Calibration Instructions for Quarknet Cosmic Ray Detector

Slides:



Advertisements
Similar presentations
QUARKNET 2011 SESSION 1 1. Abstract Week One Hardware Performance Plateauing Flux Shower Lifetime Purpose, Research Question, Hypothesis Experimental.
Advertisements

Copyright © 2005 Rockwell Automation, Inc. All rights reserved. 1 Micro Logix 1100 RSLogix 500 LAB#2 Timing, Counting & Comparing.
Measuring Cosmic Ray Flux with a trigger and CAMAC readout - Page 1 Connect the Fluke 415 HV supply output to the input of the voltage distribution box.
COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
Conducted by: Adrian Lorenzana David Harris Muon Speed/Lifetime Study.
1st of year Checkout 1.Powering up detector(s) 1 st in the DARK Ramping up voltages slowly in 50 v steps 2. Look for signals 3. Check rates 4. Light leak.
Experimental Procedures Arrival at Desktop BASE Check that computer and DAQcard are still running. Sign in and start logbook entry (date and time). Note.
Simulation of Created Design Documentation on the simulation process of a basic injector-separation channel model design.
Cosmic Ray Detection Experimental Report Alisa Bredensteiner Endeavour Institute Santa Cruz Institute of Particle Physics Quarknet August 2010.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
QuarkNet 2011 Mohamed Ali-Hussein Ayasha Jabber. Cosmic Rays Discovered by Victor Hess in 1912 High energy particles (atoms, protons, electrons) traveling.
Changing the iPhone 5 from 3G mode to LTE mode. *IMPORTANT BEFORE YOU START!* iPhone MUST be charged and you MUST have access to iTunes.
Bug Session Two. Session description In this session the use of algorithms is reinforced to help pupils plan out what they will need to program on their.
LSU 06/04/2007BASIC Stamp Editor1 The BASIC Stamp Editor Programming Unit, Lecture 3.
Jimmy McCarthy International Cosmic Ray Day 26 th September 2012 Detecting Cosmic Rays.
LAB 1 MATLAB, dSPACE and Simulink
1 S. E. Tzamarias Hellenic Open University N eutrino E xtended S ubmarine T elescope with O ceanographic R esearch Readout Electronics DAQ & Calibration.
QuarkNet Muon Data Analysis with Shower Array Studies J.L. FISCHER, A. CITATI, M. HOHLMANN Physics and Space Sciences Department, Florida Institute of.
Scintillators, DAQ boards, and PMTs Getting Familiarized With the Equipment By Melissa Sussmann and Alex Bonnifield.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
SRI & SMS Training Module. Downloading the SRI & SMS Training Module Using a Mac 1.Visit
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
Energy Distribution of Cosmic Ray Muons Paul Hinrichs With David Lee Advised by Phil Dudero.
Part 2A (Today’s Part) Press and hold the small red button to turn receiver on Once the receiver acquires its position, press the page button until the.
Experiment Design SCIPP Teacher Workshop Mary Jo Nordyke August 2010.
Muon Speed Analysis Clara Woods, Kyler Natividad, Julia Rathmann-Bloch #phobic_penguins.
How to Plateau Calibration of the QuarkNet Cosmic-Ray Detectors A Guide for Students and Teachers. Edited Summer 2008, instructions specific for 6000 series.
Cosmic Ray Workshop May 15, Cosmic Ray Detector Kit.
Chamber Monitor Panel Emiliano Furfaro 16 october 2012.
QuarkNet and Cosmic Ray Muon Flux Experiments Florida Academy of Sciences Spring Conference 2009 Alfred Menendez and Michael Abercrombie with Dr. Marcus.
Calibration instructions for Quarknet Cosmic-Ray Detector How to Plateau the Counters A friendly guide for students and teachers Edited by Jeremy Paschke,
A guide to file sharing on Windows XP Peer to Peer File Sharing.
Subtractive Manufacturing Exercise #1 Step #2 Key Fob Project Using Velocity CNC Software for the CNC Milling Machine Note: In order to use this set of.
1 Colorado Space Grant Consortium Gateway To Space ASEN / ASTR 2500 Class #13 Gateway To Space ASEN / ASTR 2500 Class #13.
Luminosity Monitor Design MICE Collaboration Meeting 31 May 2009 Paul Soler.
In the (rare) normal operation mode main actions for editing the settings of the muon system and for checking the configuration and the noise level of.
Geiger counter NTHU General Physics Laboratory
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
Tool Removed During Cycle Fault #2 Conditions for Setting Tool cocked prox switch goes open during cycle AND force on load cell drops below 5 lbs. Active.
SNG via Webinar. Where’s Webinar??  Double click Aflac 2000 folder  Highlight “SNGWebCommunicator”  Right Click and “Send To - Desktop”
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
1 4-Integrating Peripherals in Embedded Systems. 2 Introduction Single-purpose processors  Performs specific computation task  Custom single-purpose.
Steve Chao & Maha Hamid. Day 1 After reviewing the syllabus for the two weeks, we moved to laboratory to take apart and rebuild two cosmic ray detector.
Feb C.Smith UVA EC energy calibration – g13 pass0 For pass0 data were cooked with CALDB calibration constants reset to nominal 10 channels / MeV.
Excel Lesson 15 Working with Auditing and Analysis Tools
June 17, 2009 Office 2007 Tips & Tricks.
QuarkNet Student Investigations
N.Tarshish, S. McNamara, B. Goldblatt, P. Suganthan
Installing Analysis Tool Pak
Let’s count cosmic rays.
QuarkNet and Cosmic Ray Muon Flux Experiments
Shift instructions August 16, 2017 Antoni Aduszkiewicz
Introduction to Audio Recording
Bomgar Remote support software
Creating a Media Server with a Raspberry Pi
INTRODUCTION Spice Excel.
Hellenic Open University
MicroEconomix 1500 RSLogix 500 LAB#2
Number Systems and Binary Arithmetic
הודעות ריענון מהיר והרחבות כתיבה לקובץ Low-Level דגימת אות Low-Level
MicroEconomix 1500 RSLogix 500 LAB#1
Setup Guide - DeviceNet Communication AC1314 with RSNetworx
Installing Analysis Tool Pak
Digital Chart Recorder Operation
Climate Surveys.
MACROS MUST BE ENABLED FOR THIS FILE TO WORK
APAC eQuote
Microsoft Excel 2007 – Level 2
Muon Lifetime Alden Deran.
Presentation transcript:

Calibration Instructions for Quarknet Cosmic Ray Detector How to Plateau the Counters A friendly guide for students and teachers Edited by Jeremy Paschke, August 2009 Instructions specific for 6000 series

Expected Flux Rough estimates say that one or two muons pass through the area of your hand every second. As you do this calibration process with the Quarknet Cosmic Ray Muon Detector (CRMD), you should expect your counters to detect approximately 10 muons per second (between 500 and 1000 counts per minute).

Review on Voltages There are two voltages you can adjust: Photomultiplier Tube (The PMT is the voltage you will adjust in this calibration process.) The PMT voltage amplifies all signals from the tube. The PMT voltage is adjusted through the power distribution unit (PDU). Threshold Level The threshold voltage can be set at various levels to discriminate against pulses of lesser magnitude. The threshold level is adjusted by typing commands on the computer. We recommend setting the threshold level to a constant 300 mV, and not adjusting it afterwards.

Common Commands: CD - Counter Disable will stop the scrolling up of events. CE - Counter Enable resumes the scrolling up of events. TL 4 300 - Set Threshold Level of all four counters to 300 mV. WC 00 3F - Write Counters to read a two-fold coincidence with all four counters activated. V1, V2 - View settings. H1, H2 - Help with commands

A Note on Numbering These instructions refer to the counters and channels as 0, 1, 2, 3. All the hardware and terminal commands refer to channels 0-3. Only the e-Lab refers to channels 1-4.

Step A Set all voltages on the photomultiplier tubes (PMTs) to minimum (0.3 V) by turning potentiometers on the four-way power distribution unit (PDU) all the way counterclockwise.

Step B Place counter 0 and counter 1 together in a stacked configuration.

Set threshold voltage for all four counters to 300 mV. Step C Set threshold voltage for all four counters to 300 mV. In your terminal emulator (Hyperterm for PCs, ZTerm for Macs), type TL 4 300 (TL = Threshold level; 4 = all counters; 300 = mV). Type V1 to view the first panel of setting to verify your commands were followed. Voltage (V) -0.300 Time (ns) Threshold Value

Step D Increase the PMT voltage for counter 0 until it reads between 40 and 60 events per second. Type WC 00 01 to activate only channel 0 and read a one-fold coincidence. Use the digital counter to monitor counts per time until you reach desired range.

Step E Set the DAQ card to accept only channels 0 and 1 with two-fold coincidence. (Type V1 to check settings are correct.) There are two ways to accomplish this: Activate all four channels (counters) and unplug the two that are not being used. Type WC 00 1F Activate only the counters that are being used. Type WC 00 13 for channels 0 and 1. Type WC 00 15 for channels 0 and 2. Type WC 00 19 for channels 0 and 3. Type WC 00 16 for channels 1 and 2. Type WC 00 1A for channels 1 and 3. Type WC 00 1C for channels 2 and 3.

Step F Measure the counts on channels 0 and 1 for one minute at time over increasing PMT voltages. Type ST 3 1 to read out counts on each channel and the coincidence counts for each minute. (Mode 3 displays the scalar count from each channel and resets the counters after each display. The 1 stands for the time interval you choose in minutes.)

Step G Record data in a table. The registers in the ST command are in hexadecimal. Record the readings for your two scalars of interest and the scalar for coincidence in hex and then convert to decimal. Create a data table: Ask your mentor for a copy of the Excel file: Plateau_Template_2009.xls

Note: If you have never used the Note: If you have never used the HEX2DEC( ) command in Excel, you will get a “NAME##” error in some boxes. You need to activate the proper tools. Go to the Tools pull-down menu and select Add-Ins. Then check the two top boxes: Analysis ToolPak, and Analysis ToolPak – VBA. Click <OK> and the file should now convert hexidecimal to decimal properly.

Step H Look for where the coincidence counts level off, or “plateau.” You should set the PMT voltage near the start of this plateau.

Steps I, J, K Now you have found the optimal operating voltage for counter 1. Record this value in your logbook and on the Excel file you are using. Repeat the process to calibrate the other three counters. In at least one case you will need to use a new reference counter. Make sure to set the reference counter at a high voltage (about 40-60 events per second).

Step L Once the CRMD is plateaued, let it run for a couple hours and capture the file through Hyperterm or Zterm. Upload a file to the e-Lab and run a performance study on that data. Make minor adjustments to PMT voltages to bring all channels together. An ideal perfomance plot shown to the side

(Plateau) Instructions Be aware that the detector might drift over time. This plateau calibration process ought to be repeated at least once a year. It’s a good activity for each new group of students. THE END of Calibration (Plateau) Instructions