2017 CALACT Maintenance Forum IntelligAire III & ClimaAire 1D Presented by: James Cole Western Region Service Manager – Bus HVAC
IntelligAire III Monitoring Screen
CanDiag Diagnostic Kit 204-1927 Laptop PC requires Windows® XP, Windows® 7
USB/CAN ADAPTERS New Version Old Version
Installing CanDiag Must have administrative rights and internet access to properly install Uninstall previous versions of CanDiag before installing version 1.6.0
CanDiag Icons
Diagnostics
Updating CanDiag Issue with CanDiag update link
CanDiag Firmware Version
IntelligAIRE III Updating & Firmware Updating CanDiag & Firmware
IntelligAIRE III Updating CanDiag & Firmware
Updating CanDiag Issue with CanDiag update link Contact James Cole at the Thermo King booth, or e-mail james.cole@irco.com, for temporary link until issue is corrected in program
CanDiag Setup
IntelligAire III Login service irkolin
Custom Password 1) Left click on down arrow and hold 2) Drag cursor down to ‘change password’ 3) Release
Diagnostics
Module selection Main Module ID0 0 Main Module ID0 1 Main Module ID0 2
Module Screens Real Time Data Programmable Features & Test Modes Alarm Codes Energized Outputs
IntelligAIRE III Configuration Files telligAIRE III
IntelligAIRE III Configuration Set Up telligAIRE III
IntelligAIRE III Configuration Set Up telligAIRE III
Flash Load/Configuration Files IntelligAIRE III Can DIAG Flash Load/Configuration Files
IntelligAIRE III Configuration Files
DEMO
IntelligAIRE III IntelligAIRE III Sensor Calibration
Firmware Flash Load Cables
Bench Loading IntelligAire III Firmware
Bench Loading IntelligAire III 24v or 12v Power Supply
Warranty Procedure 41-9353 Main Module
EEPROM Backup
Service Bulletin 572-28 Firmware Revision 04.00.00
Firmware Cable Port Identification
Introduction to IntelligAIRE III Flash Loading/Com Port Set Up Introduction to IntelligAIRE III Steve Morris Thermo King, Bus Service Manager Minneapolis, MN Start (lower left on desktop) Devices & Printers
Thermo King, Bus Service Manager IntelligAIRE III Flash Loading/Com Port Set Up troduction to IntelligAIRE III Steve Morris Thermo King, Bus Service Manager Minneapolis, MN
Flashloading / Com Port Set Up IntelligAIRE III Flashloading / Com Port Set Up P3 LED P1 P5 P4 P2 P6
Flashloading / Com Port Set Up IntelligAIRE III Flashloading / Com Port Set Up P3 LED P1 P5 Cycle power to complete flashload P4 P2 P6
Shutdown Alarm Lockout SB645-1 3 alarm events in 100 hour increments 17 possible shutdown codes Separate counter for each code Code 49 “pending lock out fault” 2 alarm events
Shut Down Alarm Lockout
Shutdown Alarm Lockout
IntelligAIRE III DDM
IntelligAIRE III dEg System Set Up Mode Setup Mode is disabled if the lockout bit is set in the configuration file. To enter, press and hold the Up/down key for 3 seconds. Team work
IntelligAIRE III Service Test Mode Pt Pre Trip Down/select key 3 seconds Select key to scroll UP or Down to start test on/off to exit Pre-Trip test only available from DDM, not CanDIAG program Team work
IntelligAIRE III Service Test Mode Team work
IntelligAIRE III Pressure Readout Mode SP1 Team work
IntelligAIRE III Temperature Readout Mode rtS Rts – 1 second Actual temp. – 2 seconds Team work
IntelligAIRE III - - - Alarm Readout mode Active alarms only Yellow-Check Red-Shut down Active alarms only Active alarms only Team work
Keypad Set Up & Diagnostics
Data Monitoring Files
Data Monitoring Files
Data Monitoring Files
Data Monitoring Files Use MMO Spreadsheet
Data Monitoring Files Demo Accessing Files Reading Files Windows C drive Program files Thermo King CanDIAG Data Monitor MMO Highlight column A Data Text to column Delimited Next Check semi colon Finish
ClimaAire 1D
ClimaAire Controllers ClimaAire 1D ClimaAire II
ClimaAire 1D
ClimaAire Set Up Kit
Overview of Controller Functions „t1“ - Test mode 1 – basic test A/C unit function TEST MODE 1 allows operating the unit manually for charging or testing. „rt “ - Manual relay test „EL“ - evaporator low speed relay (EFRL) „En“ - evaporator medium speed relay (EFRM) „EH“ - evaporator high speed relay (EFRH) „CL“ - compressor clutch and condenser relay (CR) „bP“ - boost pump relay (BPR) „C0“ - modulating coolant valve (MCV)–low side output–for old ClimaAIRE I „C1“ - modulating coolant valve (MCV) – high side output „d0“ - damper output – low side output – for old ClimaAIRE I „d1“ - damper output – high side output „Pr “ - Set up of program number and firmware version reading „CA“ - Calibration of temperature sensors „SE“ - Set Up parameters „AL“ - Reading and clearing alarms „Hr“ - Reading hour meter
Alarm Indicators Red Alarm Symbol • Cycling of Clutch 05 Red alarm Yellow Alarm Symbol • Cycling of Clutch 05 Red alarm • Long delay of HPCO and LPCO 06 Red alarm • Inverter Alarms – detail are described in SR10E 31-37 Red alarm • RTS – Low value 07 Yellow alarm • RTS – High value 08 Yellow alarm • CTS – Low value 09 Yellow alarm • CTS – High value 10 Yellow alarm • ATS – Low value 11 Yellow alarm • ATS – High value 12 Yellow alarm
ClimaAire 1D Pocket Card
James Cole Western Region Service Manager – Bus HVAC James.cole@irco.com 602-245-0215