Means of Egress and Fire Protection

Slides:



Advertisements
Similar presentations
OSHA Office of Training and Education
Advertisements

Emergency Preparedness and Response
OSHA Regulations Part 1910 Subpart E
Emergency Action And Fire Prevention
Emergency Action Plans
Fire Protection OSHA Part 1910 Subpart L.
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
FIRE PREVENTION & PROTECTION
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
Subpart E Means of Egress.
Coverage and definitions. (a) Every employer is covered
Means of Egress and Fire Protection. 2 Objectives Understand Alarms and Warning Devices Know the location of Exits and Exit Routes Understand the RACE.
Means of Egress Fire Prevention and Protection
HOT WORK PROCEDURES Welding and Hot Work, such as brazing or grinding present a significant opportunity for fire and injury. CCR Title 8 Sub Chapter 7,
1. Introduction 1.1. Fire program management involves the identification, evaluation, and control of hazards which may result in a fire OSHA & Emergency.
Objectives Design and construction requirements for exit routes
Fire Protection John Giefer. Statistics In the Drilling Industry In the Drilling Industry 25% of all inspections found violations of (21 inspections.
1 Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
PERMIT REQUIRED CONFINED SPACES PERMIT REQUIRED CONFINED SPACES.
Emergency Action Plans/Fire Prevention Plans
Emergency Response José A. Carpena, PE Area Director Puerto Rico Area Office Occupational Safety and Health Administration 2005 SWRI Annual Meeting.
Emergency Action Plans
Employee Emergency Action Plans and Exit Routes Training Program.
EGRESS AND FIRE PROTECTION
Business Owners and Managers and the Fire Code

Means of Egress and Fire Protection
NO EXIT (adapted from OSHA Office of Training and Education)
1/05 Means of Egress WAC School Safety Training.
New Hire Initial Fire Safety and Prevention Training MHPHRM BR
Safety Training Presentation
Hot Work Procedure Training
ASSURANCE PINNACOL ASSURANCE Wants you to know about : EMERGENCY/DISASTER PREPAREDNESS.
Hot Work Procedures Fire Control. Cutting and Welding Where practicable all combustibles shall be relocated at least 35 feet from the work site Where.
Subpart C General Safety and Health Provisions 29 CFR 1926.
Means of Egress and Fire Protection. Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long.
When to use, how to use. Objective To make all employees aware of the danger posed by fires, and when and how to use fire extinguishers safely SAFETY.
Exit Routes and Fire Protection
Emergency Action Plans
Means of Egress and Fire Protection
OCCUPATIONAL SAFETY AND HEALTH Do you remember those school fire drills ? Well, here you go again !
Means of Egress Don Ebert- Risk Manager (509)
EGRESS, FIRE PREVENTION & FIRE PROTECTION OSHA 29 CFR 1910 SUBPARTS E & L Bureau of Workers’ Comp PA Training for Health & Safety (PATHS) 1PPT
Department of Defense Voluntary Protection Programs Center of Excellence Development, Validation, Implementation and Enhancement for a Voluntary Protection.
Hot Work Permit Osan AB Fire Emergency Services.
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
Emergency Preparedness & Response
Hazard Communication This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers.
Emergency Action Plans
N.C. Department of Labor OSH Division
Personal Protective Equipment in General Industry
SERVICES, LLC 1 1.
Top 10 Most Frequently Cited Serious Violations in FFY 2015
Multi-Employer Worksites in Construction
Fire Brigades.
Table of Contents for Subpart E Coverage and Definitions
OSHA Office of Training and Education
OSHA Office of Training and Education
Most Frequently Cited Serious Violations
Most Frequently Cited Serious Violations
Most Frequently Cited Serious Violations
Public Employee Safety & Health Bureau (PESH) Consultation Assistance
29 CFR NFPA Life Safety Code
Most Frequently Cited Serious Violations
مایعات قابل اشتعال و احتراق پذیر
General Requirements of NFPA 101
OSHA Regulations Part 1910 Subpart E
OSHA Office of Training and Education
Hot Work Procedures Fire Control.
Presentation transcript:

Means of Egress and Fire Protection This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target audience, this presentation emphasizes hazard identification, avoidance, and control – not standards. No attempt has been made to treat the topic exhaustively. It is essential that trainers tailor their presentations to the needs and understanding of their audience. This presentation is not a substitute for any of the provisions of the Occupational Safety and Health Act of 1970 or for any standards issued by the U.S. Department of Labor. Mention of trade names, commercial products, or organizations does not imply endorsement by the U.S. Department of Labor.

Introduction There is a long and tragic history of workplace fires in this country caused by problems with fire exits and extinguishing systems OSHA requires employers to provide proper exits, fire fighting equipment, and employee training to prevent fire deaths and injuries in the workplace In 1995, more than 75,000 workplace fires cost businesses more than $2.3 billion Means of Egress: 29 CFR 1910 Subpart E Fire Protection: 29 CFR 1910 Subpart L More complete information on means of egress can be found in the National Fire Protection Association document: NFPA 101: Life Safety Code

Escape Route the way of exit access; the exit; and A continuous and unobstructed way of exit travel from any point in a building or structure to a public way (a street, yard, court or other open space leading to the street) Three parts to an escape route: the way of exit access; the exit; and the way of exit discharge. 1910.35(a) Another term for “means of egress” is “escape route.” Emphasis is on escaping from fires, however some additional hazards include: Explosion Earthquake Bomb threat Toxic vapors Storms (tornadoes, hurricanes, etc.) Compounding factors that may interfere with safe escape include: Panic and confusion, Poor visibility, Lack of information, and Misinformation. These factors frequently cause more injuries and fatalities than the hazard itself.

Exit Access, Exit & Exit Discharge Occupant: Exits - Doors at A1, A2, E1 & E2 Emerging Person: Exit Discharge Doors at D1 & D1 Exit Access: Noted by dashed lines Exit Discharge: Noted by dotted lines Area within the exit: Solid lines

Escape Routes General Requirements Fire alarms are required if a fire could start without providing adequate warning to occupants There must be enough exits in the proper arrangement for quick escape Adequate and reliable illumination must be provided for all exit facilities Escape Routes: Minimum width = 28 inches Minimum ceiling height = 7-½ feet 1910.36(b)(1), (6) & (7) 1910.37(f)(6) 1910.37(i) Fire alarms also facilitate the orderly conduct of fire exit drills.

Locked and blocked exit Locking Exits Must not install any lock or fastening that impedes or prevents escape from the inside of any building. Locked and blocked exit 1910.36(b)(4) There is an exception for mental, penal, or corrective institutions where there is constant supervision.

Access to Exits Exits must be readily accessible at all times A door from a room to an exit or escape route must be a side-hinged swinging type, and swing in the direction of exit travel when the room is occupied by more than 50 people or contains high hazard contents 1910.37(f)(1) & (2) High hazard contents are those which are liable to burn with extreme rapidity or which may produce poisonous fumes or explosions in a fire. Examples include flammable chemicals and grain.

Maintaining Escape Routes Escape routes from all parts of the building must be continuously maintained free of all obstructions in case of emergency. Obstructed exit 1910.37(k)(2)

Exit Marking Exits must be marked by a readily visible sign when the exit or way to reach it is not immediately visible to occupants. 1910.37(q)(1)

Exit Marking (cont’d) If a door, passage, or stairway is not an exit or a way of exit access, but may be mistaken for one, it must be identified by a sign reading “Not an Exit”, “Storeroom”, “To Basement”, etc. 1910.37(q)(2)

Exit Marking (cont’d) A sign reading “Exit” with an arrow indicating the directions must be placed in every location where the direction of travel to the nearest exit is not immediately apparent. 1910.37(q)(5)

1910.38(a) Employee Action Plan Minimum Content: Written (except for 10 or less employees) Emergency escape routes, procedures & assignments Procedures for employees who remain for critical tasks Head count Rescue & medical duties Emergency reporting procedure Whom to contact for additional information

1910.38 Emergency Action Plan Training Requirements Before implementation & annually Changes in duties & responsibilities Changes in plan

1910.38(b) Fire Prevention Plan Minimum Content Written (except for 10 or less employees) List of workplace fire hazards Potential ignition sources Control procedures Fire detection & suppression systems Critical maintenance personnel & equipment maintenance requirements Personnel who control fuel sources Housekeeping procedures Initial & follow-up training

Fire Brigades 1910.156 Written Policy Statement shall include: Organizational statement as to structure Functions to be performed Training requirements Medical evaluation PPE requirements

Fire Brigade Training Requirements Conducted prior to job assignment Annually for all Brigade Members Quarterly for Interior Structural Fire Fighters

OSHA 1910.251 - 257 Hot Work General Principles: Combustibles at least 35 feet from work site or Cover to prevent contact with heat, sparks, slag Fire extinguishers readily available Protect floor & wall openings Post fire watch Authorize work with permit Prohibited if sprinkler systems are out of service

OSHA 1910.251 - 257 Fire Watch Required when there is potential for significant fire Extinguishing equipment readily available Trained in use of fire extinguishing equipment Know how to sound alarm Fight only incipient stage fires Remain at post for 30 minutes after work stops Know how to shut down welding & cutting equipment

Sample Permit

Sample Permit

Sample Permit

Sample Permit

Hazardous Locations