Experience with combined Fe55 / Tycho SNR calibration

Slides:



Advertisements
Similar presentations
EPIC Calibration Meeting, Mallorca Update of EPIC pn noise suppression K. Dennerl, 2009 March 31 Mallorca, Spain, 2009 March 31 – April 1 EPIC Calibration.
Advertisements

EPIC Calibration Meeting, Mallorca Update of EPIC pn long-term monitoring K. Dennerl, 2009 March 31 Update of EPIC pn long-term monitoring Mallorca, Spain,
EPIC Calibration Meeting, Mallorca Low energy calibration with the Vela SNR K. Dennerl, 2009 March 31 Low energy calibration with the Vela SNR Mallorca,
XMM EPIC MOS Jenny Carter EPIC Calibration Mallorca, 5 th -7 th Nov x3 binning pattern experiment Richard (Tao) Song, Jenny.
XMM EPIC MOS Jenny Carter EPIC Calibration Mallorca, 26 th -27 th Oct Cross calibration of RGS and MOS using Zeta Puppis Jenny.
EPIC Calibration Meeting, K. Dennerl VILSPA/Spain, 2003 Mar Temporal variation of the energy response determined with the internal calibration source.
Astrometry and EPIC flux cross-calibration in 2XMMp/2XMM Silvia Mateos R. Saxton, S. Sembay and the XMM-Newton Survey Science Centre.
Clusters as calibration tools S. Molendi (IASF-MI)
XMM EPIC MOS Andy Read EPIC Calibration Meeting Mallorca, Spain 01/02/05 What can we do with Pattern 31s? - Central pixel (red) has.
EPIC Calibration Meeting, Mallorca K. Dennerl, 2005 February 1 CTI.. update for EPIC pn Long-term behaviour of the CTI.. for EPIC pn.
XMM 1 EPIC MOS Monitoring CAL/OPS Meeting MPE
XMM-Newton 1 Michael Smith, ESAC PN Monitoring MPE, May 2006.
XMM-Newton 1 Michael Smith, ESAC PN Monitoring Palermo, April 2007.
Experience with combined Fe55/Vela SNR calibration - MOS Andrea Tiengo INAF, IASF-Milano In collaboration with: Mariachiara Rossetti (IASF-Milano) Martin.
EPIC Calibration Meeting, MPE K. Dennerl, 2006 May 04 EPIC pn at low energies: LW mode Properties of EPIC pn at low energies: LW mode.
Marcus Kirsch Science Operations & Data Systems Division Research & Scientific Support Department Page 1 XMM-Newton MOS Timing Mode calibration Marcus.
The problem with double event patterns (M. Brusa, K. Dennerl – MPE) EPIC CAL/OPS meeting - MPE.
Marcus Kirsch Science Operations & Data Systems Division Research & Scientific Support Department Page 1 XMM-Newton EPIC Calibration of the EPIC MOS Timing.
EPIC Calibration Meeting, K. Dennerl Saclay/France, 2003 Sept offset map correction Spatial variation of the energy scale Energy correction for pixels.
XMM-Newton 1 M.Stuhlinger/P.Calderon, ESAC Re-appearance of the MOS1 CCD1 meteorite column during revs Madrid, 23. March 2010.
Energy Calibration using SNRs: preliminary results Andrea Tiengo INAF, IASF-Milano Mallorca, 6 November 2007 EPIC Calibration Meeting.
MOS 3x3 mode slow slew survey Richard Saxton October 2006.
XMM EPIC SOC Richard Saxton Background, Operations & Calibration (BOC) meeting Mallorca, 30/03/09-01/04/09 The Timing Mode PSF Richard Saxton, Maria Diaz.
XMM EPIC MOS Steve Sembay EPIC Calibration Meeting Tuebingen 03/02/03-06/02/03 MOS Cooling Results and Current Response Both MOS Cameras.
EPIC Calibration Meeting, Mallorca K. Dennerl, 2006 October 26 EPIC pn: Jumps in the energy scale Sudden jumps in the absolute energy scale and their origin.
The EPIC-pn spectral response Frank Haberl EPIC Cal meeting, Tübingen, February 2003 Status of the pn spectral response in SAS5.4.1 Latest developments.
NRCO #71: preliminary analysis of MOS data Andrea Tiengo INAF, IASF-Milano Mallorca, 8 April 2008 EPIC Calibration Meeting.
Mallorca EPIC Cal Meeting - February 2005 Darren Baskill: XMM project: MOS monitoring.
EPIC Calibration Meeting, K. Dennerl Saclay/France, 2003 Sept Spatial variation of the energy scale Energy correction for pixels with an incorrect.
1 XMM-Newton Extended Source Analysis Software Steve Snowden & Kip Kuntz  Publicly Released 5 April 2006  XMM-Newton Extended Source Analysis Software.
EPIC Calibration Meeting, Mallorca K. Dennerl, 2006 October 26 CTI.. update for EPIC pn EPIC pn: Update on the CTI, the absolute energy scale and the energy.
EPIC Calibration Meeting, Mallorca K. Dennerl, 2006 October 26 Suppression of the low-energy noise Suppression of the low-energy noise: an improved approach.
XMM-Newton 1 Michael Smith, ESAC PN Monitoring Mallorca, October 2006.
XMM 1Michael Smith, ESAC EPIC PN Monitoring Provided by Michael Smith.
EPIC Calibration Meeting, K. Dennerl VILSPA/Spain, 2004 March Detector noise & Vela observations application to Vela observations EPIC pn detector.
XMM 1 EPIC MOS Monitoring CAL/OPS Meeting Mallorca
XMM EPIC MOS Andy Read EPIC Calibration Meeting Saclay 24/09/03-25/09/03 Analysis of the X-ray PSF PSFs in the CCF MCG C273.
Marcus Kirsch, XMM-Newton European Space Astronomy Center Page 1 EPIC ESAC Energy calibration refinement of the EPIC-pn Burst mode M.G.F. Kirsch 1, E.
Marcus Kirsch, XMM-Newton European Space Astronomy Center Page 1 EPIC ESAC Long term EPIC in-orbit calibration plan Marcus G. F. Kirsch.
RGS/MOS-cooling Results February 03, 2003 L. Metcalfe 1 Science Operations & Data Systems Division Research & Scientific Support Department Page 1 XMM-Newton.
XMM EPIC MOS Steve Sembay Mallorca 06/11/07 Report on three NRCO calibration observations On axis observation of absorbed Seyfert.
Chandra X-Ray Observatory CXC Paul Plucinsky EPIC Cal Update on ACIS Calibration 1) Update to the ACIS contamination model 2) Temperature-dependent.
1 XMM-Newton Extended Source Analysis Software Steve Snowden & Kip Kuntz  Publicly Released 5 April 2006  XMM-Newton Extended Source Analysis Software.
EPIC Calibration Meeting, Madrid Correcting spatial inhomogeneities of the absolute energy scale K. Dennerl, 2010 March 23 Correcting spatial inhomogeneities.
EPIC Calibration Meeting, Mallorca Origin of gain offsets K. Dennerl, 2008 April 8 Origin of gain offsets: new insights from eROSITA calibration Mallorca,
SAG+SASWG Meeting Potsdam /15 PN Tasks – Status Report (update since Leicester) Hermann Brunner - MPE  epframes:  The dark quadrant problem.
A look at XMM slew data Richard Saxton, Andrew Read, Michael Freyberg, Bruno Altieri, Puri Munuera.
The Slow Slew Survey Richard Saxton / Pedro Rodriguez November 2006.
Marcus Kirsch, XMM-Newton European Space Astronomy Center Page 1 EPIC ESAC Status of the EPIC calibration Presentation for XMM Newton UG 18 May 2006 Marcus.
EPIC Calibration Meeting, Madrid Experience with combined Fe 55 /Vela SNR calibration K. Dennerl, 2010 March 23 Experience with combined Fe 55 / Vela SNR.
The onboard calibration for the spaced-row charge injection of the Suzaku XIS Hideki Uchiyama, Yoshiaki Hyodo, Hiroya Yamaguchi, Hideyuki Mori, Takeshi.
The soft N132D to study the gain of the EPIC-pn camera
The XMM-Newton Slew Survey
Periodicity Search in X-ray data of RX J
Figure 1. Three light curves of IRAS 13224–3809 in 600-s bins
Gerard Fitzpatrick Tutor: Andy Pollock Trainee Project 2009
Cross-Cal paper Kristin Kruse Madsen.
A large XMM-Newton project on SN 1006
Asami Hayato (RIKEN / Tokyo Univ. of Sci.)
XMM-Newton slew sources A quick analysis
A large XMM-Newton project on SN 1006
EPIC Calibration & Operations Meeting
Energy Response of the X-ray Imaging Spectrometer (XIS) on Suzaku
The spectral properties of Galactic X-ray sources at faint fluxes
TRAINEE PRESENTATION The North and South Ecliptic Pole fields population Project supervisors: R. Saxton N. Loiseau Trainee student: Jaime Abella Payá.
Update of EPIC pn long-term monitoring
Thierry Montmerle (Grenoble)
A puzzule of the keV lines
Long-term trends in EPIC pn energy response
RESULTS FROM TYCHO SNR CALMEDIUM OBSERVATION
Presentation transcript:

Experience with combined Fe55 / Tycho SNR calibration NRCO 71 EPIC Calibration & Operations Meeting Mallorca, Spain, 2008 April 7 - 8

Internal calibration source onboard XMM-Newton / EPIC-pn Al-K Mn-K

30 ks in 2000  210 ks in 2008 30 ks 10 ks

Experience with combined Fe55 / Tycho SNR calibration General plan: start with ‘normal’ Tycho observation add the internal calibration source finish with ‘normal’ calclosed observation does the internal calibration source disturb the Tycho observation ? does Tycho disturb the calclosed measurement ? Unfortunately, this sequence was scheduled as three independent observations, performed in a non-contiguous mode superposition with short-term changes in the absolute energy scale no firm conclusions about potential changes of the absolute energy scale possible however: general idea about ‘calopen’ observations

Experience with combined Fe55 / Tycho SNR calibration 1) Tycho FF Medium, 2007-12-30 / 19:55 – 2007-12-31 / 03:37, 27 ks

Experience with combined Fe55 / Tycho SNR calibration 2) Tycho FF Cal Medium, 2008-01-01 / 19:58 – 2008-01-02 / 09:59, 50 ks

Experience with combined Fe55 / Tycho SNR calibration 3) Calclosed, 2008-01-03 / 01:06 – 2008-01-03 / 08:11, 25 ks

1) Tycho FF Medium, 2007-12-30 / 19:55 – 2007-12-31 / 03:37, 27 ks

2) Tycho FF Cal Medium, 2008-01-01 / 19:58 – 2008-01-02 / 09:59, 50 ks

3) Calclosed, 2008-01-03 / 01:06 – 2008-01-03 / 08:11, 25 ks

Narrow-line images at Mn-K: 5.70 – 6.05 keV adu ΔE = 350 eV

Narrow-line images at Mn-K: 5.70 – 6.05 keV scaled to the same exposure time ΔE = 0.35 keV Tycho CalClosed Tycho + CalClosed

all energy bands centered on Mn-K Tycho + CalClosed all energy bands centered on Mn-K ΔE = 0.35 keV ΔE = 1.0 keV ΔE = 2.0 keV ΔE = 5.0 keV

Narrow-line images at Al-K: 1.375 – 1.575 keV adu ΔE = 200 eV

Narrow-line images at Al-K: 1.375 – 1.575 keV scaled to the same exposure time ΔE = 0.20 keV Tycho CalClosed Tycho + CalClosed

calclosed

Tycho

Tycho + calclosed

Mn-K calclosed

Mn-K Tycho + calclosed

Al-K calclosed

Al-K Tycho + calclosed

CTI determination: Illustration of the Template Cross Correlation method (EPIC pn) 25 macro pixels, 20-29 singles per macro pixel

calclosed CTI

Tycho + calclosed CTI

Tycho + calclosed CTI 

Experience with combined Fe55 / Tycho SNR calibration Tycho + calclosed seems ok for Mn-K, but not for Al-K Tycho better suited for LW than for FF Calclosed & LW no useful combination  are there celestial calibration targets which are better suited for a combined Fe55 exposure ?

Vela SNR

Vela SNR (62 ks)

calclosed (25 ks)

Vela SNR + calclosed (scaled to 62 ks)

Experience with combined Fe55 / Tycho SNR calibration Vela + calclosed might be an interesting alternative: the parts of the Vela SNR covered by the FOV are similarly extended as the internal calibration source the X-ray surface brightness of the Vela SNR is similar to that of the internal calibration source the X-ray spectrum of the Vela SNR is almost complementary to that of the internal calibration source But the Al-K region would need to be checked in detail..