The “Monitor to measure the Integral TRAnsmittance” (MITRA)

Slides:



Advertisements
Similar presentations
Ground-based FTIR Update CAVIAR Meeting NPL, 29 th September 2010 Tom Gardiner, Marc Coleman.
Advertisements

Brown Bag Lunch Lecture ABI Calibration
An Assessment of the UV Broad Band Filter Radiometer Measurement Accuracy A. Los 1 and J. Gröbner 2 1)Kipp & Zonen, Delft (The Netherlands) 2)JRC, Ispra.
Microspectrophotometry Validation. Reasons for Changing Instruments Reduced reliability. Limited efficiency. Limited availability and cost of replacement.
Chapter 22 Heat Transfer.
Distance observations
Thermal Analysis of short bake out jacket version 1 12-Nov-2013.
Selection of measuring instruments
ASIC3 WorkshopLandsdowne, VA May 16-18, 2006 J. Harder Page 1 Calibration Status of the Solar Irradiance Monitor (SIM) : The Present and the Future Jerald.
E Usadi, NPL Low Temperature Blackbody for CAVIAR: Characterisation & Calibration Eric Usadi Thanks to Chris Price Theo Theocharous Title E Usadi 02Jun08.
Workshop TS May 2008 GENERAL CLIC ALIGNMENT Progresses and strategy. Hélène MAINAUD DURAND, TS/SU/MTI.
Chapter 16: Temperature and Heat. Heat Thermal energy that flows from something of high temp. to something of low temp. Warm  Cold Metric unit  Joules.
NOAA Research and Operations Marine Optical Buoy Design Review July 18-19, 2006 Plan for calibration and maintenance of AHAB Uncertainty Budget: Laboratory.
Improving Uncertainties of Non-Contact Thermometry Measurements Mark Finch Fluke Calibration.
Rachel Klima (on behalf of the MASCS team) JHU/APL MASCS/VIRS Data Users’ Workshop LPSC 2014, The Woodlands, TX March 17,2014 MASCS Instrument & VIRS Calibration.
Solar thermal energy Eng. Elamir Ahmed. Definition of solar thermal energy  Solar thermal energy is a renewable energy source.  Solar thermal uses technology.
Physikalisch-Meteorologisches Observatorium Davos, World Radiation Center (PMOD/WRC) And is signatory of the Mutual Recognition Arrangement by the Committee.
19 Nov 08,ILC08Cherrill Spencer Rotating Coil System Description 1 Short description of the SLAC rotating coil system used to measure the CIEMAT-made prototype.
Solar Radiation And it’s General Applications Nitin Jayswal.
Summary of thermal conduction gas tests for ANITA Goal: To measure the heat transport of different gases in a force-convection condition.
Sergey Mekhontsev National Institute of Standards and Technology Optical Technology Division, Gaithersburg, MD Infrared Spectral Radiance Scale.
October 29-30, 2001MEIDEX - Crew Tutorial - Calibration F - 1 MEIDEX – Crew Tutorial Calibration of IMC-201 Adam D. Devir, MEIDEX Payload Manager.
Chapter 10 Heat. Temperature, internal energy and thermal equilibrium Temperature is “a measure of the average kinetic energy of the particles in a substance.”
Thermal measurements in Glasgow Richard Bates, Isaac Bonad, Craig Buttar.
TECO2005WRC/PMOD Quality Management1 The World Radiometric Reference and its Quality System ISO/IEC Wolfgang Finsterle, Isabelle Rüedi, and Silvio.
NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable.
1 Reflected Solar Calibration Demonstration System - SOLARIS K. Thome, D. Jennings, B. McAndrew, J. McCorkel, P. Thompson NASA/GSFC.
Summary of thermal conduction gas tests for ANITA Goal: To measure the heat transport of different gases in a force-convection environment. John Clem,
Thoughts on the Design of a WVR for Alan Roy (MPIfR) the Twin Telescope at Wettzell.
Introduction to Thermal Physics
Dlab GmbH CH-8400 Winterthur Physikalisch-Meteorologisches Observatorium Davos DARA The new Three-Cavity Digitally- Controlled Radiometer for Space Application.
Title Light Detectors. Characteristics  Sensitivity  Accuracy  Spectral Relative Response(R( ))  Absolute Sensitivity(S( ))  Signal-to-noise ratio.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
Arctic Circle 2015, October 16-18, Reykjavík - Iceland MeteoMet Project: Metrology Activities in Ny-Ålesund (Svalbard) Chiara Musacchio Istituto Nazionale.
What is Heat?. Why did you put a jacket on this morning? What is cold? What is hot? Why are faucets labeled “H” and “C”? When you first turn on the “hot”
BELGISCH INSTITUUT VOOR RUIMTE-AERONOMIE INSTITUT D’AERONOMIE SPATIALE DE BELGIQUE BELGIAN INSTITUTE OF SPACE AERONOMY BELGISCH INSTITUUT VOOR RUIMTE-AERONOMIE.
MULTI-COMPONENT FUEL VAPORIZATION IN A SIMULATED AIRCRAFT FUEL TANK C. E. Polymeropoulos Department of Mechanical and Aerospace Engineering, Rutgers University.
1 Airborne Science Program EMASHSI Kick Off Meeting Interfaces NASA Ames Research Center University of California Santa Cruz Airborne Science & Technology.
Dr.Salwa Al Saleh What is Temperature? AVERAGE It is the measurement of the AVERAGE kinetic energy of the particles of matter.
How Convection Currents Affect Weather and Climate.
Hygrometry Part 2.
Damian Luna Yetziel Sandoval – Alberto Gonzales – 80546
Testing of Highly Accurate Blackbodies Harri Latvakoski Mike Watson Shane Topham Mike Wojcik SDL/
1 How Does Temperature Non-uniformity of an Annealing Furnace Affect SPRT Stability? Speaker: Mingjian Zhao Authors: Mingjian Zhao, Rose Heaton, Rong Ding,
1 CLARREO Advances in Reflected Solar Spectra Calibration Accuracy K. Thome 1, N. Fox 2, G. Kopp 3, J. McCorkel 1, P. Pilewskie 3 1 NASA/Goddard Space.
2015 GSICS Annual Meeting, Deli India March 16~20, 2015 Xiuqing Hu National Satellite Meteorological Center, CMA Yupeng Wang, Wei Fang Changchun Institute.
BELGISCH INSTITUUT VOOR RUIMTE-AERONOMIE INSTITUT D’AERONOMIE SPATIALE DE BELGIQUE BELGIAN INSTITUTE FOR SPACE AERONOMY BELGISCH INSTITUUT VOOR RUIMTE-AERONOMIE.
The “Monitor to measure the Integral TRAnsmittance” (MITRA)
Energy Transfer in the Atmosphere
Signal Transmission and Conversion, Test Review - Agenda
Miscellaneous Measurements
The Eppley Laboratory, Inc. 12 Sheffield Avenue, Newport, RI 02840
V2.0 minus V2.5 RSAS Tangent Height Difference Orbit 3761
Measurement Uncertainty and Traceability
What is Energy? Energy – the ability to do work
Results of Baltic Region Pyrheliometer Comparison, BRPC-2012
INVERSE BUILDING MODELING
An Overview of MODIS Reflective Solar Bands Calibration and Performance Jack Xiong NASA / GSFC GRWG Web Meeting on Reference Instruments and Their Traceability.
Characterization,calibration and traceability for lunar observation
GSICS/CEOS web meeting on Reference Solar Spectrum
Uncertainty (error) in praticals
Chapter 10 Heat.
Thermodynamics Kinetic-Molecular Theory of Heat-
L 18 Thermodynamics [3] Heat transfer Heat Capacity convection
Japan research of thermal propagation test
Shanghai Institute of Technical Physics , Chinese Academy of Science
Remote sensing in meteorology
15.3 energy in the atmosphere
Simplified Surface Temperature Modelling
Presentation transcript:

The “Monitor to measure the Integral TRAnsmittance” (MITRA) and the “Cryogenic Solar Absolute Radiometer” (CSAR) IPC-XII Seminar, Davos, 12 October 2015 Benjamin Walter, Wolfgang Finsterle, Andre Fehlmann, Rainer Winkler, Ricco Soder, Markus Suter, Werner Schmutz

WRR SI MOTIVATION Direct Solar Irradiance measurements [W m-2] traceable (Fehlmann et al. 2012) WRR internal stray light scale difference 0.34 % ± 0.09 % (k=1) Intercomparisons: SI

WRR SI MOTIVATION Direct Solar Irradiance measurements [W m-2] traceable WRR CSAR = LINK directly traceable SI Intercomparisons SI - cryogenic radiometers

The MITRA Instrument Transmittance depends on solar spectrum which changes with air mass and atmospheric conditions WSG World Standard Group CSAR = Cryogenic Solar Absolut Radiometer entrance window Monitoring of transmittance entrance window

Operation method & target uncertainty: window IPC-XI uncertainty ≈ 1 % Previous uncertainty > 1 % sensing Measuring temperature rise Δt at both cavities reference cavity Target uncertainty for the CSAR: 0.01% (= 100 ppm) spectrally integrated transmittance    MITRA requirement: uncertainty of tint < 100 ppm

Measurements in front of the sun WSG tracker  outdoor conditions HELIOSTAT  Laboratory conditions

Measurements in front of the sun Laboratory: - instrument stability = 150 ppm = 0.015% - heliostat windows: wavelength dependent reflectivity Outdoor: - instrument stability = 900 ppm ≈ 0.1% - Measurement influenced by: wind / temperature variations Two questions: 1. How accurate is the absolute value? 2. How to reduce wind and temperature variation problems in outdoor measurements?

How accurate is the absolute value?  Periodical recalibration ! Temperature differences must be very accurate:   no long term stability of parameters Δt measurement uncertainty < 0.1 mk no generally valid thermometer calibration possible  Periodical recalibration !

How accurate is the absolute value? Measured offset to validated simulations of Fehlmann: 1334 ± 300 ppm (k = 1) Calculated offset: 1290 ppm Good agreement between measured and calculated offset to simulations  Periodical recalibration ± 150 - 300 ppm (k = 1) depending on measurement conditions 2. wind and heat accumulation problem for outdoor measurements

WIND and HEAT ACCUMULATION: 10°C warmer relative to ambient air temperature

WIND and HEAT ACCUMULATION: Thermally-stable environment wind cannot enter the cavity covered by the window wind influences both cavities similarly Thermally-stable environment wind shelter

Thermally-stable environment No wind influences and Heat accumulation problems anymore electrical and thermal insulation Indirect cooling of MITRA - 6 Peltier elements - CPU fans - PID - controller Constant backplate temperature ≈ ± 0.1 K

Thermally-stable environment Measurement on the WSG sun tracking platform ≈ 0.6 K Calibration of thermometers < ± 1 mK

Thermally-stable environment Measurement on the WSG sun tracking platform ≈ 0.6 K ≈ ± 100 ppm

Thermally-stable environment Measurement on the WSG sun tracking platform ≈ 0.6 K ≈ ± 100 ppm uncertainty =115 ppm mean(tint) = 0.9269 ≈ ± 100 ppm

Thermally-stable environment Measurement on the WSG sun tracking platform ≈ ± 100 ppm uncertainty =165 ppm mean(tint) = 0.9269 ≈ ± 100 ppm

Summary MITRA improvements: ≈ ± 150 ppm Thermally-stable environment (Peltier cooling system)  Outdoor instrument stability ≈ 150 ppm (k = 1) Periodical recalibration of thermometers  Absolute value uncertainty about 150 - 300 ppm (k = 1) 3. Overall uncertainty: 250 - 350 ppm (k = 1)

Summary MITRA improvements: ≈ ± 150 ppm Promising results Future improvements to reach the 100 ppm goal: Three cavity design to monitor the temperature drift Liquid cooling of the instrument Larger heatsink to provide more stable conditions

Cryogenic Solar Absolute Radiometer (CSAR) Cryocooler (Helium) 20 K reference block quartz window 10 mm cavity View limiting aperture apertures

Cryogenic Solar Absolute Radiometer Measurement procedure: Cleaning the windows One day for cooling CSAR to 20K Cavity characterization Electrical measurements every 10-25 min Sampling rate = 3 s MITRA Helium pipes

Cryogenic Solar Absolute Radiometer IPC-XII DAY: 2015-09-30 CSAR measures about 0.2 - 0.3% lower than WRR

Cryogenic Solar Absolute Radiometer ( k = 2 ) IPC-XII Good agreement with previous findings of difference between the WRR and the SI scales. Detailed values and uncertainties will follow soon ...

Thank you for your attention! SUMMARY MITRA: Thermally-stable environment (Peltier system) a.) No wind influences / convection / heat accumulation b.) Strongly reduce temperature drift c.) Remaining drift can empirically be corrected for d.) Periodical recalibration of thermometers d.) MITRA uncertainty ≈ 250 - 350 ppm (k = 1) CSAR: a.) Overal stable performance b.) Preliminary results are in good agreement with previous findings that the SI scale is about 0.2% - 0.3% lower than WRR Thank you for your attention!

APPENDIX

Electrical separation First improvements: Technical improvements: Additional guiding rail Electrical separation of the motor

Accuracy improvements: First improvements: Accuracy improvements: Voltage reading: before and after electrically separating the motor before after

Accuracy improvements: First improvements: Accuracy improvements: Transmissivity (dark measurements): Uncertainty (1σ): Previously: 395 ppm 1 factor 10 improvement Now: 47 ppm

How accurate is the absolute value?   dark measurement: all 3 thermometers should measure the same temperature Δt measurement uncertainty < 1 mk   adjustment parameters

How accurate is the absolute value? Temperature conversion parameter adjustment: Experiments in vacuum tank and climate chamber:  all 3 thermometers should measure same temperature under thermal equilibrium for different temp ranges vacuum- chamber filled with nitrogen   parameter set

How accurate is the absolute value? Temperature conversion parameter adjustment: Experiments in vacuum tank and climate chamber:  all 3 thermometers should measure same temperature under thermal equilibrium for different temp ranges 17 parameter sets frequency spectrally integrated transmittance tint (mean of the day) mean: tint = 0.9257 ± 310 ppm ( k=1 standard uncertainty )