Graz University of Technology May 11th – 12th Maribor, Slovenia

Slides:



Advertisements
Similar presentations
International Telecommunication Union ITU-T Study Group 5 The need for special requirements Tetsuya Tominaga Technical Session on Home Networks Geneva,
Advertisements

Standards for the protection of radio installations
Earthing systems, Harmonics Currents and GFP
Earthing systems, Harmonics Currents and GFP
1 CNS/GSS/2008/M1 1 Module 1 Basic Terminologies and Characteristics of Switchgear.
Committed to connecting the world Ninth ITU Symposium on ICTs, the Environment and Climate Change Kochi, India, 15 December 2014 Damage prevention and.
Bonding Requirements For Gas Piping Systems Bob Torbin October 2007
EE4503 Electrical Systems Design
Inspection & Test Overview suite412.
Designing a EMC Compatible Electronic Meter using AD7755 a.
Protection against Lightning Overvoltages Overvoltages due to lightning strokes can be avoided or minimized in practice by (d) shielding the overhead lines.
“Equipment bonding jumpers: are they always necessary?” Massimo Mitolo, Senior Member, IEEE.
How to efficiently use the electrical distribution underground cables for Power Line Communications and to achieve the Smart grid’s goals. Energy Smart.
Electrical Earthing D.K.Pathirana. Applications of earthing Protect human against lightning and earth fault condition Protect the premises against lightning.
Impact of Bonding Requirements for CSST on LP-Gas Piping Systems April 2009.
Overvoltage Protection, A. Zeddam, Dakar, Senegal, 25 March 2015 ITU Regional Standardization Forum For Africa Dakar, Senegal, March 2015 Overview.
1 EXPERIENCE AND RELIABILITY. 2 Short circuit loop measurements EN EN
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
Overview of ITU-T Study Group 5 “Environment and Climate Change” Cristina Bueti, Adviser, ITU.
F. Ferrandis_SP_ALPHA 2_BLOCK 2_Paper 35_Presentation Barcelona May POWER FACTOR CORRECTION WITHIN INDUSTRIAL SITES EXPERIENCES REGARDING.
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
Domestic Natural Gas Installations Marc Billington.
1 Technical requirements on electrical goods for low voltage NV č. 17/2003 Sb. Dir. 2006/95/ES General requirements General requirements Goods or documentation.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
SWER New Zealand & Australian Experience
Wiring and Grounding.
Integrated Grounding, Equipotential Bonding and Lightning Protection in Smart Grids and Smart Buildings – A Multi-Faced Approach Ladies and gentlemen,
Gandhinagar Institute of Technology
Assumption University Thailand EE4503 Electrical Systems Design Main Circuit 1.
Etienne CARLIER, LBDS Audit, 28/01/2008 LBDS Environmental Aspects EMC, radiation, UPS… Etienne CARLIER AB/BT/EC.
Advanced Science and Technology Letters Vol.47 (Architecture and Civil Engineering 2014), pp Electromagnetic.
A common 400 Hz AC Power Supply Distribution System for CMS FEE. Authors C. Rivetta– Fermilab. F. Arteche, F. Szoncso, - CERN.
UNDERGROUND CABLE.
Electrical Installation II1 Assessment of General Characteristics (Note: All the mentioned tables in this course refer to, unless otherwise specified,
Institute of Electrical Power Systems Institute of High Voltage Engineering and Systemmanagement NEW WAYS TO INTEGRATE GROUNDING, EQUIPOTENTIAL BONDING,
ITU Symposium on ICTs, the Environment and Climate Change Kuala Lumpur, Malaysia 21 April 2016 Session2: Damage prevention and safety Resistibility of.
ESS Grounding System Concept Fundamentals and Requirements
Developing Cabling Module Situation at August 2006 Vello Vanem.
ALARA IMPLEMENTATION AT UKRAINIAN NPPs T. Lisova, Nuclear Energy Department, Ministry of Fuel and Energy of Ukraine Y. Roshchyn, National Nuclear Energy.
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
F. Arteche EMC: Electronics system integration for HEP experiments (Grounding & Shielding)
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Committed to connecting the world Overview of ITU-T SG5 Work on Damage protection and safety Guy-Michel KOUAKOU Chairman of Study Group 5 Regional Group.
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
IEEE NPEC SC2 Equipment Qualification Electromagnetic Compatibility Compliance Type Test-Design Considerations- Installation and Mitigation Standard/Guidance.
High Voltage Engineering
Radio Base Stations Sited on Power Line Towers
PROTECTION AGAINST INDIRECT CONTACT
PES 1000 – Physics in Everyday Life
Quality and Security Assessment of Protection Systems
Transposition of European Network Codes
IG BASED WINDFARMS USING STATCOM
Grounding And Safety Techniques Ms. Tahoora Qureshi, Asst. Professor
High Voltage Engineering
Smitty’s Two Minute Drills
HIGH VOLTAGE ENGINEERING (HVE)
WELCOME TO ALL.
EARTHING.
PV System Quality and Performance
Design of Electric Power Systems and Utilities
Govt. Polytechnic,Manesar
Optimization of the Energy-Supply-Structure of modern Aircraft by using conventional power system technologies Dipl.-Ing. Ilir Purellku Electrical Power.
EHV Transmission Equipments
Low Frequency Magnetic Fields...
EET 323 – Electrical System Design Lecture 9: Grounding
Protection against over voltages
Safety Meeting Topics Standby Generator Safety
1-2 Grounding Principles and CF Infrastructure in Instruments Halls
Grounding Myths.
Presentation transcript:

Graz University of Technology May 11th – 12th Maribor, Slovenia New Ways to Integrate Grounding, Equipotential Bonding, Shielding and Lightning Protection Coordinated proposals as the basis for a successful installation and safe operation of electronic equipment such as smart meters, load and energy control modules in Smart Buildings and Smart Grids in low voltage distribution networks Dipl.-Ing. Dr. Ernst SCHMAUTZER Institute of Electrical Power Systems (schmautzer@tugraz.at) a.o. Univ.-Prof. Dipl.-Ing. Dr. Stephan PACK Institute of High Voltage Engineering and System Management (pack@tugraz.at) Graz University of Technology May 11th – 12th Maribor, Slovenia

Earthing, Equipotential Bonding, Lightning Protection and Shielding The basis are the requirements to ensure - the protection measures against electric shock, - protection measures for objects, areas, space, electronic equipment, - safety of people and property - EMC - the safe and reliable operation of electronic equipment - external and internal lightning protection, - structural requirements, grounding, equipotential bonding system, utilization of existing or planned on-site metallic components and structures such as metal facades, concrete reinforcing steel, metal cases, … Focus on the the integration of - earthing, - equipotential bonding, - shielding, - and lightning protection Considering State of the Art, State of Science - relevant standards, experiences and research

Earthing, Equipotential Bonding, Lightning Protection and Shielding Premises - These topics are considered mostly separately in the planning, implementation, coordination, examination and operation process - Practice shows that a multitude of problems appear caused by stray-currents, unwanted interfering electromagnetic fields, inductive influences by low-frequency and transient currents, disturbing effects due to - switching operations in the network or as a result of - atmospheric discharges - And so integration and coordination is necessary

Earthing, Equipotential Bonding, Lightning Protection and Shielding Premises - Other than in the most European countries, where the observation of standards is voluntary, in Austria, based on the Electrotechnical Law 1992 ETG and in the Electrical Engineering Regulation ETV 2002 (2006) certain safety standards have to be obeyed mandatorily by the planners, builders and operators of electrical installations by law One problem of this regulated approach is, that most of the planners, builders and operators consider only the legally obligatory safety standards (representing only the minimal safety requirements) and the state of art, the state of science and other relevant standards, rules and knowledge originated from the practice, going beyond the requirements of obligatory standards, are not taken into account In other European countries the situation is not much better - everywhere planners and owners submit to the cost pressure and attempt to follow a minimalistic approach where a minimum of technological standard is pursued

Earthing, Equipotential Bonding, Lightning Protection and Shielding Solution Integrated planning, implementation and operation phases of a coordinated grounding system for equipotential bonding and lightning protection realizing a system with low impedance (low- and high frequency) State of the Art State of Science State of the Art State of Science Planning phase Concept, planning and requirements for concrete- footing grounding systems, protection against electric shock, TT-, TNS-, IT-system, equipotential bonding, lightning protection, EMF, EMC, IEC 60364, ÖVE E8001-1, ÖVE E8383, ÖVE E8014, ÖVE E8049, EN 62305, EN 50310, EN 50341, EN 61347-1, EN 50164, EN 50172, EN 50173, EN 50174,... Coordination with the protection system against electric shock Coordination of grounding systems, concrete-footing grounding system, vertical and horizontal grounding systems, isolated base plates, equipotential bonding systems and measures Combined use of grounding, equipotential bonding, shielding and lightning protection equipment under consideration of operational and transient frequencies (grounding resistance / impedance), narrow meshed-grid grounding systems to distribute the currents and to realise a low impedance of the grounding system Consideration of resistive and inductive interference Inclusion of concrete (building) armouring Utilization of synergy effects, avoidance of redundancy Planning of verifiability and check-intervals Guidelines for grounding, equipotential bonding and ICT, EN 50174 Multiple connections, meshed (or radiating) grounding and bonding system, HD 60364-4-444, ÖVE E8001-1/A4, star-point-connection SVL Star-point-connection scheme or narrow meshed grounding and equipotential system

Earthing, Equipotential Bonding, Lightning Protection and Shielding Solution Integrated planning, implementation and operation phases of a coordinated grounding system for equipotential bonding and lightning protection realizing a system with low impedance (low- and high frequency) State of the Art State of Science State of the Art State of Science Planning phase Planning of a combined and coordinated meshed equipotential system (CBN) in single or complex buildings, EN 50310, ÖVE E8001-1/A4, ÖVE E8001-1/A5, EN 50174-2, EN 62305, ... Combination grounding and equipotential bonding system in all levels, combination with the lightning protection system, observation of the separation distance Efficient (narrow) intermeshing of grounding, bonding and lightning protection system Utilization of natural parts of the building (armouring and other conductive parts) Equipotential bonding and PE with sufficient profile Grounding points in suitable distances Generic ICT-cabling, EN 50173, EN 50174, EN 50098-1, ... Consideration of nonlinear load-flow, ÖVE E8001- 1, EN 50174, EN 61800-5... TNS- or IT-system in buildings or building complexes, EN 50310, ÖVE E 8001-1, (pr)HD 60364-4-444 Location of equipotential bonding and PE-conductors Concept for shielding and equipotential bonding, treatment of shielding systems, by-pass conductor for screen reinforcement, EN 50173, EN 50174 Compensation conductors Cables and metallic pipes shall enter the system at the same place (single point entry) Fish-trap like equipotential bonding and armouring Protection against direct and indirect lightning effects, ÖVE E8001-1, ÖVE E8383, ÖVE E8049, EN 62305 Lightning protection zones EMC protection zones 2- and 3-dimensional meshing of systems Single-point-entry principle

Earthing, Equipotential Bonding, Lightning Protection and Shielding Solution Integrated planning, implementation and operation phases of a coordinated grounding system for equipotential bonding and lightning protection realizing a system with low impedance (low- and high frequency) State of the Art State of Science State of the Art State of Science Planning phase Measures against operating and transient overvoltages, protection of buildings, facilities and appliances, protection zones, ÖVE E8001-1/A3, EN 50310, EN62305, EN 61000 Series Distributed complex buildings Coordinated surge protection systems Dimensioning of equipotential bonding, PE- and grounding conductors, ÖVE E 8001-1/A5 Sufficient dimensioning of conductors based on operating and fault conditions considering lightning and transient effects Implementation phase General safety requirements, use of metallic conductors or fibre optics, screen treatment, symmetrical or asymmetrical operation of ICT- systems, EN 50173, EN 50174, EN 50098-1, -2, ... Implementation of reliable connections taking into account the expected operating and transient frequencies Compliance with the general installation guidelines, E8001-1, EN 50310, EN 50174 Installation guidelines for low-impedant connections for low-and high-frequency Initial verification, documentation IEC 60364-6 Verification of ICT-cabling EN 50364 Verification of the lightning system ÖVE regulations, EN 62305 Operating phase Operation of electric installations EN 50110 Operation of electric, electronic and ICT-systems, quality management, administration, repair and maintenance, EN 50173, EN 50174 Periodic verification, documentation, IEC 60364-6 Periodic verification of the lightning protection system, EN 62305, ÖVE directives

Earthing, Equipotential Bonding, Lightning Protection and Shielding Solution Integrated planning, implementation and operation phases of a coordinated grounding system for equipotential bonding and lightning protection realizing a system with low impedance (low- and high frequency) State of the Art State of Science State of the Art State of Science Planning phase Measures against operating and transient overvoltages, protection of buildings, facilities and appliances, protection zones, ÖVE E8001-1/A3, EN 50310, EN62305, EN 61000 Series Distributed complex buildings Coordinated surge protection systems Dimensioning of equipotential bonding, PE- and grounding conductors, ÖVE E 8001-1/A5 Sufficient dimensioning of conductors based on operating and fault conditions considering lightning and transient effects Implementation phase General safety requirements, use of metallic conductors or fibre optics, screen treatment, symmetrical or asymmetrical operation of ICT- systems, EN 50173, EN 50174, EN 50098-1, -2, ... Implementation of reliable connections taking into account the expected operating and transient frequencies Compliance with the general installation guidelines, E8001-1, EN 50310, EN 50174 Installation guidelines for low-impedant connections for low-and high-frequency Initial verification, documentation IEC 60364-6 Verification of ICT-cabling EN 50364 Verification of the lightning system ÖVE regulations, EN 62305 Operating phase Operation of electric installations EN 50110 Operation of electric, electronic and ICT-systems, quality management, administration, repair and maintenance, EN 50173, EN 50174 Periodic verification, documentation, IEC 60364-6 Periodic verification of the lightning protection system, EN 62305, ÖVE directives

Proposal for a Practical Solution of Integration

Proposal for a Practical Solution of Integration

Proposal for a Practical Solution of Integration

Conclusion Only a holistic approach and implementation of the - earthing and equipotential bonding system - lightning protection system - EMC- and lightning protection-zones as a jointly co-ordinated system, taking into account - operational frequency (50 Hz) and transient frequency processes (short circuit, switching, lightning) provide a flexible operation and refurbishment meets the requirements for - protection against electric shock, - minimizes resistive, inductive and capacitive interference, - reduces the occurrence of electromagnetic fields and - enables the implementation of high-quality measures for the electric/electronic equipment safety, efficient lightning and surge protection.

Conclusion In designs with reinforced concrete or steel structures, metal roofs and metal cladding  the proposed grounding, equipotential bonding and lightning protection system can be integrated unobtrusively to achieve a reasonable protection goal - also in classical building concepts and refurbishment. The integrated of the protection system can (shall) be integrated into the innovative details of modern architecture and does not prejudice to the architectural design and technical function or provokes the need to modify the architectural concept If early enough considered  can be integrated easily in the design concepts of architecture

Graz University of Technology May 11th – 12th Maribor, Slovenia New Ways to Integrate Grounding, Equipotential Bonding, Shielding and Lightning Protection Coordinated proposals as the basis for a successful installation and safe operation of electronic equipment such as smart meters, load and energy control modules in Smart Buildings and Smart Grids in low voltage distribution networks Dipl.-Ing. Dr. Ernst SCHMAUTZER Institute of Electrical Power Systems (schmautzer@tugraz.at) a.o. Univ.-Prof. Dipl.-Ing. Dr. Stephan PACK Institute of High Voltage Engineering and System Management (pack@tugraz.at) Graz University of Technology May 11th – 12th Maribor, Slovenia