Increase your efficiency with Schneider Electric MV DRIVE SYSTEMS Increase your efficiency with Schneider Electric Confidential Property of Schneider Electric
Altivar 1200 THE PRODUCT 2
Altivar 1200 Motor FRIENDLY and LOW Harmonic Technology Multi-level architecture Compact & environment friendly Innovative technology : Example of 6kV drive circuit 3
Altivar 1200 Multilevel architecture Output Voltage by Number of Cells 3,3kV 3 cells 4,16kV 4 cells 6,0kV 5 cells
Simple, Convenient, Reliable Altivar 1200 Simple, Convenient, Reliable Reliable Automatic Contactless Cell Bypass for a better reliability Convenient Easy Front access design for Control & Transformer maintenance Combined Control & Transformer cabinet Separated airflow cooling Modular inverter stage cubicle for fast maintenance Complete Well equipped as a standard : UPS, LS, lightening, Security screw, door locks… Control cabinet optimized for an Easy Customization 5
Altivar 1200 KEY FEATURES 6
Reduced Harmonic Technology Altivar1200 Key Features Reduced Harmonic Technology Input voltage (Green) and Current (Orange) Smooth to public grid 30 pulse THDi < 3% 36 pulse THDi < 2% 54 pulse THDi < 1% pF> 0.96 over the speed range Waveforms (line side) 7
Reduced Harmonic Technology Altivar 1200 Key Features Reduced Harmonic Technology LOW HARMONIC or negligible harmonics All standards like IEEE 519.1992 inherently fulfilled Save installation costs because no additional filters needed (CAPEX) Save costs of losses in your transformers and grid due to low harmonics (OPEX) 8
Motor FRIENDLY Great Waveform Altivar 1200 Key Features 9 JUST SHOW Voltage (Green) and Current (Orange) on motor side 9
Motor FRIENDLY ATV1200 Key Features No dU/dt peaks stressing motor insulation No output current harmonics are increasing rotor losses THDi < 2% 10
Motor FRIENDLY ATV1200 Key Features Long cable distances allowed Run EXISTING old motor Run all brands of motors Long cable distances allowed Up to 1000m and more Save money with energy saving projects at your old motor Save money with standard motor 11
Motor FRIENDLY Altivar 1200 Key Features Perfect waveform and input transformer avoids bearing currents Transformer and multilevel is the only architecture to cut common mode voltage effects 12
..at Pumps & Fans (ROI < 2 Years) Altivar 1200 PERFECT for OLD Motors ..at Pumps & Fans (ROI < 2 Years) 13
Premium & Standard No AUX. supply for fan needed !! …..saves CAPEX…. Altivar 1200 Premium & Standard Different Transformer Execution means: Providing cost effective execution with Standard Transformer selection No AUX. supply for fan needed !! …..saves CAPEX…. 14
Solid State Devices do work under all environmental conditions Altivar 1200 CONTACTLESS SYMETRICAL CELL BYPASS Solid State Devices do work under all environmental conditions E.g. a contact will not be reliable in a cement factory if 2 years not operating Keep operating with 75% of speed but with 100% current when using the Option Cell Bypass. We can offer 100% voltage with the Option N+1 power cells. 15
Altivar 1200 Easy to operate 16
KEY Features & Options Altivar 1200 All Field Busses to =SE= PLC No PC needed Key Interlock UPS inside as standard Internal Fan supply saves aux. supply (CAPEX) Synchronous Transfer 17
Altivar 1200 APPLICATIONS 18
10250 installed Units 12500 MW installed power MV Drive Offer Schneider Electric as Key Player 10250 installed Units Key segments : O&G, Mining, Power Gen. Metal, Water Installed based in more than 25 countries 12500 MW installed power Energy Managment expertise Karim to present Application Process knowledge
12050kW 11kV Gas Compressor Starters Place: Badra Oilfield, IRAQ Customer: M.A.N Turbo & Diesel Application: Centrifugal Compressor Customer requirement: Synchronous Transfer Multiple ETO requirements according O&G standards Product: ATV1200 A14900 1111 A4S Contact: Schneider Electric Germany Must be explained
1500kW 3300V District Heating Line Pumps Place: ROTERDAM Customer: AVR Application: Line Pumps Customer requirement: Reliability Product: ATV1200 A1830 3333 A4S Contact: Schneider Electric Netherlands Must be explained
1750kW, 780kW 6,6kV Loading Pumps Place: Pengerang, Malaysia Customer: VOPAK, Dialog, Petronas Application: Loading / Unloading Pumps Customer requirement: 6,6kV, low harmonic Product: ATV1200 A2020 6666 A3S Contact: Schneider Electric Kuala Lumpur Must be explained
Overland conveyor Place: Australia Customer: Rio Tinto Mesaa, WA Application: Conveyor twin drive Customer requirement: Multi drive with 1 x “synchronizer” Master and torque controlled slaves Product: 3,3kV - 2 x 800kW - 1 x 400kW Contact: Schneider Electric Beijing Must be explained