Maybe, it is time to clean up!

Slides:



Advertisements
Similar presentations
IAQ, FILTRATION AND THE CONSUMER MARKET Matthew Klein, PE-ME, MBA Indoor Air Quality Solutions, Inc.
Advertisements

HVAC Systems and Their Role in Infection Control and Prevention
Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®
Acknowledges that HVAC systems play a role in the dissemination of diseases in buildings Key points: Infectious diseases can be transmitted via an airborne.
Heat Recovery for Commercial Buildings
AIR TECHNOLOGY We breathe approximately times a day and consume about 10,000 litres of air. Air Wellness Power5 Pro from Nikken: purification and.
A Comparison of: Conventional HVAC Filtration and UV and EcoQuest International’s Fresh Air and DuctwoRx Air Purification Systems with Space Certified.
Innovative Air Distribution for Healthcare Facilities.
Patentes Steril-Aire 5,334,347 Electric Discharge Device Aspects of the present invention are found in an electric discharge device comprising an envelope.
The absence of evidence is not the evidence of absence.
Indoor Air Quality / L.E.E.D. Gold and Net-zero IAQ = Dollars, Energy Savings, reduced absenteeism, and increased productivity.
Commercial & Office Buildings Schools Daycare Centers
Education and Indoor Air Quality IAQ = Dollars, Energy Savings, reduced absenteeism, and increased productivity.
Photo Catalytic Oxidation Passive Oxidative Technology.
Station 3 ?? Air Meters Combustion Analyzer Carbon Monoxide Carbon Dioxide Particles Air Flow Vane Anemometer Exhaust Flow Box Pressures CAZ Test.
Cabin Air Technologies, LLC Introduces the Cabin Air Purifier Portable Cabin Air Purifier in the center of rear seat Trunk version with armrest serving.
Air Pollution.
Air Pollution TSWBAT: Define air pollution.
AIR POLLUTION. Air Pollution created by man Burning of Fossil Fuels  Examples of fossil fuels: Oil and coal.
CLEAN AIR SEMINAR High Efficiency Duct Mount Air Cleaners Introduction to Selling.
Mansel A Nelson Institute for Tribal Environmental Professionals Basics Strategies for Maintaining Good Indoor Air Quality Indoor Air Quality in Tribal.
What do you think this means?. Learning Targets 8. Identify the causes and effects of pollution on Earth’s cycles. 9. Explain how pollution affects.
Indoor Environmental Quality: Investigating the Problem
Copyright National Air Filtration Association 2006 Rev. 2 Schools.
Weather, Climate, and the Atmosphere. Composition of the Atmosphere.
Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ.
Breathing Does Matter Healthy Breath Unhealthy Breathing An Affordable Health-Care Option.
ODOROX® Hydroxyl Generator Technology at Work HGI Industries Inc High Ridge Road Boynton Beach, FL Phone: (561) 735 ‐ 3701 Fax: (561) 735 ‐
Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)
HVACR416 - Design Introduction to IAQ. What is Indoor Air Quality Indoor air quality (IAQ) is a term used to describe the indoor climate of a building.
Environmental Health. Air Pollution Burning of fossil fuels producing sulfur dioxide, a yellowish brown gas Particulates in the air –Tiny solid particles.
Welcome to IAQ Series #1 The IAQ Business Model. Your Hosts for Today’s Conference are: Gary Elekes in Nashville, Tennessee Gary Oetker in Plano, Texas.
C L E A N A I R S O L U T I O N S The Camfil Farr Group A presentation.
ODOROX® Hydroxyl Generator Technology at Work. Restoring the Balance™ The Challenge: Indoor Air Quality (IAQ) Odour Volatile Organic Chemicals (VOC’s)
Air pollution Keith whitley. What is Air? Air is oxygen which is essential for our bodies to live. Air is 99.9% nitrogen, oxygen, water vapor and inert.
V3 vs. v4 New Protocols for LEED Tommy Linstroth, Principal.
1 1 Weatherization & Indoor Air Quality Impacts of Weatherization on Air Quality and Comfort Inside Your Home Prepared with the assistance of Jed Harrison,
1 Mansel A Nelson Institute for Tribal Environmental Professionals Basics of Indoor Air Quality Indoor Air Quality in Tribal Communities.
Welcome To Our Presentation 0f GENANO ® TECHNOLOGY For Senior Living Facilities.
Austin Pure Air Independent Agent - Products and Prices 2016 UNRIVALED PURIFICATION TO 1 NANO EVEN IN OUR SMALLEST UNIT Quiet Operation The GENANO 200.
1 SARS – Clearing the Air Jerome J Schentag, PharmD University at Buffalo FailSafe Air Safety Systems Corp
 Headquarters and distribution- Sterling, VA.  Offices is Baltimore and Pittsburgh.  Established in  32 employees.  Small business.  25,000.
SECTION 6 AIR CONDITIONING (HEATING AND HUMIDIFICATION) UNIT 34 INDOOR AIR QUALITY.
Global Plasma Solutions® Introducing the GPS-iClean™
IAQ Indoor Air Quality. What is poor IAQ Excessive pollutants in the air. This would be the same for a residence or work environment. The condition can.
PRESENTED BY ENG. PRISCILLA NAKIBONEKA SANITARY ENGINEER, MINISTRY OF HEALTH, UGANDA.
Pollution and the Environment
Education and Indoor Air Quality
NAFA Guide To Air Filtration
Road Show Introduction
Update on USGBC LEED and Air Filtration NAFA 2008 Annual Convention San Francisco, CA September 19, 2008 by Francis (Bud) J. Offermann PE CIH Indoor.
Air Pollution TSWBAT: Define air pollution.
Expeditionary Safe Linking Technologies to provide
AIR POLLUTION.
Conversion (Photo Catalytic Oxidation) Technology
Corporate Responsibility and Community Safety
Heating Ventilating and Air Conditioning
NAFA Certified Technician “Technicians For Life”
GVSU Case Study Analysis of HVAC filter using MERV 13 filter with low pressure drop design. 1.
1888 PressRelease - Miami Mold Specialists Announces Addition of Next Gen Hydroxyl Systems
Residential Indoor Air Quality
Human activities affect the atmosphere.
16/11/2018 Air Quality (OCR 21st Century) W Richards The Weald School.
Hospital & Healthcare Facilities
GeneralAire® UV Air Purification.
What are the 5 layers of the atmosphere, in order from top to bottom?
What is the difference between El Nino and La Nina?
At 1 1.2ppt Air Quality W&C Chapter 1.2 Pages
KG300 ATMOSPHERIC WATER SOLUTIONS
Presentation transcript:

Maybe, it is time to clean up! If You Could See the things you are breathing, would you hold your breath?

Where did all the nasty bugs go?

Genesis Panel Destroyed Them

Offering you technology that the big boys have used for years  Duplication of Natural Process “Detergent of the atmosphere” Katja Riedel and Keith Lassey explain how OH, the hydroxyl radical, works to cleanse the atmosphere of harmful trace gases. “Introducing OH, the hydroxyl radical Although it makes up about a fifth of our atmosphere, oxygen (O2) is not the main oxidant. Other molecules that are produced naturally in the atmosphere, including ozone (O3), the nitrate radical (NO3), and the hydroxyl radical (OH), are much more reactive, even if their atmospheric concentrations are low. Radicals are highly reactive because they have unpaired electrons which tend to transfer to other molecules.

Have you ever used hydrogen peroxide on a cut? Did it bubble and boil up? What was it doing? Destroying infection causing virus, bacteria and spores. Our panels create OH a more powerful oxidant than peroxide. We replicate the natural process naturally occurring in the troposphere.

What is the Product? How does the panel work? Testing Product Features Design Considerations Why they buy Applications

What is the product? Photo Catalytic Oxidation Panel (produces oxidizing agent) First Glance: Filter with a light in it?

Residential Unit Single Panel Product Features: Scalable / Easy Retrofit San Francisco Airport Catalyst Panel Residential Unit Single Panel Array of Panels Side or Front Load

How not to fail: First Impression/Key Not a Filter / Is a PCO Panel Think it is a filter; we have plenty (Customers in General) Call it a filter; Go home It is a panel and we have nothing like this Filter = Commodity Panel = Technology IAQ / Energy Sale Panel = Let us consider, Energy Advantage/ Problem Solution Panel / Use it to lock down a jobs for you } Who Buys Technology?

How does the panel work? KISS Method Have you ever used hydrogen peroxide on a cut? Did it bubble and boil up? What was it doing? Destroying infection causing virus, bacteria and spores. Our panels create OH. We are trying to replicate the natural process the troposphere uses to clean the air we breathe.  Duplication of Natural Process “Detergent of the atmosphere” Katja Riedel and Keith Lassey explain how OH, the hydroxyl radical, works to cleanse the atmosphere of harmful trace gases. “Introducing OH, the hydroxyl radical Although it makes up about a fifth of our atmosphere, oxygen (O2) is not the main oxidant. Other molecules that are produced naturally in the atmosphere, including ozone (O3), the nitrate radical (NO3), and the hydroxyl radical (OH), are much more reactive, even if their atmospheric concentrations are low. Radicals are highly reactive because they have unpaired electrons which tend to transfer to other molecules. The OH radical is the most important oxidant in the troposphere, the lowest part of the atmosphere (below about 10 km). Nobel Prize winner Paul Crutzen coined the phrase “detergent of the atmosphere” to describe this important cleansing role of OH. Most of the trace gases found in the troposphere are oxidised by OH into water-soluble products that are washed out by rain and snow. Specifically, OH is responsible for oxidising carbon monoxide (CO) and other carbon-based molecules, such as methane (CH4).” Water & Atmosphere 16(1) 2008 http://www.niwa.co.nz/sites/default/files/import/attachments/detergent.pdf   Caution: Two Types – Active (No people) Passive (Safe for Occupied Spaces)

Photocatalysis Process Redox reaction: A reaction in which electrons are transferred from a donor (the reducing agent) to an acceptor molecule (the oxidizing agent) Photocatalysis Process 11

Extensive 3rd Party and Field Testing Testing / Does it Work? Extensive 3rd Party and Field Testing Sample results from 3rd party testing. (With no pre-filter) PCO shows a single pass reduction in microbial contaminants. 12

Expected Results: Lower levels of VOC’s and Bio-aerosols in the conditioned space . 13

AHU’s: Location – In Air Stream Preferred down stream of coil Advantages - Low pressure drop (.05@500fpm) Easy to Service (12,000hr lamp) Requires little space (6” panel) Low energy (Cost of ODA) Sustainable (15 year panel) One Device – Three Solutions Cleans Coil Reduces VOCs Destroys Bio aerosols

Design Considerations: Design Goal (Global / At the Source) Destroys in the airstream with-in the panel (Residence time) Panels installed across airstream in a rack (Location) Collection & Type of Contaminates (Source & Concentration)

Why they buy: Hospitals: Airports: Schools: Animal Care: Casinos: Odors……. Heliports & Generators Surface Recharge Integrity of Design The O.R. no one will use State of the Art Airports: Odors Airborne pandemic Schools: Average Daily Attendance Resistant Strains (T.B.) E.P.A. “Tools for Schools” Lost teaching days Complaints Animal Care: Kennel Cough Odors Airborne Viral Casinos: Smoke Money Rooms Employee health (Liability Issues) Residential use; furnace accessories or room models mold, pollen, viruses , bacteria cooking odors

Applications Factory Mounted Retrofit RTU’s Induct Standalone Portable

Performance Climate Changer Factory mounted AHU (Trane PCC / Custom) Trane Performance Climate Changer

AHU Retrofit:

Curb Mounted RTU / Thybar

Panel In Curb Supply

Induct: Residential or Commercial

Standalone: Inlet Ducted Attached to Filter grilles Supply Out

Portable: For personal use or commercial Disasters, Floods, Odors, Mold, Remediation

Hospital St. Luke’s Vintage Houston TX 1. Source Location a. Close proximity to freeway b. Non attainment area c. Automotive and Diesel exhaust migrating into fresh air vents. d. Ongoing construction 2. Type of Problem a. Ultra fine particles from outdoor pollution ODA - TVOC load. b. Biologic reduction ( Risk reduction HAI ) 3. Personnel Location & Challenges a. Limited access behind air handles b. Factory Trane Install for new hospital c. Four story facility 250,000 sq ft. 4. Equipment sizing and location a. 8-Trane Air handlers b. 8-2008 Standard PCP Systems c. 48-PCP Standard Catalyst Panels d. 112 Assorted UVGI lamps e. Spec Merv 13 pre filters in non critical areas and HEPA Filtration in Critical Areas 25 25

Hospital John Muir Medical Center Concord CA 1. Source Location a. Close proximity to freeway b. Non attainment area c. Close proximity to Helicopter Landing Pad d. Ongoing construction 2. Type of Problem a. Ultra fine particles from outdoor pollution and high outdoor TVOC load. b. Stage 1 for helicopter odors c. Stage 2 Critical areas bio aerosol reduction 3. Personnel Location & Challenges a. Limited access behind air handles b. Dedicated fresh air unit for c. Five story 168 bed facility d. Field Retro 4. Equipment sizing and location a. One custom dedicated fresh air unit b. Stage 2, three AHUS 26 26

Hospital John Muir Medical Center Walnut Creek , CA O.R.s Sold 6/24/13 First Install Dedicated fresh air unit 9/9/11 First install at Walnut Creek 9/9/11 Equipment is being added to their 11 hospital as O.R.s are being upgraded Walnut Creek Retrofit 6/24/13 Concord Medical Center Retrofit 6/24/13 Heliport 1. Source Location a. Close proximity to freeway b. Non attainment area c. Close proximity to Helicopter Landing Pad d. Ongoing construction 2. Type of Problem Out Door Air a. Ultra fine particles from outdoor pollution and TVOC (emergency generators and heliports) Goal: Reduce Odor O.R.s a. Surgical Site Infection b. Surface Recontamination c. Maintain integrity of design (protection against filtration breakthrough) Goal: Reduce risk of Surgical Site Infection 3. Personnel Location & Challenges a. Limited access behind air handles b. Dedicated fresh air unit for c. Five story 168 bed facility d. Field Retro 4. Equipment sizing and location a. One custom dedicated fresh air unit b. Stage 2, Two AHUS 27 27

Atlanta Medical Retrofit TNET Healthcare Corp. Atlanta Medical Center Atlanta Georgia Brookwood Medical Center, Birmingham, Alabama Cypress Fairbanks Medical Center Houston, Texas Del Ray Medical Center, Del Ray Florida Palm Beach Gardens Medical Center, Palm Beach Florida Park Plaza Medical Center, Houston, Texas Providence Memorial, El Paso Texas Sierra Medical Center, El Paso Texas Sierra Providence East, El Paso Texas Tenet Hilton Head Hospital, Hilton Head, South Carolina West Boca Medical Center, Boca Raton, Florida Atlanta Medical Retrofit 1. Installs occurred in Critical Care Areas 2. Challenges Reduce biologic recharging of surface areas for reduction of HAIs Helo Pad off gassing Biologic reduction on Evaporator Coils Brookwood Medical Center Retrofit 28 28

Hospital Terrebonne General Medical Houma LA 1. Source Location a. High environmental fungal levels b. Physical Training Weight Room c. Limited Ventilation d. High people traffic 2. Type of Problem a. Odors from physical training b. Biologic reduction (Risk Reduction HAI ) 3. Personnel Location & Challenges a. Rooftop mechanical room isolated b. Field retrofit c. Four story facility 400,000 sq ft. 4. Equipment sizing and location a. 1-Trane Air handlers b. 1-2008 Standard PCP Systems c. 2-PCP Standard Catalyst Panels d. 8 Assorted UVGI lamps e. Spec MERV 13 pre filters in non critical areas 29 29

Airports San Francisco Airport T 2 Terminal 1. Source Location a. Jet Exhaust and Jet Fuel from runways & gates b. Large volume of people c. High levels of outdoor air required by code 2. Type of Problem a. High levels of outdoor CO & TVOCs b. Airborne Disease 3. Personnel Location & Challenges a. Humid environment / cost of maintenance using capture systems b. Ineffective (off gassing) c. Cost prohibitive 12 month replacement cycle of existing carbon 4. Equipment sizing and location a. 1 Custom AHUs totaling 600,000 +cfm b. T2 474 Catalyst Panels 576 UVGI Lamps c. T2 Equipment installed in the mixing box before the coils because of existing humidity levels and AHU manufacture specs. FAA Tower Location under construction T 2 T 3 T2 T3 575 Chain of Events: T2 Remodel Sold 9/5/09 IAQ Testing Admin Building 575 Sold 12/7/09 T3 Retrofit Phase 1 (Baggage Area) Sold 5/21/13 T3 Retro Flat Spec (Submittals) 1qtr. 2014 FAA Tower Flat Spec (Submittals 2qtr. 2014 30 30

Labs Medical Examiners Office & Labs 1. Source Location a. Decomposition bodies in various locations b. The issue - cadavers are moved through out building 2. Type of Problem a. Odors & bio-hazards b. The exhaust system was contaminating an area of several blocks around the facility. 3. Personnel Location & Challenges a. Units had to be near the source b. 12 inch wide returns 4. Equipment sizing and location a. 2 custom 2006 DTs and 4 portable 2006 GS b. The GS units are moved to populates areas. c. The DT units are in the returns near the source of the contamination. 31 Pictures Courtesy of Genesis Air, Inc. 31

Casino & Bingo Mohawk Bingo Palace and Casino 1. Source Location a. Environmental Tobacco Smoke 2. Type of Problem a. 30 foot open dome building b. 1600 bingo seats c. HVAC returns are in central location and out of smoke layer. d. Ash tray every 4 feet with 3 to 5 burning 3. Personnel Location & Challenges a. Placement of inlets in smoke layer b. 12 inch wide returns c. Incorporated with EMS system 4. Equipment sizing and location a. 18 2008 GS Units 2 2008 B3s & 6 2008 DTs b. GS units mounted 13 foot level in the smoke layer. c. odor control / AHU return grill mounted 32 Pictures Courtesy of Genesis Air, Inc. 32

Schools Bellevue Elementary 1. Source Location a. New Construction Late 2009 b. Outdoor Mold and Pollen c. Long Winters 2. Type of Problem a. Under ventilation in winter months b. 80% carpet facility c. Permanent animals in some classrooms 3. Personnel Location & Challenges a. Long Winters less ventilation b. Crowded Classrooms c. Chemicals brought from home by staff to spray or burn in classrooms 4. Equipment sizing and location a. 5 Trane M Series Air Handlers b. Genesis Air units field installed in AHUs during construction c. odor control & biologic control d. Case study available 33 Pictures Courtesy of Genesis Air, Inc. 33

Prisons 34 Ramsey County Prison St Paul, MN Pictures Courtesy of Genesis Air, Inc.

35 Helping Hands for Humanity Animal Shelter Topeka, KA Pictures Courtesy of Genesis Air, Inc. 35

Federal 36 Laughlin AFB Fuel Maintenance Hanger & PT Building FLETC & Command Building Fort Sam Houston Corp of Engineers Regional Offices & Dorm 1001 Goodfellow AFB School Age Facility & Pipeline Dormitory 36 Pictures Courtesy of Genesis Air, Inc.