the dining area when the waiters open the doors to the kitchen. The owner states this never used to happen. What could be the cause for this change in pressure?

Odor From Kitchen In Dining Area (worksheet 4) The number one cause to check would be the dining area HVAC system outside air minimum position. If it was closed off or stuck closed, the dining area would lose its positive pressurization. The number two thing to check would be the makeup air fan or pathway for the kitchen hood. It could be as simple as dirty filters. (Continued Next Page)

Odor From Kitchen In Dining Area (worksheet 4) It could be something else, like a prevailing wind into the back kitchen loading area door that is being left open. It could be a combination of all of the above. When checking a system check all of the components!

Field Notes Generally, the engineering additional CFM designs to provide pressure differences will work. However, positive and negative air pressures between zones with designs based on extra CFM in those zones always needs to be checked in the field. The pressures are very small and can be influenced by wind outside of the building and the tightness of the buildings outside walls and the walls separating the Zones. The easiest and quickest check is with a chemical smoke stick that can verify the airflow direction at doors and between sections.