Biological Indicator Incubator

Slides:



Advertisements
Similar presentations
3D Micromanufacturing Lab. School of Mechatronics Gwangju Institute of Science and Technology 3D Micromanufacturing Lab. School of Mechatronics Gwangju.
Advertisements

(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
Operating Functions.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
inFire HTC speed Furnace Webinar
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Refrigerators.
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
Training for Radiation Pagers Training for Radiation Pagers Berkeley Nucleonics Corporation 2955 Kerner Blvd. San Rafael, CA
① The output signal of a room thermostat is ON or OFF according to changes of room temperature ② The power supply to a motorized valve is ON or OFF according.
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
In this presentation you will:
Abaxis Piccolo xpress The piccolo xpress™ chemistry system is compact and easy to transport. The system consists of a portable analyzer and single-use.
Syringe Pumps. Topics  Diagrams  Principles of Operation  Applications  Safety  Operation  Preventive Maintenance  Common Failure Modes  Troubleshooting.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Installation and Initial Start Up by Martin Noska, Service Engineer, Aftersales & Service.
Installation and Initial Start Up Worldwide Manufacturer of PSA Generators by Laco Remias, Service Engineer, Aftersales & Service.
1 Engine Protector Safe Rider Vehicle Technologies (Pty) Ltd PO Box 11376, Rynfield South Africa Tel./ fax Cell:
Calibration (Qualification) of Centrifuge
AccuMax Multi-Point Injection Mechanics
1. 2 LXU800 User’s Manual 1.Installation – Windows XP UI Features Introduction Data Connection & Disconnection.
Domina PLUS B WORKING DIAGRAMS TROUBLESHOOTING INTERNAL VIEWS WIRING DIAGRAMS INSTALLATION 03 PREVIOUS MODEL.
Settings & Adjustments. Settings & Adjustments.
Scope To develop a interactive electronics control system and fabrication support to design a next Constant Climate Chambers. Existing product with heater,
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
Scope To convert panel meter based BOD incubator to a dedicated and customized control unit with enhanced feature and automation. Existing product with.
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
UTH-300 INSTALLATION AND MANUAL. Method of Wiring Adhesion Construction and Wiring Method #1.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
CUE – Make Any Pump an E-Pump
Service Section Technical Training December 2005.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
FEATURES USER’S MANUAL COLOR BOX CAMERA SDB-BAW SDB-BAW/T 1/3 " SONY 960H Dual Scan CCD High Resolution of 800TV Lines Min. Illumination of Lux at.
NN-CS596S Steam Microwave Oven. NN-CS596S Oven Specification.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
Using a Digital Data Logger North Carolina Immunization Program (NCIP)
UTH-65A VER. CAUTIONS ! PLEASE USE THE OUTLET PREPARED BY A QUALIFIED SERVICEMAN AND MUST CONFIRM IT BEFORE APPLY[SING AN ELECTRIC CURRENT.
USER GUIDE TEMPERATURE CONTROLLER TR-2006 Hot runner temperature controller ShenZhen TanRex Electronic Co.ltd.
James McIntyre VRF Training Manager V5 Key Components.
Coffee Dispenser Set Up and Operation. Set up and Operation Start Up following installation Assuming all installation requirements have been met and the.
shift to the Test Mode (Forced Operation).
Freestyle Precision Pro
Quick Start Guide for Flex Flow Pump
CUT40P training manual March.2011.
CA05FS Owner’s Manual Fuel Cell Technology Breath Alcohol Tester.
LONER MOBILE.
MANUAL UTH VER.
How SCADA Systems Work?.
"This document can not be used without Samsung's authorization"
Steps to fix Windows 10 Flashing Screen Problem
fischertechnik® RoboPro Software for Gateway To Technology® RoboPro
Biological Indicator Incubator
G450 and G460 battery pack maintenance
LIFEPAK® 1000 Defibrillator Orientation Guide
Millennium touch screen Operated Profiler Series Roaster control
Commercial Stainless Steel Freezers
Cashew Dryer User Manual
Digital Chart Recorder Operation
How to set up the Flexmort CoverCool™
Safety Meeting Topics Standby Generator Safety
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRK Sales Training Program
724 Temperature Calibrator
NRL NRL - Welcome to the NRL Sales Training Program
Presentation transcript:

Biological Indicator Incubator Operations Manual Version 1.0

Annex 1 Wiring Diagram for Incubator Foreword Thank you for purchasing our products:Biological Indicator, This Manual for users contains function and operation of the Instrument. In order to use the instrument properly, please read this manual carefully before using the Instrument. Opening Check Please check the Instrument and Appendix with the packing list when you first open the instrument packing case. If you find there is something wrong with the Instrument and the Appendix, do contact the vendor or the producer. 100-240V~ Adapter 24V Mains switch Sensor Heater Display Main board J8 J10 J3 J4 J1 panel J2 12

5 Maintenance and cleaning Contents 1. Introduction…………………………………………............1 1.1 Instrument configuration…………………….……..……..1 1.2 Structure Description…………………………………......2 1.3 Installing the device………………………………….…....3 2. Technical data……………………………………………….4 3. Safety precautions……………..……………………….......5 4. Operation guide..…………………………………………….6 4.1 Create a new program …………………………………....6 4.2 Program NO. setting……... ..……………………………..6 4.3 Temperature setting….……..…………………..………....6 4.4 Time setting……………………………………………..….6 4.5 Unit of time setting……………………………………..….6 4.6 Operate and Stop……………………………………....…..7 4.7 Optional Configuration…………………………………..…8 4.8 Temperature Calibration………………………….…….….9 5.Maintenance and cleaning…………………………….……11 6. Troubleshooting…………………………….......................11 Annex 1 Wiring Diagram for Incubator …………..………..12 The well in the block should be cleaned by the cloth stained with alcohol to assure good heat translation between the block and the test tube and no pollution. If there are smutches on the Instrument, clean them with cloth. Power off when cleaning the Instrument. When cleaning the well, don’t drop the cleaning liquid in the well. Corrosive cleaning liquid is strongly prohibited. 6 Troubleshooting Error Cause Solution No display Not plug in Switch is bad The controller is damaged Check the power supply plug the power again transfer switch Contact with the supplier or manufacturer “PT error” in the display with alarm Temperature sensor is open circuit or open circuit Contact with the supplier or manufacturer No heating of the block Heater fault Press invalid Membrane switch damage 11

ADJ 38.5 WAIT ADJ 40.0 user ADJ 39.8 user ADJ 50.0 WAIT ADJ 60.0 WAIT 1 Introduction This biological indicator incubator is the special equipment for the biological indicator, small volume, in light weight, which is suitable for the pressure steam sterilizer biological indicator, ethylene oxide sterilization biological indicator and kinds of biological indicators to detect the sterilization effect. Before first use of this instrument, please read the manual carefully. 1.1 Delivery package Incubator 1set transparency cover 1pc Adapter 1pc Operations manual 1pc Certification 1pc 1 4.8.3 On the waiting interface, pressing “P” and “Temp” key simultaneously, temperature rises to 40℃. ADJ 38.5 WAIT 4.8.4 When temperature reaches to 40℃, decimal digit begins to flicker, waiting for the calibrated value of 40℃. \ | / / | \ ADJ 40.0 user \ | / / | \ ADJ 39.8 user 4.8.5 If the actual temperature readout is39.8℃, press and  key to amend the display value to 39.8℃, press START/STOP key to confirm. ADJ 50.0 WAIT 4.8.6 Then the system will be heated up to next temperature calibration point automatically, user needs to take the same steps to finish each calibration point’s data entry. ADJ 60.0 WAIT ADJ 70.0 WAIT 4.8.7 After adjusting four calibration points, press “START/STOP“ to confirm input value. Display shows ” ADJ FINISHED” the equipment can be used normally after restart. ADJ FINISHED Note! During Temperature calibrating, the system will quit the temperature calibration system if Long press “p” more than 2 seconds, the fixed temperature value is invalid! Strongly recommended proceeding constant temperature calibration under indoor environment, and avoid the influence by some external exhaust equipment or cooling equipment cause the instrument ambient temperature fluctuation, which affect the calibration results. 10

1.2 Structure Description 4.8 Temperature Calibration The temperature of the Instrument has been adjusted before it is sold out. But if there is deviation between the actual temperature and the displayed temperature due to some reasons, you can do as follows to correct the error. Notes: The Instrument uses multipoint temperatures adjustment to ensure its veracity. The temperature veracity will be within ±0.3℃ after the multipoint temperature adjustment. Ambient temperature must be below 35 ℃ when calibrate temperature. Strongly recommended proceeding constant temperature calibration under indoor environment, and avoid the influence by some external exhaust equipment or cooling equipment cause the instrument ambient temperature fluctuation, which affect the calibration results. Adjustment methods as follows: 4.8.1 After the startup of the Instrument, it enters waiting interface. Make sure the temperature in display is below 35℃. If the temperature is higher than 35℃, you should wait until the temperature is below 35℃. 4.8.2 Inject olefin oil into one of the cone-shaped wells, and then put a thermometer into this well (Make sure the precision of the thermometer should be within 0.1℃and the temperature ball should be absolutely immerged into the cone-shaped well). Heat insulation material is needed on the block to separate it from the circumstance. Seeing from Fig a. Block Displayer Keyboard Fig a Thermometer Mineral oil cone-shaped well Power Switch Power Connector Adiabatic Board 9 2

rtf ENABLE rtf DISABLE orf ENABLE orf DISABLE apf ENABLE apf DISABLE 1.3 Installing the device 1.3.1 Place the incubator onto a level, horizontal surface. 1.3.2 Insert the column connector of the adapter to power connector of the device ,and insert another connector of the adapter to mains power supply. Voltage requirements within100-240v.  4.7 Optional Configuration after startup, Immediately press P and Timer keys at the same time, the system into the configuration menu. 4.7.1. Retain Temp. Function(RTF): Enable RTF function,system will be recorded current temperature after finish operating. Disable RTF function, the temperature will be cooling after finish operating. rtf ENABLE rtf DISABLE 100-240V~ 4.7.2. Power Outage Repeat Function(ORF): Enable ORF function,if the electricity goes off, the system will be auto re-operate last program when power recover. Disable ORF function, the system will not be auto re-operate last program when power recover. orf ENABLE DC 24V orf DISABLE 1.3.3 Press the power switch at the back of the instrument, the instrument automatically heating up to the stated temperature, heating up generally takes around five minutes. 1.3.4 When the equipment arrived to the target temperature, then put the test tube into the constant temperature block with transparent insulation cover. 4.7.3.Auto Run When Power On Function(APF): Enable APF function, system will be auto re-operate last program when power on. Disable APF, user need to press “Start/Stop” key to choose operation program after power on. apf ENABLE apf DISABLE tube lid When the product leave factory, the APF system is open, ORF and RTF close, user can manually configure according to actual needs. Under the conditions of APF and ORF function at the same time open, ORF priority than APF function. Short press start/stop button, the program save the current configuration information, and exit the current mode. 3 8

P1 32.5 WAIT P1 56.0 060 M --Finished-50.5-- ----28.7---- 2 Technical data 4.6 Operate and Stop 4.6.1 With the sound of “DI...”, instrument displays current temperature, and heat up to 56℃. 4.6.2 "WAIT," shows system is heating up, please WAIT. Model B80 Power supply DC24V Power 40W Temperature range RT+5 ℃ ~ 100 ℃ Timing range 1sec~999sec 1min ~ 999min 1hour~999hour Accuracy of the temperature ≤± 0.3℃ Display accuracy 0.1℃ Heating time (from 20 ℃ to 56 ℃) ≤6min Ambient temperature 5℃ ~ 35℃ Dimensions(L×W×H) 145mm×113mm×110mm Weight 0.5 kg ----28.7---- P1 32.5 WAIT 4.6.3 When program reaches set temperature, the buzzer alarm “di”, then the system start to count down. P1 56.0 060 M 4.6.4 After the end of the countdown, the system run over, display "Finished", at the same time show the current block real-time temperature. Then short press any key, into the parameter configuration interface. If long press the start/stop button, the system will return to run programs in this section again. --Finished-50.5-- During running the process, long press the START/STOP button, system stops running direct into parameter configuration screen. 7 4

4. Operate guide 3 Safety precautions 4.1 Create a new program After startup, long press the Start/Stop button for more than 2 seconds into the programming interface. This instrument allows the user to custom 9 program, from P1 to P9. -----28.7----- This product is a normal and an indoor Instrument. Before operating this equipment please read this manual carefully, otherwise it may cause personal injury. Only in the aspect of how to use electrical equipment installation trained and qualified personnel to operate the equipment. 4.2 Program NO. setting: \ | / / | \ P2 55.5 095 M Press “P” key, then press ▲ or ▼ to choose ID or section NO. The operator should not open or repair the Instrument by himself, which will result in losing the qualification of repair guarantee or occur accident. If there is some wrong with the Instrument, the company will repair it. 4.3 Temperature setting: \ | / / | \ Press “Temp” “▲” or “▼”, the value of display windows for setting temperature will increase or reduce. P2 55.5 095 M The Instrument should be put in the place of low temperature, little dust, no water and no sun or strong lamp. What’s more, the place should be good aeration, no corrosively gas or strong disturbing magnetic field, far away from central heating, camp stove and other hot resource. Don't put the Instrument in wet and dusty place. 4.4 Time setting: \ | / / | \ Press “Timer” “▲” or “▼”, the value of display windows for setting time will increase or reduce. P2 75.5 032 M Mains switch is on the rear of the device, push “I” to power on the device, and push “O” to power off the device. Timer parameters value is equal to “000” press”▼” key, then display “KEEP” means the program has been running. Press”▼” key, display “OFF” means this section program is closed. P2 55.5 KEEP P2 75.5 OFF Power connector is on the rear of the device, DC24V input, inside is “+” , Outside is “-”. 4.5 Unit of time setting: \ | / / | \ P2 55.5 032 H Short press the Timer, when the time unit flicker, user can press ▲or▼ to adjust the time parameters among seconds, minutes and hours. \ | / / | \ Power off when you finish your work. Pull off the connector plug when there’s long time no use of the Instrument and cover it with a cloth or plastic paper to prevent from dust. P2 55.5 032 M \ | / / | \ P2 55.5 032 s 5 6