Step by Step application

Slides:



Advertisements
Similar presentations
MO-735 Overlock Dealer Training CLICK.
Advertisements

Equipment for Assembly Fluke Multimeter 115 True RMS Glue Ring Jig Flathead screwdriver 60 Watt desk lamp HIOS Cl 4000 Electric screw driver Anti-static.
1 © 2010 KCI Licensing, Inc. For KCI Internal Training Use Only. Do Not Copy. Do Not Distribute. DSL# (06/10) Prevena™ Q2 Marketing Update Amy Torrecillas.
Optimum Round Pool Instructions. Prepare the pool site Remove all the grass on a surface 2’ wider than the size of the pool Level the ground.
Slab constructed cup Flatten a lump of clay into a long shape as you will be rolling out a slab long enough to wrap around a tube form. Note: finished.
Facts about the Tetrahedral Kite 1.Four pyramid shapes are joined together to make the Tetrahedron Kite. 2.Each pyramid shape is built according to the.
Drawing & Painting Final Exam Book-Making Instructions.
ICRA Panel System Installation Instructions
Central Line Placement The Animal Emergency Clinic Puget Sound Veterinary Referral Center, PLLC.
Presented by: Sana’a AL-Sulami Teacher assistant Nursing department.
How to make a wearable pinhole camera Don Duggan-Haas, Museum of the Earth Materials:  Photocopy paper box  Tape:  Duct  Transparent  Electrical or.
How to Make a Hot Air Balloon
Fundamentals of Taping. Why do ATC’s tape? Protective tape is used to prevent injuries and to keep existing injuries from getting worse Must be applied.
Ocean Science Data Based Lesson A Guide to Construction of Materials for Ships, Ocean and Satellites (S.O.S.) Paper version This guide is intended to be.
Suture Materials ABSORBABLE: lose their tensile strength within 60 days. NON- ABSORBABLE:
How to construct a handbag
CONSTRUCTING A FIVE CABIN LATRINE
School Name Date Volunteer Name Electric Generator SEEDKIT Workshop.
A37 Wound Management Emergency Treatments and First Aid Kit
Gail Vanairsdale Global Clinical Education Manager Enlite Sensor Insertion.
Session V A, Slide #1 Contraceptive Implants Session V A: Two-Rod Implant Insertion.
© 2008 The McGraw-Hill Companies, Inc. All rights reserved. M I C R O S O F T ® Refining Original Illustrations Lesson 9.
Lifter Step-by-step assembly instructions (c) 2010 National Fluid Power Association.
ASSEMBLING THE PCB – V3.914 Hold the PCB as shown below.
7th Grade Cool Snow Flakes color - shape Objectives: Learn Focus on. Materials manilla sketch paper 9x12 cut down to 9x9 you will need about 4 per student.
Oneone IN-4 Objective: To construct a catapult or series of catapults in order to test an experimental variable. Core Question: How is the experimental.
Making Models. Purpose Demonstrate sea-floor spreading adding material to the ocean floor.
Introduction to Drafting and Design In order to begin our drawing we have to set the drawing limits or the paper size.
TAKE NOTE ON THE ORDER OF PROCEDURE FOR CONSTRUCTION OF THE LAMINATE COUNTERTOP. Countertop Procedures.
How to Change Raptor Knife Blades. Step 1: Use a Phillips screwdriver to remove the 5 screws. It is not necessary to remove the lanyard/webbing to change.
Pencil Case Production Yr 7 Textiles. Cutting and marking out your fabric pieces: Cut one piece of material 50 cm x 40cm.
1. 2 Routinely used by athletic trainers Used to minimize swelling, provide support to injured areas and prevent injury While techniques are not difficult.
Folding Fold a paper crane Prepare a square paper.
Monolith Collection and Preparation For soils without restrictive layers Conrad Neitsch USDA-NRCS MLRA Region 9 Staff Temple, TX.
Making A Paper Bag Cover Cut open a brown paper shopping bag, the kind you get at the grocery store. Start by cutting down one corner, from top to bottom,
Which shape column is the strongest?
RockOn! RockOn! Structure Build RockOn! 2009.
Non-elastic and Elastic Adhesive Taping Historically an important part of athletic training Becoming decreasingly important due to questions surfacing.
Sit at tables Take notes on how to construct a Tetrahedron Kite.
Artist Portrait and Artwork
Step-by-step assembly instructions
Taping Mr. B. Oliveira Sports Medicine.
Example Standard Work Sheets Paper Drinking Cup
Step-by-step assembly instructions
Hot-Air Balloons.
Step-by-step assembly instructions
Step-by-step assembly instructions
Step-by-step assembly instructions
Tools you will use for this job
Step-by-step assembly instructions
Luxe Plank Replacement
Introduction to SolidWorks
Scalpel Training Anatomy and Physiology Lab
Step-by-step assembly instructions
Subpectoral Biceps Tenodesis Using an Expanding PEEK Device
Step-by-Step Assembly Instructions – Cube Version
Contraceptive Implants Session V A: Two-Rod Implant Insertion
1/17/2019.
Taping Mr. B. Oliveira Sports Medicine.
Taping and Wrapping.
Rocket Stability Building a Test Rocket LabRat Scientific © 2018.
Step-by-step assembly instructions
Step-by-step assembly instructions
Which shape column is the strongest?
Contraceptive Implants Session V A: Two-Rod Implant Insertion
One Tote Over The Line Jackie’s Basic Tote Lesson
Stage 9: Making a food product
Presentation transcript:

Step by Step application The dressing is designed to be applied in stages Tacking the top and bottom edges of the dressing first will help reduce wrinkling. If skin has wrinkles or folds, smooth out the skin as the dressing is being applied. Then remove each of the two remaining bottom adhesive covers, pressing on the skin as the cover is removed. Keeping a small amount of tension on the drape will also help prevent it from wrinkling. Smooth out the dressing perimeter as you apply it. Press firmly around the dressing to ensure a good seal Once the dressing is appropriately adhered, remove the top stabilization layers Hold the drape down on the skin as you remove the paper stabilization layers on the top of the dressing. Insert the canister into the Prevena™ 125 Therapy System, and slide inward until canister clicks. Canister is fully inserted when the side tabs are flush with the body of the therapy unit. Initiate therapy by pressing and holding the ON/OFF button for 2 seconds; an audible beep will confirm that therapy is on. A green LED on the front of the unit indicates that therapy is on. The dressing is intended to be applied over the suture and surrounding intact skin. The VisiCheck™ Feature should be utilized to check the seal integrity. For internal use only do not distribute DSL#13-0746.EMEA.PREP Nov. 7, 2013

Intersecting Incisions – application of Prevena™ Customizable™ Kit Open the sterile dressing package, remove and unfold foam dressing using aseptic technique. Use enclosed ruler to measure incision before cutting. Cut foam dressing to the length and shape necessary to cover the incision. CAUTION: Do not cut the foam over the wound, as fragments may fall into the wound. Away from wound site, rub foam edges to remove any fragments or loose particles that may fall into or be left in the wound upon dressing removal Gaps at foam junctions may potentially cause erythema due to pinching of the skin when negative pressure is applied. DO NOT overlap foam dressing pieces on top of each other. Use sealing strips at the ends of foam dressing to create a continuous seal. Sealing strip should have equal overlap on both foam dressing pieces. Liner 1 must be removed from the dressing before applying sealing strips. 2. 3. 4. For internal use only do not distribute DSL#13-0746.EMEA.PREP Nov. 7, 2013

Intersecting Incisions 5. With sealing strips applied, position the foam dressing until the adhesive seal and white fabric are facing down. It is acceptable if sealing strips cover the incision line. Place the foam dressing over the incision/surgical closure.Ensure the adhesive seal and white fabric are facing down. After foam dressing placement is completed, ensure all liners are removed before continuing with the drape application. 6. 7. For internal use only do not distribute DSL#13-0746.EMEA.PREP Nov. 7, 2013

Drape Application 1. Trim KCI Drape as necessary. Ensure a minimum overlap of 1.2 in (3 cm) when using multiple pieces of KCI Drape. There is no KCI Drape under the blue handling bars Carefully remove the middle section of layer 1 from KCI Drape to expose adhesive. Leave the two end sections of layer 1 intact to maintain drape stability during application. The KCI Drape should be held by the blue handling bars. With adhesive side down, apply KCI Drape over foam and onto intact skin. Ensure KCI Drape covers a minimum of 1.2 in (3 cm) of intact periwound tissue. Lift the drape at both ends and remove the two remaining end sections of layer 1. Smooth out any wrinkles in the KCI Drape. 2. 3. For internal use only do not distribute DSL#13-0746.EMEA.PREP Nov. 7, 2013

Drape Application 5. Carefully remove striped layer 2 from KCI Drape Remove the two blue handling bars. Add additional drape as needed to cover foam dressings in various configurations, as shown. Smooth KCI Drape to remove creases and seal joints ensuring an occlusive seal. All liners must be removed before additional drape is used. Press drape down around the length of the adhesive seal to ensure adhesion to the skin. Press down to seal all drapes. Minimize any creases/wrinkles in drape. Excess KCI Drape can be used to seal leaks. 6. 7. For internal use only do not distribute DSL#13-0746.EMEA.PREP Nov. 7, 2013

Interface Pad Application 1. Use the oval cutout on the enclosed ruler as a template for hole size when cutting a hole in the drape for the interface pad. The removable label may be used as needed to record date of dressing application or removal. Near Center of foam dressing, carefully cut a hole in the KCI Drape using a scalpel or scissors. It is not necessary to cut into the foam but if a small amount of foam is removed it will not inhibit performance. Remove the cut section of drape. Remove both backing layers 1 and 2 from pad to expose adhesive. 2. 4. For internal use only do not distribute DSL#13-0746.EMEA.PREP Nov. 7, 2013

Interface Pad Application Place the pad opening in the central disc directly over hole in KCI Drape. Apply gentle pressure on the central disc and outer skirt to ensure complete adhesion of the pad. Pull back on blue tab to remove pad stabilization layer. Interface pad application is complete. Insert Canister into Prevena™ 125 Therapy Unit and connect the dressing to the Prevena™ Therapy Unit. Initiate Prevena™ Therapy by pressing and holding the power button for a minimum of 2 seconds. 5. 6. 7. 8. For internal use only do not distribute DSL#13-0746.EMEA.PREP Nov. 7, 2013

Dressing Removal Upon completion of therapy, dressing should be removed in line with the incision. For internal use only do not distribute DSL#13-0746.EMEA.PREP Nov. 7, 2013