Hearty Welcome!.

Slides:



Advertisements
Similar presentations
22 March Controller Diagnostics. 22 March Topics Covered: Diagnostics that allows you to check basic controller and reader functionality through.
Advertisements

Wireless Remote Control & Touch Screen Modular Switches.
EMerge Browser Managed Security Platform Module 2 Hardware install.

Trouble - Shooting ELR - Electric Latch Retraction.
Enterprise Software Solution Lab Pvt Ltd
Samsung Techwin Access Control Sales Presentation 2010.
Introduction System Schematic ~ LON-FO NC EC200 LOOPS 2-4 FIBRE OPTIC
© red ©
Training.
WELCOME EVERYBODY!.
February 5, Inputs and Output Relays. February 5, What are Inputs and Output Relays? Inputs allow the controller to receive signals from the.
SF-3000 Installation Manual. 2 Back of SF CON400) USB connector - User can use USB memory stick after connect USB connector of key PCB. CON500)
ZIGBEE Network Introduction Integrated with Zigbee or Bluetooth products Operation voltage : DC 7V ~ 40V. RS232 Interface Meets or Exceeds TIA/EIA-232-F.
Vex 1.0 © 2005 Carnegie Mellon Robotics Academy Inc. Touch Sensor This lesson will explain how to hook a standard micro switch into the Vex system to function.
USER INTERFACE CONTROL MODULE S ECURE IT : Automated Laptop Security System University of Pennsylvania School of Engineering and Applied Science Electrical.
INTRUSION ALARM TECHNOLOGY
03 September 2007 Digital I/O Wiring Exercise. Copyright © 2007 Alien Technology Corporation. Advanced Academy Student use only. Not for redistribution.
Doc. Ver. : V1.10 Feb., R&D Center Union Community Co., Ltd. Doc. Ver. : V1.10 Feb., R&D Center Union Community Co., Ltd. Installation &
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul., Union Community Co., Ltd.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
CANBus Hardware Setup. CANBus CANBus is a control system method that can be used instead of the conventional PWM system. It uses RJ12 cable, which is.
Fault Tolerant Configuration
Training : M5+SAC844+Lock Dec,2014 by Sophy.
Februar 2014WaveNet Starter │ SEITE 1 WAVE NET RADIO NETWORK 3065 ACCESSORIES WN.LN.SENSOR.CABLE CHARACTERISTICS  Sensor cable is connected to the WN(M).LN.R/C.
Controlling an LED with a switch. 2 breadboard place where you can build electric circuits really quickly the magical breadboard.
Serial/Fiber-Converter - IE-MCT-1RS232/485-1SC/ST
Door Controller Device. 2 Door Controller Device (DCD) The DCD is the “Remote Brains” of the system. It is the controller device located at each access.
 Introduction  Problem  Solution  Future work.
R6 Marketing Guide Keypad and Proximity Access Controller Metal Shell, IP65&Vandal Resistant.
SIMPLE & MODULAR PC BASED DOOR ACCESS CONTROL v1.00
Aloha Observatory Design
Solar Energy Generator: Design Rendering Description
Blue Access Technologies
Quick Guide For sensors
COSEC ARC IP based Access Control Panel.
AUTOMATED security system
Right People in Right Place at Right Time
Hardware, Installation & maintenance
Environment Temperature Monitor
Site Controller Unit and Trunk Interface Unit
AS1 Series AREAscan™.
BO-A210N User Manual 1. Registration methods 2. Delete methods
AUTOMATED security system
Introduction to Handshaking Communication with SSC-32U
2N® Access Unit Bluetooth
2N® Access Unit Touch Keypad
Connections Topology of Apollo ACS.
Security Module, MDRC SCM/S 1.1
FEEDER PROTECTION UNIT
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
2N® Access Unit Touch Keypad
SW REV Position, DIFFERENCES ONLY SHOWN, L1 is the same
2N® Access Unit RFID (125kHz or 13.56MHz).
2N® Access Unit Bluetooth
Module 1 – Power Supply AMC APS-PBC-60
What Color is it?.
©
2N Access Unit 2.0 Multi-technology access control readers.
©
ACOE347 – Data Acquisition and Automation Systems
【Date: 】
Passive Infrared Sensor
Simulated Assembly Line and Processing Workstation
2N® Access Unit Bluetooth
Presentation transcript:

Hearty Welcome!

Standard Door Interfaces Standard doors: These doors are without display and touch sense keys There are two different variants in Standard Door CAS FOS Standard door can work as normal door as well as panel lite door With standard door user can connect different hardware interfaces like Door Lock, Exit Switch, Exit Reader, Sensor and Alarm

Standard Door in Direct Door Mode For standard door, user can connect different interfaces using different push back connector available at rear side of door Different dedicated connectors are provided for connections User can use CA/ FO exit reader for connection with main door There are two different modes for connection i.e. RS232 and Wiegand Rear Image of door

Standard Door with Exit Reader Interface If distance between Main Door and Exit Door is < 4.5 meter then use RS232 terminals for connection With FO reader only RS232 connection type is used Maximum 4.5 meter FO Reader CAS

Standard Door with Exit Reader Interface Rear Image of FO Reader Rear Image of CAS

Standard Door with Exit Reader Interface(RS232) Function Pin no. Rdr Power 34 GND 33 Green LED 16 Red LED 17 Beeper 18 COM 40 Tamper 30 RS232-TX 37 RS232-RX 38 Status LED 35 Alarm LED 36 Pin no. Function 1 Rdr Power 2 GND 3 Green LED 4 Red LED 5 Beeper 6 COM 7 Tamper 8 RS232-RX 9 RS232-TX 10 Status LED 11 Alarm LED CAS FO

Standard Door with Exit Reader Interface(RS232) If distance between Main Door and Exit Door is > 4.5 meter then use Wiegand terminals for connection With CA reader RS232/ Wiegand type connections can be used Maximum 150 meter CA Reader CAS

Standard Door with Exit Reader Interface(RS232) Function Pin no. Rdr Power 34 GND 33 RS232-RX 38 RS232-TX 37 Green LED 16 Red LED 17 Beeper 18 HOLD 19 COM 40 Tamper 20 Status LED 35 Alarm LED 36 Pin no. Function 1 Rdr Power 2 GND 13 RS232-TX 12 RS232-RX 6 Green LED 7 Red LED 8 Beeper 9 HOLD 10 COM 11 Tamper 14 Status LED 15 Alarm LED CAS CA

Standard Door with Exit Reader Interface (Wiegand) Function Pin no. Rdr Power 34 GND 33 DATA0 14 DATA1 15 DATA RTN 13 Green LED 16 Red LED 17 Beeper 18 HOLD 19 COM 40 Tamper 20 Status LED 35 Alarm LED 36 Pin no. Function 1 Rdr Power 2 GND 3 DATA0 4 DATA1 5 DATARTN 6 Green LED 7 Red LED 8 Beeper 9 HOLD 10 COM 11 Tamper 14 Status LED 15 Alarm LED CAS CA

Standard Door with Door Lock Interface Standard Door Controller provides interface with different Door Lock like EM Lock, Bolt Locks, Strike Locks…. A door lock with 12V @ 0.5 amp takes power from main device while for connection of higher voltage capacity lock external power supply is required Generally two types of Door locks are available: Fail Safe: This type of door locks are unlocked when power supply is removed Power supply is applied to lock the door 2. Fail Secure: This type of door locks are unlocked when power supply is applied Power supply is removed to lock the door

Fail Safe Connection type In relay terminal, NC and COM are always shorted internally To keep door lock in normally connected mode with door, connect +12V with COM and positive Lock terminal with NC and GND with 0V So door will open whenever power is removed from lock terminal - + Lock terminals in door Lock Magnet

Fail Secure Connection type In relay terminal NC and COM are always shorted internally To keep door lock in normally connected mode with door, connect +12V with COM and positive Lock terminal with NO and GND with 0V So door will open whenever power is applied to lock terminal + Lock terminals in door Lock Magnet

Standard Door with Door Lock Interface For door lock with higher voltage capacity (maximum 30V @ 1 amp), user needs to connect external power supply Fail safe lock connections: + Lock terminals in door Lock Magnet

Standard Door with Door Lock Interface For door lock with higher voltage capacity (maximum 30V @ 1 amp), user needs to connect external power supply Fail Secure lock connections: + Lock terminals in door Lock Magnet

Advance Door Lock connection To detect events like Door Force Open, Door held too long open etc.. door sense terminals(pin 11 and pin 12) needs to be connected with door lock status output along with 4.7 K resistor +

EXIT Switch connection with Standard Door In Exit Switch connection directly connect exit switch with specific ports available in door: Function Pin no. Exit SW terminal 31 COM 32

AUX IN connection with Standard Door In standard Door, using AUX IN port user can connect a sensor like Motion Detector, Fire Alarm, Smoke Detector etc.. Specific port is given with standard door to connect sensor with device NC COM NO Function Pin no. COM 10 AUX IN + 9 Connection terminals in door Relay terminals of Fire Alarm Panel

AUX OUT connection with Standard Door Relay terminals of Alarm To generate action according to the detected event, user can connect an alarm using AUX Output port Connect relay terminals of alarm with Aux Output port relay terminals Function Pin no. NC 26 COM 27 NO 28 NC COM NO Connection terminals in door Relay terminals of Alarm

Premium Door Interfaces Premium Door: This door is with display and touch sense keys FOP is a Premium Door Premium Door can work as normal door as well as panel lite door With Premium door user can connect different hardware interfaces like Door Lock, Exit Switch, Exit Reader, Sensor and Alarm

Premium Door in Direct Door Mode For premium door, user can connect different interfaces using different push back connector available at rear side of door Different dedicated connections are provided for connections User can use CA/ FO exit reader for connection with main door There are two different modes for connection i.e. RS232 and Wiegand Rear Image of door

Premium Door with Exit Reader Interface Rear Image of FO Reader Rear Image of CAS

Premium Door with Exit Reader Interface If distance between Main Door and Exit Door is < 4.5 meter then use RS232 terminals for connection With FO reader only RS232 connection type is used Maximum 4.5 meter FO Reader FOP

Premium Door with Exit Reader Interface(RS232) Function c Pin no. Rdr Power 4 GND 5 Green LED 9 Red LED 10 Beeper 11 COM 13 NC/NO 14 RS232-RX 15 RS232-TX 16 Status LED 17 Alarm LED 18 Pin no. Function 1 Rdr Power 2 GND 3 Green LED 4 Red LED 5 Beeper 6 COM 7 Tamper 8 RS232-RX 9 RS232-TX 10 Status LED 11 Alarm LED FOP FO

Premium Door with Exit Reader Interface(RS232) If distance between Main Door and Exit Door is > 4.5 meter then use Wiegand terminals for connection With CA reader RS232/ Wiegand type connections are used Maximum 150 meter CAS CA Reader FOP

Premium Door with Exit Reader Interface(RS232) Function (Device) Pin no. Rdr Power 4 GND 5 Green LED 9 Red LED 10 Beeper 11 HOLD 12 COM 13 NC/NO 14 RS232-RX 15 RS232-TX 16 Status LED 17 Alarm LED 18 Pin no. (Reader) Function 1 Rdr Power 2 GND 6 Green LED 7 Red LED 8 Beeper 9 HOLD 10 COM 11 Tamper 13 RS232-TX 12 RS232-RX 14 Stats LED 15 Alarm LED FOP CA

Premium Door with Exit Reader Interface(Wiegand) Function (Device) Pin no. Rdr Power 4 GND 5 DATA0 6 DATA1 7 DATA RTN 8 Green LED 9 Red LED 10 Beeper 11 HOLD 12 COM 13 Tamper 14 Status LED 17 Alarm LED 18 Pin no. (Reader) Function 1 Rdr Power 2 GND 3 DATA0 4 DATA1 5 DATARTN 6 Green LED 7 Red LED 8 Beeper 9 HOLD 10 COM 11 Tamper 14 Status LED 15 Alarm LED FOP CA

Premium Door with Door Lock Interface Premium Door Controller provides interface with different Door Lock like EM Lock, Bolt Locks, Strike Locks…. A door lock with 12V @ 0.5 amp takes power from main device while for connection of higher voltage capacity lock external power supply is required Generally two types of Door locks are available: Fail Safe: This type of door locks are unlocked when power supply is removed Power supply is applied to lock the door 2. Fail Secure: This type of door locks are unlocked when power supply is applied Power supply is removed to lock the door

Fail Safe Connection type In relay terminal, NC and COM are always shorted internally To keep door lock in normally connected mode with door, connect +12V with COM and positive Lock terminal with NC and GND with 0V So door will open whenever power is removed from lock terminal Lock terminals in door Lock Magnet

Fail Secure Connection type In relay terminal NC and COM are always shorted internally To keep door lock with normally connected mode with door, connect +12V with COM and positive Lock terminal with NO and GND with 0V So door will open whenever power is applied to lock terminal Lock terminals in door Lock Magnet

Premium Door with Door Lock Interface For door lock with higher voltage capacity (maximum 30V @ 1 amp), user needs to connect external power supply Fail safe lock connections: Lock terminals in door Lock Magnet

Premium Door with Door Lock Interface For door lock with higher voltage capacity (maximum 30V @ 1 amp), user needs to connect external power supply Fail Secure lock connections: Lock terminals in door Lock Magnet

Advance Door Lock connection To detect events like Door Force Open, Door held too long open etc.. door sense terminals(pin 11 and pin 12) needs to be connected with door lock status output along with 4.7 K resistor

EXIT Switch connection with Premium Door In Exit Switch connection directly connect exit switch with specific ports available in door: Function Pin no. Exit SW terminal 19 COM 20

AUX IN connection with Premium Door User can connect a sensor like Motion Detector, Fire Alarm, Smoke Detector etc. with premium door using AUX IN port Specific port is given with premium door to connect sensor with device NC COM NO Function Pin no. AUX IN + 31 COM 32 Connection terminals in door Relay terminals of Fire Alarm Panel

AUX OUT connection with Premium Door Relay terminals of Alarm To generate action according to the detected event, user can connect an alarm using AUX Output port Connect relay terminals of alarm with Aux output port relay terminals Function Pin no. NC 2 COM 1 NO 3 NC COM NO Connection terminals in door Relay terminals of Alarm

PATH Door Interfaces PATH Door Controllers are of two types: DCCX and DCFX DCFX includes three different variants: DCFE DCCM DCCI DCFP DCCX includes three different variants: DCCE DCCP User can connect different hardware interfaces like Door Lock, Exit Switch, Exit Reader, Sensor and Alarm with PATH Door controller

PATH Controller with Exit Reader Interface User can connect different interfaces using different connector available at rear side of door Different dedicated connections are provided in PATH controller User can use RDFX/RDCX exit reader for connection with main DCFX/DCCX door Rear Image of door

PATH Controller with PATH Reader Interface To connect PATH Reader with PATH Controller CN2 terminal is used CN2 terminal includes different connectors within it User needs to connect main door 15 pin connector with Exit Reader 15 pin connector directly All connectors are provided with device In PATH series, user can connect PATH Controller with PATH Reader through RS232/Wiegand For RS232 connection user has to connect PATH controller and PATH Reader through RS232-RX and RS232-TX For Wiegand connection user has to connect PATH controller and PATH Reader through DATA0 and DATA1 connection

PATH Controller with Exit Reader Interface Connect PATH Reader 15 pin connector with PATH Door 15 pin connector

PATH Controller with Exit Reader Interface(RS232) CN2 GND Black Red 12V_RDR Red LED Brown Orange GREEN LED Alarm Violet Light Brown STATUS HOLD Blue Yellow BEEPER GND Black Light Blue TAMPER_NC/NO RS232_TX Gray Pink RS232_RX Black GND CN2 GND Black Red 12V_RDR Red LED Brown Orange GREEN LED Alarm Violet Light Brown STATUS HOLD Blue Yellow BEEPER GND Black Light Blue TAMPER_NC/NO RS232_TX Gray Pink RS232_RX Black GND

PATH Controller with Exit Reader Interface(Wiegand) CN2 GND Black Red 12V_RDR Red LED Brown Orange GREEN LED Alarm Violet Light Brown STATUS HOLD Blue Yellow BEEPER WDATA1 White Green WDATA0 GND Black Light Blue TAMPER_NC/NO Black GND CN2 GND Black Red 12V_RDR Red LED Brown Orange GREEN LED Alarm Violet Light Brown STATUS HOLD Blue Yellow BEEPER WDATA1 White Green WDATA0 GND Black Light Blue TAMPER_NC/NO Black GND

PATH Controller with Exit Reader Interface Connect PATH Reader 15 pin connector with PATH Door 15 pin connector

PATH Door with Door Lock Interface PATH Door Controller provides interface with different Door Lock like EM Lock, Bolt Locks, Strike Locks…. A door lock with 12V @ 0.5 amp takes power from main device while for connection of higher voltage capacity lock external power supply is required Generally there are two types of Door locks available: Fail Safe: This type of door locks are unlocked when power supply is removed Power supply is applied to lock the door 2. Fail Secure: This type of door locks are unlocked when power supply is applied Power supply is removed to lock the door

Fail Safe Connection type In relay terminal, NC and COM are always shorted internally To keep door lock in normally connected mode with door, connect +12V with COM and positive Lock terminal with NC and GND with 0V in CN1 terminal So door will open whenever power is removed from lock terminal

Fail Safe Connection type In CN1 10 pin connector is available to connect with door lock terminals GND NC

Fail Secure Connection type In relay terminal NC and COM are always shorted internally To keep door lock with normally connected mode with door, connect +12V with COM and positive Lock terminal with NO and GND with 0V in CN1 terminal So door will open whenever power is applied to lock terminal

Fail Secure Connection type In CN1 10 pin connector is available to connect with door lock terminals GND NO

PATH Controller with Door Lock Interface For door lock with higher voltage capacity (maximum 30V @ 1 amp), user needs to connect external power supply Fail safe lock connections: 24 V, 1 A NC - + COM

PATH Controller with Door Lock Interface For door lock with higher voltage capacity (maximum 30V @ 1 amp), user needs to connect external power supply Fail Secure lock connections: 24 V, 1 A - + NO COM

EXIT Switch connection with PATH Controller To connect exit Switch dedicated 5 pin connector is provide in CN2 terminal

Direct Door with PATH Reader connections FOP DOOR PATH Reader

Direct Door with PATH Reader connection Diagram Rear Image of FOP Rear Image of COSEC PATH Reader

Direct Door with PATH Reader connections Functions Pin no. Rdr Power RED 4 GND Black 5 Green LED Orange 9 Red LED Brown 10 Beeper Yellow 11 COM Black 13 NC/NO Light Blue 14 RS232-RX Pink 15 RS232-TX Gray 16 Status LED Light Brown 17 Alarm LED Violet 18 CN2 Red 12V_RDR Black GND Orange GREEN LED Brown Red LED Yellow Beeper GND Black Light Blue TAMPER_NC/NO Pink RS232_RX RS232_TX Gray Light Brown STATUS Alarm Violet

Wireless Door Interfaces Wireless Door: These door provides wired as well as wireless connectivity We have three Wireless door: FOW( Finger Optic Wireless) PVR (Palm Vein Reader) NGT (Next Generation Terminal) Wireless Door can work as only normal door With Wireless door user can connect different hardware interfaces like Door Lock, Exit Switch, Exit Reader, Sensor and Alarm FOW PVR

Wireless Door in Direct Door Mode For Wireless door, user can connect different interfaces using different connector available at rear side of the door Different dedicated connections are provided for connections User can use CA/ FO exit reader for connection with Wireless door There are two different mode for connection i.e. RS232 and Wiegand Rear Image of door

Wireless Door with Exit Reader Interface Dedicated connections are provided for exit reader in C2 terminal Rear Image of FO Reader Rear Image of CAS

Wireless Door with Exit Reader Interface If the distance between main Door and Exit Door is < 4.5 meter then use RS232 terminals for connection With FO reader only RS232 connection type is used Maximum 4.5 meter FO Reader FOP

Wireless Door with Exit Reader Interface(RS232) Function C2 Pin no. Rdr Power 15 GND 14 Green LED 10 Red LED 9 Beeper 8 COM 6 NC/NO 5 RS232-RX 4 RS232-TX 3 Status LED 2 Alarm LED 1 Pin no. Function 1 Rdr Power 2 GND 3 Green LED 4 Red LED 5 Beeper 6 COM 7 Tamper 8 RS232-RX 9 RS232-TX 10 Status LED 11 Alarm LED

Wireless Door with Exit Reader Interface(RS232) If distance between main Door and Exit Door is > 4.5 meter then use Wiegand terminals for connection With CA reader RS232/ Wiegand type connections are used Maximum 150 meter CAS CA Reader

Wireless Door with Exit Reader Interface(RS232) Function C2 Pin no. Rdr Power 15 GND 14 Green LED 10 Red LED 9 Beeper 8 HOLD 7 COM 6 NC/NO 5 RS232-RX 4 RS232-TX 3 Status LED 2 Alarm LED 1 Pin no. Function 1 Rdr Power 2 GND 6 Green LED 7 Red LED 8 Beeper 9 HOLD 10 COM 11 Tamper 13 RS232-TX 12 RS232-RX 14 Stats LED 15 Alarm LED

Wireless Door with Exit Reader Interface(Wiegand) Function C2 Pin no. Rdr Power 15 GND 14 DATA0 13 DATA1 12 DATA RTN 11 Green LED 10 Red LED 9 Beeper 8 HOLD 7 COM 6 Tamper 5 Status LED 2 Alarm LED 1 Pin no. Function 1 Rdr Power 2 GND 3 DATA0 4 DATA1 5 DATARTN 6 Green LED 7 Red LED 8 Beeper 9 HOLD 10 COM 11 Tamper 14 Status LED 15 Alarm LED

Wireless Door with Door Lock Interface Wireless Door Controller provides interface with different Door Lock like EM Lock, Bolt Locks, Strike Locks…. A door lock with 12V @ 0.5 amp takes power from main device while for connection of higher voltage capacity lock external power supply is required Generally there are two types of Door locks available: Fail Safe: This type of door locks are unlocked when power supply is removed Power supply is applied to lock the door 2. Fail Secure: This type of door locks are unlocked when power supply is applied Power supply is removed to lock the door

Fail Safe Connection type In relay terminal, NC and COM are always shorted internally To keep door lock in normally connected mode with door, connect +12V with COM and positive Lock terminal with NC and GND with 0V So door will open whenever power is removed from lock terminal Specific Door lock connections are given in C5 terminal Lock terminals in door Lock Magnet

Fail Secure Connection type In relay terminal NC and COM are always shorted internally To keep door lock with normally connected mode with door, connect +12V with COM and positive Lock terminal with NO and GND with 0V So door will open whenever power is applied to lock terminal Lock terminals in door Lock Magnet

Wireless Door with Door Lock Interface For door lock with higher voltage capacity (maximum 30V @ 1 amp), user needs to connect external power supply Fail safe lock connections: Lock terminals in door Lock Magnet

Wireless Door with Door Lock Interface For door lock with higher voltage capacity (maximum 30V @ 1 amp), user needs to connect external power supply Fail Secure lock connections: Lock terminals in door Lock Magnet

Advance Door Lock connection To detect events like Door Force Open, Door held too long open etc.. door sense terminal needs to be connected with door lock status output terminals in C5 along with 4.7 K resistor

EXIT Switch connection with Wireless Door In Exit Switch connection directly connect exit switch with specific ports available in door: Dedicated terminal C3 is given for exit switch connection Function CN3 Pin no. Exit SW terminal 1 COM 2

AUX IN connection with Wireless Door User can connect a sensor like Motion Detector, Fire Alarm, Smoke Detector etc. with Wireless door using AUX IN port In Wireless door specific terminal C4 is given to connect sensor with device NC COM NO Function CN4 Pin no. AUX IN + 5 COM 6 Connection terminals in door Relay terminals of Fire Alarm Panel

AUX OUT connection with Wireless Door Relay terminals of Alarm To generate action according to the detected event, user can connect an alarm using AUX Output port available in C4 terminal Connect relay terminals of alarm with Aux output port relay terminals Function Pin no. NC 2 COM 1 NO 3 NC COM NO Connection terminals in door Relay terminals of Alarm

Door connections with Panel Lite Panel Lite is master controller which controls up to 75 doors Standard Door, Premium Door and Path Controllers can be connected with panel lite so, all these doors works as panel door There are two different ways to connect any door with panel lite Ethernet Connectivity Rs485 Connectivity

Panel Lite Door connection In Direct door mode, according to events and actions device controls all hardware functions In panel lite door mode, panel lite controls all connected hardware Panel lite door communicates only with panel lite and panel lite communicates with Server

Ethernet Connectivity DOOR Lock C Controller Network Switch MATRIX Panel Lite Single DOOR Architecture Exit Switch L COSEC Server

Ethernet Connectivity DOOR Controller Network Switch Ethernet Connectivity COSEC PANEL Multi DOOR Architecture COSEC Server

RS485 Connectivity Loop-In Loop-In Loop-In Loop -Out Loop -Out Termination Resistor Loop -Out COSEC Server