Presentation on Best Practice for Electrical Equipment Installation and Safety of Product(Earthing & Protection) Farmer is Our Nation Pride Fertilzer Process.

Slides:



Advertisements
Similar presentations
Electricity Chapter 13.
Advertisements

…your final connection. Mine Cable Services Corporation. Cable Repairs: Vulcanized Splices.
PLAZMA HEATING PRODUCT INDIA G-52 LAWRENCE ROAD,INDUSTRIAL AREA, NEW DELHI
Electrical Installation
DESIGN OVERHEAD TRANSMISSION LINES Prepared by:- Er. Varinder Kaur
EE4503 Electrical Systems Design
1 AHT's Technology Amorphous material - a solid with the internal structure of a liquid. Created by accelerated cooling process (1,500,0000°C/sec) of the.
Guide to Network Cabling Fundamentals
(MT 207) B.Sc (ENGINEERING) LEVEL 2 (Semester 2)
CHAPTER 9 Electrical Design of Overhead Lines
Chapter 3Transmission Lines Why use high-voltage transmission lines? The best answer to that question is that high-voltage transmission lines transport.
Electricity and magnetism
Electrical Earthing D.K.Pathirana. Applications of earthing Protect human against lightning and earth fault condition Protect the premises against lightning.
Electricity & Magnetism
Warm Up: Battery and Bulb Can you make a bulb light using only a bulb, a D-cell battery and one piece of wire? Draw a picture of all the ways you try to.
Lightning Protection Chapter 6 PowerPoint slides by
BASICS OF ELECTRICITY Vocabulary Understanding of Layer 1 & Layer 2 Networking Professionals need a basic understanding.
Electricity & Magnetism Static, Currents, & Electro Magnets Motors & Generators.
Integrated Grounding, Equipotential Bonding and Lightning Protection in Smart Grids and Smart Buildings – A Multi-Faced Approach Ladies and gentlemen,
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
Chapter 16.  Smallest particles of matter are called atoms  Electrons  Protons  Neutrons.
DIELECTRIC HEATING KUMAR CHATURVEDULA. DIELECTRIC HEATING KUMAR CHATURVEDULA Dielectric heating, also known as electronic heating, RF heating, high-frequency.
Utility Engineers, PC.  Generation  Transmission  Distribution.
Electrical Safety Authority
Current Electricity is the rate at which charges pass a given point. The higher the current is the greater the number of charges pass the point each second.
DO NOW:  Using notepaper; write down the following: 1.The three parts to an atom? 2.The charge of each atomic part? 3.Where is each part located?
Switches and Over Current Protective Devices Class Instructor ALPHER E. DE VERA, uap.
LIGHTENING PROTECTION USING LFA-M
Flammable Liquids Directorate of Training and Education
ELECTRICAL INSTRUMENTS ( service and utilization )
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Tinned copper wires over Bare copper wires. Bare copper wires are the most popular sets of copper used in electrical and mechanical circuits. They are.
WIRES, CONDUITS AND RACEWAYS Class Instructor : VINCENT J. DAYAG JR,MSArch.UAP.PIEP. Architect / Environmental Planner.
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
Solar PV Power Project and Support from JMV LPS LTD.
Presentation on Best Practice for Electrical Equipment Installation and Safety of Product(Earthing & Protection) Our Nation Pride INDIAN Railway/Smart.
India First High speed train JMV LPS LTD Earthing and ProtectionYear 2017.
1 Fundamentals of Electricity, Magnetism, and Electronics.
Electric Charge and Static Electricity
Unit 3 Lesson 3 Electric Circuits
Electricity & Magnetism
Sub Station.
Shop Orientation and Procedures
Grounding And Safety Techniques Ms. Tahoora Qureshi, Asst. Professor
Design of Overhead Transmission line
Ms. Tahoora Qureshi, Asst. Professor
Permanent Lifting Magnets
ELECTRIC SHOCK AND EARTHING
EARTHING.
Electric Charge.
Chemical Transfer.
Installation And Estimation of Service Connection
Engineering Project Cable Management.
Components of Substation
Unit 3 Lesson 3 Electric Circuits
ELECTRICAL POWER-II Electrical engineering sixth semester
Electricity & Magnetism
External Lightning Protection System
Steel.
Protection against over voltages
POWER SYSTEM-II (III-1)
ELECTRICAL INSTALLATION
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
CST 450 Flare Stack Cable High Temperature, Fire resistant, High Voltage Single Conductor.
Under Ground Cables By Dr. P. Bala Chennaiah, Associate Professor,
Presentation transcript:

Presentation on Best Practice for Electrical Equipment Installation and Safety of Product(Earthing & Protection) Farmer is Our Nation Pride Fertilzer Process &Power Plant We Salute Indian Farmers

SMART Process Plant Project

SMART PROCESS PLANT AUTOMATION CONSULTANT TEAM India IFFCO Ltd (Phulpur Unit) 50Years Success Celebration Pride for india WELCOME FOR THE PRESENTATION ON Best Practice ELECTRICAL Equipment Installation And SAFETY PRODUCTS (Electrical Controls Communication Networking Monitoring)

Process Plant is Combination of Mechanical, Electrical and Control Automation Project which is More Dependable with Motors and Actuator Functions. Large Field Maintaining Incoming Material Storage, Handling and Pumping up to Process Plant Later Storage and Transportation for Final Bio Products. Handling of Water and Air for Process Activity some with Cooling and Heating Process. Packaging of Finish Products.

Process Plant Air Water Fire Pressure

Source of Power Through Grid Wind Machine Solar PV/Solar Thermal Captive Power (Genset) Battery Back-up UPS/Invertor Waste Heat Recovery Power Plant

Category Hazard Zone Flammable Highly Flammable Highly Corrosive

Building and Infra Facilities Local Power Generation and Connect to Grid/Off Grid Fibre Optic Network Wireless/Satalite Communication Tower Substation as per Require Capacity Smart Net Metering and Monitoring (SCADA) Street Light use LED /Stand Alone (Solar) Weighing Plateform for Transports Water Storage and Distribution/Waste Water Treatment Bulk Storage Terminal and Distribution

G M GenerationTransmissionDistributionLoad Generation Transmission Distribution Consumption Electric Power Systems for Indian Fertilizer &Process Plant

My Gudget My Confidence My Safety

Smart Buildings is not enough we require Protection from Fire and apply Safety

External/Internal Surge Source

An Arcing Fault is the flow of current through the air between phase conductors or phase conductors and neutral or ground. Concentrated radiant energy is released at the point of arcing an a small amount of time resulting in Extremely High Temperature.

Fire Accident Reason Lose Contact Earthing Disorder and Lightning

Sikhana to Padega Hi Follow NBC2016

Surge in Systems and Result

Surge in DC Application

Maintenance Free - Equipment Earthing

33KV Electrical Sub Station

Grid/Earth Mat Design

JMV LPS Products

Copper Cladded Conductor For Electrical Installation The Copper Clad Steel Grounding Conductor is made up of steel with the coating of 99.99% pure copper. These conductors/ wires or strands are equipped with the strength of steel with the conductivity and copper with the better corrosion resistance property. The concentric copper cladding is metallurgic ally bonded to a steel core through a continuous, solid cladding process using pressure rolling for primary bonding. The copper cladding thickness remains constant surrounding steel. We use different steel grades for the steel core result in Dead Soft Annealed, High strength and Extra High Strength Characteristics. The Copper Clad Steel Wire yields a composite conductivity of 21%, 30% and 40% IACS, and available in Annealed and Hard drawn. We are delivering products with varied conductivity and tensile strength as per the customer need. Further, the wire can be processed to be silver plated or tinned copper clad steel wire.

Most Efficient Joint Process/Fail Proof It is efficient and superior to all existing surface –to-surface mechanical retention connectors.

What is Exothermic Welding System Copper to Bi-Metal and Alumenium Types of Exothermic Joints: Possible to join any bi metal except aluminum Exothermic welding is a process of making maintain free highly molecular bonding process is superior in performance connection to any known mechanical or compression-type surface-to-surface contact connector. Exothermic weld connections provide current carrying (fusing) capacity equal to that of the conductor and will not deteriorate with age.  It offers Electrical connections between two or more copper to copper and copper to steel conductors.  Highly portable method as it does not require any external power source or heat source, so it can be done almost anywhere.  It provides strong permanent molecular bond among metallic conductors that cannot loosen and further will not deteriorate with age.  Connection does not corrode with time and it offers permanent conductivity.

Copper Clad Steel Solid ROD and Conductor

Losses Due To Lightning

LIGHTNING FORMATION

Facts about Lightning A strike can average 100 million volts of electricity Current of up to 200,000 amperes Can generate 54,000 o F 10/350MicroSec/50KA Fault Current/Discharge in Nano Sec Protection Earthing Design100KA Fault Current/Joints Exothermic /Flexible Down Conductor with Shortest Route & Less Corner

Lightning Protection Standard use in India (IS2309 Now IEC )NBC2016 Working Principle Angullar No Compromise with Design Max Protection 30Mtrs from One No Product warrenty from Manufacturer High Maintenance Require Earthing below Ohm

Lightning Risk assessment Study is actually the measure of risk of a lightning strike and probability of damages. As Per IEC All these calculations are based on: Lightning strike density inthat particular area(provided byOMV i.e.Ng = 8), Danger for people, Occupation coefficient of structure, Relative location of site, Fire Risk, Associated services, Electrical Lines, Lightning Protection Level, Surge Arrestor and Dimensions of installation.

Lightning Safety Calculation

Lightning Risk Calcuator as per IEC6305

PASSIVE PROTECTION SYSTEM

The Simple Rod air terminal is composed from a metallic rod with 2 to 8 m height dominating the structure to protect, and linked to 2 down conductors minimum, and 2 earthing systems. The protection radius ensured by this air terminal which is limited to 30 m more or less (Protection level IV, height = 60 m), especially dedicated to the protection of small structures or areas like towers, chimneys, tanks, water tower, antenna masts… The EN standard describes the installation procedure for these air terminals. 13 Simple Rods, 13 down conductors, and 13 earthing systems are necessary to ensure the protection below :

The meshed cage protection is composed from a meshing in roof surface and in the front face around the building. Surrounding the roof surface, and on high points, capture points are positioned. A conductors’ network is placed at the outer perimeter of the roof. This network is completed by transverse conductors. The size of the meshing is 5 to meters, and depends on the efficiency needed for the protection. On the front face of the building, the down conductors are linked at the top to the meshing of the roof. And, down, to specific earthing systems. The distance between two conductors is 10 to 25 meters, and depend on the efficiency needed for the protection. The EN describes the installation procedure for this method. Generally, this method is heavy and expensive, due to the complexity of the structures to protect. 26 capture points, 26 down conductors and a grounded loop earthing system are necessaries to ensure the protection of the structure here below :

The catenary wires protection is a method closed to the meshed cage principle, because it is constituted with meshing of the conductors far from the structure to protect, to avoid any contact with lightning current. Catenary wires are located over the structure to protect, connected to down conductors and specific earthing systems. The width of the meshing and distance between the down conductors must respect the same rules as for the meshed cage. The EN describes the installation procedure for this method. Generally, this method is heavy and expensive, due to the complexity of the structures to protect.erally, this method is heavy and expensive, due to the complexity of the structures to protect.

The ESE air terminal is a terminal which enables to generate artificially an upward leader earlier than a simple rod, with an ionization system, in order to establish a special impact on its point. The capture of the lightning strike being faster than a simple rod, this technology enables to benefit from larger protection areas, ensuring protection for large dimensions structures. The generated protection radius depends on the early streamer emission value of the air terminal (Δt in µs), its height, and the efficiency of the protection. The protection radius ensured by this type of air terminal is 120 m (Protection level IV, height = 60 m, early streamer emission time 60µs) The NFC standard describes the installation procedure for this type of air terminal. The installation of this type of air terminal is easy and cheaper than other technologies. It can protect whole buildings with one E.S.E. air terminal. It enables the protection of a structure and its environment, the protection of opened areas and well integrate in the architecture of a structure without aesthetic alteration. 1 ESE, 2 down conductors and 2 earthing systems are necessary to ensure the protection below :earthing systems are necessary to ensure the protection below :

ESE Installation Guidence ESE AT with radius protection form 32 mtr to 107 mtr. DMC Insulator. GI/FRP Mast. Down Conductor Copper / Copper Cadmium Cable 70 sq. mm Copper Bonded Ground Earthing

Step – 1 Step – 2 Step – 3 Joint all phase wire/ cable with the help of crimping tools and lugs Fixed the separation sheet between all wires/ cables Close the filled Silicon enclosure from top and bottom, complete installation is done. Thimble Separation Sheet Gel / Silicon

Features : Provides cable with cable connections and jointing wires in switchboard / electric boxes Being a jelly it can be easily fit into molds of any shape and size. Helps in safeguarding electrical connections and also protects electrical connection joints from catching fire, sparking and leakage current. Eradicates all the possibilities of fire, electric shocks and sparks, etc. causes due to improper electrical connection joints and safeguards structure, equipment and person. Offers safety to your electrical joints from ageing, corrosion, moisture and also observes leakage current. Advantages : Nontoxic Insulating Highly reliable operation Maintenance Free Repairable Cost Effective High repeat value Elasticity Shape retention

We are offering Surge Protection Devices as IS/IEC

We are offering 24X7 Clean Power for Better Performance of your system

JMV’s Clients

Contact Professionals for Advise

We Protect You Use Electrical Safety Earthing & Protection

Contact our Team JMV INDIA Leader and Insperation behind Mr.Neeraj Saini Mr.Mahesh Chandra Manav Brand JMV HOD Moblie Telecom