Automatic Transfer Switches

Slides:



Advertisements
Similar presentations
Closed Transition ATS’s
Advertisements

L.T Circuit Breakers.
Automatic Transfer Switch (ATS)
Variable Frequency Drives Bypass Options
B757 Review Questions.
Contactors & Relays.
Earthing systems, Harmonics Currents and GFP
Earthing systems, Harmonics Currents and GFP
Setup/Installation/Operation of an Environmental Control Unit (ECU)
DOD Microgrids The Missing Link: Microgrid Applications Michael Dempsey P.E. Burns & McDonnell June 12, 2013 © 2013 Burns & McDonnell. All Rights Reserved.
©2011, The McGraw-Hill Companies, Inc. Chapter 4.
LAFA Food Distribution July 26, Introduction:
© 2010 Eaton Corporation. All rights reserved. Neutral Switching of Grounded Sources Dave Loucks, PE.
Introduction to ATS Scott Kolek – ATS Global Product Manager 2006 Annual Power Quality Meeting.
Proposed Design and the Operation of a Disconnecting Device for Small EG Installations Prepared by Hendri Geldenhuys.
GE Consumer & Industrial Multilin  Single & Three phase models  Specific mount CT’s  Rectangular & Toroidial models  Plastic case & cast models  Multi.
Electrical Power Systems
The Association of Electrical and Medical Imaging Equipment Manufacturers Understanding GFCIs Developed by the NEMA 5PP Personnel Protection Technical.
© 2011 Ericson Manufacturing, Willoughby, Ohio
The Vanjen Group • Manufacture's Representative – Power Generation/Oil & Gas • Covering TX, OK, LA, AK, in some cases NM and MS • Extensive.
Manufacture's Representative – Power Generation/Oil & Gas Covering TX, OK, LA, AK, in some cases NM and MS Extensive Power Gen Experience Extensive Docking.
Chapter 7 SYSTEM PROTECTION
Interconnect Protection of Dispersed Generators
Residential Construction Unit 5- Energy Efficiencies and Mechanicals Mr. Todzia.
Electrical Distribution Training
LAFA Food Distribution
Utility Engineers, PC.  Generation  Transmission  Distribution.
Electrical Power Distribution. Forms of Energy All forms of energy fall under two categories POTENTIAL Stored energy or energy of position (gravitational)
SERVICE ENTRANCE EQUIPMENT
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Switches and Over Current Protective Devices Class Instructor ALPHER E. DE VERA, uap.
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Push Button Station and Relay
Generation and Distribution of electrical energy Grade 8.
BUILDING LOAD NORMAL OPERATION 1. ATS are in normal position connected to utility source 2. All generator set paralleling circuit breaker open.
Chapter 8. Electrical Systems
Announcements Design Project has firm due date of Dec 4
PROTECTION AGAINST INDIRECT CONTACT
Presentation On Office security system
© 2004 Refrigeration Training Services - Refrigeration Categories v1.1
Interconnect Protection of Dispersed Generators
Unit 45: Circuits and components Dr
Advanced Fuse-Saving Techniques
Shipboard Electrical Distribution
Electrical Systems Electrical Systems
GROUND-FAULT GROUND-CHECK MONITOR
Presented by: LADWP November 14, 2017
Principles & Applications Residential Wiring Concepts
THREE-PHASE GROUND-FAULT BASICS
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Chapter 7 System Protection
Electrical Installation Practice 2
ELECTRICAL POWER-II Electrical engineering sixth semester
New 240V NEMA Configurations for IT Installations
EET 323 – Electrical System Design Lecture 4: Wiring Devices
Overcurrent Protection— Fuses and Circuit Breakers
ABB SACE Emax 2 ANSI C37 / UL1066 Concept Global Product Management
EET 323 – Electrical System Design Lecture 9: Grounding
Interconnection of AES With The Grid
Friday, December 28, 2018 ABB SACE Emax 2 Concept
The Safe Use of Electricity
Conductor A material, such as copper, that permits the flow of electricity; usually refers to the a wire.
Safety Meeting Topics Standby Generator Safety
-Bypass/Isolation Switches-
Objectives Learn about Electricity Pricing Electric systems.
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Substation Equipment's
Presentation transcript:

Automatic Transfer Switches Presented By Oscar Gross Kohler Power Systems Take you through a journey of how to select a specific ATS based on all availabale configurations and in the processs explain what an ATS is, how it operates…

Need to keep the lights ON if utility power goes out It’s your first day at OG Engineers, Inc. You have been assigned to design and specify the on site emergency power system for a new facility in the area.

How do we get power from genset to load?

Automatic Transfer Switch (ATS) A UL1008 listed device that automatically transfers the load from a primary (normal) power source (utility) to a secondary (emergency) source (generator) Has three (3) connection points Normal Emergency Load Manages Loss / Return of normal sensing Time delays Genset start and stop

What the three dots in the box look like Contactor Controller Contactor - Three connection points (Normal, Emergency, Load) Controller – Manages Loss/Return of Normal, time delays and start/stop of generator

How to Specify an ATS Operation Single Line Controls Enclosure Transfer Type Amp Rating Withstand Rating Frame Type Neutral Switching Pre/Post signals Load Add/Shed Metering Monitoring Test Nema 1 Nema 12 Nema 3R Nema 4 Nema 4X The single lie is the map and the specification defines the operation (direction) and the requirements (rules) we must follow…. After we determine both of these things, only then can we select the controls and define how to package the controls

Amp Rating What is the load? Need to protect ATS Need to protect with circuit breakers 1200A 1200A 1200A

Withstand Rating

Frame Type - Bypass Isolation Allows for continuity of power during maintenance of the contactor Two TS mechanisms in parallel Automatic - Drawout Manual - Fixed Allows for servicing the draw-out contactor

Frame Type - Service Entrance Rated Breaker Based Service entrance automatic transfer switches incorporate an isolating mechanism and over-current protection on the utility supply Potential Cost Savings Potential footprint reduction Contactor Based External Breaker Integrated Breaker

ATS – 3 Pole or 4 Pole (Ground Fault) Number of Poles 3 Pole Solid Neutral – Generator is NOT a separately derived source Breaker trip units on the generator can NOT detect a ground fault 4 Pole Generator is a separately derived source Breaker trip units on a generator can detect a ground fault

3 - Pole Genset is NOT a separately derived source To simplify the drawings, we are only showing one of the three phases. Electricity generated leaves the generator and will need to come back to the neutral of the source Everything gen produces will come back.

3 - Pole Genset is NOT a separately derived source Transformer Switchgear 3 Pole ATS Generator Phase Neutral Ground To simplify the drawings, we are only showing one of the three phases. Electricity generated leaves the generator and will need to come back to the neutral of the source Everything gen produces will come back. You should NEVER bond the neutral to the ground on the emergency source when the Genset is NOT a separately derived source. Load

3 - Pole Genset is NOT a separately derived source Point A has a ground fault to one of the phases. Power comes back through point B. (Grounded neutral) and flows back to the gen through the neutral. The algebraic sum of the three phases will still sum up to the current on the neutral. Ground fault is undetected. Sensing CT sees that the current from all phases matches what is returning back to neutral.

4 - Pole Genset is a separately derived source GFP is required on the emergency source Multiple reasons to select a 4 pole ATS Generator is a separately derived source Ground Fault Protection for the emergency source is required

Review

How to Specify an ATS Operation Single Line Controls Enclosure Transfer Type Amp Rating Withstand Rating Frame Type Neutral Switching Pre/Post signals Add / Shed Metering Monitoring Test Nema 1 Nema 12 Nema 3R Nema 4 Nema 4X

Transfer Type - Open Break before make Power will momentarily be interrupted during live/live power transfers Very fast – Hard for human eye to detect

Transfer Type - Closed Make before break Under 100ms (6 Cycles) May increase short circuit current contribution (gen + utility) Some utilities require additional protective relays Passive synchronization In phase monitor May need to run genset slightly fast

Transfer Type – Programmed Transition Also know as delayed transition Has center off position Load shed to center off Lets motor and high inertia loads stop Not recommenced for “10 Sec.” loads

How to Specify an ATS Operation Single Line Controls Enclosure Nema 1 Transfer Type Amp Rating Withstand Rating Frame Type Neutral Switching Pre/Post signals Load Add/Shed Metering Monitoring Test Nema 1 Nema 12 Nema 3R Nema 4 Nema 4X

Interface to the system

ATS Controller Setup and monitoring Time delays Metering Engine start Utility stable Metering Normal source Emergency source Testing (Calendar Based Test) Test with Load Test with NO Load Remote control and monitoring Hard wired Modbus Load Control Load Shed/Load Add

What if there is more than one ATS? Allows the ability to load shed based on load priority

ATS can load shed connected loads Current metering package

Pre / Post Transfer Signals Time Based load control: Pre/Post transfer signals based on timer Current based load control: Adds/Removes loads based on current measurement

How to Specify an ATS Operation Single Line Controls Enclosure Nema 1 Amp Rating Withstand Rating Frame Type Neutral Switching Transfer Type Pre/Post signals Load Add / Shed Metering Monitoring Test Nema 1 Nema 12 Nema 3R Nema 4 Nema 4X

Typical installation

Typical Installation

Manager-Engineered Solutions THANK YOU!!! Oscar Gross Manager-Engineered Solutions KOHLER POWER SYSTEMS Office: Atlanta, GA Mobile: 920-226-9751 Oscar.Gross@KOHLER.com