HIGH TEMPERATURE WATER HEAT PUMP (NH3)

Slides:



Advertisements
Similar presentations
Energy-Efficient Process Cooling
Advertisements

1 Ann Van Lysebetten CO 2 cooling experience in the LHCb Vertex Locator Vertex 2007 Lake Placid 24/09/2007.
HVAC System Design PES Institute of Technology. Objective Goal: To develop an automotive air-conditioning system that is smaller and lighter than with.
Heat pumps and their economics. There has been fluctuations before Johnson Controls2.
Reduses – Ampèrestraat 19D – 3861 NC Nijkerk, NL – Tel – – Applied gas engine heatpumps Thermal energy solutions.
System and Component Efficiency with Refrigerant R410a A. T. Setiawan 1, A. Olsson 2, H. Hager 2 1 Department of Energy Technology, Div. Of Applied Thermodynamics.
EXERCISE 1 CHAPTER 11.
1 Vapour compression cycle Refrigerator Air conditioning plant Heat pump (“ ENERGY MANAGEMENT HANDBOOK” Sixth Edition, Chapter 8)
Contemporary Engineering Economics, 4 th edition, © 2007 Life-Cycle Cost Analysis Lecture No.22 Chapter 6 Contemporary Engineering Economics Copyright.
Sensors and Actuators John Errington MSc. Sensors and Actuators Sensors produce a signal in response to a change in their surroundings e.g. Thermostat.
Cogeneration.
ISAT Module III: Building Energy Efficiency
EGR 334 Thermodynamics Chapter 10:
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
Refrigeration Terms Cooling Load, Cooling Capacity – Q in Compressor Load – W in Condenser Load – Q out Tons of Refrigeration – Rate of Heat Input Refrigerant.
Perfect solution for large building
Introduction Topic: The Basic Ground Source Heat Pump Name: Matthew Stoangi Objective: To provide a clear understanding of the mechanics involved in the.
Chilled water Meyrin consolidation Study 1 st Part Many thanks for their contribution to: Pasquale Alemanno, Fortunato Candito, Alexander Putzu.
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
Settings & Adjustments. Settings & Adjustments.
District Heating Technology Improvement of district heating systems efficiency starts at the consumer New calculation tools help consumer and district.
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Directional Control Valve CV691. Present system New Proposed System with CV691 valve Directional Control Valve CV691 with integrated Flow Control Valve.
Hydraulic Kit (pump and tank) Pictures from prototype.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
NOVO ETS IMPROVING YOUR ORGANIZATIONS’ ENVIRONMENTAL, HEALTH AND SAFETY PERFORMANCE ENERGY MANAGEMENT IN THE CONTEXT OF GREEN PRODUCTIVITY.
July 26, 2014 Refrigeration Subcommittee Proposed Revision of Refrigeration Provisional Data Requirements.
/ 1 ERA A chiller to suit everyone. Air cooled water chillers Free-cooling chillers Air/water heat pumps.
Last Time Where did all these equations come from?
BCWC Water-cooled water chillers with centrifugal compressor/s
Lecture Objectives: Finish with absorption cooling Power generation Rankine cycles Connect power generation with heating and cooling –CHP –CCHP.
1 BREC Air-cooled water chillers BREF Air-cooled water chillers with free-cooling system 1602A A A A A 3202A A A -
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
1 ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 6 : PUMPS.
CENTRIFUGAL PUMPS:- DESIGN & PERFORMANCE Ir. N. Jayaseelan 2012.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
00 Heat pumps by Kenneth Hoffmann. Why NH 3 Heat pump? NH 3 Heat Pump sizes Case stories CO 2 Heat Pump NH 3 Heat Pump applications NH 3 Heat Pump sizes.
Singapore Save Energy, Save Money TM. Steam Boiler Poultry Scalding Water Tank Why heats up to 120 ℃? When you only need 60 ℃ Heating up to 120 ℃ to get.
1 Summer Training On Refrigeration and Air Conditioning From:-Amber Enterprises PVT.LTD.
Aleph Networks Co. Inefficient Operation Recognized by Commissioning and Case Example of Countermeasures Ritsumeikan Uji HighSchool.
CASE STUDY : Solar Powered air conditioning as a solution to reduce environmental pollution in Tunisia.
First Law of Thermodynamics applied to Flow processes
Continental AG Manufacturing Facility
DEMAND SIDE ENERGY OPTIMIZATION WITH
Date of download: 10/6/2017 Copyright © ASME. All rights reserved.
Components Pumps.
Saturation Temperature
Refrigeration & air conditioning
Refrigeration and Heat Pump Systems
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Heat Pumps For Energy Efficient / Economical Hot water Generation
Introduction to Food Engineering
Lecture Objectives: Continue with Sorption Cooling
Mohamed Iqbal Pallipurath
THE RECP ASSESSMENT Brent Goliath NATIONAL CLEANER PRODUCTION CENTRE
Variable Frequency Drive Savings Calculator Tools
HIGH PERFORMANCE PRESSURE SYSTEMS.
The Basic Direct Expansion Refrigeration Cycle
HIGH PERFORMANCE TEMPERATURE CONTROL.
Pumps and Lift Stations
Heat Pumps For Energy Efficient / Economical Hot water Generation
Refrigeration and Air conditioning
HOW TO SAVE MAXIMUM ENERGY IN YOUR COMPRESSORS INSTALLATION
Cryogenic System Commissioning Summary Report
“Improving The Energy Efficiency and Milk Quality with CO2 Refrigeration Systems with Heat Recovery on New Zealand Dairy Farms” Klaas Visser Principal.
Door Heat Exchanger: Specification
“THERMODYNAMIC AND HEAT TRANSFER”
Presentation transcript:

HIGH TEMPERATURE WATER HEAT PUMP (NH3) Industrial Cooling HIGH TEMPERATURE WATER HEAT PUMP (NH3) Project nº: 2014-209 MÉLIDA NAVARRA Start Up 23/12/2015

DESIGN TERMS FLOW H.T.W.H.P  20 m3/h INPUT  +14ºC OUTPUT + 65 ºC Heat Output 1.200 kW WATER CONSUMPTION: PRODUCTION PROCESSES CLEANING …/… High temperature WATER HEAT PUMP NH3 Indirect Flooded System Regime +29ºC + 68ºC

ISOFRED,S.L. PRESENTATION ABOUT HIGH TEMPERATURE WATER HEAT PUMPS WITH HIGH PREASSURE NH3 COMPRESSORS. * Visit attached Link *Presentation available in :http://www.atmo.org/media.presentation.php?id=788

Completely respectful with the environment REFRIGERANT SELECTED: R-717; NH3; AMMONIA NATURAL REFRIGERANT PART OF THE “NATURAL FIVE” CHARACTERISTICS: LEVEL OF SECURITY  L2B2 GLP (GLOBAL WARNING POWER)  0 ODP(OZONE DESTRUCTION POWER)  0 LOADING OF THE INSTALLATION  160 kg NH3 : Nitrogen and Hydrogen AMMONIA: NATURAL REFRIGERANT Completely respectful with the environment

Work Conditions and Output Condensation Flowrate: 23,9 m3/h The HP system is inserted as an alternative condenser in parallel with the existing installation. The accumulation is made in a tank of 100 m3 to compensate the hours of lack of production Work Conditions and Output Condensation Flowrate: 23,9 m3/h Consumption : 118 kW Heat Power: 1.329 kW COP:11,30 Input Temperature : 9,8 ºC Output Temperature : 57,6ºC Control SCADA view with refrigeration and hydraulic system layout

Work system capabilities designed Heat capacity : From 593 to 1.021 kW Absorbed Power: From 110 to 200,4 kW Motor Speed: From 750 to 1.300 rpm Heat COP : From 6,02 to 6,29 Flowrate : From11,65 to 20,34 m³/h OPERATIONAL LIMITS Maximum pressure discharge  60 bar Maximum differential pressure  40 bar Maximum discharge temperature  160 ºC Maximum water inlet 50ºC Compressor Block View

CONSUMPTIONS TABLE AND SAVING TO THE INSTALLATION <2 AÑOS HEAT PUMP Boiler Anual Cost Savings COP 6,02 0,90 Power Consumption kWh/day 3.328,5 kW/day 21.942 kW/day Anual Power Consumption (260 days) 865.410 kW/year 5.704.920 kW/year Energy rates 0,075 €/kWh 0,035 €/kWh Energy costs 64.906 € 199.672 € 134.766 € Emisiones CO2 tm 346 tm 1.006 tm CONSUMPTIONS TABLE AND SAVING TO THE INSTALLATION <2 AÑOS

Proportion Valve details, Scada Display , Three wat valves, Calorie counter.

Views of the machine room and PLC details to control and constant pressure station www.isofred.com