Enabling Wireless M2M – IoT

Slides:



Advertisements
Similar presentations
Integrating Opengear console servers into Zenoss monitoring.
Advertisements

Integrating Opengear console servers into SolarWinds Orion NPM
Agenda Product Overview Hardware Interfaces Software Features
1 GE Consumer & Industrial Multilin MultiLink Hardened Ethernet Communication Switches Ethernet Communication Solutions for the Industrial Automation,
12-Port IP Power Manager IPM  Product Overview  Product Features  Applications  Comparison Presentation Outline 2 / 15.
OVERVIEW TBOX The best of 3 worlds.... TBOX The best of 3 worlds...  best of Automation  best of Internet  best of Telemetry.
4Gon Tel: +44 (0) Fax: +44 (0) G/3G ROUTERS GWR series Sergej Stolić, M.Sc.Geneko.
ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway
ADAM-5000/TCP- Distributed Ethernet I/O
An Introduction to SCADA Fundamentals and Implementation
1 © Red Lion Controls Inc. Introducing the RAM 9000.
IRRInet & ICC System Concept
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
Dual WAN Router Brand & Marketing MGMT Dept DrayTek Corp Vigor2912 Series 14 th Jan Based on f/w RC4.
Access Network Devices Remotely— Even if the Network is Down— with Out-of-Band Management.
Industrial Security Router LAN/WAN-Router (IE-SR-2GT-LAN) LAN/UMTS/3G-Router (IE-SR-2GT-UMTS-3G)
Model: DS-600 5x 10/100/1000Mbps Ethernet Port Centralized WLAN management and Access Point Discovery Manages up to 50 APs with access setting control.
BYTTON DS 3G Router for enterprise applications. TOPEX Bytton DS is a professional solution offering high speed and secure mobile access to Internet,
SCADA Supervisory Control And Data Acquisition Pantech Solutions Here is the key to learn more.
October 2010 SmartAXIS Controller. High Performance, Compact and Economical.
Advanced Datalogger: Z-GPRS3. # 4 Digital Input PNP, NPN bit max 30 Hz) RAM and Flash RAM 256 KB 1 MB + 8 MB (log) SD card max 32 GB.
Artificial Intelligence In Power System Author Doshi Pratik H.Darakh Bharat P.
AMIT Wireless Connectivity Solution
Wireless Modbus Series IOG761AM-0TDA1 Modbus Cellular Gateway
Enabling Wireless M2M – IoT
MDC-700 Series Modbus Data Concentrator [2016,05,26]
Fundamentals and Implementation
Enabling Wireless M2M - IoT
Mobile equipment for vacuum control
Sustainability Center Data Collection
AMIT Product Roadmap – Wireless M2M-IoT: I & V & O & U Series
In-Vehicle Series VHG760AM-0T001 In-Vehicle Hotspot GW
Poseidon 4002 Rack monitoring.
DUT Internet- Server AMIT-Test-Remote IPS Attacker Server AMIT-Test-CO
Wireless Modbus Series IOG761AM-0T001 Modbus Cellular Gateway
Mobility & Wireless - Routers, APs
In-Vehicle Series VHG87BAM-0T001 In-Vehicle Hotspot GW
Enabling Wireless M2M – IoT
Case Study: Real Life Unified Architecture Value
Product Introduction --QoS VPN Router G3 16/12/2015 Business WLAN
Broadband Communication Solution
IP-based 8-port Switched Power Manager
300Mbps n Wireless In-wall Access Point
Maintain, Manage And Monitor Outdoor Systems Remotely
Smart Retail Digital Store.
Wireless M2M Series IDG500AM-0T001 M2M Cellular Gateway
Wireless M2M Series IDG700AM-0T001 M2M Cellular Gateway
1+1 Ethernet Failover & Network Protection Switches
Industrial 1-port RS422/485 Modbus Gateway
Broadband Communication Solution
Wireless IP products: GWN series
Universal connection and monitoring for M2M applications
One-Stop Solution for Device Networking
Industrial Ethernet Solution
DT80 range Modbus capability
Fundamentals and Implementation
How SCADA Systems Work?.
Broadband Communication Solution
Network Peripheral.
An Introduction to SCADA Fundamentals and Implementation
Broadband Communication Solution
Network Peripheral.
ICP DAS Power Monitor and Management Solution 2016,03,28
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
Always Connected introduces Tigo SMART 3.1 This guide is interactive!
Substation Automation System
Ethernet Gateway EGX200 - EGX400
Integrated gateway-server
DIS-200G Series Sales Guide ESPD, July 2017 V1.1.
Presentation transcript:

Enabling Wireless M2M – IoT AMIT Wireless M2M-IoT Solution Scenario SCADA, Telemetry, Teleservice Table of Content Requirement & Goal Solution Scenario Solution & Benefits Description Product Selection Guide Product Specification Summary Feature Description Test test -1-

Goal & Requirement: SCADA, Telemetry & Teleservice Why SCADA, Telemetry & Teleservice? M2M-IoT application to do remote data collecting, control, measuring, maintain, monitoring, diagnostics and configuration all from operation center. Management from remote operation center, no need on-site resource , benefit from time and cost saving Action instantly anywhere from supervisor to meet mission critical application real time requirement Collecting data remotely within time period to do big data analysis for intelligent decision making When & Where to Use SCADA, Telemetry & Teleservice ? SCADA for Smart Industry in process control, factory automation, agriculture green house, and mining system Telemetry for Smart Utility in power distribution, meter reading, tank measurement and HVAC control Environment telemetry for Smart City in parameter monitoring, data collecting, traffic control, disaster alert AMIT Goal to build network for SCADA, Telemetry, Teleservice To build cellular based Modbus GW with full protocol, and signal I/O module for all SCADA application To build Wi-Fi point to multi-point connection between local base station and Modbus access devices TO build GW with outlet management for network PDU to restart power for device failure or regular ON/Off To build multi-site connectivity within VPN intranet tunnel between working server and all remote sites

Wireless Modbus Products Overview Wireless Modbus Series Application: Provide Modbus devices uplink to local control network or to intranet wirelessly in industrial automation application like SCADA, Telemetry and Tele-service. Cellular Gateway provide Modbus devices uplink to intranet by LTE or to local control network by Wi-Fi or Ethernet. AP Router provide devices uplink to control network by Wi-Fi. Ethernet Gateway provide devices uplink to control network by Ethernet. WAN & Uplink: LTE directly uplink to WAN intranet, Wi-Fi uplink to local center BSU. Multi-cellular, combo cellular, concurrent Wi-Fi provide high reliability and BW by fail- over and load balance mechanism. Modbus Connectivity & I/O Control: Ethernet provide network connectivity and Modbus TCP access. RS485 provide complete Modbus RTU/ASCII master / slave access. Wi-Fi AP provide Modbus bridge and Wi-Fi client access. D/A I/O module can be used for event trigger handling or data acquisition from environment sensors; RS232 provide virtual COM from remote. Networking: Fully protocol with NAT/Routing/IPv6 compatible with most IP network. Firewall and access control can prevent network from attacks. VPN tunneling enable secure intranet QoS provide privileged and quality access. Management: Web UI and CLI for friendly setting; SMS command for device remote control. SNMP and TR069 for device and network status management. Power / Housing: DC 9~48V dual power input with terminal block, flexible fitting with environment. IP30 Rugged metal case with DIN-Rail and mounting kit, used in various places. IOG : Modbus Cellular Gateway IOE : Modbus Ethernet Gateway IOP : Modbus AP Router 4

Solution Scenario: SCADA & Telemetry WAN & Uplink AMIT Product Local Connectivity Connected Device Application Internet @ NOC SCADA/OPC IWG Modbus Cellular GW IOG OOG Alarm Sensor Speaker Cloud ACS UDR VPN Concentrator HVAC Field Machine UCE SCADA/ Telemetry UTM DB AAA Multi-Site Connectivity ISP1 VPN GW with Wi-Fi AP ISP2 Wi-Fi2.4G VPN Intranet IP -CAM ODG/ODP IDG/IDP DSLAM xDSL Wi-Fi BSU 5G AP Max 2km IOP/IWP Modbus AP-Router OOP Wi-Fi SU 5G Uplink

Function Summary for Telemetry & SCADA – IOG/IWG Series WiFi Uplink IEC 60870-5 FRTU / IED FTU IP Cam VLAN 1 Sensor Modbus RTU PLC-1 HVAC Modbus TCP VLAN 2 Ethernet IOP SSID2 Modbus /RTU Local Management SSID 1 Option Connected Device Administration Data Center Remote Modbus Master Network Protocol Grouping VPN Intranet VPN Intranet Firewall Security Wi-Fi AP 2.4/5G Multi-WAN & Uplink IOG /IWG Series IEC70870-5 Interchange Field Communication Event Handling

Product Selection – Wireless Modbus Cellular Gateway MM31 In-Cabinet, DIN-Rail IP30,-20~60 8~48V TB, SMA Ant 187*110*31 mm Desk top Bracket DC12V, SMA Ant 94*70*27 mm PM02 SM01 130*99*31 mm Housing Spec. Modbus Cellular GW IOG700-0T(P)CR1 Uplink: (SM01) 1*LTE(3G),2*SIM Modbus TCP:1*RJ45 FE, RTU:1*RS485 D/A IO:1*DI + 1*DO Data Logging: 1*Micro-SD IOG500-0P001 Uplink: (PM02) 1*3G,2*SIM IOG761-0T001 Uplink: (MM31) 1*LTE(3G),2*SIM, 1*RJ45 FE Modbus TCP:3*RJ45 FE, RTU:1*RS485 11N Wi-Fi AP D/A IO:1*DI+1*DO IOG761-0TDA1 Uplink: (MM31) 1*LTE,2*SIM, 1*ADSL2+ Modbus TCP:4*RJ45 FE, RTU:1*RS485 11N Wi-Fi AP D/A IO:1*DI+1*DO ADSL+ Cellular Compact Basic Wi-Fi PoE Modbus GW IWG854-LTGT1 Uplink (MM41) 2*LTE(2*SIM) PoE & Networking 1+4*RJ45 PoE GE 1*RS485 802.3at PSE 120W 1*LTE(2*SIM) 1* RS485 Wi-Fi 11ac /11N IWG874-0T001 PoE Basic Dual Cellular In-Cabinet, DIN-Rail IP30,-30~70°C 24~56V TB; SMA Ant 62*125*160mm MM41

Feature Description : Modbus Control Network Control Center Modbus Function & Application Intelligent Protocol Conversion Data Storage and Recovery Smart Event Handler & Notification AAA UTM UCE852AM DB SCADA/OPC VPN Concentrator Cloud ACS Modbus TCP VPN Intranet LTE / Ethernet / ADSL Industrial Wireless Modbus Series LAN / WLAN Modbus TCP MicroSD card Data Logging File Saving… Proxy Mode Operation & Business Network Modbus RTU/ASCII RS-232 / RS-485 FTP service for remote downloading… Application Excellent capability to fulfill local and remote Modbus data accessing requirement in industrial automation field for SCADA, Telemetry and Tele-service. Benefits Intelligent Protocol Conversion : Performs a conversion between different protocols/interfaces of Modbus/TCP and Modbus/RTU/ASCII for the real-time monitoring and control and data acquisition from remote management sites. Data Storage and Recovery : Through the Data Logging feature to save the Modbus device real-time data onto internal/external storage space, and those files can be downloaded by FTP or Web UI, for Admin's further/fully/historical data analysis and statistics. Smart Event Handler & Notification : By monitoring the Modbus device values changing to send out the notification or alert via SMS, SNMP, and Email. 8

support Data Logging Function Feature Description : Data Logging Intranet & Internet AMIT Product Access Devices IOG Modbus Gateway support Data Logging Function ID=1 ID=2 ID=3 Modbus/RTU Slave devices Remote Data Control Center ACS Server Remote Gateway SCADA Server (Modbus TCP Master) HMI Host Data Base Sensor Alarm Wireless Modbus/TCP Slave devices Modbus TCP Data Acquisition Modbus/TCP Slave devices Multi I/O HVAC PLC USB Stick (external) MicroSD (internal/external) Serial Cable Ethernet Cable Wireless Feature & Modes 1. Sniffer Mode 2. Offline Proxy Mode 3. Full-Time Proxy Mode 4. Mode 1+2 Mixed 5. Mode 1+3 Mixed Log Files Management 1. Download via WEB UI 2. Download via FTP 3. Auto Upload via FTP by schedule 9

Multi-WAN Reliability Cellular Connectivity Rain Gauge Monitor Project Wireless Modbus SCADA / Telemetry / Teleservice Where: Thailand River System What: It is SCADA, Measure Rain Fall, Water Level and IP CAM monitoring How: Wireless Modbus SCADA / Telemetry / Teleservice solution by AMIT Data Logging Event Management Modbus Gateway Multi-WAN Reliability Cellular Connectivity Solution Benefits Project Summary Local Monitoring (Devices & Sensors) Multi-WAN ADSL & Cellular Manage Server (SCADA/Master) Project Requirement Modbus Data Manage Fieldbus Network Scenario Diagram IP CAM Water Level Sensor Rain Gauge Rain Gauge System DSLAM Control Network AAA UTM DB SCADA /OPC Cloud ACS UDR UCE VPN Concentrator IOG761-0TDA1 LTE/3G ADSL Ethernet RS232/485 10

Commercial Water Heater monitoring & maintenance Wireless Modbus SCADA / Telemetry / Teleservice Where: Japan Commercial Building What: It is SCADA, Monitoring and Maintenance for Water Heater System and peripheral equipments How: Wireless Modbus SCADA / Telemetry / Teleservice solution by AMIT Data Logging Event Management Modbus Gateway Dual-SIM Failover Reliability Cellular Connectivity Solution Benefits Project Summary Local Monitoring (Devices & Sensors) Cellular-WAN Manage Server (SCADA/Master) Project Requirement Modbus Data Manage Fieldbus Network Scenario Diagram Control Certer SCADA OPC HQ NOC IP CAM GPRS/3G/4G 1*DI+1*DO Alarm Sensor Water Heater System IOG700-0xCR1 Data Logging LTE / 3G DI / DO Ethernet RS232/485 11

Dual-SIM Failover Reliability Cellular Connectivity Integrate Solar Power Solution Wireless Modbus SCADA / Telemetry / Teleservice Where: In Taiwan, application of the Solar Power System What: It is SCADA, Monitoring and Maintenance for Solar Power System and peripheral equipments How: Wireless Modbus SCADA / Telemetry / Teleservice solution by AMIT Event Management Modbus Gateway Dual-SIM Failover Reliability Cellular Connectivity Solution Benefits Project Summary Local Monitoring (Devices & Sensors) Cellular-WAN Manage Server (SCADA/Master) Project Requirement Modbus Data Manage Fieldbus Network Scenario Diagram Control Certer IP CAM SCADA OPC HQ NOC IOG500-0x001 GPRS/3G/4G Solar Panels LTE / 3G Ethernet RS232/485 VCC GND Battery Charge Controller 12

Fish Farming Project Wireless Modbus SCADA / Telemetry / Teleservice Where: In south of Taiwan along the coastal areas What: It is SCADA, Monitoring and Maintenance for Fish Farming System and peripheral equipments How: Wireless Modbus SCADA / Telemetry / Teleservice solution by AMIT Event Management Modbus Gateway Dual-SIM Failover Reliability Cellular Connectivity Solution Benefits Project Summary Local Monitoring (Devices & Sensors) Cellular-WAN Manage Server (SCADA/Master) Project Requirement Modbus Data Manage Fieldbus Network Data Logging Scenario Diagram Control Certer SCADA OPC HQ NOC IP CAM IOG700-0xCR1 1*DI+1*DO Alarm Sensor GPRS/3G/4G Water-Pump Data Logging LTE / 3G DI / DO Ethernet RS232/485 PLC more extend I/O Alarm Sensor 13

Multi-Cellular Modules Cellular Connectivity Lightning Strike Counting System Wireless M2M SCADA / Telemetry / Teleservice Where: In Europe, the Lightning Strike Counting System were laid in various places What: It is SCADA, Monitoring and Maintenance for Lightning Strike Counting System and for their big- data collecting How: Wireless SCADA / Telemetry / Teleservice solution by AMIT Event Management Failover Reliability Multi-Cellular Modules Cellular Connectivity Solution Benefits Project Summary Local Monitoring (Devices & Sensors) Cellular-WAN Manage Server (SCADA) Project Requirement Multi-Cellular Data Manage WAN Failover Scenario Diagram Control Certer SCADA OPC HQ NOC IDG851-LTGT1 Dual LTE/3G Failover Backup Charge Controller Solar Panel LTE / 3G Ethernet VCC GND Backup Power System 14

Smart Grid(/IEC) Substation Wireless IEC 101/104 Smart AMR Where: In India, for power distribution projects What: Electricity needs to be transmitted in long distance, need to make the power transmission and whole system to be reliable How: to provide multi-wan and failover connection ability, plus the dual SIM redundant mechanism Event Management IEC Gateway Multi-WAN Reliability Cellular Connectivity Real-time Connectivity Solution Benefits Project Summary Local Monitoring (Devices & Sensors) Wireless Uplink Manage Server (SCADA/Master) Project Requirement IEC 101/104 Data Manage Fieldbus Network Remote Control Center SCADA Data Server Scenario Diagram FTU IOG761-0T002 DSLAM FRTU / IED LTE/3G Ethernet RS232/485 15

E-mail: sales@amit.com.tw Concentration Konzentration 專注 농도 专心 Concentratie Concentración Incumbo Concentrazione Concentração Cосредоточение コンセントレーション Contact AMIT TEL: +886-6-5058026; FAX: +886-6-5058068 http://www.amit.com.tw; E-mail: sales@amit.com.tw