Wearable Chemical Sensors: Characterization of ECG Electrodes with Electrochemical Impedance Spectroscopy Jennifer Deignan1, Michael McBrearty2, Javier.

Slides:



Advertisements
Similar presentations
UNIVERSITY COLLEGE DUBLIN DUBLIN CITY UNIVERSITY TYNDALL NATIONAL INSTITUTE Fig 1. Exampleschematic of a wireless sensor platform Current flow control.
Advertisements

OFFLINE COMPOSITION MEASURING SENSORS
Presented by MSc. Ir. Sheilla A. Odhiambo PhD student, Gent University, Department of Textiles,& Moi.
Polymer graphite composite anodes for Li-ion batteries Basker Veeraraghavan, Bala Haran, Ralph White and Branko Popov University of South Carolina, Columbia,
Fig. 22-1a (p.629) A galvanic electrochemical cell at open circuit
Lecture 6a Cyclic Voltammetry.
The integration of smart textiles enabling a non- invasive approach in monitoring the user’s vitals and activities Prof. Lieva Van Langenhove Department.
Enhanced Electrochemical Reduction of Hydrogen Peroxide at Surfactant/Salt Modified Electrodes Laura Gonzalez-Macia 1, Malcolm R. Smyth 2 and Anthony J.
Electrolytic Cell and Electroplating Chapter 19 Page Chem 12.
UNIVERSITY COLLEGE DUBLINDUBLIN CITY UNIVERSITY SMI || NCSR || CDVP Minimally Invasive Gathering of Body Context Information from Garment Interactions.
UNIVERSITY COLLEGE DUBLIN DUBLIN CITY UNIVERSITY This material is based upon work supported by Science Foundation Ireland under Grant No. 03/IN3/1361 Computing.
OK, so you’ve made the Ru complexes. Now, how are you going to determine what it does with DNA? Will your complex bind DNA, like this? Will the other complexes.
20 10 School of Electrical Engineering &Telecommunications UNSW UNSW 10 Author: James Carrapetta Supervisor: Dr Vijay Sivaraman Wireless.
Colin Mann, Physics Professor Philip Collins ABSTRACT The use of carbon nanotube field-effect transistors (CNTFETs) as chemical or biological sensors is.
UNIVERSITY COLLEGE DUBLIN  DUBLIN CITY UNIVERSITY  TYNDALL NATIONAL INSTITUTE Acknowledgement This work is supported by Science Foundation Ireland under.
Distributed Microsystems Laboratory Integrated Interface Circuits for Chemiresistor Arrays Carina K. Leung * and Denise Wilson, Associate Professor Department.
Electrochemical Glucometers
Transducers/Sensors: Sample Device Thermistor A thermistor is a temperature-sensing element composed of semiconductor material (typically a mix of metal.
Fundamentals of Electrochemistry It’s shocking!. Electroanalytical Chemistry: group of analytical methods based upon electrical properties of analytes.
Kelsey Kunkel BME 281 Section 1 October 10 th, 2012.
ICEBI ’07 ICEBI ’07 August 29th – September 2nd 2007 in GRAZ, AUSTRIA An energy efficient wearable tissue monitor ANNUS, Paul; MIN, Mart; PARVE, Toomas;
UNIVERSITY COLLEGE DUBLIN  DUBLIN CITY UNIVERSITY  TYNDALL NATIONAL INSTITUTE Recent Progress in Disposable Ion-selective Sensors for Environmental Applications.
Heart Rate Sports Fitness. Session 2 objectives To learn, discuss and identify the differences between aerobic and anaerobic activity To learn how exercising.
788.11J Presentation “Smart Jacket” Presented by Mahmoud Moneeb Azab.
1. Blood or Fluid Analysis Using carried out in central labs with problems of time delay costs and potential misslabeling Drive toward more bedside or.
Electrochemical Methods Dr M.Afroz Bakht. Potentiometry Potentiometry is a method of analysis used in the determination of concentration of ions or substances.
Samuel John Vinod Kumar CG Ganesh Raam K. Introduction  The need for health consciousness has increased in the recent past and so is the need to monitor.
Performancing enhancing clothing is seen in:
A WIRELESS PASSIVE SENSOR FOR TEMPERATURE COMPENSATED REMOTE PH MONITORING IEEE SENSORS JOURNAL VOLUME 13, NO.6, JUNE 2013 WEN-TSAI SUNG, YAO-CHI HSU Ching-Hong.
«Recent Progress on Solution Based Transparent Conducting Electrodes» Dr. Fevzihan BAŞARIR 31/03/2016 Sofia.
Electrochemistry Chapter 18. Electrochemistry –the branch of chemistry that studies the electricity- related application of oxidation-reduction reactions.
By: Dr Irannejad. 2 3 Decrease in the Gibbs Function as a Condition for Spontaneous Reaction.
PRESENTED BY: JISMA E P NO:66 S3 ECE
Design and Fabrication
ELECTRONIC TONGUE BY R.PAVAN KUMAR, RIPER-ANANTAPUR.
Advances in Electroluminescent Devices with Barium Titanate Particles
Electroanalytical Chemistry
12 Lead ECG Trainer Cali Roen, Laura Bagley, Tony Schuler, Amy Weaver
Proposed Oxygen Concentration Monitoring System of Food Packaging
Oxidation/Reduction Oxidation is the process whereby a reactant loses one or more electrons. Reduction is the process whereby a reactant gains one or more.
Stimuli-responsive hydrogels based on acrylic acid and acrylamide
Wearable Medical Devices Market Analysis to 2025 Company Name: Global Market Forecastes Tel: / Web:
Charlie Gasperoni, Christian Tooley, and Jeffrey M. Halpern
s Changes: Cite figures under EIS
INSTRUMENTASI INDUSTRI
Fundamentals of Electrochemistry
Instrumental Methods II
Diagrams and Graphs.
Chapter 10 Electrolytic Cells 10.7.
M.A.D. Sleeve Muscular Atrophy Detection
Detection of Beta Carotene and Lutein
Chapter 10 ELECTROLYTIC CELLS 10.7.
Biopotential electrodes
Sports Fitness Heart Rate.
Biopotential electrodes
Intellical Red-ROD technology
Inverse Phase Transition
TOPIC 6 ELECTROCHEMISTRY
The Role of Catalysis in Next Generation Direct Hydrocarbon Solid Oxide Fuel Cell Anodes Steven McIntosh, Department of Chemical Engineering, University.
Chapter 2-1 Wearable Bio and Chemical Sensors
Cyclic Voltammetry Dr. A. N. Paul Angelo Associate Professor,
Brussels, May 15, 2007 Ilkka Saarnio
Biomedical Electronics & Bioinstrumentation
Work Smarter, Not Harder
Application of Optical Heart Rate Monitoring
© 2016 Global Market Insights, Inc. USA. All Rights Reserved Temperature Sensor Market: Key Technologies and Trends.
12 Lead ECG Trainer Cali Roen, Laura Bagley, Tony Schuler, Amy Weaver
Electrochemical Impedance Spectroscopy Mr.Halavath Ramesh 16-MCH-001 Department of Chemistry Loyola College –Chennai. University of Madras.
Presentation transcript:

Wearable Chemical Sensors: Characterization of ECG Electrodes with Electrochemical Impedance Spectroscopy Jennifer Deignan1, Michael McBrearty2, Javier Monedero3, Shirley Coyle1, Donal O’Gorman3, Dermot Diamond1 1Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Ireland. 2adidas Wearable Sports Electronics, Chadds Ford, Pennsylvania, United States. 3School of Health and Human Performance, Dublin City University, Ireland. Introduction Wearable monitoring systems have become very popular in the health and sports industry in recent years, with comfort of the device becoming a high priority. However, it is important that accuracy does not suffer for the sake of comfort. Hospital monitoring electrodes are accurate in large part due to the reduction-oxidation reaction of Ag/AgCl. This work presents a testing method to compare future generations of heart rate monitoring devices to the current standard of disposable Ag/AgCl electrodes. Background Blocking and Non-blocking Electrodes R1 CPE L1 R1 CPE L1 R2 Textile electrodes are considered blocking electrodes as they display no charge transfer behavior that is seen in non-blocking electrodes. This can be seen in the above graph as the textile electrodes show no consistent trend in resistance with respect to temperature change while the resistance of the 3M electrodes decreases with increasing temperature. Standard Ag/AgCl disposable monitoring electrodes rely on the well known AgCl + e- ↔Ag + Cl- reduction-oxidation reaction to produce clear, reliable electrocardiogram (ECG) signals for inpatient monitoring. As these electrodes are unsuitable for athletic monitoring due to comfort, ease of use, and data capture, a range of heart rate monitoring straps have been developed. However, these straps are typically made of silver coated fabric or carbon black and lack the reduction-oxidation reaction which make Ag/AgCl electrodes so accurate. On-body Testing Without electrode gel on textile electrode Impedance Measurements (74 bpm) (40 bpm) 3M electrodes With electrode gel on textile electrode Textile electrodes 13°C 25°C 37°C 49°C 1°C (78 bpm) (74 bpm) 3M electrodes Resting ECG measurements were taken on a healthy adult male with both electrodes simultaneously. Without electrode gel, the textile electrodes showed erratic behavior, with sudden increases and decreases in heart rate that were not present with the 3M electrodes. Textile electrodes Conclusions Wearable sensors can provide continuous monitoring for health, sports and exercise. Heart rate monitors are integral to the creation of whole body monitoring systems. With small enhancements, the accuracy of textile based sensors can be dramatically improved and such whole body systems could be realized. 3M Red Dot 2230 diaphoretic monitoring electrodes were tested against an adidas textile strap. An impedance sweep from 1MHz to 1mHz was conducted on the samples at 1°C, 13°C, 25°C, 37°C and 49°C. The data was then modeled to the appropriate equivalent circuit for each sample. Acknowledgments Science foundation Ireland under the Insight initiative, grant SFI/12/RC/2289 and IRSES-GA-2010-269302.