Building Automation System

Slides:



Advertisements
Similar presentations
Chapter 3. HVAC Delivery Systems
Advertisements

Chapter 12 HVAC Controls Pneumatic Control Systems • Air Compressor Stations • Transmitters and Controllers • Pneumatic Thermostats • Auxiliary Components.
HEALTHCARE BUILDING AUTOMATION
MCS LWC MAGNUM ORIGINAL CONCEPTS  Designed to Control Loop Systems  Build to be generic and handle many configurations of Loop Controllers  Type of.
HVAC CONTROLS (See section 18.9)
Objectives Control Terminology Types of controllers –Differences Controls in the real world –Problems –Response time vs. stability.
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
Commercial Mechanical Requirements
TYPES OF MECHANICAL SYSTEMS
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®
Foundations of Real Estate Management TM BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building.
The Role of Controls for Indoor Air Quality Kent W. Peterson, PE, Fellow ASHRAE P2S Engineering, Inc. Mid Columbia ASHRAE Chapter.
Components of HVAC System
Variable Frequency Drives VFD Basics
Engineer Presentation
Energy Management with the use of an Intelligent Building Management System.
Product Introduction.
AIR CONDITIONING SYSTEMS 1. All Air Systems An all-Air System is defined as a system providing complete sensible and latent cooling capacity in the cold.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
SCADA and Telemetry Presented By:.
An intelligent VAV zoning system
Static Pressure Control Loop The purpose of the static pressure control loop is to maintain an optimal static pressure in the ductwork. The control loop.
Intro Building automation describes the advanced functionality provided by the control system of a building. A building automation system (BAS) is an.
Air Side System Evaluation
BUILDING MANAGEMENT SYSTEM
Important variables Water: Air: Conversion:
Announcements Midterm Project Prepare groups of 3 to 4 students You can submit the list at the end of next class Midterm Exam 03/09/10 - In class Exam:
PROGRAMMABLE LOGIC CONTROLLER (PLC) AND AUTOMATION
1 Lamp operating factor Published lumen output is based on laboratory conditions Voltage  Rated at line voltage of 115V Standard reactor ballast  Electromagnetic.
Why Maintenance Tasks are Important Produced by Joe Marchese.
Lecture Objectives: Clarify issues related to eQUEST –for midterm project Learn more about various HVAC - economizer - heat recovery Discuss about the.
Embedded Design Using ARM For Strong Room Security System
Control Theory Control System Objectives  Establish a final condition  Provide safe operation  Eliminate the human element  Assure economical operation.
Roof Top Unit Overview (MAGNUM) Visit us at Revision- 12/17/2015.
Introduction to Energy Management. Week/Lesson 12 Advanced Technology for Effective Facility Control.
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Test and Balancing Functional Performance Test Presented by: John Shelander and Dan Acri.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
SCADA Supervisory Control And Data Acquisition Pantech Solutions Here is the key to learn more.
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
Lecture 10: Programmable Logic Controllers
Fan Coil Controller FC/S 1.1
Unit 13 Oil-Burning Equipment
Integrate Lighting, Daylighting and HVAC Control in the Laboratory Room Duane Ranski Siemens Industry Inc.
The Data Center Challenge
BUILDING HEATING AND COOLING
Story of No-Cost Energy Savings at Ohio Union
Heating, Ventilating, and Air Conditioning
How SCADA Systems Work?.
HVAC Basics Arkan Arzesh HVAC – Heating, Ventilation, Air-conditioning.
The Trend BMS An Introduction to BMS
Heating, Ventilating, and Air-Conditioning
Roof Top Unit Overview (MAGNUM)
HCB 3-Chap 19A: All-Air Systems_Single Zone
Chiller Plant Manager (CPM)
Sustainable Built Environment
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
Loop Water Controller Overview
Control System Instrumentation
The key to comfort and efficiency for heating and air-conditioning
The key to comfort and efficiency for heating and air-conditioning
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Objective Revie the Cooling Cycle Learn about air distribution systems
EUT 1040 Lecture 10: Programmable Logic Controllers Unrestricted.
‘‘ BUILDING AUTOMATION’’
Presentation transcript:

Building Automation System Andyka Irnanto

What is BAS Building Automation System a high technology system installed on buildings that controls and monitors the building’s mechanical and electrical equipment such us air handling and cooling plant systems, lighting, power systems, fire systems, and security systems.

What is BAS Building automation is a programmed, computerized, intelligent network of electronic devices that monitor and control the mechanical and lighting systems in a building. The intent is to create an intelligent building and reduce energy and maintenance costs.

Elements of a BAS Elements of a BAS installation: Controllers Sensors Cabling Software PC Workstations

Controllers Central controllers and most terminal unit controllers are programmable, meaning the direct digital control program code may be customized for the intended use. The program features include time schedules, setpoints, controllers, logic, timers, trend logs, and alarms. The unit controllers typically have analog and digital inputs that allow measurement of the variable (temperature, humidity, or pressure) and analog and digital outputs for control of the transport medium (hot/cold water and/or steam). Digital inputs are typically (dry) contacts from a control device, and analog inputs are typically a voltage or current measurement from a variable (temperature, humidity, velocity, or pressure) sensing device. Digital outputs are typically relay contacts used to start and stop equipment, and analog outputs are typically voltage or current signals to control the movement of the medium (air/water/steam) control devices.(Valves/dampers/motor speed)

Controllers Controller The controller is normally one or more , often with less complex programming. These controllers come in a wide range of sizes and capabilities to control devices that are common in buildings. Usually the primary and secondary buses are chosen based on what the controllers provide.

Sensors Types of Sensors: Movement Sensors Temperature Sensors Flow sensors Pressure sensors Humidity sensors

Applications of BAS: Lighting Control Lighting can be turned on and off with a building automation system based on time of day, or the occupancy sensors and timers. One typical example is to turn the lights in a space on for a half hour since the last motion was sensed. A photocell placed outside a building can sense darkness, and the time of day, and modulate lights in outer offices and the parking lot. This results in energy savings and reducing cost to the owner. .

Applications of BAS: Air HANDLING UNITS Air handlers mix return and outside air so less temperature change is needed. This can save money by using less chilled or heated water (not all AHUs use chilled/hot water circuits). Some external air is needed to keep the building's air healthy. Analog or digital temperature sensors may be placed in the space or room, the return and supply , and sometimes the external air. Actuators are placed on the hot and chilled water valves, the outside air and return air dampers. The supply fan (and return if applicable) is started and stopped based on either time of day, temperatures, building pressures or a combination..

Applications of BAS:Vav System Variable Volume Air-Handling Units A more efficient unit is a "Variable air volume(VAV) Air-Handling Unit," or VAV. VAVs supply pressurized air to VAV boxes, usually one box per room or area. A VAV air handler can change the pressure to the VAV boxes by changing the speed of a fan or blower with a variable frequency drive or (less efficiently) by moving inlet guide vanes to a fixed-speed fan. The amount of air is determined by the needs of the spaces served by the VAV boxes. Each VAV box supply air to a small space, like an office. Each box has a damper that is opened or closed based on how much heating or cooling is required in its space. The more boxes are open, the more air is required, and a greater amount of air is supplied by the VAV air-handling unit. Some VAV boxes also have hot water valves and an internal heat exchanger. The valves for hot and cold water are opened or closed based on the heat demand for the spaces it is supplying. These heated VAV boxes are sometimes used on the perimeter only and the interior zones are cooling only. A minimum and maximum CFM must be set on VAV boxes to assure adaquate ventilation and proper air balance.

HYBRID Systems VAV Hybrid Systems Another variation is a hybrid between VAV and CAV systems. In this system, the interior zones operate as in a VAV system. The outer zones differ in that the heating is supplied by a heating fan in a central location usually with a heating coil fed by the building boiler. The heated air is ducted to the exterior dual duct mixing boxes and dampers controlled by the zone thermostat calling for either cooled or heated air as needed

Security System CCTV System Closed Circuit Cameras Video Recording Access System

Alarms Many building automation systems have alarm capabilities. . Common temperature alarms are Space, Supply Air, Chilled Water Supply and Hot Water Supply. Differential pressure switches can be placed on the filter to determine if it is dirty. Status alarms are common. If a mechanical device like a pump is requested to start, and the status input indicates it is off. This can indicate a mechanical failure. Some valve actuators have end switches to indicate if the valve has opened or not. Carbon monoxide and carbon dioxide sensors can be used to alarm if levels are too high. Refrigerant sensors can be used to indicate a possible refrigerant leak. Amperage sensors can be used to detect low amperage conditions caused by slipping fan belts, or clogging strainers at pumps. At sites with several buildings, momentary power failures can cause hundreds or thousands of alarms from equipment that has shut down. Some sites are programmed so that critical alarms are automatically re-sent at varying intervals. For example, a repeating critical alarm (of a uninterruptible power supply in 'by pass') might resound at 10 minutes, 30 minutes, and every 2 to 4 hours there after until the alarms are resolved. Security systems can be interlocked to a building automation system. If occupancy sensors are present, they can also be used as burglar alarms. Fire and smoke alarm systems can be hard-wired to override building automation. For example: if the smoke alarm is activated, all the outside air dampers close to prevent air coming into the building, and an exhaust system can isolate the alarmed area and activate an exhaust fan to move smoke out of the area. Life safety applications are normally hard-wired to a mechanical device to override building automation control

Scheduling Applications Equipment scheduling (turning equipment off and on as required. . Optimum start/stop (turning heating and cooling equipment on in advance to ensure the building is at the required temperature during occupancy) Operator adjustment (accessing operator set-points that tune system to changing conditions) . Monitoring (logging of temperature, energy use, equipment start times, operator logon, etc) Alarm reporting (notifying the operator of failed equipment, out of limit temperature/pressure conditions or need for maintenance)

Internal systems Most building automation networks consist of a primary and secondary bus which connect high-level controllers (generally specialized for building automation, but may be generic programmable logic controllers) with lower-level controllers, input/output devices and a user interface (also known as a human interface device). The primary and secondary bus can be BACnet, optical fiber, ethernet, ARCNET, RS-232, RS-485 or a wireless network. Most controllers are proprietary. Each company has its own controllers for specific applications. Some are designed with limited controls: for example, a simple Packaged Roof Top Unit. Others are designed to be flexible. Most have proprietary software that will work with ASHRAE's BACnet or the proprietary LonTalk.

Internal system Inputs and outputs are either analog or digital (some companies say binary. Analog inputs are used to read a variable measurement. Examples are temperature, humidity and pressure sensor which could be thermistor, 4-20 mA, 0-10 Volt or Platinum RTD (resistance temperature detector). A digital input indicates if a device is turned on or not. Some examples of a digital input would be a 24VDC relay or air flow switch. Analog outputs control the speed or position of a device, such as a variable frequency drive or an actuator. An example is a hot water valve opening up 25% to maintain a setpoint. Digital outputs are used to open and close relays and switches. An example would be to turn on the parking lot lights when a photocell indicates it is dark outside.