ABB STOTZ-KONTAKT GmbH Intrusion Detection Technology SSM/x SafeKey Switching Module 2011 | Slide 1.

Slides:



Advertisements
Similar presentations
Trouble - Shooting ELR - Electric Latch Retraction.
Advertisements

 Salient characteristics / Approvals  Non-illuminated Switches  Illuminated Switches  Pilot Lights  Contact Elements Control & Signalling Devices.
Electrical Fundamentals
DUE Security and Fire Alarm Systems LEARNING OUTCOME 7B Describe design overview and location considerations.
Module 2: Hardware and Terminology
Systems Approach Burglar Alarm Project PROBLEM SITUATION DESIGN
Introduction  Exceptionally long life & high switching speeds.  Non contact, zero operation force.  Wear & maintenance free operation.  Bounce free.
ELECTRICAL CIRCUITS.
Electrical Control Components
©Copyright 2015 SmartLog V5 ™ with Turnstile. SmartLog V5™ with Turnstile Charleswater.co.uk The patented* EMIT SmartLog V5™ is designed for fast, frequent,
 Salient characteristics / Approvals  Non-illuminated Switches  Illuminated Switches  Pilot Lights  Contact Elements Control & Signalling Devices.
DTMF stands for Dual Tone - Multi Frequency and it is the basis for our telephone system. The touch-tone® phone is technically a DTMF generator that.
ABB i-bus® KNX Fan Coil Actuator FCA/S
Fan Coil Actuator FCA/S 1.x.x.2
Fan Coil Controller FC/S 1.1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Weather Unit, Weather Sensor
G. Schlag / STO-GM / Novembre 2012
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX i-bus® Tool
STO/GM December 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX DGN/S DALI Gateway for emergency lighting © STO/G - Slide 1.
Scrolling LCD using Arduino.
2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX ISx/S 5.1 IP Switch Master and Slave IPM/S 1.1 IP Patch Module © STO/G - Slide 1.
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Line Coupler LK/S4.2
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
AA/S 4.1 Analogue Actuator AAM/S 4.1 Analogue Actuator Module
ABB i-bus® KNX Weather Station
August 2012 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Energy Module EM/S Energy Actuator SE/S © ABB 20 May 2018 | Slide 1.
ABB i-bus® KNX Fan Coil-Actuator FCA/S 1.1M
Blower-/Fan Coil-Actuator
ABB i-bus® EIB Display and Control Tableau
ABB i-bus® KNX The new Room Master RM/S 3.1 and RM/S 4.1
ABB i-bus® KNX Weather Unit , Weather Sensor
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Telephone Gateway TG/S 3.2
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Premium, RM/S 2.1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Basic, RM/S 1.1
Zone Terminal MT/U Technical Overview
2N® Access Unit.
2N® Access Unit Bluetooth
2N® Access Unit Touch Keypad
ABB i-bus® EIB / KNX Weather Station WS/S 4.1
Visit for more Learning Resources
Connections Topology of Apollo ACS.
DIGITAL CALCULATOR USING 8051
EPR = Electronic Products and Relays
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Time Switch FW/S 8.2.1
Security Module, MDRC SCM/S 1.1
Jörn Kruse / STO-G / Mai 2009 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX The „smaller“ Room Controller RC/A 4.2 © STO/G - Slide 1.
RAILWAY TRACK SNAP NOTIFICATION
Jörn Kruse / STO-G / ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Brightness Sensor Interface HS/S © STO/G - Slide 1.
ABB STOTZ-KONTAKT GmbH
ABB i-bus® EIB / KNX Binary Input BE/S x.x.1
2N® Access Unit Fingerprint
2N® IP Uni Cost-effective IP Intercom.
2N® Access Unit Touch Keypad
Commissioning Power Supply NTI/Z
2N® Access Unit RFID (125kHz or 13.56MHz).
Universal Interface, 12-fold, FM US/U 12.2
Universal I/O Concentrator UK/S 32.2
ABB i-bus® KNX Analogue Input
ABB STOTZ-KONTAKT GmbH DALI-Light Controller DLR/S M
ABB i-bus® KNX The new I/O-Actuators IO/S and IO/S
2N® Access Unit Bluetooth
2N Access Unit 2.0 Multi-technology access control readers.
ABB i-bus® EIB / KNX Application Unit Time ABZ/S 2.1
ABB i-bus® EIB / KNX Data Logging Unit BDB/S 1.1
ELECTRICAL CIRCUITS S.MORRIS 2006
UNIT 9 Relays.
ELECTRICAL CIRCUITS More free powerpoints at
UNIT 9 Relays.
The efficient interface for lighting control
2N® Access Unit Bluetooth
Presentation transcript:

ABB STOTZ-KONTAKT GmbH Intrusion Detection Technology SSM/x SafeKey Switching Module 2011 | Slide 1

Intrusion Detection Technology SafeKey Switching Module Application Simple integration and evaluation of Safekey wall readers (WEL/A and WELT/A) for potential-free switching of electrical components, for transferring a set/unset request to a Security Terminal MT/x or to connect to KNX via a push-button interface or binary inputs Usage Use of digital chipkeys and / or keycodes for easiest and safest operation Direct control of electric door openers and garage doors High-quality stainless steel arming device for KNX security systems Connection to KNX via Security Terminal, push-button interface or binary input No exchange of the wall reader lost keys necessary Use of one key for multiple wall reader © ABB 2011 | Slide 2

Intrusion Detection Technology SafeKey Switching Module A choice of two basic functions: Set/unset request to the Security Terminal MT / x or potential-free switching for control of electrical door opener, garage doors or for connection to KNX Triggering a switching process via chipkey, keycode or code combination (key and code) Up to 512 chipkeys or keycodes manageable 12 V AC or DC voltage for supply voltage selectable surface-or flush-mounted version available © ABB 2011 | Slide 3

Intrusion Detection Technology SafeKey Switching Module Function Set/Unset request: normal or delayed setting/unsetting Acoustic setting/unsetting confirmation via the buzzer in the Safekey wall reader Push-button or switch behavior selectable for the output Function potential-free switching: Output as NC or NO contact selectable Activation time of the output is adjustable from 1 to 100 seconds © ABB 2011 | Slide 4

Circuit Diagramm SafeKey Switching Module Legend: 1) Supply voltage 12 V DC/AC 2) DIP Switch 3) Output E for setting/unsetting request 4) Output F for potential-free switching 5) Acknowledgement C 6) Programming Key 7) Rotary potentiometer 8) Connection of SafeKey Wall Reader © ABB 2011 | Slide 5

Technical Data SafeKey Switching Module © ABB 2011 | Slide 6

Technical Data SafeKey Switching Module © ABB 2011 | Slide 7

DIP Switch Function Overview SafeKey Switching Module © ABB 2011 | Slide 8

Function Set/Unset request SafeKey Switching Module © ABB 2011 | Slide 9

Function Potential-Free Switching SafeKey Switching Module © ABB 2011 | Slide 10

Rotary Potentiometer SafeKey Switching Module © ABB 2011 | Slide 11

Productinformation SafeKey Switching Module Surface-mounted version SafeKey Switching Module, SM SSM/A 2CDG 240 019 R0011 Flush-mounted version SafeKey Switching Module, FM SSM/U 2CDG 240 020 R0011 © ABB 2011 | Slide 12

Accessories SafeKey Switching Module SafeKey Wall Reader, SM, stainless steel WEL/A, ES GHQ 3050 023 R0001 SafeKey Wall Reader with Keypad, SM, stainless steel WELT/A, ES GHQ 3050 024 R0001 SafeKey Wall Reader with Keypad, SM, matt chrome-plated WELT/A, MC GHQ 3050 024 R0011 SafeKey Chipkey SCS GHQ 3050 027 R0001 © ABB 2011 | Slide 13

© ABB 2011 | Slide 14