PLUMBING UP-DATE 2013 AMTS presented by: Bill Plewes

Slides:



Advertisements
Similar presentations
Plumbing.
Advertisements

Typical Plumbing System
Water Re-Use in Construction Today Newly Adopted Provisions of the VA Uniform Statewide Building Code(USBC) Presented by: Guy Tomberlin, CBO Code Specialist.
Plumbing 101 for Property Managers Presented by: [Put your name here] Welcome to... [Delete these logos and put your logos here]
Chapter 9 Water and Basic Design “The next great world crisis will be water supply.” 2 issues: keep water out since 19th century, distribute water Read.
2012 Plumbing Codes International Plumbing Code Uniform Plumbing Code David McCarthy, P.E. City of Phoenix.
Plumbing System Albert Einstein was named an honorary member of the Plumbers and Steamfitters Union after publicly stating that he would become a plumber.
Chapter 20 Plumbing Plans.
Understanding and Designing Plumbing Systems
September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E
Equipment and Facilities. 154 Plan Review The local health department must assess your facility and equipment before: –Beginning construction of a food.
B.ARCH. SEMESTER-II AR 126 BUILDING TECHNOLOGY – P/H UNIVERSITY INSTITUTE OF ARCHITECTURE Scheme of Teaching L T P Total Scheme of Examination.
The New Low Lead Regulations 2014 AWWA Meeting February 26, 2014 LAURA A. TAYLOR (334)
BS9990 : 2015 Updates and/or Changes
PLUMBING FIXTURES INTRODUCTION CLASSIFICATION WATER DEMAND TRAPS
Wastewater generation
Adoption and Enforcement of NSF 372 What Devices Need to Comply Presented by: Julius Ballanco, P.E.
Hydronic Mechanical Controls
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Warm-up 4/6/15 What type of water do you have at your house? Objective:
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
SEWER PIPING DESIGN Sewer piping differs from water piping, in that sewer pipes are not under pressure. The function that takes place inside sewer pipes.
Facilities Management and Design Chapter 5 Water and Wastewater systems.
Implementing Rain Water Harvesting into Building Construction in VA Presented by: Guy Tomberlin, CBO Code Specialist III Fairfax County DPWES, Land Development.
Materials And Construction Technology Materials And Construction Technology PALESTINE UNIVERSITY Chapter No.#8 Mechanical Works Dr. Ali Ibrahim Tayeh.
1 HVACR116 – Trade Skills Plumbing, HVAC, Electrical Overview.
© 2009 Michigan State University licensed under CC-BY-SA, original at Water Quality.
Chapter 18 Plumbing Plans.
Residential Construction Unit 5 Energy Efficiencies and Mechanicals Mr. Todzia.
BUILDING MATERIAL BUILDING MATERIAL PALESTINE UNIVERSITY chapter No.#7 Mechanical Works Dr. Ali Ibrahim Tayeh.
HVACR116 – Trade Skills Plumbing, HVAC, Electrical Overview.
Plumbing Unit.
Specification & Installation pitfalls “Getting it right to ensure safe drinking water”
Bellwork Fill out your KWL sheet about plumbing Fill out your KWL sheet about plumbing What do you K now about plumbing? What do you K now about plumbing?
CON 4003/CVE 4073/CVE 5073 Construction Estimating Prof R. V. Locurcio.
Smoke Testing Information
DOMESTIC DRAINAGE SYSTEM 2012BC25444
House Drainage System By- Prajyoti P. Upganlawar
Administration Code Changes to Incorporate Graywater Policy Principles Jayne Joy, P.E. Director, Environmental & Regulatory Compliance January 2016 EASTERN.
HOUSE DRAINAGE MEHTA ANJANI PRAFULBHAI =
Unit 209: Drainage systems
Unit 209: Drainage systems
GRAYWATER CURRICULUM. Class 2 Objectives Graywater Code Graywater History Water Quality Protection Graywater Systems and Terms Setback Requirements 2.
Coffee Dispenser Specifications and Installation Requirements.
Facilities Management and Design Chapter 5 Water and Wastewater systems.
CROSS CONNECTION CONTROL PROGRAM
Plumbing system fundamental and design course
Workshop developed by RCAP/AWWA and funded by the USEPA
Mahatma Gandhi Institute Of Technical Education & Research centre ,Navsari. A presentation on House Drainage Subject :- Environmental engineering.
Cross Connection Survey Training
Plumbing System Albert Einstein was named an honorary member of the Plumbers and Steamfitters Union after publicly stating that he would become a plumber.
Manitoba Building Officials Conference
Heating Ventilation and Air Conditioning
RESIDENTIAL PLUMBING SYSTEMS (WASTEWATER)
Zurn Industries, LLC.
Borbotech BV • Tel.: +31(0) • •
Unit 13 Plumbing Prints. Unit 13 Plumbing Prints.
What is an on-lot sewage system?
RESIDENTIAL PLUMBING SYSTEMS (WATER SUPPLY)
Plumbing.
Electrical Gas Plumbing Heating & Cooling
Heating Ventilation and Air Conditioning
Typical Plumbing System
ME444 ENGINEERING PIPING SYSTEM DESIGN
Plumbing System Albert Einstein was named an honorary member of the Plumbers and Steamfitters Union after publicly stating that he would become a plumber.
Module 4: Technical Requirements for Prefabricated Buildings – Alberta
2 Days National Workshop on “National Building Code of India 2016 ”
Heating Ventilation and Air Conditioning
Building standards Mr. Da Silva.
Plumbing System Albert Einstein was named an honorary member of the Plumbers and Steamfitters Union after publicly stating that he would become a plumber.
Full Service Plumbing Columbus, Ohio. plumbing The art and science of creating and maintaining sanitary conditions in a building used by humans. It is.
Presentation transcript:

PLUMBING UP-DATE 2013 AMTS presented by: Bill Plewes

2012 Building Code: Technical Changes Part 7 Plumbing

2012 Building Code Part 7- Plumbing There have been numerous changes to Part 7 Majority of changes are simple changes ie. renumbered, relocated, deleted, etc.

Consultations Two rounds of public consultations Fall of 2010 Spring 2011 Advisory technical committees met after each round

Process Committee weighs their decision on, Policy direction provide by MMAH Results from relevant consultations Must be technically viable and consistent with Code objectives The impact of the proposed change on the construction and operating costs of building Stakeholder impacts; and Enforceability Recommendations from technical committees are developed through a consensus process. MMAH will make the final decision based on the public response, policy impact, and technical committees recommendation when drafting the Building Code Changes.

Main Themes Supporting the economy by promoting innovation, reducing costs, increasing design flexibility and increasing harmonization with National Codes Enhancing energy and water conservation, reducing greenhouse gas emissions, adapting to climate change, protecting the environment; and Protecting public health and safety

Outline Definitions Materials Drainage Venting Water piping

Definitions Rainwater Storm drainage piping Sanitary sewage Sewer lateral extension

Rainwater NEW Rainwater means storm sewage runoff that is collected from a roof or the ground, but not from accessible patios and driveways.

Sanitary Sewage Sanitary sewage means, (a) liquid or water borne waste, (i) of industrial or commercial origin, or (ii) of domestic origin, including human body waste, toilet or other bathroom waste, and shower, tub, culinary, sink and laundry waste, or (b) liquid or water borne waste discharged from a public pool to a drain.

Sewer Lateral Extension NEW Sewer lateral extension means an extension of a public sewer that connects to a storm building sewer or sanitary building sewer 1.5 m beyond the property line and that serves not more than one property.

Storm Drainage Pipe Storm drainage pipe means all the connected piping that conveys storm sewage to a place of disposal and includes the storm building drain, storm building sewer, rain water leader, catch basin and area drain installed to collect water from the property and the piping that drains water from a swimming pool, other than a public pool, or from water cooled air-conditioning equipment, but does not include; (a) a subsoil drainage pipe, or (b) a private sewage treatment and disposal facility designed for the treatment or retention of storm sewage prior to discharge to the natural environment

Materials

Water Distribution Systems 7.1.5.3. (2)  Storm sewage or greywater that is free of solids and treated to conform to Article 7.7.4.1. is permitted to be used as a water supply for, (a) water closets, (b) urinals, (c) sub-surface irrigation, or (d) the priming of traps.

NEW 7.1.5.3 new sentence (3) (3)  Rainwater that is free of solids and treated to conform to Article 7.7.4.1. is permitted to be used as a water supply for, (a) clothes washers, (b) laundry trays, (c) mop sinks, (d) bedpan washers, (e) water closets, (f) urinals, (g) hose bibbs, (h) sub-surface irrigation, or (i) the priming of traps. (4)  Piping conveying the non-potable water described in Sentence (2) shall be installed in conformance with Section 7.7. Sentence (4) used to be (3) in previous code

Up-dated 7.1.5.5. (1) Private water supply pipes shall be designed and installed according to MOE PIBS 6881e, “Design Guidelines for Drinking-Water Systems”. (2) Private sewers shall be designed and installed according to MOE PIBS 6879, “Design Guidelines for Sewage Works”. Both are readily available on-line and it should be emphasized that these documents contain design guidelines. Legislation, including legislated standards and regulations, takes precedence over the Design Guidelines and must be followed.

Traps 7.2.3.1. (3) Except for a floor-mounted service sink, every trap that serves a lavatory, a sink or a laundry tray shall, (a) be provided with a cleanout plug of a minimum ¾ in. size located at the lowest point of the trap and of the same material as the trap, except that a cast iron trap shall be provided with a brass cleanout plug, (b) be designed so that the trap dip can be completely removed for cleaning purposes, or (c) be provided with a cleanout installed above the floor as close as practical downstream of the trap when the trap is, (i) installed below the floor, and (ii) not readily accessible for cleaning as required by Clause (a).

Trap installed below floor

Grease Interceptors Previously there were no standards 7.2.3.2. (3) Where a grease interceptor is required by Sentence 7.4.4.3.(1), the interceptor shall conform to, (a) CAN/CSA-B481.1, “Testing and Rating of Grease Interceptors Using Lard”, or (b) CAN/CSA-B481.2, “Testing and Rating of Grease Interceptors Using Oil”. Previously there were no standards

Polyethylene Water Pipe 7.2.5.5. (1) Polyethylene water pipe, tubing and fittings shall be certified to, and have a pressure rating meeting the requirements of, Series 160 or a higher series of CAN/CSA-B137.1, “Polyethylene (PE) Pipe, Tubing and Fittings for Cold Water Pressure Services Previously the code only stated Series 160

New Sentence 7.2.10.7.(1) Linings and coatings of domestic water tanks that come into contact with potable water shall be certified to NSF/ANSI 61, “Drinking Water System Components - Health Effects”. Concerns are related to leaching of chemicals in the storage tanks and therefore all linings and coatings of tanks must be certified.

7.2.10.14. Vent Pipe Flashing (1) Flashing fabricated on site for vent pipes shall be fabricated from, (a) copper sheet at least 0.33 mm thick, (b) aluminum sheet at least 0.48 mm thick, (was .61) (c) alloyed zinc sheet at least 0.35 mm thick, (d) lead sheet at least 1.73 mm thick, (was 2.16) (e) galvanized steel sheet at least 0.33 mm thick, or (was .41) (f) polychloroprene (neoprene) at least 2.89 mm thick.

New Article 7.2.10.17. Drinking Water Treatment Systems (1) A drinking water treatment system or device shall be certified to CAN/CSA-B483.1, “Drinking Water Treatment Systems”. Drinking water treatment systems covered by this Standard are intended to be used for the reduction or inactivation of harmful substances that can be present in drinking water Examples Reverse osmosis Ultra violet lights Water softeners' Etc .

New Article 7.3.3.12. Copper Joints Used Underground (1) Except as provided in Sentence (2), joints in copper tubes installed underground shall be, (a) made with either flared or compression fittings, or (b) brazed using a brazing alloy within the American Welding Society’s AWS-BCuP range. (2) Compression fittings shall not be used underground under a building.

New Sentence 7.3.6.1.(6) A sewer lateral extension need not be tested and inspected if the sewer lateral extension was constructed, tested and inspected at the time of the installation of the public sewer.

Suds Pressure Zone 7.4.2.1. (4) Where a change in direction of more than 45° occurs in a soil or waste pipe that serves more than one clothes washer, and in which pressure zones are created by detergent suds, no other soil or waste pipe shall be connected to it within a length less than, (a) 40 times the size of the soil or waste pipe or 2.44 m maximum vertical, whichever is less, before the change in direction, and (b) 10 times the size of the nominally horizontal soil or waste pipe after the change in direction.

(a) 40 times the size of the soil or waste pipe or 2 (a) 40 times the size of the soil or waste pipe or 2.44 m maximum vertical, whichever is less, before the change in direction, and (b) 10 times the size of the nominally horizontal soil or waste pipe after the change in direction.

New Sentence 5) Where a vent pipe is connected into a suds pressure zone referred to in Sentence (4), no other vent pipe shall be connected to that vent pipe within the height of the suds pressure zone. Suds may backup into other vents and prohibit the vents from working properly if tied into vents serving clothes washers

Rainwater Tanks 7.4.2.2. Connection of Overflows from Rainwater Tanks Previously; 7.4.2.2.(1) An overflow from a rainwater tank shall not be directly connected to a storm drainage system. 7.4.2.2. Connection of Overflows from Rainwater Tanks (1) Where an overflow from a rainwater tank is connected to a storm drainage system, it shall be connected by, (a) an air break, or (b) a backwater valve installed on the storm drainage pipe before the connection to the storm building drain. Sometimes indirect connection may not be possible, therefore, the proposed wordings will offer alternative means of direct connections with proper protection.

Backwater Valves 7.4.6.4. 3) Except as provided in Sentences (4) and (5), where a building drain or a branch may be subject to backflow, (a) a backwater valve shall be installed on every fixture drain connected to it when the fixture is located below the level of the adjoining street, or (b) a backwater valve shall be installed to protect fixtures which are below the upstream sanitary manhole cover when a residential building is served by a public sanitary sewer The current Code does not require a backwater valve to be installed on any fixture below the upstream sanitary manhole cover when a home is serviced by a public or private sanitary sewer system. The current proposal will minimize sewage backup.

Kitchen Sink Cleanout 7.4.7.1. revised (10) A cleanout shall be installed on a trap arm serving a kitchen sink as close as practical to the trap outlet and shall be readily accessible. Cleaning with the use of a trap dip may damage to the threads of a union trap and trap dip. To accommodate for cleaning purposes, a cleanout installed on the fixture drain serving a kitchen sink, as close as possible to the trap outlet prevents possible damage to the threads of a union trap and trap dip.

Water Closets New Sentence 7.4.9.2. (5)  No vertical leg of the drainage pipe from a water closet or other fixture that has an integral siphonic flushing action shall exceed 1 000 mm This was introduced to prevent siphonic action. (self siphonage)

Maximum vertical drop from water closet flange not to exceed 1000mm

Clothes washer Table 7.4.9.3. revised Clothes washer (a) domestic & (b) commercial 2 in. trap Due to changes in clothes washer designs and prevalence of front-loading machines with faster pump capacities new installations are overflowing and there is a need to upgrade the standpipe and trap dimensions. Table has been revised to indicate a 2-inch trap for both domestic and commercial clothes washers.

Wet Venting 7.5.2.1.(1) (g) the hydraulic load of separately vented fixtures that drain into the wet vent are not included when sizing the continuous vent that serves the wet vent,

Separately Vented

Wet Venting 7.5.2.1. (1) (i) where a wet vent extends through more than 1 storey, there is not more than one nominally horizontal offset in the wet vent, and, (i) the offset does not exceed 1 200 mm for pipes 2 in. or less in size, or (ii) the offset does not exceed 2 500 mm for pipes larger than 2 in. in size, Due to revisions to the 2006 venting requirements, a discrepancy had been introduced by this wording. The limit on nominally horizontal offset only applies to a wet vent which is extended through more than one storey. (k) the highest fixture is connected to a vertical portion of the wet vent, upstream of any other fixtures, in the form of a continuous vent, It also did not indicate the highest fixture must discharge into the wet vent that is connected into a continuous vent.

Vent Stacks 7.5.4.2. OLD (1)  Except as provided in Sentence (2), every soil or waste stack greater than 4 storeys in height shall have a vent stack. New (1)  Except as provided in Sentence (2), every soil or waste stack draining fixtures from more than 4 storeys shall have a vent stack. The requirement has been edited to clarify intent. The word greater has been replaced by draining fixtures from more and the words in height have been deleted. Without this clarification, a stack that physically passes through more than 4 storeys would require a vent stack even though it might only be serving the 5th storey.

If only the top three floors were discharging into the soil stack, then no vent stack would be required.

Length of Trap Arm T.7.5.6.3. Revise Table to harmonize with NPC. Size of trap served, in Maximum Trap Arm, m Minimum Slope 1 ¼ 1.5 1 in 50 1 1/2 1.8 was 1.5 2 2.4 was 1.5 3 3.6 was 1.8 4 4.9 was 3 9.8 new 1 in 100

Protection from Backflow No change here. Just relocated to Reserved article 7.6.2.3.   (1)  Except as provided in Sentence (3) and Articles 7.6.2.4. to 7.6.2.6., where a backflow preventer is required by this Subsection, the backflow preventer shall be selected, installed and tested in conformance with CSA B64.10, “Selection and Installation of Backflow Preventers”. (2)  Backflow preventers shall be provided in conformance with Sentence 7.2.10.10.(1). (3)  Tank type water closet valves shall be provided with a back - siphonage preventer in conformance with Sentence 7.2.10.10.(2). In the 2006 Code, these sentences were embodied in 7.6.2.4. Backflow from Fire Protection Systems.

Premise Isolation Relocated Exist. And modified to reserved 7.6.2.6.  Premise Isolation (1)  Buildings or facilities, where a moderate hazard or severe hazard may be caused by backflow, shall be provided with premise isolation of the potable water system by the installation of a backflow preventer selected in accordance with Clauses 5.3.4.2.(b) and (c) of CSA B64.10, “Selection and Installation of Backflow Preventers”. (2)  Buildings of residential occupancy within the scope of Part 9 are not required to be isolated unless they have access to an auxiliary water supply. (3)  Except as provided in Sentence (1), where no direct connection exists between the auxiliary water supply and the potable water system, premise isolation shall be provided by a dual check valve backflow preventer conforming to CAN/CSA-B64.6, “Dual Check Valve Backflow Preventers (DuC)”.

Potable Water 7.6.3.1.(2) relocated from 7.6.6.1.(1) (2)  A potable water system shall be designed, constructed and installed to conform to good engineering practice appropriate to the circumstances, such as that described in the ASHRAE Handbooks and ASPE Data Books.

Revise Existing Subsections Updated F.U. for water-conserving fixtures, appliances and devices in the referenced tables (next slides) Three options in Water pipe sizing method A. Detailed engineering analysis method B. Average pressure loss method C. Simplified method To fully understand how to size water piping correctly, you will need to take a course.

Table 7.6.3.2.A. Sizing of Water Distribution Systems(1)(2) Forming Part of Sentences 7.6.3.2.(1) to (3) and 7.6.3.4.(2), (3) and (5) EXAMPLE Fixture or Device Minimu m Size of Supply Pipe, in. Private Use Hydraulic Load, fixture units Public Use Hydraulic Load, fixture units Cold Hot Total 1. Bathroom group with 6 LPF flush tank(3) N/A 2.7 1.5 3.6 - 2. Bathroom group with greater than 6 LPF flush tank(3) 4 3 6 3. Bathroom group with more than 3 fixtures (4) 4. Bathtub with or without shower head 1/2 1 1.4 5. Bathtub with ¾ in. spout 3/4 7.5 10 6. Bedpan washer 7. Bidet 3/8 2 8. Clothes washer, 3.5 kg 2.25 9. Clothes washer, 6.8 kg

Direct Flush W/C and Urinals 7.6.3.2. (4)  The hydraulic load of urinals and water closets with direct flush valves shall be the number of fixture units listed in Tables 7.6.3.2.B. and 7.6.3.2.C.

Table 7.6.3.2. B

T.7.6.3.2.C

Hydraulic Loads of Fixtures not listed

Sizing of water system Table 7.6.3.4. Water Pipe Sizing for Buildings Containing One or Two Dwelling Units or Row Houses with Separate Water Service Pipes Forming Part of Sentence 7.6.3.4.(5) Item Column 1 Column 2 Column 3   Size of Water Pipe, in. Water Velocity m/s(1) 2.4 1.5 Hydraulic Load, fixture units 1. 1/2 7 4 2. 3/4 16 9 3. 1 31 18 4. 1-1/4 57 30

Table 7.6.4.1. Maximum Flow Rates for Water Supply Fittings Item Column 1 Column 2 Column 3 Fitting Max. Flow, L/min Test Pressure, kPa 1. Lavatory Faucet 8.35 413 2. Kitchen Faucet 3. Shower Heads in Residential Occupancy 9.5 7.6 550 4. Shower heads in other Occupancies 9.5 Shower heads were shown as one line in previous code. No distinction between residential and other occupancies

Table 7.6.4.2. Maximum Flush Cycles for Sanitary Fixtures Item Column 1 Column 2 1. Water Closet (Tank Type) 6 6.0 2. Water Closet (Direct Flush) 3. Urinal (Tank Type) 3.8 1.9 *(1) 4. Urinal (Direct Flush) *(1) Urinals equipped with automatic flushing devices shall be controlled to prevent unnecessary flush cycles during building down time

Table 7.6.4.2.B. Maximum Water Consumption per Flush Cycle for Sanitary Fixtures in a Group C Occupancy Item Column 1 Column 2 Fixture Maximum Water Consumption per Flush Cycle, LPF 1. Water Closet (Tank Type 4.8 *(1) 2. Water Closet (Direct Flush) 4.8 3. Urinal (Tank Type) 1.9 *(2) 4. Urinal (Direct Flush) 1.9 *(2) Water closets which provide a dual flush cycle option of both 4.1 LPF or less and 6.0 LPF are deemed to comply. Urinals equipped with automatic flushing devices shall be controlled to prevent unnecessary flush cycles during building down time.

Non-Potable Water Connections NEW 7.7.1.1.  Non-Potable Connection (1)  Except as permitted by Sentences (2) and (3), a non-potable water system shall not be connected to a potable water system. (2)  Make-up water may be supplied to the non-potable water system by, (a) a reduced pressure backflow preventer, or (b) an air gap. To protect the potable water source

Non-Potable Water Connections NEW (3)  Where a clothes washer is supplied by a rainwater system and a potable water system, the potable water system shall be protected by dual check valve backflow preventers conforming to CAN/CSA-B64.6, “Dual Check Valve Backflow Preventers (DuC)” for, (a) area isolation, and (b) premise isolation. To protect the potable water source

Identification 7.7.2.1.  Markings Required (1)  Non-potable water piping shall be identified by markings that are permanent, distinct and easily recognized. NEW (2)  Non-potable water system for re-use purposes shall be marked in accordance with Section 12 of CAN/CSA-B128.1, “Design and Installation of Non-Potable Water Systems”. NEW (3)  A sign containing the words Non-Potable Water, Do Not Drink shall be in letters at least 25 mm high with a 5 mm stroke and posted immediately above a fixture that is permitted to receive non-potable water.

7.7.3.2. Outlets (1) Except as permitted in Sentence 7.1.5.3.(3), an outlet from a non-potable water system shall not be located where it can discharge into, (a) a sink or lavatory, (b) a fixture into which an outlet from a potable water system is discharged, or (c) a fixture that is used for a purpose related to the preparation, handling or dispensing of food, drink or products that are intended for human consumption. 7.1.5.3.(3) speaks to “Rainwater that is permitted to be used as a water supply”

Non-Potable Water Standards 7.7.4.1. (1)  Non-potable water systems for re-use purposes shall be designed, constructed and installed to conform to good engineering practice appropriate to the circumstances such as described in, (a) the ASHRAE Handbooks, (b) ASPE Data Books, or (c) CAN/CSA-B128.1, “Design and Installation of Non-Potable Water Systems”.