GreenCloud: A Packet-level Simulator of Energy-aware Cloud Computing Data Centers Dzmitry Kliazovich, Pascal Bouvry, Yury Audzevich, and Samee Ullah Khan.

Slides:



Advertisements
Similar presentations
ElasticTree: Saving Energy in Data Center Networks Brandon Heller, Srini Seetharaman, Priya Mahadevan, Yiannis Yiakoumis, Puneed Sharma, Sujata Banerjee,
Advertisements

Green Cloud Computing Hadi Salimi Distributed Systems Lab, School of Computer Engineering, Iran University of Science and Technology,
The major IT companies, such as Microsoft, Google, Amazon, and IBM, pioneered the field of cloud computing and keep increasing their offerings in data.
“ElasticTree: Saving energy in data center networks“ by Brandon Heller, Seetharaman, Mahadevan, Yiakoumis, Sharma, Banerjee, McKeown presented by Nicoara.
Semester 4 - Chapter 3 – WAN Design Routers within WANs are connection points of a network. Routers determine the most appropriate route or path through.
Present By : Bahar Fatholapour M.Sc. Student in Information Technology Mazandaran University of Science and Technology Supervisor:
A Scalable, Commodity Data Center Network Architecture.
Energy Aware Network Operations Authors: Priya Mahadevan, Puneet Sharma, Sujata Banerjee, Parthasarathy Ranganathan HP Labs IEEE Global Internet Symposium.
Green IT and Data Centers Darshan R. Kapadia Gregor von Laszewski 1.
QoS-Driven Wireless Broadband Home Networking Based on Multihop Wireless Mesh Networks Authors : B. Park, W. Lee, S. Ahn, and Sungjoon Ahn Published :
E-STAB: Energy-Efficient Scheduling for Cloud Computing Applications with Traffic Load Balancing Dzmitry KliazovichUniversity of Luxembourg, Luxembourg.
Low-Power Wireless Sensor Networks
November , 2009SERVICE COMPUTATION 2009 Analysis of Energy Efficiency in Clouds H. AbdelSalamK. Maly R. MukkamalaM. Zubair Department.
DENS: Data Center Energy-Efficient Network-Aware Scheduling
1 Nikolajs Bogdanovs Riga Technical University, Lomonosova iela 1, LV-1019, Riga, Latvia, phone: , Two Layer Model.
1 Distributed Energy-Efficient Scheduling for Data-Intensive Applications with Deadline Constraints on Data Grids Cong Liu and Xiao Qin Auburn University.
A.SATHEESH Department of Software Engineering Periyar Maniammai University Tamil Nadu.
Joint Power Optimization Through VM Placement and Flow Scheduling in Data Centers DAWEI LI, JIE WU (TEMPLE UNIVERISTY) ZHIYONG LIU, AND FA ZHANG (CHINESE.
Copyright © 2011, Performance Evaluation of a Green Scheduling Algorithm for Energy Savings in Cloud Computing Truong Vinh Truong Duy; Sato,
Green Computing Metrics: Power, Temperature, CO2, … Computing system: Many-cores, Clusters, Grids and Clouds Algorithm and model: task scheduling, CFD.
Dzmitry Kliazovich University of Luxembourg
June 30 - July 2, 2009AIMS 2009 Towards Energy Efficient Change Management in A Cloud Computing Environment: A Pro-Active Approach H. AbdelSalamK. Maly.
Dzmitry Kliazovich University of Luxembourg, Luxembourg
Data Center Energy-Efficient Network-Aware Scheduling
GreenCloud: A Packet-level Simulator of Energy-aware Cloud Computing Data Centers Dzmitry Kliazovich ERCIM Fellow University of Luxembourg Apr 16, 2010.
Accounting for Load Variation in Energy-Efficient Data Centers
Ensieea Rizwani An energy-efficient management mechanism for large-scale server clusters By: Zhenghua Xue, Dong, Ma, Fan, Mei 1.
Next Generation HPC architectures based on End-to-End 40GbE infrastructures Fabio Bellini Networking Specialist | Dell.
Analysis and Forming of Energy Efficiency and Green IT Metrics Framework for Sonera Helsinki Data Center HDC Matti Pärssinen Thesis supervisor: Prof. Jukka.
1 Implementing a Virtualized Dynamic Data Center Solution Jim Sweeney, Principal Solutions Architect, GTSI.
-1/16- Maximum Battery Life Routing to Support Ubiquitous Mobile Computing in Wireless Ad Hoc Networks C.-K. Toh, Georgia Institute of Technology IEEE.
SizeCap: Efficiently Handling Power Surges for Fuel Cell Powered Data Centers Yang Li, Di Wang, Saugata Ghose, Jie Liu, Sriram Govindan, Sean James, Eric.
A Hierarchical Edge Cloud Architecture for Mobile Computing IEEE INFOCOM 2016 Liang Tong, Yong Li and Wei Gao University of Tennessee – Knoxville 1.
Ethernet Packet Filtering – Part 2 Øyvind Holmeide 10/28/2014 by.
Reporter: Hung-Wei Liu Advisor: Tsung-Hung Lin 1.
DENS: Data Center Energy-Efficient Network-Aware Scheduling
Performance and Energy Efficiency Metrics for Communication Systems of Cloud Computing Data Centers Hrushikesh Mahapatro IT
Energy Aware Network Operations
High Speed Interconnect Project May08-06
2010 IEEE Global Telecommunications Conference (GLOBECOM 2010)
CIS 700-5: The Design and Implementation of Cloud Networks
Confluent vs. Splittable Flows
Introduction to Load Balancing:
A Survey of Data Center Network Architectures By Obasuyi Edokpolor
IOT Critical Impact on DC Design
Green cloud computing 2 Cs 595 Lecture 15.
The Underlying Technologies
Semester 4 - Chapter 3 – WAN Design
CLUSTER COMPUTING Presented By, Navaneeth.C.Mouly 1AY05IS037
Grid Computing.
Chapter 4: Network Layer
On-Time Network On-chip
Management of Virtual Execution Environments 3 June 2008
Chapter 16: Distributed System Structures
Direct Attached Storage and Introduction to SCSI
Dedicated Hosting Servers In The US With Faster Bandwidth Connectivity Fast bandwidth connectivity for dedicated hosting servers is vital for any enterprise.
Cloud Computing Dr. Sharad Saxena.
Cloud Computing and Cloud Networking
Zhen Xiao, Qi Chen, and Haipeng Luo May 2013
ElasticTree: Saving Energy in Data Center Networks
NTHU CS5421 Cloud Computing
Web switch support for differentiated services
Internet and Web Simple client-server model
Cloud-Enabling Technology
CSE 550 Computer Network Design
Chapter-5 Traffic Engineering.
Host and Small Network Relaying Howard C. Berkowitz
Chapter 4: Network Layer
2019/9/14 The Deep Learning Vision for Heterogeneous Network Traffic Control Proposal, Challenges, and Future Perspective Author: Nei Kato, Zubair Md.
Data Center Traffic Engineering
Presentation transcript:

GreenCloud: A Packet-level Simulator of Energy-aware Cloud Computing Data Centers Dzmitry Kliazovich, Pascal Bouvry, Yury Audzevich, and Samee Ullah Khan 1 Introduction 2 GreenCloud Simulator 3 Simulator Components The major IT companies, such as Microsoft, Google, Amazon, and IBM, pioneered the field of cloud computing and keep increasing their offerings in data distribution and computational hosting. Gartner group estimates energy consumptions to account for up to 10% of the current data center operational expenses (OPEX), and this estimate may rise to 50% in the next few years. Along with the computing-based energy high power consumption generates heat and requires an accompanying cooling system that costs in a range of $2 to $5 million per year. There are a growing number of cases when a data center facility cannot be further extended due to the limited available power capacity offered to the facility. GreenCloud is a simulation environment for advanced energy-aware studies of cloud computing data centers, developed as an extension of a packet-level network simulator Ns2. It offers a detailed fine-grained modeling of the energy consumed by the elements of the data center, such as servers, switches, and links. Servers   Simulator Architecture Switches and Links Interconnection fabric that delivers workload to any of the computing servers for execution in as timely manner is performed using switches and links. Switches’ energy model: Distribution of Data Center Energy Consumption Chassis ~ 36% Linecards ~ 53% Port transceivers ~ 11% Workloads From the energy efficiency perspective, a cloud computing data center can be defined as a pool of computing and communication resources organized in the way to transform the received power into computing or data transfer work to satisfy user demands. The execution of each workload object requires a successful completion of its two main components computational and communicational, and can be computationally Intensive, data-Intensive, or of the balanced nature.

GreenCloud: A Packet-level Simulator of Energy-aware Cloud Computing Data Centers 4 Data Center Architectures 5 Simulation Setup 6 Simulation Results The data center composed of 1536 computing nodes employed energy-aware “green” scheduling policy for the incoming workloads arrived in exponentially distributed time intervals. The “green” policy aims at grouping the workloads on a minimum possible set of computing servers allowing idle servers to be put into sleep. The dynamic shutdown shows itself equally effective for both servers and switches, while DVFS scheme addresses only 43% of the servers’ and 3% of switches’ consumptions. Two-tier architecture The computing servers are physically arranged into racks interconnected by layer-3 switches providing full mesh connectivity. Characteristics: Up to 5500 nodes Access & core layers 1/10 Gb/s links Full mesh ICMP load balancing Energy consumption in data center Setup parameters Parameter Data center architectures Two-tier Three-Tier Three-tier high-speed Topologies Core nodes (C1) Aggregation nodes (C2) Access switches (C3) Servers (S) Link (C1-C2) Link (C2-C3) Link (C3-S) 16 - 512 1536 10 GE 1 GE 8 2 4 100 GE Link propagation delay 10 ns Data center Data center average load Task generation time Task size Average task size Simulation time 30% Exponentially distributed 4500 bytes (3 Ethernet packets) minutes Three-tier architecture Being the most common nowadays, three-tier architecture interconnects computing servers with access, aggregation, and core layers increasing the number of supported nodes while keeping inexpensive layer-2 switches in the access. Characteristics: Over 10,000 servers ECMP routing 1/10 Gb/s links Workload distribution Parameter Power consumption (kW·h)   No energy-saving DVFS DNS DVFS+DNS Data center Servers Switches 503.4 351 152.4 486.1 (96%) 340.5 (97%) 145.6 (95%) 186.7 (37%) 138.4 (39%) 48.3 (32%) 179.4 (35%) 132.4 (37%) 47 (31%) Energy cost/year $441k $435k $163.5k $157k Servers at the peak load Three-tier high-speed architecture Under-loaded servers, DVFS can be applied With the availability of 100 GE links (IEEE 802.3ba) reduces the number of the core switches, reduces cablings, and considerably increases the maximum size of the data center due to physical limitations. 7 Acknowledgements Idle servers, DNS can be applied The authors would like to acknowledge the funding from Luxembourg FNR in the framework of GreenIT project (C09/IS/05) and a research fellowship provided by the European Research Consortium for Informatics and Mathematics (ERCIM). Characteristics: Over 100,000 hosts 1/10/100 Gb/s links