RAINMAKER and RAINMAKER Enviro Spot Free Water Systems RAINMAKER and RAINMAKER Enviro
What is R/O? Reverse Osmosis Water that has had the dissolved solids removed (TDS) Super pure H2O Water that dries spot free Same as many bottled drinking water
What is it for Chemical Applications Final Rinse Applications Improved customer satisfaction
How is it used? Spot Free water is generated and stored in holding tanks in the equipment room Automatically Machines are plumbed to use R/O when needed Pre-soak Wax Clear Coat Tri-Foam Spot Free Rinse
How does it work? Water is pumped under pressure through R/O membranes Some of the water passed through the filters and on to the storage tanks Some of the water does not go through the filters and is sent to the next filter or down the drain Each filter in the RYKO R/O systems will produce about 1.5 gallons of pure R/O water per minute
What are the Benefits Improved chemical effectiveness Improved chemical efficiency Improved chemical constancy No spotting drying Higher revenues and profitability
When is R/O needed? Anytime the TDS reading is more than 100 Anytime improved wash quality is desired Anytime for up sell to consumers On nearly every touch free wash
What is the difference between the RAINMAKER and the Enviro? The Enviro does not need a water softener The Enviro uses a special water conditioning bar Performance is the same
How Do I Size a Holding Tank? (Number of gallons of R/O use per wash) x (number of washes per hour) = R/O usage per hour 15 x 20 = 300 gallons per hour usage (# Membranes) x (1.5 gallons) x 60 = R/O production per hour 3 x 1.5 x 60 = 270 gallons per hour production ((R/O Usage per hour - R/O production per hour) x Number of hours continuous use = Holding tank min size (300 – 270) x 8 = 240 gallon holding tank
What does it mean….. Competitors say 3000 GPD system? 3000/24/60= 2.08 gallons per minute Talk about efficiency… One membrane is about 50% efficient Each additional membrane plumbed in series is also about 50% efficient
What kind of maintenance is required? Periodically membranes need to be cleaned Periodically membranes wear out and need to be replaced
RAINMAKER and Enviro Good for chemical applications Good for spot free drying Good for better customer satisfaction Good for profitability Good for you to sell
RAINMAKER and RAINMAKER Enviro Spot Free Water Systems RAINMAKER and RAINMAKER Enviro