EMI Analysis & Debugging Solution

Slides:



Advertisements
Similar presentations
Safety for electronic systems High-frequency Filtering of DC Power Lines Technical, constructional and practical issues with filtering on dc power lines.
Advertisements

CHAPTER 3: SPECIAL PURPOSE OP-AMP CIRCUITS
BIOPOTENTIAL AMPLIFIERS
A design technique of ARCP matrix converter using circuit simulator Nagasaki University Yuichiro Nakazawa.
Power e Lab PowerELab Limitedwww.powerelab.com 1 An Active EMI reduction IC WT6001 POWERELAB LIMITED A Power Converter Technology Provider.
1 New high permeability materials for EMI suppression February 2011 February 2011.

MODULAR SMPS POWER PLANT
Switching Power Supply Component Selection
Smith Chart.
EE136 Project Subject:Soft start & E.M.I. Prof. D Zhou Student: Dan Lee Date:Dec. 6 th,2003.
ULg - EMC Lab Cost 286 Wroclaw1 Research activities in Liège Ir. V. Beauvois, Ir. S. Coets, Ir. M. Renard and Ir. Ph. Camus
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
Team Members Jordan Bennett Kyle Schultz Min Jae Lee Kevin Yeh.
EMC EMC of Power Converters Friday 9 May 2014
RF Equipment AFFORDABLE, SIMPLE, RELIABLE.. Compact and Reliable All of our equipment is packaged in sturdy powder- coated aluminum cases just a few inches.
Electromagnetic Compatibility of a DC Power Distribution System for the ATLAS Liquid Argon Calorimeter G. BLANCHOT CERN, CH-1211 Geneva 23, Switzerland.
Conducted Emissions and Susceptibility Conducted emissions are simpler to investigate than radiated emissions because only the product’s power cord needs.
Industrial Electrical Engineering and Automation Structures of the Energy flow system Mechatronics 2007.
8000 Series Options/Technical Overview Series Precision Digital Multimeter New Technology – Multi Processor design No need for AutoCal – High precision.
1 2 nd Virgo+ review, Cascina 17/10/2007 H. Heitmann New Quadrant Diodes New Quadrant Diodes Motivations & Requirements Status & Plans: see Nikhef talk.
Advances In Millimeter Wave Measurements Banded Differential and Pulse Measurements.
Mixed-Type Output Capacitors & Noise Mitigation
Codan 5700 Series C-Band Transceiver Technical Overview.
Electromagnetic Compatibility Test for CMS Experiment. Authors C. Rivetta– Fermilab F. Arteche, F. Szoncso, - CERN.
TS9975 Konyang University 20 th July to 22 nd July 05.
Power Supplies, Batteries, Connectors and Test Equipment.
1000 Series Ultra-Portable Multi Function Calibrator Portability, without compromise.
BASIC INSTRUMENTS - oscilloscopes
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
Radio Frequency Osc.. 2- RADIO-FREQUENCY OSCILLATORS Radio-frequency (RF) oscillators must satisfy the same basic criteria for oscillation as was discussed.
PXD – DEPFET PS noise emission tests Mateo Iglesias Fernando Arteche.
F. Arteche EMC: Electronics system integration for HEP experiments (Grounding & Shielding)
FUNCTION GENERATOR.
Challenges and solutions for Impedance measurements Guillaume Granet FE specialist April Agilent Technologies.
EMC review for Belle II (Grounding & shielding plans) PXD system - July 2012 Dr. Fernando Arteche.
Piero Belforte, CSELT 1999: AEI_EMC_, EMC basics by Flavio Maggioni.
New Electric Actuators EA Type
Single Ended Measuring Modes of ELQ 30A+
IEEE NPEC SC2 Equipment Qualification Electromagnetic Compatibility Compliance Type Test-Design Considerations- Installation and Mitigation Standard/Guidance.
FCC DIGITAL 1ch VIDEO&1ch AUDIO LINK PRODUCT SPECIFICATION
Switched-mode power supply charger
What they are What they do How to apply
NSG 4070 Signal generator and immunity test system Dr. Heinrich
NV Series Transmitters Theory of Operation
Entrance to EMI.
Balaji engineering college Special transformer
(4) Filters.
Grounding.
System Network Structure
(5) DMM & Oscilloscope.
FCC DIGITAL 2ch VIDEO & 1ch AUDIO / 1ch DATA LINK
Block Diagram Transmitter Receiver × 2 Transmitter Power Supply ADC
EET 422 EMC & COMPLIANCE ENGINEERING
EET 422 EMC & COMPLIANCE ENGINEERING
FCC DIGITAL 1ch VIDEO&1ch AUDIO/1ch DATA/1ch TELEPHONE LINK
EMI studies of different switched converters: setup and lessons learnt
EMC Lab presentation.
Peter Dennis – Dover PPM Communications
Amateur Extra Q & A Study Pool
Gadget Hub Power (mains) Controller.
IF13 series: Power cord with Input EMC Filter
AM-7027 Up Converter-Amplifier
AM-7026 Down Converter-Receiver
Chapter 4 – Operational Amplifiers – Part 1
SN-553 Frequency Synthesizer
PowerLogic™ offer for the basic metering market
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
724 Temperature Calibrator
Presentation transcript:

EMI Analysis & Debugging Solution March 2016 EMI Analysis & Debugging Solution

Core Technology 20 World Patents on EMC Techniques Since 1999 ~ Filter Design and Analysis Instrument EMI Noise source Separation Instrument Spectrum Analyzer with the noise source Separation Function Since 1999 ~ EMCIS Market Military Aerospace University Research Lab Automotive Telecommunication Semi Conductor 6 Overseas Distributors

EMI Analyzer World-FIRST EMI solution provider Capable of perfect EMI Noise solution Enabling EMI component selection in advance Model : EA-300 Noises from EUT through LISN is displayed on EMI Receiver and the displayed noise is the mixture of Common-Mode(CM) noise and Differential-Mode(DM) noise. Because two different type of noises are shown as the mixed results, it is not-an-easy target to reach EMI solution(debugging)., causing a lot of time and effort (Try and Error). By measuring and analyzing each noise (CM & DM) respectively, the approach to the solution can be clearly correct and accurate path. The solution results – in general, EMI Filters - can be designed easier, quicker and in accurate performance. Furthermore, the solution is possible to be proved by theoretic and visual data. Key Characteristics of EMI ANALYZER Analyzing EMI noises in characteristics respectively, Common-Mode(CM) and Differential-Mode(DM) EUT Source Impedance Analysis Most powerful EMI Debugging Instruments Components performance Evaluation (Coil and Capacitor) Trial EMI Filter Design and performance simulation Providing Insertion Loss graph of the selected components Theoretic Noise analysis and Solution approach System Configuration Impedance module

EMI Analyzer EA-300 EA-2100 EA-100 * 1). EA-2100 ; 4 Front Button Control EA-100 ; 1 Front Button Control

Line Impedance Stabilization DESIGNED TO CISPR16-1-2 REQUIREMENT EMCIS’ OWN UNIQUE FUNCTION (Test & Analysis mode) Characteristics Specification EUT EMI Analyzer Spectrum Analyzer LISN LN2-16N Frequency Range 9kHz~30MHz Artificial Hand Yes Supply Line/Phase 2 / 1 Network 50Ω / 50uH+5Ω+250uH Inductance 16A Max. Voltage 250V Power frequency DC~60Hz Output mode Test, Analysis RF output BNC 50Ω Phase / Lines 1/2 Dimension W355 D145 H325 (mm) Weight 10.5 kg LISN(Line Impedance Stabilization Network) is used in test of Conducted Emission noise measurement, carrying noises generated from power line, to EMI receiver. LISN supply the power to EUT ; isolates the EUT from interference from external power source ; stabilizes the line impedance ; provides a 50Ohm RF output for connecting it to EMI receiver. Design equal circuits per lines (Live and Neural in single phase) Satisfy CISPR16-1-2 requirements. As EMCIS’ own unique function, LISN has the two different mode selection, Test mode(L1 & L2) and Analysis mode (Common-Mode & Differential-Mode). Test mode is for same application as conventional LISN and Analysis mode is for application combined with EA-2100, DM and CM mode noise separation. Front control panel

Line Impedance Stabilization CISPR 16-1-2 CISPR 25 Vehicle LN4-50N / 100A LN1-100C MODEL LN4-50 LN4-100 Frequency Range 9kHz~30MHz Power in/output Terminal Type Artificial Hand 220pF +510Ω Supply Line/Phase 4 / 3 Network Inductance 50Ω/50uH + 5Ω ±20% Coupling Capacitor 0.25uF Max. Current 50A 100A Max. Voltage AC 60Hz : 380V DC : 530V AC 400Hz : 75V Line to Earth Power frequency DC~60Hz, 400Hz Output mode Test, Analysis RF output BNC 50Ω Phase / Lines 3/4 Dimension W705 D500 H261 (mm) W720 D634 H242 (mm) Weight 60 kg 50 kg Frequency Range 150kHz~108MHz Max. Voltage DC 600V, AC 250V 60Hz Max. Current 100A Network 50Ω / 5uH+1Ω Supply Line / Phase 2 / 1 Impedance Tolerance ± 20% Phase Tolerance ± 11.5° RF Output Connector N type 50Ω Female Dimension W139 D308 H118 (mm) Weight 4.3 kg Analysis control panel Hand-hold type In/Output connection

Hand-hold type In/Output connection Line Impedance Stabilization MIL-STD-461E/F CISPR 16-1-2 LN1-50 / 100 LN2-50N / 100A MODEL LN1-50 LN1-100 Frequency Range 10kHz~10MHz Power in/output Terminal Type Supply Line/Phase 2 / 1 Network Inductance 50Ω/50uH + 5Ω ±20% Coupling Capacitor 0.25uF Max. Current 50A 100A Max. Voltage AC 60Hz 440V DC 530V AC 400Hz 115V(Line to Earth) Power frequency DC~400Hz Output mode Test, Analysis RF output N-Type 50Ω Dimension W400 D500 H280 (mm) W420 D520 H300 (mm) Weight 10.5 kg 13.8 kg MODEL LN2-50N LN2-100A Frequency Range 9kHz~30MHz Power in/output Terminal Type Artificial Hand 220pF +510Ω Supply Line/Phase 2 / 1 Network Inductance 50Ω/50uH + 5Ω + 250uH Coupling Capacitor 0.25uF Max. Current 50A 100A Max. Voltage AC 250V Power frequency DC~60Hz Output mode Test, Analysis RF output BNC 50Ω Dimension W300 D705 H262 (mm) W350 D530 H241 (mm) Weight 30 kg 28 kg front control Hand-hold type In/Output connection

DC–LISN for Photovoltaic Inverter Switch for Network-V-Y-Delta type Continuous DC 100A Dual Line Characteristics Specially design for Solar Power system application, using in test of Conducted Emission noise measurement, carrying noises generated from power line, to EMI receiver. LISN supply DC power to GCPC ; isolates the EUT from interference from external power source ; stabilizes the line impedance Design equal circuits per lines (Live and Neural in single phase) Operation continuously in Dual Line-100A Satisfy CISPR16-1-2 requirements. As EMCIS’ own unique function, LISN has the two different mode selection, Test mode(L1 & L2) and Analysis mode (Common-Mode & Differential-Mode). Test mode is for same application as conventional LISN and Analysis mode is for application combined with EA-2100, DM and CM mode noise separation. LN2 – 100T Specification Frequency Range 150kHz~30MHz In/Out Connector Terminal-type Supply Line 2 Network Impedance CM:150Ω±20Ω, DM:100Ω±20Ω Phase 0°±40° Insertion Loss > 20dB (EUT~AE) LCL > 26dB Voltage Division Factor 20dB±2dB Max Current 100A Max Voltage DC1500V Mode Selector L1, L2, CM, DM RF Output N-type Dimension W355 D143 H320 (mm) Weight 10.5 kg

FILTER ANALYZER FA-300 CISPR17 and/or MIL-STD-220B Measurement Analysis of EMI Filter Characteristics(Auto) CISPR17 and/or MIL-STD-220B Measurement Spectrum Analyzer installed Frequency Range : 9kHz – 300MHz Characteristics Specification EMI Filter Characteristics Analysis Filter Spec and Quality Control Measure and Analyze CM and DM mode function Attenuation Capabilities Check Satisfy CISPR17 and MIL-STD-200B measurement Data Load/Upload/Edit function Test Report Saving Easy and simple design in operation process – Wide Display & Touch Screen Extended application for components measurement Mostly powerful instruments for Filter Manufacturer Display screen Filter Test Specification subjects to change without notice

Characteristics of Differential-mode Filter Filter Analyzer FA-2100 EMI Filter Characteristics Analysis CISPR17 and/or MIL-STD-220B Measurement Frequency range 10kHz ~ 300MHz Characteristics Specification EMI Filter Characteristics Analysis - Filter spec and quality control Measuring and analyzing DM and CM mode function and attenuation capabilities of EMI filters. Analyze attenuation characteristics of each components like Inductors, Choke Coil, X-Capacitors, Y-Capacitors Using combined with Network Analyzer and/orSpectrum analyzer equipped Tracking Generator CISPR17 and/or MIL-STD-220B Measurement Frequency range from 10kHz to 300MHz Easy and simple design in operation process –front display panel and push-button Frequency Range 10kHz ~ 300MHz Mode Selector CISPR17 .MIL-STD-220B Test Mode Differential , Common Signal loss 10kHz~30MHz < 3dB 30MHz~300MHz < 5dB CM/DM Separation 10kHz~30MHz < 40dB 30MHz~300MHz < 30dB Input sensitivity -97dBm (10dBuV) Max RF Input 23dBm (130dBuV) Filter Input / Output 2 SMA Connector Display Front panel VFD display Front panel control 4 Button control Input impedance 50Ω Input Dynamic Range 120dB Connector BNC 50Ω Test Table (FA-001) Slide Door Input Voltage AC100V~ 240V 50/60Hz 10W Dimension W365 D330 H150 (mm) Test Table - Specifications subjects to change without notices Characteristics of Differential-mode Filter

Conducted Reference Source CRS-1530 Providing reference source Avoiding measurement errors Comparing measurement site circumstance (EMC Lab ) Characteristics Reference Signal Provides Reference sources to measuring instruments checking set-up defaults conditions of LISN, cables, etc. Avoids, in advance, any uncertainty in measurements, causing measurement errors Usable without changing of set-up condition on EMI measurement Application * Authorized EMC Lab * Private EMC Lab * Research Lab/institutes * University/Colleges * Industries * Others Specification Frequency Range 150kHz~30MHz Power DC 12V Battery Output Level 50dBuV ±3dBuV Frequency stability Quartz drive Low Voltage Detection Buzzer Power Indicator LED Operating Temp range 15℃ ~ 55℃ Dimension W65 D65 H120 (mm) Weight 300 g Connection Spectrum Analyzer or EMI Receiver CRS-1530 LISN - Specifications subjects to change without notices

Multi Power Line Interference Probe MP-930 Usable on both power source, AC/DC Easy measurements on power line and the path noises Characteristics Specification Capable to measure noise level at each line-end. Capable to use on standard 440V 3Ph AC line, max 275VAC(rms) between line and ground, both AC/DC. Measurable from 9kHzto 30MHz, without RF Amp Useful when EUT is required high current ; when the measuring circumstance is not easy to use LISN Usable with Spectrum analyzer Minimizing the possible tolerance in low frequency noises, by adopting HPF(High Pass Filter). Frequency Range 9kHz ~ 30MHz Input voltage AC220V 50/60Hz, DC380V Input current 63mA AC50Hz(nom) 0.8mA DC max Input dynamic range 70dB Insertion loss 100kHz~30MHz 2dB Output connector BNC Test Voltage DC1500V Temperature range -5°C to 55°C Relative humidity 20% to 80% Dimension W38 D23 H9 (mm) Test Table 2.6 kg System Set-up With EMI Analyzer MP-930 EMI Analyzer (EA-2100) Spectrum Analyzer L1 GND L2 Insertion Loss Capable to analyze/measure Total, DM, CM noises and their levels. With Spectrum Analyzer/ Receiver MP-930 Spectrum Analyzer L1 GND L2 Connecting with Line1, Line 2 and measure total noise level – only possible to measure total noise - Specifications subjects to change without notices

DC Bias Source DCS - 50D Characteristics Specification Analysis of Inductor and/or Transformer functional characteristics Digital control from 0~20A, at 10mA step Optional extended range from 10kHz~30MHz. Use with Impedance Analyzer or LCR Meter. Attenuation measurement (Max. 100MHz) Suitable Inductor and/or Transformer design. Useful in quality control. MODEL DBS-50D Frequency Range L , Z : 10kHz~30MHz Attenuation : 10kHz~100MHz Current Range 0~50A Steps of 10mA Measured L , Z Attenuation Power Supply AC 220V 60Hz Coupling Capacitor 0~35°C Dimension W530 D539 H215(mm) Weight 58 kg Accessories DBS-03CB, SMA-MM-400, DBS-03CL (10kHz ~ 5MHz) DBS-03EB, N20-MM-600, DBS-03EL (10kHz ~ 30MHz) DBS-003A : Attenuation measurement (10kHz ~ 100MHz) BNC-MM-1000 : BNC to BNC Cable (1m) DBS-Terminal : Terminal type DBS-SMD : SMD measurement Note : - L, Z measurement : using with LCR Meter , Impedance Analyzer - Attenuation : Spectrum Analyzer ,Network Analyzer System configuration LCR Meter or Impedance Analyzer DC Bias Source Adaptor DUT - 13 -

DC Bias Source DBS-20D/50D System Configuration Accessories LCR Meter Impedance Analyzer Accessories DBS-03CB 400mm DBS-03CL 10kHz~5MHz Measurement Accessories DBS-03EB N20-MM-600 DBS-03EL 10kHz~30MHz Measurement Accessories DBS-003A (Attenualtion) BNC-MM-1000 (1m) DBS-Terminal, DBS-SMD - 14 -

EMI Filter Excellent filtering characteristics EMCIS designs and supplies the Accurate filters what customers want, using EMCIS’ own measuring Instruments and software. No limit on application ; Industrial, Telecommunication, Military, Automotive DC~AC 440V 1Ph, 3Ph, 1A~400A , 10KHz~ 10GHz