WE WORK TOGETHER WE WIN TOGETHER

Slides:



Advertisements
Similar presentations
Pneumatic Valves Lesson 4.
Advertisements

ADX 150 – Engine Repair ADX 170 – Climate Controls
Thermostats, Pressure Switches, and Other Electric Control Devices
Refrigerators.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
TYPES OF MECHANICAL SYSTEMS
Purpose Body Making module is designed for bending the laminated foil film in the shape of a tube, for welding the side seam and for cutting bodies with.
Heating Control Devices
Objective of the session.
Copyright © 2014 Delmar, Cengage Learning Electrical Accessories Instructor Name: (Your Name) 10 CHAPTER.
Control Valves: Specifications, Sizing & Technologies
Simple Pressure Control Valves
FIRST Pneumatics Team 1425 Wilsonville Robotics. Agenda Components Components Basic System Design Basic System Design Applications Applications Tricks.
Pneumatic Control Valves
Larox Flowsys T HE S OLUTION Y OU ´ VE B EEN L OOKING F OR.
HVACR416 - Design Humidification. Relative Humidity 1.Air in the home is artificially dried out when it is heated. 2.Because warm air expands, this expansion.
MICE Target Review Chris Booth Sheffield 12 th June 2006.
Actuators.
Electric control Presented by Andrew Mitch Sav Little Phil Justin.
CONTROL VALVE - THEORY & SIZING
STEAM HEATING.
Hydronic Mechanical Controls
Abs.
Health and Safety Training Standards in Design and Technology
HVACR416 - Design Grills, Registers, and Diffusers.
Temperature Control Loop
Actuators. Pneumatic Power Cylinders As compressed air moves into the cylinder, it pushes the piston along the length of the cylinder. Compressed air.
Pneumatic and hydraulic actuation system (cont.)
 Switches are commonly employed as input devices to indicate the presence or absence of a particular condition in a system or process that is being monitored.
1 HVAC122 - Gas Gas Valves. 2 Solenoid Gas Valves The solenoid gas valve is the simplest of all valves. This valve has an electrical magnetic coil which.
Control Theory Control System Objectives  Establish a final condition  Provide safe operation  Eliminate the human element  Assure economical operation.
Direct Hot Water. What Cold Water System is Pictured? What hot Water System is Pictured?
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
BASIC AUTOMATIC CONTROLS UNIT 16 ADVANCED AUTOMATIC CONTROLS
Session 6 - Agenda BREAK Activity Est. Time 1. Agenda
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Valves.
INTRODUCTION TO ELECTRONIC INSTRUMENTATION Chapter 11 INTC 1305 – 01 CONTROL VALVES AND REGULATORS Vern Wilson.
Copyright © 2010 Delmar, Cengage Learning. ALL RIGHTS RESERVED. Unit 36 Electric Motors, Drives, and Controls.
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
Engineering Notebook - Part 4 Tumbler Research Section Overview of Build Lesson 1 Basic Vocabulary Motors / Batteries Name: Per #:
New Electric Actuators EA Type
EEN-E1040 Measurement and Control of Energy Systems Control II: Controlled devices, control in energy technology, complex systems Nov 7th 2016.
Double Acting Cylinder
Introduction to Electronic Fuel Systems
Electronic Fuel Injection
Making Circuits Safe SNC1P1 Findlay.
Topics covered in this presentation:
Cylinder Cushioning mechanism
Basic principles of hydraulic symbols
Actuators and directional control valves
Actuators & Directional Control Valves
VALVES CONTREN Series #
Valves.
Outcome 4 Mechanical central heating controls Unit 208: Central heating systems.
EEN-E1040 Measurement and Control of Energy Systems Control II: Controlled devices, control in energy technology, complex systems Nov 2nd 2017.
T-6B On-Board Oxygen Generation System (OBOGS)
BASIC PNEUMATICS.
Module – 4: Single Acting Cylinder
Introduction to Electro-pneumatic
T-6B On-Board Oxygen Generation System (OBOGS)
UNIVERSITÁ DEGLI STUDI DI SALERNO
Chapter 7: Classroom and shop manuals
Fluid Power System Electrical Control
Presentation transcript:

WE WORK TOGETHER WE WIN TOGETHER TRAINING SLIDE SHOW WE WORK TOGETHER WE WIN TOGETHER

GENERAL AIR DAMPERS In the next few slides we are going to run through the general applications of Air dampers, see the terminology of the actuator parts as well as description of everyday terms used in the field.

Belimo as you will know has many applications that we are capable of motorising. Some of them you will know, like Fire Dampers, Control Dampers and Smoke ventilation Dampers. We have been able to use the Belimo motors in other fields such as Incubators, Fume hoods, windows to name a few. By explaining how the motor works and how we were able to use it in these fields i hope you will see more opppertunity.

Belimo motors are mostly 90° turning We do have linear stroke actuators that move R L L UP / FOWARDS DOWN / BACKWARDS

LM - 5Nm can do approximately 1m² NM - 10Nm can do approximately 2m² As we have many motors in our different ranges i would like to break it down and give you a some basic guidelines: LM - 5Nm can do approximately 1m² NM - 10Nm can do approximately 2m² SM - 20Nm can do approximately 4m² GM - 40Nm can do approximately 8m² LF - 4Nm can do approximate 0.8m² NF - 7Nm can do approximately 1.4m² AF - 15Nm can do approximately 3.3m² PPT-Vorlage

I would like to break this down and simplify it for you: We have many adaption's to our products for example we can add switches or have a square shaft in stead of round or we can have modulating control. I would like to break this down and simplify it for you: LM...-S = Actuator with Switches PPT-Vorlage

Anti rotation bracket Shaft is either square or round Mechanical stops Change direction of stroke Part number Description of function Manual override Cable insert and wire

PPT-Vorlage

PPT-Vorlage

Below is a table to help you understand the Belimo Part numbers: Range Voltage Switches Modulating LM24A LM 24V   LM24A-SR yes LM230A 230V LM230A-S NM230A NM NM230A-S SM24A SM SM24A-SR GM24A GM GM230A AF230 AF LF24-S LF LF230 NF24-SR NF NF230-S

We have seen the picture with the labels e have seen the Pics of the applications we have seen the break down of the part number now lets look at the terminology of the terms used in the field: Rotary- A movement that is in a left to right movement. Linear - A movement that is up and down. Shaft- The extension of the damper that fits through the actuator. Manual override- The button that allows us to override the gears so we can move the motor.

Cable Gland/insert-. The part where the electric cable is Cable Gland/insert- The part where the electric cable is fixed to the motor. Mechanical stops- The small metal parts on the motor that we can adjust to stop the motor at the required degree of rotation. NM Torque- The measuring unit to measure the resistance or force of a specific item i.e.: damper blade resistance Nm: Newton Meter IP Rating- IP rating is the universal protection rating. IP54 = dust proof IP67 = water proof

Housing- The out side of the motor Spring Return- A motor that has a built in spring, the spring is activated will spring when the power to the motor is interrupted either by a fire, test or power failure and cut cables. Modulating- A way of controlling the motor to move according to the requirements of the controller or the application, we use a 0-10V control signal. 0V closed 10V Open Open/Close- A description for a motor that does nothing other than power open or power close Thermal Trip- A device that is placed in the ducting to act as a sensor for smoke or fire that once tripped will set a motor into the fail safe function. EG 72°C PPT-Vorlage

Shaft round-. A motor that has a built in spring, the spring is Shaft round- A motor that has a built in spring, the spring is activated will spring when the power to the motor is interrupted either by a fire, test or power failure and cut cables. Square Shaft- The square hole in the motor that the damper shaft fits through this is also known as form fit PPT-Vorlage

SAFETY /FIRE RATED MOTORS Safety motors or Fire rated motors are the range of motors that Belimo has Pioneered and are the market leaders for in Europe. The Fire Rated motors are motors that abide by the Standards of the highest safety regulations. Lets look at the difference between the AF and BF to see the major differences. Its good to know this as the laws IN SA are changing and we are starting to meet up with the EU and American standards for safety. PPT-Vorlage

PPT-Vorlage

As seen in the video smoke is the worrying factor in a building as it moves faster than fire and is the main cause of fire related deaths. Up to 80% of all fire related deaths are from smoke inhalation . In SA there are no Regulations as to the specifications of the fire Damper motors. The SABS only requires that the damper remain closed for 2 hours at around 300°C. The rest of the world (Americas/Europe/Asia) the motor is part of the Damper application and just as important to prevent the damper from moving in a safety application. PPT-Vorlage

AF230 Round Shaft Part Number Wiring Schematic PPT-Vorlage

BF230 Square Shaft Part Number Wiring Schematic PPT-Vorlage

The AF/LF/NF range all have spring return. Doesn’t have steel components cannot have built in thermal trips doesn’t have a spring that meets the fire regulations Can only have 1 built in limit switch The BLF/ BF range all have spring return Does have steel components Can have built in thermal trips Does have a spring that will hold once sprung to 1000°C Has a mandatory 2 built in limit switches. PPT-Vorlage

Doesn’t have the Certifications to be allowed use in fire applications Has a round shaft. Doesn’t have the Certifications to be allowed use in fire applications Has a square shaft Has all the requirements to be used in fire safety applications it is the biggest selling fire damper motor in Europe PPT-Vorlage

WATER VALVES AND APPLICATIONS Valves in a system can be used for various applications fan coil units, bypass, shut off, control of hot and cold water. Belimo has a variety of valves that we offer Butterfly valves, Globe valves, Ball valves, FCU valves and PICCV valves. By understanding the use and operation of the different valves you be more comfortable in using them. PPT-Vorlage

The 3 main types of valves. Ball valve - A valve that is controlled by a ball in the body either for open/close or control Globe valve- A valve that is normally heavy cast iron and has a linear stroke it’s used for mainly for controlling the flow of water. Butterfly valves- A valve that's main operation is for shutoff but has been adapted to be suitable for Control Belimo’s 3 way valve are mixing valves which will be explained in the next few slides. PPT-Vorlage

BALL VALVE Seat Stem Neck Thread Ports PPT-Vorlage

B AB A A B PPT-Vorlage

The cold water flows into the valve and mixes with the hot water As you can see in the 2 way valve (first valve) the water flows directly through and we can only control the volume of water in the system. In the 3 way valve (second Valve) you see the flow of the water coming in from 2 ports and leaving the 3rd it works as follows: Port A is the cold water port B is the hot water Port AB is the mixed water. The cold water flows into the valve and mixes with the hot water To the correct flow and temperature that is preset by the system The water then leaves the valve Through port AB at the correct Flow and temperature to allow for heating or cooling as per the System requirements. PPT-Vorlage

GLOBE VALVE Spindle Seat Neck Inlet Flanges Ports PPT-Vorlage

A AB B PPT-Vorlage

As seen in the above diagram you will see the same function as you saw in the Ball valve the difference between the 2 is that the ball valve is rotary and the Globe valve is Linear the Ball valve can only be offered up to 50mm and the globe valve up to 150mm. The operation is as in the Ball valve the water enters through port A and meets the flow from port B they mix and the required flow and temperature then leaves through port AB. PPT-Vorlage

BUTTERFLY VALVES Stem Neck Flange Paddle Rubber seal PPT-Vorlage