Crude Oil Refinery Heat Exchanger Network

Slides:



Advertisements
Similar presentations
PROCESS SYSTEMS ENGINEERING GROUP
Advertisements

Heat Exchanger Network Retrofit
Analysis of heat exchangers: Use of the log mean temperature Difference LMTD Method: Q= (m cp ∆T) h = (m cp ∆T) c Q= U A F∆T lm A=N װ DL ∆ T lm = ∆T l.
1 Name, title of the presentation Master project: Control structure design for a sequence of distillation columns Tor Anders Marvik Supervisor: Sigurd.
From Black Oil to Rubber Tires  Crude Oil is processed at the refinery to create the raw material synthetic rubber to make tires.  The refining process.
From Black Oil to Colorful Paint  Crude Oil is processed at the refinery to create the raw material polystyrene plastic to make paint.  The refining.
Delayed Coker Unit Savings Best Practice. Delayed Coker Heater Tube Skin Temperatures. Delayed Cooker Units have heaters with tube skin thermocouples.
PROCESS SYSTEMS ENGINEERING GROUP Førsteamanuensis Tore Haug-Warberg Professor Heinz Preisig Professor Sigurd Skogestad Førsteamanuensis Nadi Skjøndal-Bar.
What are types of nonrenewable energies?. Nonrenewable Energy Main Types of Nonrenewable Energy 1. Coal 2. Crude Oil 3. Natural Gas 4. Nuclear Energy.
Specific Heat. Names Specific Heat Capacity Specific Heat Heat Capacity.
1 Operation of heat pump cycles Jørgen Bauck Jensen & Sigurd Skogestad Department of Chemical Engineering Norwegian University of Science and Technology.
Control of floor heating process Siri Hofstad Trapnes Supervisors: Sigurd Skogestad and Chriss Grimholt Direct heating in the floor and room Keep the temperature.
Optimal temperature control of rooms Siri Hofstad Trapnes Superviors: Sigurd Skogestad and Chriss Grimholt.
Multi stream, multi phase heat exchangers Modeling, optimization and heat integration Candidate: Axel Holene ; Supervisors: Sigurd Skogestad, Johannes.
1 Active constraint regions for optimal operation of a simple LNG process Magnus G. Jacobsen and Sigurd Skogestad Department of Chemical Engineering NTNU.
Heat transfer in turbulent flow CL Aim To determine the overall heat transfer coefficient & the individual film transfer coefficient and verify.
Models for online control of batch polymerization processes. Student:Fredrik Gjertsen Supervisor, NTNU:Prof. Sigurd Skogestad Supervisor,
Outline Skogestad procedure for control structure design I Top Down
Network Modeling: Oil Blending Team 1 (Shahram, Yusuf, David, Rush)
Models for on-line control of batch polymerization processes Student:Fredrik Gjertsen Supervisor, NTNU:Prof. Sigurd Skogestad Supervisor,
최민 수 Choi Min Su 최민수.
Seamless Solutions from Study to Revamp tailor made solutions at least cost with minimum outlay We deliver Moscow / St Petersburg, March 2011.
So taking a bite….this happens…..which ingredient has caused the problem and why?
Supervisor by :Prof. Dr. Malek Al-Ahmad Name : Ali Hassan Al-Godrani
1 Using Self-Optimizing Control on the Statoil Mongstad HEN Daniel Greiner Edvardsen May 27, 2010 NTNU Confidential.
1 Optimization of LNG plants: Challenges and strategies Magnus G. Jacobsen Sigurd Skogestad ESCAPE-21, May 31, 2011 Porto Carras, Chalkidiki, Greece.
Johannes Jäschke PhD title: Invariants for optimal operation of process systems, 2011.
1 Optimal operation of energy storage in buildings: The use of hot water system Emma Johansson Supervisors: Sigurd Skogestad and Vinicius de Oliveira.
1 Modelling of Biodiesel Production Marianne Øien Supervisors: Sigurd Skogestad and Chriss Grimholt.
Economic Plantwide Control using
Optimum Performance of Radiator Space Heating Systems Connected to District Heating Networks via Heat Exchangers Patrick Ljunggren, Janusz Wollerstrand.
Negative Feedback Control Heat Exchanger Transfer Function.
Specific Heat Capacity. Specific Heat Capacity (kJ/kg/°C) The specific heat is the amount of heat (measured in kJ) per unit mass (measured in Kg) required.
1 Visit at Perstorp Daniel Greiner Edvardsen (Master student) Johannes Jäschke (PhD) April 14th, 2010.
Boiler Energy Saver Advanced Boiler Controls. Most boiler controls at present consist of a switch!
Evaluate the expression for the given value 1.9 b+7 when b=14 A. 189 B. 63 C. 18 D. 133.
Process control group of Sigurd Skogestad, Departmenmt of Chemical Engineering, NTNU, Trondheim,
WS: Calorimetry Problems
Ground-Water Cooling System On The London Underground.
ECONOMIC PLANTWIDE CONTROL USING COMMERCIAL PROCESS SIMULATION SOFTWARE PROJECT STATUS ADRIANA REYES LÚA SUPERVISOR: SIGURD SKOGESTAD CO-SUPERVISOR: VLADIMIROS.
LECTURE DAY 2 Timo Laukkanen. What was important in Lecture 1 Process Integration/Heat Exchanger Network Synthesis (HENS) is an important step in process.
W. Michael Griffin Engineering and Public Policy CEDM Annual Meeting
Process systems group 2017 Professors:
Refined Products from one Barrel of Crude Oil
by Lars Erik Øi and Vladyslav Shchuchenko
OIL REFINERY 3D Presentation.
HEAT EXCHANGER DESIGNPROJECT ME 414 Thermal Fluid System Design
Date of download: 10/27/2017 Copyright © ASME. All rights reserved.
Oil Refining.
Stian Aaltvedt Supervisors: Sigurd Skogestad Johannes Jäschke
Number Talk
Reading Materials: Chapter 9
Convection.
PROCESS SYSTEMS ENGINEERING GROUP
Optimization of Oil Production
Decimal Place Value.
KM451 MTBE SYNTHESIS FROM BIOMASS
Derivatives Practice.
Modelling of the production of biodiesel by reactive distillation
Components of the Upstream
Simplified First Principle Model for Severe
Operation and Control of Divided Wall (Petlyuk) Column
Objectives Finalize AHU processes
Fuel Combustion Fossil Fuel Hydrocarbon Energy Transformation
CH EN 5253 – Process Design II
12. Heat Exchangers Chemical engineering 170.
Performance and Robustness of the Smith Predictor Controller
PID control of unstable chemical reactor
How do we Adapt?.
Presentation transcript:

Crude Oil Refinery Heat Exchanger Network Name: Trine Witzøe Supervisors: Johannes Jäschke & Sigurd Skogestad

Results so far

Jäschke Temperature CaseI: Heat Exchanger E12 w/fouling resistance, CrudeSplit50/50 - Optimazation in Hysys gave - Tfinal=75,55ºC & Thotfinal=55,46ºC - Tjh1=-41,2ºC & Tjh2=-41,9ºC - Using Adjust block on HotSplit with Tjhot equal gave - Tfinal=75,56ºC & Thotfinal=55,46ºC

Planned work Optimize Heat Exchanger Network using Jäschke Temperature Compare results and evaluate if there is cost savings in optimizing the split Present results to Tüpras, Turkey Look at some cases for Johannes Jäschke