Quantifit Controlled Negative Pressure Fit Test Protocol

Slides:



Advertisements
Similar presentations
Fit Testing N95 Respirators in Health Care Facilities Kate Durand, MHS California Department of Public Health Occupational Health Branch Regional Trainings.
Advertisements

Zebra® 105SL™ * Removing and Installing Printhead
SKA-Pak Plus Mobile Air Cart Con-Space Link
Connecting Your Computer Monitor Cable Electrical power for monitor.
Introducing Digital Talking-Book Machines Standard player Advanced player.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
M40 FIELD PROTECTIVE MASK
Unit 7.2. Respirator fit testing TB Infection Control Training for Managers at National and Subnational Level.
2 Fire Fighter Qualifications and Safety Skill Drills.
TESTING Dräger PSS 7000 Breathing Apparatus GENERAL TEST
Manlius Fire Department Annual SCBA & RIT Pak Familiarization Drill
Troubleshooting Guide. Table of Contents 2 Shower Filter 3 Leak Between Top Housing & Filter4 Leak Between Swivel Collar & Housing5 Leak at Top of Swivel.
Powerpoint will automatically advance this presentation, so you can just sit back and watch.
Setting up and using an LED projector with computer & video input device MEDT 7477 Submitted by: Team 6 Has Slone.
Manual resuscitators case study Manual resuscitators case study by Elizabeth Kelley Buzbee RRT RCP-NPS RCP Kingwood College Respiratory Care department.
1 Zebra 170 XiIII Plus Removing and Installing Printhead Calibrating Head Resistance Print Quality Adjustments.
Introducing the Mobile Sink with Cabinet Base and Self Contained Water Supply BH, Inc.
HOW WELL DO YOU KNOW THE BASICS OF USING YOUR COMPUTER?
Supplied-air regulator Copyright © 2013 by The S.E.A. Group.
Powered Air-Purifying PARTICLE Respirator (PAPR) Copyright © 2013 by The S.E.A. Group.
OHD Quantifit Training
Powered Air-Purifying Respirator (PAPR) Copyright © 2015 by The S.E.A. Group.
Supplied-air regulator Copyright © 2013 by The S.E.A. Group.
Newport HT50 Ventilator Orientation & Training
Common Uses & Lab Ideas: Tips, Tricks & Calibration Notes Measurements Sensor Exploration Challenge Materials EKG Sensor PS-2111 Identify fluctuations.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
COBAE - Smart Classroom Technology Vic Catalasan For immediate in-class assistant please call X1500 or
Troubleshooting Computers in the FHC. Hardware Issues Computer will not turn on – Check power cable – Check power strip Computer is on, but screen is.
AUDIO VISUAL TRAINING Center for Academic Success.
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
Respiratory Safety Public Safety Murray State University.
TIDBITS Hose made pryor to July 1987 will be taken out of service Hose that is frozen will be service tested again Color’d Hoses All test gauges.
World Leader In Gas Detection & Sensor Technology Stand Alone Calibration Station SM 2000 Series.
1 Fire Fighter Qualifications and Safety Skill Drills 2.
1 Skill Drill 2-7 Donning a Face Piece Step 1: Fully extend the straps on the face piece. Step 2: Place your chin in the chin pocket. 2 Step 3: Fit the.
Surface Rescue Swimmer School Mask, Fins, and Snorkel Mask, Fins, and Snorkel LT 4.2.
Full Face Masks w/Plug-In Connector Instructions for Use March O2 TNG, MRT Trainee - POM 1 Panorama Nova RP.
How well does the face-piece seal to the persons face? What is Fit Testing About determining if a specific respirator fits to a persons face All respirators.
WS50(Stratacache) Software updating guide (By Using USB)
Oregon Robotics Tournament and Outreach Program RCX Basics.
AUDIO VISUAL TRAINING Vaughn Eames-Lite Class. LITE CLASSROOM EQUIPMENT Lite Class LCD Projector/Built In Screen Laptop Connection (VGA Cord) Control.
AUDIO VISUAL TRAINING Wilkins Theatre-Black Box. BLACK BOX EQUIPMENT IN CLASS Black Box LCD Projector/Built In Screen Laptop Connection (VGA Cord) Control.
Protect Yourself From Chemical/Biological Contamination Using Your Assigned Protective Mask.
How To Uninstall HP Printer Drivers From Your PC?.
Copyright © 2016 by The S.E.A. Group
CASD Mobile Labs.
MACS CPAP System Self Guided Tour.
R1 Fundamentals of Refrigeration
HOW WELL DO YOU KNOW THE BASICS OF USING YOUR COMPUTER?
Air Distribution Control
1(844) Fix HP Printer Error Code 0xc19a0013 Code
1(844) How to resolve HP Printer Error 0x07a74dd6
Sometimes, you may require or wish to print from your iPhone 6/6s/7 (plus), but it would be little difficult to print from an iPhone 6/6s/7 (Plus) directly,
Information and Communications Technology
HOW WELL DO YOU KNOW THE BASICS OF USING YOUR COMPUTER?
Ballast Dust on Worksites
T-6B On-Board Oxygen Generation System (OBOGS)
Hutchinson Hall-Black Box
Hennings Hall-Black Box
Part 2 – Supplied-air Respirators
R1 Fundamentals of Refrigeration
Stand Alone Calibration Station
1/17/2019.
Concorp, Inc. - Respiratory Protection Training. Revision – B
Oregon Robotics Tournament and Outreach Program
Recording your narrations
T-6B On-Board Oxygen Generation System (OBOGS)
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
Canon Printer Paper Jam Error? Dial Canon Printer Helpline
Presentation transcript:

Quantifit Controlled Negative Pressure Fit Test Protocol

The CNP Technology Developed in 1992 OSHA Accepted in 1998 Incorporates a faster 5-step protocol Measures mask integrity during the test Offers a specific SCBA protocol for high-risk applications The Fastest Quantitative method available to date Can be calibrated to NIST standard National Institute of Standards and Technology Record keeping with FitTrackGold

Controlled Negative Pressure(CNP) Controlled Negative Pressure REDON Protocol Used by the OHD Quantifit testing instrument Uses Controlled Negative Pressure to directly measure respirator leakage. CNP precisely measures the leak rate by determining the amount of air that leaks into the respirator during the fit test. Direct Measurement Similar to a PosiChek Test for User Face Seal Uses Air as the Challenge Agent

CNP – How it Works The respirator inlets are capped with test adapters. If an inhalation valve is present, it will be propped open. Test subject holds his or her breath for no more than 10 seconds….actual test is only 8 seconds At the same time, the Quantifit establishes and maintains a slight vacuum (ie...controlled negative pressure) inside the mask Since the respirator inlets are sealed, all sources of leakage into the mask are through the face-to-facepiece seal The volume of air drawn out during the 8 seconds is equal to the leak rate into the mask through the face-to-facepiece seal.

Fit Factor= _______________ Fit Factor Formula Breathing Rate (BR) expressed in liters/min. DIVIDED BY Leak Rate (LR) expressed in cc/min Fit Factor= _______________ Breathing Rate Leak Rate

Controlled Negative Pressure Smokers are not an issue Test can be performed anywhere Each Step can be restarted without starting completely over No issues with eating or drinking beforehand CNP has a faster 5 step protocol (3 - 4 Minutes) Uses Air to challenge the mask

Daily Requirements for CNP Fit Testing Daily Calibration (if needed) Attach Adapters / Prop Inhalation Valve Select or Input the Test Subject Info into FitTrack Gold Software Select Test Type (Full or Half face?) Begin Test Face Forward Bending at waist Shake Head (3 Seconds) REDON 1 REDON 2 Save & Print

Things Needed Power Cord

Things Needed Triple Tube Assembly

Things Needed White Trigger Button

Things Needed Fit Test Adapter

Connect to the Computer that has Fit Track Gold Software installed Set Up Connect to the Computer that has Fit Track Gold Software installed

Plug in Keyboard if not using Computer Set Up Plug in Keyboard if not using Computer

Set Up For Daily Calibration – Plug in ONLY the two WHITE hoses to the “Dual Tube Cal” ports

SET UP Optical Sensor Push Nob for scrolling and selecting

Perform Daily Calibration If needed, the Quantifit will prompt you to perform the Daily Calibration

Perform Daily Calibration Plug the Male & Female side of the “Triple Tube Assy” into the front of the QF. These two below are called the “Dual Tubes”

Perform Daily Calibration Using the Male & Female side, plug the “Triple Tube Assy” into the front of the QF.

Perform Daily Calibration Plug the White Trigger Button into the “Trigger Port”

Perform Daily Calibration Plug the opposite end of the interchangeable white tubes to the “Dual Tube Cal” ports on the Back Don’t Worry, the blue tube won’t fit

Perform Daily Calibration Start Daily Cal Takes about 1 minute

Items Needed to perform the QNFT Test w/ CNP Items Needed for CNP Testing OHD Quantifit Fit Test OHD Adapter for the Facepiece An Inhalation Valve Prop or a Quarter Turn Filter Adapter

Setting Up for the Test Prop Open or remove the Inhalation Valve

Setting Up for the Test If the mask is an SCBA, you will use a cartridge adapter which will automatically prop open the valve

Setting Up for the Test Connect the OHD Adapter. The adapter will either be a one piece or two piece adapter

Setting Up for the Test Dual Tube Side (WHITE) Single Blue Tube

Setting Up for the Test Single Adapter

User Seal Check Not Required but may help with proper fit or find a leak before the test begins

Performing the Test Use the “Redon Protocol” for Half Face Masks

Performing the Test Use the “SCBA Protocol” for Full Face Masks & SCBA’s

Performing the Test Each Step is 8 seconds long and requires that the trigger button be pressed for the entire 8 seconds. After 8 seconds of testing, the pressure inside the mask will automatically discharge without having to release the trigger button.

Test Steps (1) Facing Forward: Face forward, while holding breath (2) Bending Over: Face parallel to the floor, while holding breath for (3) Shake Head: Shake head vigorously side to side for about 3 seconds and then Face forward, while holding breath (4) REDON 1: Remove the respirator mask, loosen all straps, and then redon the respirator mask. Face forward, while holding breath for (5) REDON 2: Remove the respirator mask, loosen all straps, and then redon the respirator mask. Face forward, while holding breath

Performing the Test 1. Face Forward, hold a comfortable breath sealing off air to your lungs, press the button for 8 seconds Note: Subject should hold breath until the pressure from the mask is released.

Performing the Test 2. Bending at the Waist, hold a comfortable breath sealing off air to your lungs, press the button for 8 seconds Note: Subject should hold breath until the pressure from the mask is released.

Performing the Test 3. While facing forward Shake head left to right for about 3 seconds and then stop. Then hold a comfortable breath sealing off air to your lungs, press the button for 8 seconds and then release. Note: Subject should hold breath until the pressure from the mask is released.

Performing the Test 4. Redon the Mask. Take the mask completely off and then put it back on. Face Forward, hold a comfortable breath sealing off air to your lungs, press the button for 8 seconds Note: Subject should hold breath until the pressure from the mask is released.

Performing the Test 5. Redon the Mask again. Take the mask completely off and then put it back on. Face Forward, hold a comfortable breath sealing off air to your lungs, press the button for 8 seconds Note: Subject should hold breath until the pressure from the mask is released.

Troubleshooting - Understanding the Graph

Two Ways to use the Quantifit Computer & Software You can operate the Quantifit with a PC or Laptop through the FitTrack Gold software. Print from Software Stand Alone With the Keyboard plugged in, you can input the information needed to perform the test You can print directly from the Quantifit to an HP printer The Quantifit will hold 500 tests onboard Transfer the saved test data from the Quantifit to Fit Track Gold Software via Thumb drive USB directly to the computer