Maria’s Restaurant Lesson 17 Appendix A Zone 1 Equipment Loads

Slides:



Advertisements
Similar presentations
Creating a functional, aesthetic service area
Advertisements

Barracks Safety.
ENERGY STAR Multifamily High Rise Program
Kitchen Corps, Inc. Putting the pieces back together!
1 October 21, 2014 The Safe Use of Taps. 2 October 21, 2014 What are RPTs?  A Re-locatable Power Tap (RTP) or power strip, is used to provide multiple.
Electricity Calculating Electric Power When installing new appliances, equipment, tools, or any type of electrical convenience, it is important to know.
World Learning Service Diagram Tegan Bissell. Service Line Deli Bar Hot Gluten Free mealServe yourself (4-6 items) Dishwashing Station Main Production.
Power and Electricity Cost Physics. Electric Power The proportional rate of the amount of current being sent through a circuit to the amount of voltage.
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
Ductless Heat Pumps Sizing Example
Announcements Midterm Project Prepare groups of 3 to 4 students You can submit the list at the end of next class Midterm Exam 03/09/10 - In class Exam:
Planning Back- of-House Support Areas Chapter 4 (c) 2014 by John Wiley & Sons, Inc.
Physics Day 23 Aim: How much power does a toaster use? LO: Calculate power use for V, I and R LO: Calculate energy use from power LO: Kilowatt-hour is.
Objectives Finish residential electrical systems Solve some example Compare electrical systems for residential and commercial building.
Calculating Electricity
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Objectives Analyze processes in AHU and buildings.
INTRODUCTION TO HEAT LOAD HEAT LOAD12 3 TOPICS COVERED INTRODUCTION DESIGN CONSIDERATIONS DEFINITIONS/CONCE PT/FORMULA THE FORM LOAD COMPONENTS –External.
Ch th hour Refrigerators and Freezers In most kitchens, the largest appliance Is the refrigerator. The freezer section may be at the top, at the.
Lesson Measuring and Calculating Electricity. Interest Approach § Have you or your parents ever been using several appliances in the kitchen and had a.
 No cheating…………… Watts 1440Watts 1200 Watts 1100 Watts 300 Watts.
VRF Applications in PNW RTF RTUG Meeting October 26, 2011 Kevin Campbell Reid Hart, PE Technical Research Group.
Electricity Calculating Electric Power This lesson is from Virginia Tech and has not been edited by the Georgia Curriculum Office.
Planning Electrical Circuits Original by Ryan Talton Modified by Georgia Agriculture Education Curriculum Office –June 2004.
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Ohm’s Law and Power ELPT 1311 Basic Electrical Theory Chapter 04_Ohm’s Law Introduction to Electricity by Paynter & Boydell and Pearson Illustrations.
26’ Mobile Kitchen. 26’ Catering Kitchen Trailer In stock and ready for delivery. Trailer details/features General Features: Aluminum diamond plate.
SECTION 7 AIR CONDITIONING (COOLING) UNIT 35 COMFORT AND PSYCHROMETRICS.
Maria’s Restaurant Chapter 1 Section 1
Maria’s Restaurant Chapter 2 Section 6
Maria’s Restaurant Chapter 2 Section 9
Maria’s Restaurant Lesson 20 Appendix B Zone 2 Manual N Loads
Maria’s Restaurant Lesson 18 Appendix A Zone 2 Equipment Loads
Maria’s Restaurant Lesson 21 Appendix C Duct Design
Maria’s Restaurant Chapter 2 Section 7
Maria’s Restaurant Appendix A Section 16 HVAC Building Loads
Planning Electrical Circuits
Welcome to the Colorado Restaurant Association Pikes Peak Chapter Energy Efficiency in the Restaurant Industry.
Maria’s Restaurant Chapter 1 Section 3
Maria’s Restaurant Chapter 3 Section 13
Lesson 24 Appendix F Outside Air Calculation
Maria’s Restaurant Chapter 1 Section 5
Fully Equipped Restaurant for Lease
Maria’s Restaurant Chapter 1 Section 2
Lesson 23 Appendix C Exhaust Calculation
Maria’s Restaurant Chapter 2 Section 8
Planning Electrical Circuits
Business, Building and Liquor License for sale Offered at $1,795,000
Maria’s Restaurant Chapter 4 Section 14
Kitchen Equipment Chapter 5.
Flip The Long House Let’s imagine the Long house example in Manual J has undergone a house flipping/energy savings update. The insulation was increased,
Adding Zones to Existing Systems
Zoning Load Calculations
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Zoning Methods There are an unlimited number of ways to zone a home! Popular ways include: More than one single zone HVAC system. Zone damper systems.
Mandatory Design Requirements
The heating effect of an electric current
Objectives Finish with Practice circuits problems for
Electric Power.
Objective Revie the Cooling Cycle Learn about air distribution systems
Maria’s Restaurant Chapter 1 Section 3
Maria’s Restaurant Chapter 2 Section 7
Maria’s Restaurant Chapter 2 Section 9
Maria’s Restaurant Lesson 22 Appendix C Zone 2 Duct Design
Maria’s Restaurant Lesson 20 Appendix B Zone 2 Manual N Loads
Maria’s Restaurant Chapter 2 Section 8
Lesson 24 Appendix F Outside Air Calculation
Maria’s Restaurant Chapter 1 Section 5
Maria’s Restaurant Chapter 1 Section 2
Presentation transcript:

Maria’s Restaurant Lesson 17 Appendix A Zone 1 Equipment Loads

Maria’s Restaurant Maria’s

Maria’s Restaurant Design (Staff: Maria & 6 Employees each shift. Glass Store Front and front door) C1 R1 F1 Woman’s Restroom 1 handicap 1 standard Men’s Restroom 1 handicap 1 urinal Shelv.. R3 S3 DW Bar 12 X 10 Seating 12 Counter C6 Bar S2 B2 Ice R4 Shelving/Storage 25 ft. Shelv. B1 C7 C2 Fry S1 Restaurant 33 X 15 11 X 4 & 11 X 6 Seating 58 CT/O C3 SP ZONE 1 SK H1 R2 F2 WH S1 66 ft. B = Beverage Area R = Refrigerator (blue walk in C = Counter S = Sink; S1 Hand; S2 3 Pot; S3 Bar CT = 4 burner plus flat top over ovens SK= Steam Kettle DW = Dishwasher SP = Salad/cold Prep table F = Freezer (blue walk in) H1 = Hot Prep Table with Heat Lamp Shelf

Zone 1 Restaurant & Bar Area Equipment For Maria’s Restaurant, the Restaurant and Bar area equipment’s total Btuh value is: 22,186 Btuh The following presentation shows how the total Btuh was calculated for each piece of equipment shown on the drawing, and then added to some small appliances and restaurant equipment not shown on the drawing Maria has specified electrical circuits for.

Bar Refrigerator Manual N Table 6E Refrigerator 5 to 25 Cu. ft. per 10 Cuft of space 1,670 Rated at 23.8 Cu. ft. 23.8 ÷ 10 = 2.38 Thus; 2.38 x 1,670 = 3,975

Beer Keg Refrigerator Manual N Table 6E Refrigerator 5 to 25 Cuft: per 10 Cuft of space 1,670 Rated at 19.8 Cuft; 1.98 x 1,670 = 3,307

Refrigerator Cubic Foot to Btuh 1 Find Btuh for a 24 Cu. ft. refrigerator. Manual N Table 6E Refrigerator 5 to 25 Cu. ft. per 10 Cu. ft. of space 1,670 (24 ÷ 10) × 1,670 = 4,008 Btuh

Refrigerator Cubic Foot to Btuh 2 Find Btuh for a 24 Cu. ft. refrigerator. Manual N Table 6E Refrigerator 5 to 25 Cu. ft. per 10 Cu. ft. of space 1,670 (6 ÷ 10) × 1,670 = 1,002 Btuh

Bar Icemaker Manual N Table 6E Ice Maker 110 lb per day sensible no hood; 6,420 Btuh Approximate: 65 ÷ 110 X 6,420 = 3,794 Btuh

2-308 lb Ice Makers/ Drink Servers (Remote Condenser Air Cooled) No appreciable Btuh Dimensions W X D X H 22 X 24 x 24

Some Other Small Electronic Equipment Manual N Table 6 C, All without hood in Btuh: (sensible + latent where applicable) 2 Cash Registers = 400 Btuh 1 Small Desktop Printer Idle = 35 Watts (119 Btuh) 1 Desktop Copier Idle = 20 Watts (68 Btuh) 9 Customer computers/devices = 495 watts 1,689 Btuh (Continuous Usage/ Customers) Total Small Appliance in Bar Load = 2,276 Btuh Note: Watts X 3.412 = Btuh

Watts to Btuh How many Btuh will be equivalent to six 300 watt incandescent light bulbs? Watts = 6 × 300 = 1,800 Watts × 3.412 = Btuh Btuh = 1,800 × 3.412 = 6,142 Btuh

Amps & Volts to Watts & Btuh 1 For single-phase equipment: Watts = Amps × Power Factor × Voltage Find the Watts for a 10 h.p. single phase motor operating at 230 Volts and 50 amps (use PF of 0.85) Watts = 50 × 0.85 × 230 = 9,775 Btuh

Amps & Volts to Watts & Btuh 2 For three-phase equipment: Watts = Amps × Power Factor × Voltage × 1.732 Find the Watts for a 10 h.p. 3 phase motor operating at 460V and 14 amps (use PF of .85) Watts = Amps × Power Factor × Voltage × 1.732 Watts = 14 × 0.85 × 460 × 1.732 = 9,480 Watts

Some Other Small Food Equipment (Bar Area) Manual N Table 6, All without hood in Btuh: (sensible + latent where applicable) 2 Coffee Brewers 12 cup 2 Burners (6E) = 2 X (1,910 + 1,810) = 7,440 Btuh Food Processor 2-3 Qt (6E) = 1,770 Btuh Blender 2-6 Qt (6E) = 1,000 + 500 = 1,500Btuh Total Bar Small Appliance Load = 5530 + 5180 Btuh (10,710 Btuh)

Total Bar/Entrance Equipment Load (Zone 1) Refrigeration: 3,975 Btuh Refrigeration: 3,307 Btuh Ice Making: 3,794 Btuh Small Appl.: 5,530 + 5180 10,710 Btuh Small Electronic Appliances: 2,276 Btuh Total: 24,062 Btuh Total latent Load: 5,530 Btuh

Lighting Specifications ASHRAE 90.1 2010 Zone 1 Dinning & Bar Wattage per ft2 = 0.90 1,117 ft2 X 0.90 = 1,005 Watts Note: 1,005 Watts X 3.412 = 3429 Btuh

Zone 1 Manual N

Internal Loads

Zone 1 Load Summary

Zone 1 Load Summary Denver

Field Notes Unfortunately, most building owners do not consider the HVAC system when they remodel. It is not unusual to find thermostats/sensors in sections they do not control, or up in ceilings shoved out of site. The technician was called out because the employee kitchen was too hot year round. The building had a variable air volume system (VAV) with reheats for the perimeter areas. The kitchen was in an internal area so it was always supplied with air that was 65F (in the winter) or cooler (55F in the summer). The technician noted the kitchen was fairly new and that a controlling thermostat/sensor was not present in the room. Since the kitchen was added without considering the HVAC system: the recommendation was for a load calculation to be done based on the newly added kitchen equipment, and that the kitchen area be made into a separate zone on the VAV system, with its own control. This change would require moving a thermostat/sensor and a duct modification, along with an air balance for two VAVs.