Distribution Load Flow using OpenDSS (An Open Source Software of EPRI)

Slides:



Advertisements
Similar presentations
Lecture Notes 4 Per Unit System
Advertisements

HossamTalaat - MATLAB Course - KSU - 19/09/ IEEE Student Branch - College of Engineering - KSU Getting started with Power System Blockset By Prof.
Today’s Topics 1- The per unit system 2-Transformer Voltage Regulation
Announcements Be reading Chapter 3
Power Factor Correction KW KVA KVAR. Reasons behind P.F corrections n Power Factor is the ratio between Power and Apparent Power n Motors.
LOGO LINEAR CIRCUIT ANALYSISSAJID HUSSAIN QAZI MEHRAN U.E.T, KHAIRPUR CAMPUS A.C POWERS AND POWER FACTOR.
1 Locating Harmonic Sources System Impedance Impacts of Harmonics K-factor Interharmonics.
1 Training Session on Energy Equipment Electricity Presentation from the “Energy Efficiency Guide for Industry in Asia” ©
Plant Utility System (TKK-2210)
Example 1 A 9375 kVA, 13,800 kV, 60 Hz, two pole, Y-connected synchronous generator is delivering rated current at rated voltage and unity PF. Find the.
Transformers Mechanical and Electrical Systems SKAA 2032
Power in AC Circuits ELEC 308 Elements of Electrical Engineering
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Fourth Edition, by Allan R. Hambley, ©2008 Pearson Education, Inc. Lecture 16 Phasor Circuits, AC.
1 1. Power and RMS Values. 2 Instantaneous power p(t) flowing into the box Circuit in a box, two wires +−+− Circuit in a box, three wires +−+− +−+− Any.
EMLAB Polyphase circuits. EMLAB 2 1. Three Phase Circuits Advantages of polyphase circuits 2. Three Phase Connections Basic configurations for three.
Announcements For lectures 8 to 10 please be reading Chapter 3
1 1. Power and RMS Values. 2 Instantaneous power p(t) flowing into the box Circuit in a box, two wires +−+− Circuit in a box, three wires +−+− +−+− Any.
Frankfurt (Germany), 6-9 June 2011 Pyeongik Hwang School of Electrical Engineering Seoul National University Korea Hwang – Korea – RIF Session 4a – 0324.
POLYPHASE CIRCUITS LEARNING GOALS Three Phase Circuits Advantages of polyphase circuits Three Phase Connections Basic configurations for three phase circuits.
Announcements Please read Chapter 3; start on Chapter 6
1 1. Power and RMS Values. 2 Instantaneous power p(t) flowing into the box Circuit in a box, two wires +−+− Circuit in a box, three wires +−+− +−+− Any.
1 Distribution Networks For Large Cities: EPRI Research on Modelling and Analysis Roger DUGAN Sr. Technical Executive Electric Power Research Inst. US.
Power factor correction √. POWER FACTOR IS THE COSINE OF ANGLE BETWEEN V AND I.
AN- NAJAH NATIONAL UNIVERSITY OPTIMUM DESIGN AND PERFORMANCE FOR NABLUS NETWORK Submitted To : Dr. Maher Khammash Prepared By : Haitham Sharaf Ahmad Odeh.
KEM_Cespedes_A1 Colombia Session 3 – Block 1 Barcelona May ACCURATE MODELING FOR LOSSES REDUCTION USING A REAL-TIME POWER FLOW AT ENELVEN.
EXAMPLE A pole mounted 100kVA distribution transformer has the following characteristics R 1 = 1.56  R 2 =  X 1 = 4.66  X 2 =  Volts Ratio.
BASIC ELECTRICAL TECHNOLOGY DET 211/3 Chapter 6: Single Phase Transformer (Continued)
EE1 PEEE Refresher Class Power Part 4 notes by T. Ernst EE1 – Power Part 4 NotesFall 2011, Page 1.
Optimal Power Flow- Basic Requirements For Real Life.
REACTIVE POWER COMPENSATION
Instantaneous power p(t) flowing into the box
Hao Zhu Dept. of Electrical & Computer Engineering University of Illinois, Urbana-Champaign ECE 498HZ: Power Distribution System Analysis.
FUNDAMENTAL OF ELECTRICAL POWER SYSTEMS (EE 270)
NEUTRAL CURRENT IS NOT ZERO
Hao Jan (Max) Liu Dept. of Electrical & Computer Engineering University of Illinois, Urbana-Champaign ECE 498HZ: Power Distribution.
Lecture 10 Transformers, Load & Generator Models, YBus Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Hao Zhu Dept. of Electrical & Computer Engineering University of Illinois, Urbana-Champaign ECE 498HZ: Power Distribution System Analysis.
Power Factor Correction The Definitive power solution
Announcements Please read Chapter 6
بسم الله الرحمن الرحيم Design and analysis of an electric power system, with the design of a load flow program using MATLAB.
APFC-03 Reactive Power Compensation Method & Settings
ECE 476 POWER SYSTEM ANALYSIS
CHAPTER 6 SPECIAL TRANSFORMERS Electrical Machines.
ECE 476 POWER SYSTEM ANALYSIS
B4.2 Power System One-Line Diagrams
Management Of Tulkarm Electrical Network
BASIC ELECTRICAL TECHNOLOGY DET 211/3
Module B3 More on Three Phase Analysis
ECEN 460 Power System Operation and Control
Module B4 Per Unit Analysis
Per-Unit System.
Improvement the electrical distribution network
ECEN 460 Power System Operation and Control
ECE 476 POWER SYSTEM ANALYSIS
Coordinating Worldwide Distribution Planning Model Development via an Open Source Modeling Platform Roger Dugan (EPRI), Davis Montenegro (UniAndes),
Distribution Feeder Voltage Regulation and Control
ELEC-E8409 HIGH VOLTAGE ENGINEERING
ECEN 460 Power System Operation and Control
1. Power and RMS Values.
Φ 3. Transformer Models. Turns ratio 7200:240 (30 : 1)
Jignesh Solanki Research Assistant Professor West Virginia University
ECE 333 Green Electric Energy
Why does power factor matter Make-up of distribution capacitor banks
POLYPHASE CIRCUITS LEARNING GOALS Three Phase Circuits
ECE 333 Green Energy Systems
ECE 576 Power System Dynamics and Stability
ECE 576 POWER SYSTEM DYNAMICS AND STABILITY
Module B4 Per Unit Analysis
CIM in a Triple-Store Database for Distribution Power Flow
Three Phase Transformers
Presentation transcript:

Distribution Load Flow using OpenDSS (An Open Source Software of EPRI)

Contents of presentation Definition of Loads Definition of Lines Definition of Capacitors Definition of Transformer/Voltage Regulator Writing Master File COM Interfacing with MATLAB Writing MATLAB Program for Load-flow (Examples for Loads, Lines, Capacitors, Transformer/VR are defined for IEEE-13 Node Test System) Data can be obtained from https://ewh.ieee.org/soc/pes/dsacom/testfeeders/

Definition of Loads Required Platform are .DSS or .txt or .m Remember style is same as in .DSS New Load.671 Bus1=671.1.2.3 Phases=3 Conn=Delta Model=1 kV=4.16 ~kW=1155 kvar=660 For .m DSSText.Command=‘New Load.671 Bus1=671.1.2.3 Phases=3 Conn=Delta Model=1 kV=4.16 kW=1155 kvar=660 ’; Available Load Models in OpenDSS Model Description 1 Constant P and Q 2 Constant impedance load 3 Constant P, Quadratic Q 4 Linear P, Quadratic Q 5 Rectifier load 6 Constant P; Q is fixed at nominal value 7 Constant P; Q is fixed impedance at nominal value 8 ZIP model

Definition of Lines Writing Line Code New linecode.mtx601 nphases=3 BaseFreq=60 ~ rmatrix = (0.3465 | 0.1560 0.3375 | 0.1580 0.1535 0.3414 ) ~ xmatrix = (1.0179 | 0.5017 1.0478 | 0.4236 0.3849 1.0348 ) ~ units=mi Create Line (Can be one, two, or three-phase lines) New Line.650632 Phases=3 Bus1=RG60.1.2.3 ~Bus2=632.1.2.3 LineCode=mtx601 Length=2000 ~units=ft

Capacitor Definition New Capacitor.Cap1 Bus1=675 phases=3 kVAR=600 kV=4.16 New Capacitor.Cap2 Bus1=611.3 phases=1 kVAR=100 kV=2.4

Definition of Transformer/ Voltage Regulator Transformer Definition New Transformer.Sub Phases=3 Windings=2 XHL=(8 1000 /) wdg=1 bus=SourceBus conn=delta kv=115 kva=5000 %r=(.5 1000 /) XHT=4 wdg=2 bus=650 conn=wye kv=4.16 kva=5000 %r=(.5 1000 /) XLT=4 Regulator Definition New Transformer.Reg1 phases=1 XHL=0.01 kVAs=[1666 1666] Buses=[650.1 RG60.1] kVs=[2.4 2.4] %LoadLoss=0.01 new regcontrol.Reg1 transformer=Reg1 winding=2 vreg=122 band=2 ptratio=20 ctprim=700 R=3 X=9 New Transformer.Reg2 phases=1 XHL=0.01 kVAs=[1666 1666] Buses=[650.2 RG60.2] kVs=[2.4 2.4] %LoadLoss=0.01 new regcontrol.Reg2 transformer=Reg2 winding=2 vreg=122 band=2 ptratio=20 ctprim=700 R=3 X=9 New Transformer.Reg3 phases=1 XHL=0.01 kVAs=[1666 1666] Buses=[650.3 RG60.3] kVs=[2.4 2.4] %LoadLoss=0.01 new regcontrol.Reg3 transformer=Reg3 winding=2 vreg=122 band=2 ptratio=20 ctprim=700 R=3 X=9

Defining Master File new circuit.MasterIEEE13 ~ basekv=115 pu=1.0 phases=3 bus1=SourceBus ~ Angle=30 MVAsc3=20000 MVASC1=21000 Redirect Transformers Redirect Lines Redirect Loads Redirect Capacitors Set Voltagebases=[115, 4.16, .48] Calcv Solve

COM Intefacing DSSObj = actxserver('OpenDSSEngine.DSS') DSSText=DSSObj.Text

Writing MATLAB File clear all; clc; DSSObj = actxserver('OpenDSSEngine.DSS'); if ~DSSObj.Start(0), disp('Unable to start the OpenDSS Engine'); return end DSSText = DSSObj.Text; DSSCircuit = DSSObj.ActiveCircuit; DSSText.Command='Compile (C:\Users\Admin\Desktop\SaturdayExample\MasterIEEE13.dss)'; DSSText.Command='batchedit load..* Vmin=0.8'; DSSText.Command='solve mode=snap'; DSSText.Command='Solve'; DSSText.Command='Export Losses'; DSSText.Command='Export Voltages'; DSSText.Command='Export Currents';

Losses Report

Voltage Report