Powered Surgical Instruments

Slides:



Advertisements
Similar presentations
Construction Safety Part 5: Hand and Power Tool Safety.
Advertisements

Power Tools Safety. Portable Circular Saws Stock must be well supported in such a way that the kerf will not close and bind the blade.. Thin materials.
2 Fire Fighter Qualifications and Safety Skill Drills.
Drill Press and Hand Drills Team 2165 Docu-Mentor-y September 15, 2008.
Cutting and Threading Steel Pipe
Shop training Band saw Drill press Tapping holes Belt sander Gluing plexiglass Soldering Projects.
Stanley DS11 Diamond Saw.
Machine Shop Hazards, Machine Tool Safety
Module B: Presentation Relating Safety to Robotics Engineering Department of Defense Education Activity Robotics Engineering – CTE502 Career and Technical.
© Business & Legal Reports, Inc Alabama Retail is committed to partnering with our members to create and keep safe workplaces. Be sure to check out.
Power/Hand Tools Valley City State University | Facilities Services | OSHA Office of Training & Education.
What is the autoclave thing again. Sanitization: fancy word for Cleaning Removing of foreign material Dirt, body fluids, lubricants Using detergents,
Band Saw Safety Rules. Safety Rule #1 Keep all guards in place. Keep all guards in place.
Manufacturing Technology Safety: Band Saw. Safety Rule #1  Keep all guards in place.
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
Bloodborne Pathogens Healthcare Workers Slide Show Notes
Tools – Hand and Power.
Orthopedics  Is the study of the musculoskeletal system.
Hand and Portable Power Tools 29 CFR, Subpart P
Hand Tool Safety Slide Show Notes
STERLIZATION AND CROSS INFECTION CONTROL IN THE DENTAL PRACTICE: part 2 BY. DR HINA ADNAN DNT 362.
Sharps Safety & Neutral Zone Main Image Here Sherri Alexander, CST Past President, Association of Surgical Technologists Recommended Practices from the.
Dr. Saleem Shaikh.   Defn: Cross infection can be defined as the passing of one infection causing microorganism (bacteria, viruses, fungal spores, etc.)
SAFE USE OF DIATHERMY RACHEAL AFOLABI, RN, RM, H. Dip. PERI-OPERATIVE NURSING, H.Dip. HEALTH SYSTEM MANAGEMENT.
Providing First Aid for Bleeding Wounds
SAFETY RULES AND PROCEDURES FOR POWER TOOLS INDEPENDENCE MIDDLE SCHOOL TECHNOLOGY EDUCATION DR. HURD 2010.
SE07.01 safety Wear proper clothing Avoid loose fitting clothes Avoid neckties and jewelry Put up or wear long hair under a cap Safety eyewear based.
Hand and Power Tool Safety. DIFFERENCE BETWEEN Hand Tools AND Power Tools 4 Hand tools Have no power source, other than the physical force applied by.
Teknologi Dan Rekayasa
HAND AND POWER TOOL SAFETY
Chesapeake Bay Perioperative Consortium 2017
Band Saw Safety Rules.
WELCOME ..
Tools and Equipment Fundamentals
Hand & Power Tool Safety
Nail Gun Coach Ketcham Productions.
Safety Test.
Drill Press Coach Ketcham Productions.
Safety Poster Coach Ketcham Productions.
Flexible Manufacturing
Infection Control 111 Methods.
Power Tool Safety Don’t operate a machine until:
Band Saw Safety Rules.
Appendix A Safety Appendix Heat or Fire
Year 10 CDT Workshop Tool Book
Chapter 70 Nursing Care for Patients with Bone Fracture
Principles of Architecture & Construction
Module 9: Microscope Maintenance
Drill Press Safety.
Safety.
LAB SAFETY.
SAFETY FIRST.
Lab Safety.
Band Saw Safety Rules.
Lab Safety Rules to learn by!.
Sharps Safety & Neutral Zone
Band Saw Safety Rules.
Hand & Power Tools, Subpart I
Circular Saw Safety By Jessie Vo.
Band Saw Safety Rules.
1.01 C The Pathway to Kitchen Safety
HAND AND POWER TOOL SAFETY
Lab Safety.
Bellwork: Mon. Aug. 13, Arachnophobia:________________
Identifying Hazards in Agricultural Mechanics
Safety In the Science Lab
Safety In the Science Lab
Essentials of Fire Fighting Maintenance and Testing Responsibilities
Smart DIYers protect themselves
Presentation transcript:

Powered Surgical Instruments CHESAPEAKE BAY PERIOPERATIVE CONSORTIUM Property of Chesapeake Bay Perioperative Consortium, © 2017

Objectives The learner will be able to: Identify current applications of powered surgical instruments Describe basic components of powered surgical instruments Identify the mechanisms of action of powered surgical instruments Discuss care and handling of powered surgical instruments

Power Equipment Power equipment ranges in type from electrosurgical units to high-technology laser units. Which includes : Power drills Saws Specialized light sources

Uses of Powered Instruments Precision Drilling - Insert screws, wires, pins Precision Cutting -side to side, front to back -obtaining bone graft -Amputation Sculpting -Reamers -Burrs

Uses of Powered Instruments Shaving -smoothing joint surfaces -skin grafts Ultrasonic Cell Disruption -Cataract- (Phacoemulsification) -Brain Tissue (CUSA-cavitron ultrasonic surgical aspiration -Lithotripsy (Kidney stone)

Specialty Uses Orthopedics -Reciprocating Saws - Oscillating Saws - Saggital Saw - Rotary attachments -Reamers, Drills - Screwdriver - Wire Drivers - Rasps - Osteotomes - Power rongeurs

Specialty Uses cont. Thoracic •Neurosurgery - Sternal Saw - Craniotome •Plastic Reconstructive - Perforator - Dermabraders - Drill - Dermatomes - Midas Rex •Oral/Dental - High speed drill/burrs - Drills - Saw

Power Source Compressed air/Nitrogen - centrally supplied - tank with gauge Electrical Battery Sonic Energy (generator)

Advantages Enables surgeon to work with greater efficiency. Causes less trauma to tissues and surrounding structures. Reduces blood loss from bone. Decreases surgical time. Reduces fatigue for the surgeon. Patient under anesthesia for a shorter period of time.

Disadvantages/Dangers Heat Generated from drill can damage bone cells High speed disperses fine mist of bone and blood Normal tissue and operators fingers may be caught in drill or saw. Air Hoses may whip out of control if defective or not attached properly.

Handling and Safety All powered equipment must be checked by Bio-medical engineering. Examine air hoses for integrity. DO NOT use if s/s of wear and tear. Inspect batteries for corrosion or other damage/defects. Inspect accessories for intactness & sharpness of cutting edges.

Handling and Safety Cont.. All power equipment should be inspected by the user before and after each use. Power cords should never be crimped or bent; any tears or breaks in the cord should negate the use of the cord until it is repaired cords should lie flat on the floor Extension cords should be avoided and power

Handling and Safety Inspect accessories after use for intactness Inspect straightness of accessories Wear PPE during use Use tissue protectors/burr guards Never leave the trigger out of the safety mode when not in use

Handling and safety Cont.. Inspect accessories after use for intactness. Inspect straightness of accessories. Wear PPE during use. Use tissue protectors/burr guards. Never leave the trigger out of the safety mode when not in us.

Handling and Safety cont. Place powered equipment on a separate table when not in use. Operate equipment only at manufacturer’s recommended setting. “Bleed” attachments before detaching from compressed air source.

ALWAYS TEST THE INSTRUMENTS WITH THE ACCESSORIES ATTACHED TO IT BEFORE HANDING IT TO THE SURGEON

Troubleshooting Power source Hose, cord, or battery Hand piece Check components in the following order: Power source Hose, cord, or battery Hand piece Accessory attachment Controls and/or safety switch

Care and Cleaning Concurrent cleaning during case. DO NOT IMMERSE HAND PIECES IN WATER Concurrent cleaning during case. Use water, not saline for wiping. After case, clean immediately. Dried-on organic material will hamper action of disinfectants and sterilization processes.

Care and Cleaning Leave air hoses attached during cleaning to prevent entry of moisture into motor Remove accessories prior to cleaning Wipe surfaces of hand pieces, cords, hoses with mild detergent/disinfectant recommended by manufacturer

Care and Cleaning Pay special attention to cannulated areas. Rinse carefully w/ water to avoid moisture to motor, holding instrument nose-down Dry with soft cloth If using ethylene oxide sterilant, dry thoroughly to prevent ethylene glycol formation

Lubrication Follow manufacturers recommendations. Use recommended products. Some instruments need to be run during or after lubrication.

IMPORTANT! All instruments and devices used in surgery should be cleared by the US Food and Drug Administration (FDA) for use in surgery and have written, manufacturer-validated cleaning and decontamination instructions for use (IFU).

References Rothrock, J, C. Alexander’s Care of the Patient in Surgery.14th ed. St. Louis,MO: Mosby;2011. Guideline for Cleaning and Care of Surgical Instruments.In: Aorn Guidelines for Perioperative Practice. AORN, Inc, 2017.