Budker INP V.Aulchenko1,2, L.Shekhtman1,2, V.Zhulanov1,2

Slides:



Advertisements
Similar presentations
Electronics for large LAr TPC’s F. Pietropaolo (ICARUS Collaboration) CRYODET Workshop LNGS, March 2006.
Advertisements

Bulk Micromegas Our Micromegas detectors are fabricated using the Bulk technology The fabrication consists in the lamination of a steel woven mesh and.
Front-end electronics for Time Projection Chamber I.Konorov Outlook:  TPC requirements  TPC readout options  Options for TPC FE chips  Prototype TPC.
New Readout Methods for LAr detectors P. Otyugova ETH Zurich, Telichenphysik CHIPP Workshop on Neutrino physics.
Large Area, High Speed Photo-detectors Readout Jean-Francois Genat + On behalf and with the help of Herve Grabas +, Samuel Meehan +, Eric Oberla +, Fukun.
TOF at 10ps with SiGe BJT Amplifiers
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
1 Digital Active Pixel Array (DAPA) for Vertex and Tracking Silicon Systems PROJECT G.Bashindzhagyan 1, N.Korotkova 1, R.Roeder 2, Chr.Schmidt 3, N.Sinev.
Chevron / Zigzag Pad Designs for Gas Trackers
Self triggered readout of GEM in CBM J. Saini VECC, Kolkata.
HallA/SBS – Front Tracker PARAMETERDESIGN VALUE Microstrip Silicon Detector Number of tiles/plane and size2 Number of planes2 Size of the single
Development of the Readout ASIC for Muon Chambers E. Atkin, I. Bulbalkov, A. Voronin, V. Ivanov, P. Ivanov, E. Malankin, D. Normanov, V. Samsonov, V. Shumikhin,
Studies of the possibility to use of a Gas Pixel Detector (GPD) as a fast track trigger device George Bashindzhagyan (Speaker,
Valerio Re, Massimo Manghisoni Università di Bergamo and INFN, Pavia, Italy Jim Hoff, Abderrezak Mekkaoui, Raymond Yarema Fermi National Accelerator Laboratory.
26 Apr 2009Paul Dauncey1 Digital ECAL: Lecture 2 Paul Dauncey Imperial College London.
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
HEXITEC ASIC – A Pixellated Readout Chip for CZT Detectors Lawrence Jones ASIC Design Group Science and Technology Facilities Council Rutherford Appleton.
Status of the n-XYTER testing Knut Solvag, Gerd Modzel, Christian Schmidt, Markus Höhl, Andrea Brogna, Ullrich Trunk, Hans-Kristian Soltveit CBM.
Readout Architecture for MuCh Introduction of MuCh Layout of Much ( proposed several schemes) Read ASIC’s Key features Basic Readout chain ROC Block Diagram.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
PPAC in ZDC for Trigger and Luminosity Edwin Norbeck University of Iowa Luminosity Workshop November 5, 2004.
MPI Semiconductor Laboratory, The XEUS Instrument Working Group, PNSensor The X-ray Evolving-Universe Spectroscopy (XEUS) mission is under study by the.
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
Gas detectors in a ZDC (at LHC) Edwin Norbeck and Yasar Onel University of Iowa For7 th CMS Heavy-Ion meeting at Delphi June 2003.
CBM 12 th Meeting, October 14-18, 2008, Dubna Present status of the first version of NIHAM TRD-FEE analogic CHIP Vasile Catanescu and Mihai Petrovici NIHAM.
FEE for Muon System (Range System) Status & Plans G.Alexeev on behalf of Dubna group Turin, 16 June, 2009.
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
NMLTA Protection System Update -Loss Monitors- Arden Warner September 2 nd, 2009.
SRS TIMING ANOMALY RD51 Mini-Week June 9, 2015 M. Phipps, BNL 1.
Gossip : Gaseous Pixels Els Koffeman (Nikhef/UvA) (Harry van der Graaf, Jan Timmermans, Jan Visschers, Maximilien Chefdeville, Vladimir Gromov, Ruud Kluit,
Page Detector and Electronics R&D for picosecond resolution, single photon detection and imaging J.S. MilnesPhotek Ltd T.M. ConneelyUniversity.
STT Detector risk’s assessment. STT detector work packages Straw Tubes modules Straw Tracker mechanics Front-End Electronics Analog electronics Digital.
GOSSIPO-3: Measurements on the Prototype of a Read- Out Pixel Chip for Micro- Pattern Gas Detectors André Kruth 1, Christoph Brezina 1, Sinan Celik 2,
A Low-noise Front-end ASIC design based on TOT technique for Read-out of Micro-Pattern Gas Detectors Huaishen Li, Na Wang, Wei Lai, Xiaoshan Jiang 1 State.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
The design of fast analog channels for the readout of strip detectors in the inner layers of the SuperB SVT 1 INFN Sezione di Pavia I Pavia, Italy.
High Energy Physics experiments.
Silicon microstrip detector for imaging of fast processes at high intensity synchrotron radiation beam. Budker INP V.Aulchenko1,2, L.Shekhtman1,2, B.Tolochko3,2,
A micropower readout ASIC for pixelated liquid Ar TPCs
Results achieved so far to improve the RPC rate capability
GEM, applications for SR experiments and tracking in HEP
Jan Soldat, Heidelberg University for the DSSC ASIC design groups
Application of VATAGP7 ASICs in the Silicon detectors for the central tracker (forward part) S. Khabarov, A. Makankin, N. Zamiatin, ,
X-ray CCD with low noise charge injection.
Dr: Mohamed Afifi By Lecturer Radiological Science
Shubin Liu, Binxiang Qi, Siyuan Ma, Zhongtao Shen, Guangyuan Yuan,
HV-MAPS Designs and Results I
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
A Low Power Readout ASIC for Time Projection Chambers in 65nm CMOS
The response function of semiconductor pixel detectors for highly ionizing particles Jan Jakubek, P. Soukup Institute of Experimental and Applied Physics,
Status of n-XYTER read-out chain at GSI
SiD Electronic Concepts
Ionization detectors ∆
HVCMOS Detectors – Overview
BESIII EMC electronics
MWPC’s, GEM’s or Micromegas for AD transfer and experimental lines
Chapter No. 10 General description of electronic units used in radiation measurements. viewpoint of ‘ input-output'-i.e., the input and output signals.
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
Pre-installation Tests of the LHCb Muon Chambers
AMICSA, June 2018 Leuven, Belgium
ME instrument and in-orbit performance
Readout Electronics for Pixel Sensors
Engineering Design Review
Readout electronics system for Laser TPC prototype
Readout Electronics for Pixel Sensors
Why silicon detectors? Main characteristics of silicon detectors:
Readout Electronics for Pixel Sensors
Presentation transcript:

A 64-channel integrated circuit for signal readout from coordinate detectors Budker INP V.Aulchenko1,2, L.Shekhtman1,2, V.Zhulanov1,2 Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia Novosibirsk State University, 630090, Novosibirsk, Russia Abstract A specialized integrated circuit is developed for the readout of signal from coordinate detectors of different types, including gas micro-pattern detectors and silicon micro-strip detectors. The ASIC includes 64 channels, each of those containing low-noise charge sensitive amplifier with connectable feedback capacitor and/or resistor and fast reset of the feedback capacitor. Each channel of the ASIC contains also 100 cells of the analogue memory that can be readout with 10 MHz rate through the analogue multiplexer. The pitch of input pads is 50 mm and the chip size is 5x5 mm2. Equivalent noise charge of the ASIC channel is about 2000 electrons with 10 pF capacitance at the input and maximal signal before saturation corresponds to 2x106 electrons. The first application for this ASIC is the detector for imaging if explosions at a synchrotron radiation beam (DIMEX), where it have to substitute old and slower APC128 ASIC. The full size electronics including 8 chips for 512 channels was assembled and tested. Detector DIMEX was developed in the Budker Institute of Nuclear Physics for the studies of materials performance at the conditions of extremal temperatures and pressures using SR beam [1]. The front-end electronics of the DIMEX is made on the basis of the APC128 ASIC [2], initially developed for high energy physics. APC128 contains 128 channels, each channel consisting of low noise integrator at the input and 32 analogue memory cells (Fig. 1). . Thus if a bunch is passing during the reset phase, the corresponding analogue memory cell would contain zero signal. In order to have full signal from one bunch recorded in one cell the bunch have to pass during the exposure phase and within a certain time window because of the signal dispersion due to leading edge of the integrator and longitudinal diffusion of electrons in the gas. In Fig. 7 cell 50 contains full signal when the clock delay is around 100 ns (125 ns detector cycle). At the same time next cell 51 does not contain any charge because bunches in the storage ring are arriving each 250 ns. The range of clock delay when full signal is collected in one cell is around 30 ns with 125 ns detector cycle. In case of 250 ns detector cycle this range is larger by 125 ns and thus we can be sure that full charge is collected by the integrator. Comparing the level of signal on plateau for 125 ns cycle and 250 ns cycle we can conclude that in the first case full signal is indeed collected. Fig.4. ENC of the registration channel as a function of the capacitance at the input measured at the 12 channel prototype DMXG12B. The new ASIC is appropriate not only for integrating X-ray detector but also for micro-pattern gaseous detectors that can be used for tracking of charged particles in particle physics experiments. Moderate gas amplification of several thousands can provide signal to noise ratio of more than hundred for noise of 3000 electrons. Such signal to noise ratio will be enough to get full efficiency for minimum ionizing particles and high spatial resolution below 100 μm. For operation in particle physics experiments with coordinate detectors with moderate occupancy, the resistor RG was introduced in the feedback of the input amplifier of the DMXG64. This resistor can discharge the feedback capacitor with time constant of several hundred nanoseconds that can provide safe operation of the ASIC with particle rate up to 100 kHz/channel (see Fig. 5). Fig.1. Block-diagram of the APC128 ASIC. Detector DIMEX was used in a series of unique experiments that resulted in a new data about the dynamics of structural evolution of several materials after shock loads [3]. At the same time the limitation of frame length at the level of 250 ns mainly due to slow input integrator which has signal settling time of 70-80 ns and slow reset switch of the integrator, does not allow to get more detailed information, that has principal importance in some cases. In order to avoid this limitation a new IC called DMXG64 is developed that has similar structure and operating algorithm as APC128, but allow minimum time gap of 100 ns between measurements., maximal signal in one channel up to ~2x106 electrons, equivalent noise charge (ENC) of the registration channel with connected strip readout structure does not exceed ~4x103 electrons that corresponds to statistical precision for the signal at 5% level of maximum. Besides that in order to increase the duration of data taking the depth of analogue memory in each channel is increased up to 100 cells (frames). Fig.7. Signal in one channel and two consecutive analogue memory cells as a function of time shift between the detector clock and the bunch passing moment. The VEPP-3 operates in one bunch mode (250 ns), the detector operates in two different regimes with 125 ns cycle and with 250 ns cycle. DIMEX is an ionization chamber filled with Xe-CO2(75%-25%) at 7 atm absolute (Fig.8). SR beam hits sensitive gas volume through 1 mm beryllium window in the gas box and is absorbed in the gap between the drift electrode and Gas Electron Multiplier (GEM) that serves as a Frisch grid. The GEM is operating in attenuation mode when electron flow is reduced due to limited GEM transparency. Electrons of primary ionization from the interaction gap are partly penetrate through the GEM and induce signals at the readout strip structure that consists of 512 strips with 100 μm pitch. The strip structure as well as the interaction gap are 30 mm long and thus the detector has ~50% detection efficiency for photons with average energy of 20 keV. The readout strips are connected to DMXG64 front-end chips that integrate charge from each bunch and store these data in an analogue memory. 100 cells Fig.5. Discharge of the front-end integrator through the feedback resistor. 64 Fig.2. Block-diagram of the DMXG64 ASIC. Fig.8. Schematic design of the DIMEX. Fig.6. Electronic calibration of the DMXG64 ASIC. Time structure of the signal measured with SR beam at the VEPP3 beam line 0 is shown in Fig. 7. In the figure the dependences of signal in one channel and two consecutive analogue memory cells is shown as a function of the time shift between the clock signal and bunch passing moment. The VEPP-3 operated in one bunch mode, i.e. the time between two consecutive bunches is 250 ns. The detector was working in two regimes: with 125 ns cycle and 250 ns cycle. The detector cycle consists of two phases: the exposure phase, when the integrator collects charge coming from a strip, at the end of this phase the integrator output is connected to an analogue memory cell and the signal is recorded; the reset phase, when the integrator feedback is shorted. Fig.9. Front-end board of the DIMEX with 8 DMXG64 ASICs mounted. References: V.M. Aulchenko, O.V. Evdokov, L.I. Shekhtman, et.al., J. of Instrum. 2008. V. 3. P05005. R. Horisberger and D. Pitzl, NIM A 326 (1993), p.92. Titov V. M.; Pruuel E. R.; Ten K. A.; et al., COMBUSTION EXPLOSION AND SHOCK WAVES V.47 (2011), 6, P.615-626 Fig.2. Layout of the DMXG64 ASIC.