System Important Points for Wiring Device1 Device2 Device3 DeviceN 1 2 3 4 " Hand-in-Hand" Connection Device1 Device3 Device2 1 2 3 4 " Star "Connection It is not good for using the " Star "Connection way. We suggest you to connect the products hand in hand, one by one.
System Important Points for Wiring Programming Module Power Supply Dimming Module Relay Module Note: Maximum 64 Device in one Subnet。 Maximum Distance for each subnet is 1200 meters。 BUS cable can not be stay together with the electricity cable . If need Parallel cabling way, please make sure that it has 50CM for those 2 types cables.
System Important Points for Wiring Typical Installation
Simple System Schematic 10/100M Ethernet Data Switch ~AC220V Other Sunbet BUS Power Supply Module Programming Module/Converter Dimming Module Relay Module LUX Detect Sensor Infrared Motion Sensor LCD Panel 6-Gang Switch PC RS485
System Maximum Capacity 255*255= 65025 Subnet ID:0 0-1 0-2 … 0-64 Subnet ID:0 0-65 0-66 … 0-254 System Maximum Capacity 255*255= 65025 Subnet ID:254 254-1 254-2 … 254-64 Subnet ID:254 254-65 254-66 … 254-254
Solution of Multiple Power system connection
dimmer introduction ◆6ch 2A dimmer ( SB-DN-D0602 ) Small dimmer(Din rail mount) ◆6ch 2A dimmer ( SB-DN-D0602 ) ◆4ch 3A dimmer ( SB-DN-D0403 ) ◆2ch 6A dimmer ( SB-DN-D0206 ) ,
Dimmer introduction Load type: AC220V, Resistive load incandescent lamp halogen lamp Led (with driver) … Attention: electricity-saving lamp & fluorescent light can’t be dim by this type of dimmer.
Programming of Dimmer (SB-DN-D0403)
Subnet ID and device ID Can remark accordingly in order to convenient in maintenance and management. Device MAC (physical)address Basical information
Control DC Maximum current :100mA SB-DN-6B0-10V Ballast Dimmer Wiring diagram L 6 relay switch 16A ballast N 6 channel direct output switches Module ID setting button S-BUS DC0-10V dimming voltage Control DC Maximum current :100mA
The Relay Module ◆SB-DN-R0810 Relay module ◆SB-DN-R0410 Relay module
HVAC Wiring diagram 5 channel output (5A relay) HVAC is a module specially for Air Conditioner controlling. Coordinate with DLP, it can completely and smartly run an Air Conditioner. switch 1,2,3 Speed: High/Medium/Low Mode: Cooling / Heating /Dehumidifier 485总线
HVAC Settings Delay time setting 1-10V Fan speed control voltage setting
HVAC Settings AC running test: select AC mode and FAN speed, click ‘Test’ , The HVAC module will run as settings.
DLP LCD PANEL Programming Intelligent control terminal-DLP panel Programming Front DLP LCD PANEL Programming
INTERFACE FUNCTION DLP Device subnet ID and device ID Can make remark according to actual location, convenience for maintenance and management Set the backlight, Higher value make the Great Lightness, And vice versa DLP INTERFACE FUNCTION
Combination way 1 1 2 3 2 4 Picture A example:In picture A selected the third (3) combination way . see Picture B key one and key two combined into one key. Then press key one or key two , the effect would be same as press key one . In picture B , key 3 and key 4 is combined as one key, then press key three or key four , the effect would be same as press key three . In other combination way , Blue part is combine together and set the first key, the white part is independence to control
RS485 MS04 Sensor Input wiring. Sensor input module is used to obtain any external incoming "on / off" signal , to achieve the purpose of external on/off signals controls Smart-Bus. For example if you want to control Smart-Bus via universal 4-way switch, you can use this module to collect On/Off information for each button of the switch, then setup the module. Sensor Input IN1 IN2 IN3 IN4 COM
目录 8 in 1 Sensor ◆8 in 1 Sensor Unique Features ●1 Built in PIR motion sensor ●1 Lux sensor ●2 Dry contacts input ●2 Extemal condition input ●IR(infrared) receiver ●IR(infrared) transmitter ●Built in security alarm logic (work with Security Module) ●Built in 32 Logics
8. Align the Remoter with 8 in 1 sensor, press the key and test IR Code receiving
The using of Infrared Code Learner 1、Connect the Infrared Code Learner with PC via USB port, then install the driver according to the system prompts.
3、Select “Learning mode” 4、Click “Ready for learning the code”,then it is ready to learn the code
红外学习器的使用 5, Put the transmitting terminal of the remote control to the receiving terminal of the Infrared Code Learner, press the button on the remote control, learn it from the following step.
6、按下遥控器按键后,当系统提示“学码成功”即说明该键学习完毕。点击显示已学码,确认有码学入。 红外传感器
7、Put the Infrared Code Learner facing to the device
Module address setting button Advanced Security Controller Interface of security module ( SB-DN-SEC250K ) Module address setting button S -BUS
Advanced Security Controller Introduction work with switches, Sensors, SMS module, Touch screen , the security module can: 1. Accecpt Arm/Disarm commands 2. Received sensor trigger 3. Process data 4. Send out commands by IR sensor/Universal to realize its fire protection, security, alarm functions. Security Module PIR sensor Z-Audio SMS Module Dry Contact Air Quality sensor Relay Dimmer LCD wall Panel
Advanced Security Controller 8in1 sensor(SB-CMS-8in1) security setting Security ID, area, mode setting
Advanced Security Controller security setting in ms04(SB-DRY-4Z)
Advanced Security Controller Configure keys for security Arm/Disarm in SB-DLP We can press the keys to arm/disarm.
Features SD card music playing Internal FM Radio External audio input FTP music playing
Connection diagrams
Step1: find your Z-Audio from S-BUS Programming Step1: find your Z-Audio from S-BUS A SD-card (format by FAT32) is needed to insert into the Z-Audio before power on.
Show Controller——DMX Module Configuration of Show Control ler (DMX Module) Show Controller——DMX Module 48 Channel——SB-DN-48DMX 240 Channel——SB-DN-240DMX 512 Channel——SB-DN-512DMX
System Diagram Configuration of Show Control ler (DMX Module) Ethernet cable Ethernet switch 512 channel DMX controller DMX512 cable Other effect lights Computer lighting Moving heads Moving heads System Diagram