Neutron Imaging and Tomography with MCPs

Slides:



Advertisements
Similar presentations
Area Detectors Like film can detect position Like scintillation detector can measure intensity With modern computers can assign hkl from unaligned crystal.
Advertisements

The Factors that Limit Time Resolution in Photodetectors, Workshop, University of Chicago, April 2011 What is known experimentally about timing determinants.
Preliminary Performance Measurements for Streak Camera with Large-Format Direct-Coupled CCD Readout* 15th Topical Conference on High-Temperature Plasma.
Optical image tube with Medipix readout
Hardware Progress Doug Abernathy ARCS Instrument Scientist ARCS IDT Meeting Lujan Center, LANL September 30, 2002 SNS Instrument SystemsArgonne/Oak Ridge.
Photon Counting Sensors for Future Missions
9th IWoRiD: Erlangen,July 2007, John Vallerga High resolution UV, Alpha and Neutron Imaging with the Timepix CMOS readout J. Vallerga, J. McPhate, A. Tremsin.
Space Astronomy: The UV window to the Universe, El Escorial, May 2007, John Vallerga The current and future capabilities of MCP based UV detectors J. Vallerga,
Medipix2 meeting Dec Medipix Activity at Berkeley John Vallerga, Jason McPhate, Anton Tremsin and Bettina Mikulec.
Neutron Generation and Detection Lee Robertson Instrument & Source Division Oak Ridge National Laboratory 17 th National School on Neutron and X-ray Scattering.
ALD 20µm Microchannel Plates
RF background, analysis of MTA data & implications for MICE Rikard Sandström, Geneva University MICE Collaboration Meeting – Analysis session, October.
Dott. Dario Tresoldi CNR IPCF ME
Detecting Electrons: CCD vs Film Practical CryoEM Course July 26, 2005 Christopher Booth.
Institute for Safety Research Dávid Légrády IP-EUROTRANS ITC2 Development of a Neutron Time-of-Flight Source at the ELBE Accelerator ELBE Neutron source.
Xiaodong Wang ( 王晓冬 ) School of Nuclear Science and Technology Lanzhou University, Lanzhou, China MPGD activities at Lanzhou University July 5, 2013.
ITAM CAS, IEAP CTU IWORID 2004Glasgow, th July IWORID 2004 OPTIMIZATION OF X ‑ RAY DYNAMIC DEFECTOSCOPY USING MEDIPIX-2 FOR HIGH FRAME RATE READ-OUT.
K.-F. Pfeiffer, PI4 Universität Erlangen-Nürnberg 1 IWORID 4, September 2002 Large scale x-ray images taken with the Medipix1 chip Karl-Friedrich Pfeiffer.
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
Measurement Results Detector concept works! Flood fields show MCP fixed pattern noise that divides out Spatial resolution consistent with theory (Nyqvist.
LOGO ภาควิชาอิเล็กทรอนิกส์ คณะวิศวกรรมศาสตร์ สถาบันเทคโนโลยีพระจอมเกล้าเจ้าคุณทหารลาดกระบัง.
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003 July 21, 2003 revised August 1, 2003 updated.
High resolution X-ray analysis of a proximal human femur with synchrotron radiation and an innovative linear detector M.Bettuzzi, R. Brancaccio, F.Casali,
The detection of single electrons using the MediPix2/Micromegas assembly as direct pixel segmented anode NIKHEF: A. Fornaini, H. van der Graaf, P. Kluit,
Cross-sections of Neutron Threshold Reactions Studied by Activation Method Nuclear Physics Institute, Academy of Sciences of Czech Republic Department.
Tests of AWAKE spectrometer screen and camera at PHIN Introduction Layout Procedure Setup, results (runs 1 – 5) Conclusions L. Deacon, S. Mazzoni, B. Biskup.
1 Wojciech Dulinski Pixel 2000, Genova, Italy Pixel Sensors for Single Photon Detection Contents - Idea and basic architecture.
Institute of Experimental and Applied Physics Czech Technical University in Prague IEAP – CTU Prague 1 Current status and future development of neutron.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
Space Sciences Laboratory, University of California, Berkeley SSL-UCB, ALD MCP Test Progress ML201-B-2 12nm ALD After cleaning ML201-B-1 6nm ALD.
Understanding mass transport in fuel cells using neutron imaging
High-energy background at the Cold Neutron Chopper Spectrometer at the SNS Georg Ehlers Quantum Condensed Matter Division Oak Ridge National Laboratory.
33mm MCP Testing at UC Berkeley
Overview of MCP requirements: resistive layer and SEE A. S. Tremsin, O. H. W. Siegmund Space Sciences Laboratory University of California at Berkeley Berkeley,
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
METAL DETECTORS: PERFORMANCES AND APPLICATIONS Oleksandr Okhrimenko Institute for Nuclear Research NAS of Ukraine, Kiev.
PSA: ADAPTIVE GRID SEARCH The Method Experimental Results Optimization aspects Roberto Venturelli (INFN Padova - IPSIA “Giorgi” Verona) SACLAY, 05-may-06.
MCP Testing Using Square Conductive Pads as Readout Anode Sagar Setru 1/19/2014.
PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements:  Expected total rate for 9.25 < R < 120 cm: 12.1 MHz:
DESCRIPTION OF PIXIRAD  The PIXIRAD Imaging Counter is an INFN-Pisa Spin-off  It works in photon counting  Pulse discrimination with two thresholds.
Institute of Experimental and Applied Physics Czech Technical University in Prague IEAP – CTU Prague 1 BrightnESS T4.1 Meeting Activity at IEAP CTU in.
Precision Drift Tube Detectors for High Counting Rates O. Kortner, H. Kroha, F. Legger, R. Richter Max-Planck-Institut für Physik, Munich, Germany A. Engl,
TPC for ILC and application to Fast Neutron Imaging L. An 2, D. Attié 1, Y. Chen 2, P. Colas 1, M. Riallot 1, H. Shen 2, W. Wang 1,2, X. Wang 2, C. Zhang.
DEVELOPMENT OF PIXELLATED SEMICONDUCTOR DETECTORS FOR NEUTRON DETECTION Prof. Christer Fröjdh Mid Sweden University.
Development of a High Resolution Position Sensitive MCP-PMT detector
IFR Detector R&D status
Positron emission tomography without image reconstruction
Modeling microchannel plate detectors for improved performance
Neutron Imaging with a Novel Position-Sensitive MCP detector
Akhmatov Z.A1, Khokonov A.Kh1,2, Masaev M.B1, Romanenko V.S1.
Background simulations: update and simulations of absorbed dose
A 3D design model of the apparatus for the Laser Wakefield Acceleration of electrons at ELI-NP S. Balascuta1 , R. Dinca1 1) “Horia Hulubei” National.
Present Read Out Chain for the PANDA Barrel DIRC
Sensitivity of Hybrid Resistive Plate Chambers to Low-Energy Neutrons
A. Zhang, S. Colafranceschi, M. Hohlmann
Gamma-ray Large Area Space Telescope ACD Final Performance
DESY contributions to MAPS DESY testbeam
Testing and Calibration at IHEP for eXTP (current plans and needed facilities) YuSa Wang
Neutron detectors for the NMX instrument
Upgrade of LXe gamma-ray detector in MEG experiment
The Pixel Hybrid Photon Detectors of the LHCb RICH
Upgrade of LXe gamma-ray detector in MEG experiment
Heritage from the LOFT-M3 study: Collimator Assembly
Mentor: Chris Kenney 12 August 2010
Overview of the Low Energy Telescope and its Performance in-orbit
UCB Progress with 8” MCPs and Testing
A. Zhang, S. Colafranceschi, M. Hohlmann
Arradiance ALD/Incom MCP Test
Beam Test Results for the CMS Forward Pixel Detector
Presentation transcript:

Neutron Imaging and Tomography with MCPs 12/02/2018 Neutron Imaging and Tomography with MCPs Serge Duarte Pinto 4 July 2017 iWoRiD - Krakow test

Neutron Imaging simplified setup Bright field imaging most conventional Tomography possible with a rotating sample stage L/D of a beamline often limits spatial resolution to ℓ×L/D Scintillator/mirror/camera detector trades off resolution with detection efficiency Detector (thermal or cold) Moderator Neutron source Collimator Sample ? Mirror D L ℓ PHOTONIS footer content here

Neutron Imaging vs X-ray imaging Difference in contrast: X-rays interact with electrons, neutrons with nuclei X-ray cross-section increases steeply with Z, neutron cross-section less predictable, and depends on isotope Source: PSI PHOTONIS footer content here

Microchannel Plates loaded with ¹⁰B and Gd Glass capillary structures with millions of microscopic pores, each of which acts as an electron multiplier Can be made in almost any size and shape If the glass is doped with 10B and Gd, it becomes neutron sensitive Detection efficiency ~50% for thermal neutrons (~70% cold) PHOTONIS footer content here PHOTONIS CONFIDENTIAL

Neutron-sensitive phosphor screen imager An assembly of one or more MCPs with a phosphor screen Mounted in a vacuum enclosure, screen observed through a viewport by a camera 2 MCPs high gain, wider PSF 1 MCP lower gain First tests with 40 mm round FoV 100x100 mm2 unit in progress PHOTONIS footer content here

Neutron-sensitive phosphor screen imager Tested in February at the Reactor Institute Delft (NL) with thermal neutrons, and in March at HFIR, Oak Ridge National Lab with cold neutrons. PHOTONIS footer content here

Taking Images and processing them Raw images are taken until sufficient exposure Background subtracted from the average raw image Normalization with open beam image Background Open beam Raw images (x200) Average Bkg subtracted Normalized image PHOTONIS footer content here

Gadolinium test mask Made at PSI: C. Grünzweig et al., Rev. Sci. Instrum., vol. 78, no. 5, p. 53708, May 2007. PHOTONIS footer content here

Gadolinium test mask Resolution line grid can be used to calculate modulation transfer function (MTF) curve Limiting resolution is often defined @ 10% or 5% MTF This means 10-12 lp/mm, or 80-100 µm for our imager PHOTONIS footer content here

Gadolinium test mask 2D FFT The square line grid can reveal pincushion or barrel distortions. A 2D Fourier transform is particularly sensitive to such distortion. 2D FFT PHOTONIS footer content here

Tomography Threshold: 0.5 cm¯¹ Test sample from: A.P. Kaestner et al., Phys. Proc. 43 (2013) 128–137. Tomography of multimetal sample 900 projections in <2 hours Shadows due to uncorrected beam hardening  By adjusting the attenuation coefficient threshold metals can be in- or excluded Pb Ti Cu Fe Al Ni Threshold: 0.5 cm¯¹ PHOTONIS footer content here

Some more images PHOTONIS footer content here

Thermal vs cold neutrons Thermal Cold Thermal neutrons: more penetration Cold neutrons: more contrast Images of a Planacon MCP-PMT made in Delft (thermal) and ORNL (cold). PHOTONIS footer content here

Improved design 100x100 mm² active area A single MCP for better resolution MCP electroding and spacing to phosphor better optimized for resolution Services (pumps, gauges, high voltage etc.) integrated in one control box All aluminum housing (low activation) Square active area means cylindrical FoV for tomography Need a hi-res camera to reach a better resolution Beam time scheduled at HFIR (ORNL) in September PHOTONIS footer content here

Conclusions & outlook A neutron imaging detector that does not trade off resolution with detection efficiency Resolution so far: ~100 µm, we know how to improve to <50 µm Detection efficiency ~2 orders of magnitude better than scintillators of comparable resolution Strongly reduces exposure time for low-contrast samples, and especially for tomography Time resolution limited by the camera Imaging with portable sources within reach PHOTONIS footer content here

PHOTONIS Technologies S. A. S PHOTONIS Technologies S.A.S. 18 Avenue de Pythagore CS 70019 33693 MERIGNAC Cedex France T +33 (0)556 16 40 50 F +33 (0)556 16 40 62 www.photonis.com PHOTONIS footer content here

Neutron imaging & counting Timepix chip readout instead of phosphor screen Each neutron hit fires multiple neighboring pixels Centroiding of these multipixel events allows a 15 µm resolution Time resolution of ~1 ns (energy-resolved imaging) FoV limited by chip size and shape Rate capability limited by chip data rate 3 kHz magnetic field imaging 2.02 Å 3 Å 3.9 Å This detector is developed by Anton Tremsin et al., and these images are from his presentations and publications. PHOTONIS footer content here 4.87 Å 5.77 Å 6.67 Å