Planing a PET Imaging Centre: Radiological Protection Requirements

Slides:



Advertisements
Similar presentations
Radiation Protection Legislation Stephen McCallum
Advertisements

Radiation Protection.
Principles of Decontamination. Objectives Define contamination and decontamination Differentiate between the concepts of exposure and contamination Identify.
1 Radiological protection, dosimetry & environmental monitoring National Training Course on Radiopharmacy, Radiochemistry and Radioisotope Production Site.
32 P Module Objectives  To understand the physical nature of 32 P.  To understand the 32 P is both and internal and external radiation hazard.  To understand.
Iodine 125.
FPS HEALTH, FOOD CHAIN SAFETY AND ENVIRONMENTFPS PUBLIC HEALTH, FOOD CHAIN SAFETY AND ENVIRONMENT Medical Imaging Federal initiative Dr Aldo Perissino.
MARKETS AND ABATTOIRS The construction sites should be free of nuisance conditions, contamination, should have available adequate water supply for cleaning.
(Control of Substances Hazardous to Health Regulations,2004)
Radiation Safety Reminders During Nuc. Med. Procedures ALARA Practices By Aggie Barlow, CHP, MBA, MS.
National Committee for the Certification of Radiation Protection Officer SAFETY AND WORK PROCEDURE IN SALES OF RADIOACTIVE MATERIAL AND IRRADIATING APPARATUS.
 Molecular Laboratory must have an ongoing Bio-safety SOP and also quality improvement program to monitor and evaluate objectively and systematically.
Establishment of a Training Dosimetry Laboratory in Cairo University Dr. Hassan Fathy for NSPA.
PHYSICS 345 Introduction Radiation Safety The first experiment(s)
Gauges and well logging
Alanoud M. Al-Talal Office – Pharmacy Building (8) – 2 nd Floor – Room 63 address –
Intervention for Chronic and Emergency Exposure Situations Basic Concepts of Emergency Preparedness Personal Protective Equipment, Devices and Procedures.
RADIATION SAFETY Phil Facey Lead Superintendent Radiographer
Bapetco NORM Control Case Study IDENTIFY ASSESS CONTROL & RECOVERY.
Occupational Exposure Protection of the Worker Lab # 6.
RADIOACTIVE WASTE MANAGEMENT
ANALYTICAL X-RAY SAFETY User Training Centre for Environmental Health, Safety and Security Management.
Radiation Safety Reminders During Nuc. Med. Procedures ALARA Practices By Aggie Barlow, CHP, MBA, MS.
Authorization and Inspection of Cyclotron Facilities Inspections.
 Justification is the answer.  Dose limits are not applicable only recommened.
MODULE “PROJECT MANAGEMENT AND CONTROL” RADIATION PROTECTION SAFE DECOMMISSIONING OF NUCLEAR POWER PLANTS Project BG/04/B/F/PP , Programme “Leonardo.
Government of Western Australia Department of Mines and Petroleum Please read this before using presentation This presentation is based on content presented.
IAEA International Atomic Energy Agency Radiation Protection Issues in Nuclear Installations (NPP & RR) Laszlo Sagi Radiation Safety and Monitoring Section.
/0409 Copyright ©2004 Business and Legal Reports, Inc. BLR’s Safety Training Presentations Ionizing Radiation 29 CFR
Occupational Exposure Protection of the WorkerOccupational Exposure Protection of the Worker Lab # 6.
Monitoring of Radiologically Contaminated Scrap Metal Czech experience Milan Hort State Office for Nuclear Safety Czech republic UNECE Group of Experts.
Hot Lab 11. dose calibrator, an ionization chamber used in nuclear medicine to measure the amount of radioactivity of a radionuclide before injection.
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Inspection Part II.
1. 2 Radiation Safety 3 What is Radiation? Radiation is a form of energy. It is emitted by either the nucleus of an atom or an orbital electron. It.
RADIATION SAFETY Mrs. Brinston. Introduction As a healthcare worker, you know that radiation is an important tool for detecting and treating diseases.
VIII.3. Optimization of Protection for Medical Exposures in Nuclear Medicine 1. Design considerations Postgraduate Educational Course in Radiation Protection.
Basic radiation protection & radiobiology
 Radiopharmaceuticals are agents used to diagnose certain medical problems or treat certain diseases. They may be given to the patient in several different.
Ferris State University & Michigan Department of Career Development 1 Radiation Safety Answer Key.
Radiation Sources in medicine diagnostic Radiology
Introduction to nuclear medicine technology NMT 231.
IAEA International Atomic Energy Agency. IAEA Dr. Abraham Gregorio de Rosa,Sp.Rad Radiologist in HNGV Dili, Timor Leste 2 Perspectives on regulatory models.
Introduction to nuclear medicine technology NMT 231 Aya Ahmed Saeed.
International Atomic Energy Agency ASSESSMENT OF OCCUPATIONAL EXPOSURE DUE TO EXTERNAL RADIATION SOURCES AND INTAKES OF RADIONUCLIDES Dosimetry Services.
Authorization and Inspection of Cyclotron Facilities Radiation Protection of Staff.
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Technical Services.
Module 1 Biotechnology Basics Copyright © Texas Education Agency All rights reserved.
Mu2e Target Hall Remote Handling - Contamination Control, Schedule, Risk & Conclusions Ryan Schultz Deputy L3 Manager Target Station 11/17/2015.
Working Procedure with Ionizing Radiation 1. Introduction Introduction Classification of Areas Classification of Areas Safe Handling/Use of Safe Handling/Use.
Technical Services. Objectives To identify the technical services needed within the infrastructure for an effective implementation of regulatory programme.
1 Nicolas Varmenot, PhD - PCR Medical Physicist – ICO René Gauducheau Head of risks prevention and of radioprotection – Cyclotron ARRONAX
Isotopes Dr. Enaam Kahlil.
Inventory Management Chapter 13.
EUROPEAN ALARA NETWORK
 Usefulness of  Radiopharmaceuticals Auto   Injection System (RAIS) in the PET study Jeom jin Lim Seoul National University Hospital.
Emilio Casal. Centro Nacional de Dosimetría. Valencia
Transposition of Requirements set out in the Basic Safety Standards for Nuclear Facilities in Lithuania Gintautas KLEVINSKAS Albinas MASTAUSKAS Radiation.
storage and External Transportation
AUBERT Bernard*, GUILABERT Nadine°, LAMON Annick* and RICARD Marcel*
JM Martí-Climent, I Peñuelas
TENORM Study Update Presented by Rich Janati on behalf of Dave Allard
Louisiana State University Radiation Safety Office
Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist
Radiation Protection (2)
Barndioota consultative committee meeting
Lecture 4(Unit II): Gas-Filled Detector Quality Control
Waste and Contamination
Contamination Control
The dangers of radioactivity
Radiation Protection Handbook
Presentation transcript:

Planing a PET Imaging Centre: Radiological Protection Requirements Dr. Radu A. Vasilache Canberra Packard Notes 3rd BALKAN CONGRESS OF NUCLEAR MEDICINE “Present and future in Nuclear Medicine” Bucharest, April 23rd-26th 2014

Overview Standards and legislation What to survey? Pathways of exposure Radiation protection planning Specific instruments and methods for radiation monitoring Conclusions

Standards and regulations IAEA Basic Safety Standards & ICRP Guides and Recommendations National laws and regulations: e.g. Law 111/1996 & Basic Radiological Protection Norms Set up the dose limits for exposed personnel (20 mSv/year) and population (1 mSv/year) Specific norms for each area of interest (nuclear medicine, environmental monitoring, personnel monitoring, site planning, etc.)

Who & What to Survey? Targets of the survey: Protection of the profesionally exposed: Direct exposure to external radiation – shielding calculations, dose monitoring Internal exposure through inhalation & ingestion – internal contamination (activity) monitoring → zoning, doses are calculated External contamination → zoning Protection of the patients Proper dosage Dosimetry GMP

Who & What to Survey? Protection of the public Gaseous effluents (beta – gamma, pure beta) Liquid effluents (beta – gamma, pure beta) Waste disposal External exposure

Radiation protection planing Site planing: Proper shielding: Scanner Hot room / preparation room Injection rooms Patients waiting rooms Proper patients circuit: Entrance / reception / waiting hall → consult / preparation room → injection room / rest room → scanner → waiting room (post scanning) → exit. Proper radiopharmaceuticals circuit: FDG reception → transfer to the hot room / dispensing → transfer to the injection room → disposal of the used syringes

Radiation protection planing Site planing: Proper facilities design: Special ventilation Special sewage Waste disposal Proper attendands circuits Identify points of continuous monitoring and what needs monitored Identify the proper equipment needs: basic / full / “de luxe”

Equipment needs Exposed personnel: Basic: personnel dosimetry, proper personnel shielding (including hot-cells), contamination monitoring (hand-held) Full: extra shielding, automatic dispensing (in some countries manual dispensing is not even allowed), automatic injection units De luxe: hand – feet contamination monitors, extra alarming monitors Patients: Proper dosage: automatic dispensing is a must, manual dispensing is not nearly precise enough Public: zoning, caution signs, physical barriers, proper effluent and waste handling

Equipment needs Patients: Proper dosage: automatic dispensing is a must, manual dispensing is not nearly precise enough The dispensed doses must be periodically veriffied by cross check with a second dose calibrator Dose calibrators must be periodically submited to metrology verifications Injected patients must be shielded from each other Public: zoning, caution signs, physical barriers, proper effluent and waste handling

Personnel protection Personnel dosimetry: Should be provided by an autorised personnel dosimetry lab (either with film badges, TLD badges or glass dosemeters), including extremity dosimetry Minimum investment, records should be kept for a number of years speciffied by the national regulations Extra dosimetry: Electronic personal alarm dosemeters – some countries require that operating personnel should wear also alarm dosemeters and even keep the records Area dosimetry & hand held contamination monitoring: also part of normal legal requirements, measurements fall into the responsibility area of the RPO

Examples of personnel dosemeters

Personnel contamination

Shielding In order to minimise general exposure and especially hand exposure, automatic dispensing is compulsory Hot cells for dispensers with 50 mm all arround lead shielding Shielded syringes and automatic injectors also required Images from www.temasinergie.com

Patient protection Dosimetry: Using the corect doses (activity measurement): dose calibrators, automatic dispensing Internal dosimetry: easier said then done (biokinetic models, dose factors, etc.)

Patient protection Hot cells / dispensers: EEC GMP / GAMP conformity 2. ISO 14644 – Clearooms and associated controlled environments 3. ISO 10648 – Containment enclosures 4. FS209E Standard 5. Shielding requirements (minimum lead thickness, negative pressure, etc.)

Patient protection – hot cell design Shielding GMP conformity - 2 pre-chambers - Manipulation gloves - Shielded dose calibrator - Integrated waste conteiner - UV lamp for sterilisation - Double main door (lead and plexy)

Dispensing Total activity measurement for the main / bulk vial and dilution to the desired initial concentration Dispensing the syringe and diluting it to the desired concentration Short dispening time

Dose dispensers Images from www.temasinergie.com

Dispensing and injecting Mobile dispensing and injecting stations: careful not to allow direct connection between the main vial and the patient Images from www.temasinergie.com

Dispensing and injecting Mobile dispensing and injecting stations (e.g. Karl-100): - should allow dispening into a syringe (dispensing the dose directly to the patient presents the risk that a malfunction will put the patient in direct contact with the main vial, which would be contrary to the GMP, and exposes the patient to an useless external dose) - should allow independent verification of the dispensed dose - should allow with the minimum possible injected volume (e.g. not more than 10 ml) -should allow for any lead pot to be used to avoid un- necessary exposure of the personnel when transfering the vial from one pot to the other

Dosimetry – area monitoring Ambient equivalent dose H*(10) Measured directly, usualy the dose, time stamp and location are logged in Usually applies to photons (gamma & X) and neutrons, surface contamination is subject to separate monitoring and should lead to zoning Area monitoring normally involves network monitoring, with detectors sending remotely the data, combined with periodic surveys performed by operators

Zoning The access to different areas should be subject to zoning At least 3 zones are normally established: Controlled area: personnel doses could reach and exceed a higher level (e.g. 6 mSv/year) & external contamination may occur Buffer zone: doses are above background, but will not exceed a determined level (e.g. 3 mSv/year) contamination should not occur Free on-site access zone, where doses should be in the background level, and contamination must not occur

Area monitoring – hand held units

Details to be observed Dose ranges: in areas where the dose rate could have significant fluctuations, a matter of concern should be the saturation of the probes TTC methods is the answer

Time – to – count principle Conventional GM Tube Operation BIAS +HV TIME DISCR. WAVE FORMS TIME PULSE TIME Source www.canberra.com

Time – to – count principle “Time to Count” Operation t on t on Time Totalizer HV ÷ Average Time to Count HV 2 t off Pulse Totalizer t off K TIME TO COUNT RATE = TIME GM TUBE WAVEFORMS Source www.canberra.com

Time – to – count principle “Time to Count” Behaviour HIGH FIELD LOW FIELD SHORT TIME +HV +HV HV HV 2 2 LONG TIME 2 mSec. 2 mSec. TIME TIME Source www.canberra.com

Effluent & waste monitoring Should be integrated in the same RMS software as the dose area monitoring Involves mostly liquid discharges (gaseous effluents are not a big concern in sites without cyclotrons) Waste: Solid: Can be stored in a shielded place until cold Biohazard must be addressed Liquid: Separate sewage needed Dilutors are to be used until the sewage waste is cold then treated according to normal hospital regulations

Conclusions From the point of view of the radiological protection, one must observe the following in the site planing: Plan for the correct circuits for patients, incoming FDG and attendants Insure proper zoning Insure proper monitoring of personnel exposure / contamination Monitor waste production Never use manual dispensing Always check the doses dispensed by periodic cross - measurements

Thank you! ...for your attention... Questions?