Sub Station.

Slides:



Advertisements
Similar presentations
Introduction to Switchgear
Advertisements

During fault behavior of circuit breaker
ELECTRIC TRACTION SYSTEM
Prepared by Kazi Md. Shahiduzzaman Circuit Breker.
Chapter 2 ELECTRICAL POWER SUPPLY AND DISTRIBUTION IN BUILDINGS
SUBSTATION HIGH VOLTAGE COMPONENTS
How Electricity enters in our houses Electricity supplied to us at our home is 220 volt and A.C.. This main line power and the wires carrying it are called.
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Substations. Substations Chapter 4 Substations Major types of equipment found in most transmission and distribution substations with their purpose,
ABS Ennin, George Coleman, David Dadson & Anthony Ansah
Unit-3 SUBSTATIONS.
THE ELECTRIC SUB STATION
WHO WANTS TO BE A MILLIONAIRE?
Module 5, Unit A Vocabulary Review Game. 2 pt 3 pt 4 pt 5pt 1 pt 2 pt 3 pt 4 pt 5 pt 1 pt 2pt 3 pt 4pt 5 pt 1pt 2pt 3 pt 4 pt 5 pt 1 pt 2 pt 3 pt 4pt.
Power Factor Improvement Lecture 9. Normally, the power factor of the whole load on a large generating station is in the region of 0·8 to 0·9. However,
POWER HOUSE.
Submitted to: Submitted by:
Introduction to switchgears
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
A SUMMER TRANNING PRESENTATION ON 400 KV GRID SUB STATION BIKANER
A Presentation On 132 KV GSS BEHROR
Submitted to: Submitted by:
SEMINAR PRESENTATION ON 220 KV GSS UDAIPUR
Distribution Systems-General
SERVICE ENTRANCE EQUIPMENT
ON 400 KV GSS RAISER JAIPUR ROAD ,BIKANER
Department of Electrical Engineering
A Training Presentation On 220 KV GSS CHOMU,JAIPUR
A Training Presentation On 132 KV GSS JAIPUR Submitted in partial fulfillment For the award of the degree of BACHELOR OF TECHNOLOGY Submitted To:- Submitted.
132KV GSS PIPAR CITY JODHPUR
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Block Diagram of a Typical Electric Supply System
A PRESENTATION On 400KV GSS SURPURA JODHPUR
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
This project on Primary sub station of Visakhapatnam port trust at Visakhapatnam. It is 132kv/11kv substation with incoming feeder from APTransco and 11.
ELECTRICAL INSTRUMENTS ( service and utilization )
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Instrument Transformer Electrical Measuring Instruments & Instrumentation 3rd SEMESTER ELECTRICAL ENGG.
D.C. Machine & Transformer Topic: Instrument Transformer Electrical:-1 presented by: Jill Chauhan ( ) Chirag Agarawal ( )
1 :. Introduction These are special type of transformers used for the measurement of voltage, current, power and energy. As the name suggests, these transformers.
Equipment 1.Circuit Breaker. 3.Fuses. 4.Protecti- ve relay.2.Bus bar. TYPES OF SWITCH GEAR EQUIPMENT:-
6 Week industrial Training Presentation
SEMINAR PRESENTATIon ON C IRCUIT B REAKER DEPT. OF ELECTRICAL ENGG. JALPAIGURI GOVT. ENGG. COLLEGE PRESENTED BY Madhusudan Mahato Malay Ghosh.
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
HNC/D Engineering Science
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
POWER DISTRIBUTION & POWER LOSS REDUCTION METHODS
Introduction to Electric Power System and A. C. Supply
Balaji engineering college Special transformer
E4 HVACR Electrical Installation
SUB-STATIONS.
Chapter # 25 Sub-Stations risemark.pbworks.com.
Power Generation and Distribution
E4 HVACR Electrical Installation
ELECTRIC TRACTION SYSTEM
DISTRIBUTION
Basics of electrical engineering
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Design of Electric Power Systems and Utilities
Engineering Project Cable Management.
Components of Substation
ELECTRICAL POWER-II Electrical engineering sixth semester
DISTRIBUTION SYSTEMS (Theory) By M A R Uzair Assoc Prof EEE NSAKCET
Chapter 33 Transformer: Three Phase. Chapter 33 Transformer: Three Phase.
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
CHAPTER – 41 A.C. TRANSMISSION AND DISTRIBUTION
0 Air Blast Circuit Breaker under the guidance of:- Presented By:- Mr. B.R.Reddy Anuj Kumar Pandey EN-3 rd year Roll No Unrestricted.
Substation Equipment's
DIPLOMA In ELECTRICAL ENGINEERING DEPARTMENT OF ELECTRICAL ENGINEERING GOVERNMENT POLYTECHNIC COLLEGE, HANUMANGARH Sept A Training Presentation On.
Presentation transcript:

Sub Station

Introduction The electric power is produced at the power stations which are located at favorable places delivered to the consumers through a large network of transmission and distribution. it may be desirable and necessary to change some characteristic (e.g. voltage, a.c. to d.c., frequency, p.f. etc.) at many places in the line. This is accomplished by suitable apparatus called substation.

Sub-Station The assembly of apparatus used to change some characteristic (e.g. voltage, a.c. to d.c., frequency, p.f. etc.) of electric supply is called a sub-station. It should be located at a proper site. As far as possible, it should be located at the centre of gravity of load. It should provide safe and reliable arrangement, facilities for carrying out repairs and maintenance It should be easily operated and maintained It should involve minimum capital cost.

Classification of Sub-Stations According to service requirement to change voltage level or improve power factor or convert a.c. power into d.c. power etc (i) Transformer sub-stations. change the voltage level of electric supply Most of the sub-stations in the power system are of this type

(ii) Switching sub-stations do not change the voltage level i.e. incoming and outgoing lines have the same voltage. However, they simply perform the switching operations of power lines. (iii) Power factor correction sub-stations improve the power factor of the system generally located at the receiving end of transmission lines. generally use synchronous condensers as the power factor improvement equipment.

(iv) Frequency changer sub-stations change the supply frequency frequency change may be required for industrial utilization. (v) Converting sub-stations change a.c. power into d.c. power to supply for such purposes as traction, electroplating, electric welding etc. (vi) Industrial sub-stations supply power to individual industrial concerns

According to constructional features. (i) Indoor sub-stations. For voltages upto 11 kV, the equipment of the sub-station is installed indoor because of economic considerations. When the atmosphere is contaminated with impurities, these sub-stations can be erected for voltages upto 66 kV. (ii) Outdoor sub-stations For voltages beyond 66 kV, equipment is invariably installed outdoor. The clearances between conductors and the space required for switches, circuit breakers and other equipment becomes so great that it is not economical to install the equipment indoor.

(iii) Underground sub-stations When the space available for equipment and building is limited and the cost of land is high. Under such situations, the sub-station is created underground. (iv) Pole-mounted sub-stations This is an outdoor sub-station with equipment installed overhead on H-pole or 4-pole structure. It is the cheapest form of sub-station for voltages not exceeding 11kV (or 33 kV in some cases)

Comparison between Outdoor and Indoor Sub-Stations

Transformer Sub-Stations Transformer sub-stations may be classified into : (i) Step-up sub-station (ii) Primary grid sub-station (iii) Secondary sub-station (iv) Distribution sub-station

Pole mounted substation

Symbols for Equipment in Sub-Stations

Equipment in a Transformer Sub-Station 1. Bus-bars When a number of lines operating at the same voltage have to be directly connected electrically, bus-bars are used as the common electrical component. The incoming and outgoing lines in a sub-station are connected to the bus-bars. The most commonly used bus-bar arrangements in sub-stations are : (i) Single bus-bar arrangement (ii) Single bus-bar system with sectionalisation (iii) Double bus-bar arrangement

2. Insulators They support the conductors (or bus-bars) and confine the current to the conductors Material for the insulators is porcelain 3. Isolating switches It is often desired to disconnect a part of the system for general maintenance and repairs. This is accomplished by an isolating switch or isolator

4. Circuit breaker A circuit breaker is an equipment which can open or close a circuit under normal as well as fault conditions. It is so designed that it can be operated manually (or by remote control) under normal conditions and automatically under fault conditions. A relay circuit is used with a circuit breaker. Bulk oil circuit breakers are used for voltages upto 66kV while for high (>66 kV) voltages, low oil circuit breakers are used. Air-blast, Vacuum or SF6 circuit breakers are used for Higher Voltages

5. Power Transformers A power transformer is used in a sub-station to step-up or step-down the voltage. Either to use 3-phase transformers in sub-stations or 3 single phase bank of transformers can also be used Advantages of 3-phase transformer instead of 3 single phase bank of transformers only one 3-phase load-tap changing mechanism can be used. its installation is much simpler than the three single phase transformers.

6. Instrument transformers The function of these instrument transformers is to transfer voltages or currents in the power lines to values which are convenient for the operation of measuring instruments and relays. (i) Current transformer (C.T.). It is a step-up transformer which steps down the current to a known ratio. The primary of this transformer consists of one or more turns of thick wire connected in series with the line. The secondary consists of a large number of turns of fine wire and provides for the measuring instruments and relays a current which is a constant fraction of the current in the line.

(ii) Voltage transformer. It is essentially a step down transformer and steps down the voltage to a known ratio. The primary of this transformer consists of a large number of turns of fine wire connected across the line. The secondary winding consists of a few turns and provides for measuring instruments and relays a voltage which is a known fraction of the line voltage.

7. Metering and Indicating Instruments Ammeters, voltmeters, energy meters etc installed in a sub-station to maintain watch over the circuit quantities 8. Miscellaneous equipment (i) fuses (ii) carrier-current equipment (iii) sub-station auxiliary supplies

Bus-Bar Arrangements in Sub-Stations (i) Single bus-bar system it consists of a single bus-bar and all the incoming and outgoing lines are connected to it. Advantages- low initial cost, less maintenance and simple operation Disadvantage- If repair is to be done on the bus-bar or a fault occurs on the bus, there is a complete interruption of the supply

Single Bus Bar System

(ii) Single bus-bar system with sectionalisation The single bus-bar is divided into sections and load is equally distributed on all the sections. Any two sections of the busbar are connected by a circuit breaker and isolators. Advantages- if a fault occurs on any section of the bus, that section can be isolated without affecting the supply from other sections repairs and maintenance of any section of the busbar can be carried out by de-energising that section only, eliminating the possibility of complete shut down.

Sectionalize Bus bar

(iii) Duplicate bus-bar system consists of two bus-bars, a “main” bus-bar and a “spare” bus-bar Each bus-bar has the capacity to take up the entire sub-station load Ordinarily, the incoming and outgoing lines remain connected to the main bus-bar. However, in case of repair of main bus-bar or fault occuring on it, the continuity of supply to the circuit can be maintained by transferring it to the spare bus-bar.

Duplicate Bus Bar

Terminal and Through Sub-Stations Depending upon the manner of incoming lines, the sub-stations are classified as : (i) Terminal sub-station (ii) Through sub-station

(i) Terminal sub-station one in which the line supplying to the substation terminates or ends It may be located at the end of the main line or it may be situated at a point away from main line route.

(ii) Through sub-station one in which the incoming line passes ‘through’ at the same voltage

Key Diagram of 66/11 kV Sub-Station

Key Diagram of 11 kV/400 V Indoor Sub-Station

Thank You