V.I. Tretyak Institute for Nuclear Research, MSP Kyiv, Ukraine

Slides:



Advertisements
Similar presentations
Combined evaluation of PFNS for 235 U(n th,f), 239 Pu(n th,f), 233 U(n th,f) and 252 Cf(sf) (in progress) V.G. Pronyaev Institute of Physics.
Advertisements

NEST: Noble Element Simulation Technique Modeling the Underlying Physics of Noble Liquids, Gases Matthew Szydagis, UC Davis UCLA DM 02/28/14 1
Study of plastic scintillators for fast neutron measurements
Abstract Dark matter is a generic term for an exotic class of particles that might provide sufficient gravity to explain the observed movements of stars.
Solotvina Underground Laboratory
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
Electron-impact inner shell ionization cross section measurements for heavy element impurities in fusion reactors Jingjun Zhu Institute of Nuclear Science.
Data processing in the Activation technique experiment. Making stacked or sandwiched in the repeated order of Al-Cu-Mo. Irradiation of the samples Using.
Study of plastic scintillator quenching factors Lea Reichhart, IOP Glasgow, April /17.
Dark Matter Search with Direction sensitive Scintillator Ⅱ Department of Physics, School of Science The University of Tokyo Y. Shimizu, M. Minowa, Y. Inoue.
Elektro 041 Analysis of Acoustic Spectra Reflecting Ion Transport Processes in Glassy Electrolytes P. Hockicko a), P. Bury a), S. Jurečka b), M. Jamnický.
Neutron scattering systems for calibration of dark matter search and low-energy neutrino detectors A.Bondar, A.Buzulutskov, A.Burdakov, E.Grishnjaev, A.Dolgov,
1 The results of the study of dp-elastic scattering at the energies from 500 to 1000 MeV/nucleon A.A Terekhin et al. Joint Institute for Nuclear Research,
The Simulation of the quenching factor and the channeling effect for the CsI(Tl) and NaI(Tl) crystals Juhee Lee and Sunkee Kim Seoul National University.
Cross-sections of Neutron Threshold Reactions Studied by Activation Method Nuclear Physics Institute, Academy of Sciences of Czech Republic Department.
Some aspects of reaction mechanism study in collisions induced by Radioactive Beams Alessia Di Pietro.
Radiochemistry Dr Nick Evans
KPS Chonbuk University 2005/10/22 HYUNSU LEE Status of the KIMS dark matter search experiment with CsI(Tl) crystals Hyun Su Lee Seoul National.
Stefano Pirro – NuMass 2010 Stefano Pirro Double beta decay searches with enriched and scintillating bolometers - Milano - Bicocca The Future of Neutrino.
Daily Modulation of the Dark Matter Signal in Crystalline Detectors Nassim Bozorgnia UCLA TexPoint fonts used in EMF. Read the TexPoint manual before you.
Reaction studies with low-energy weakly-bound beams Alessia Di Pietro INFN-Laboratori Nazionali del Sud NN 2015Alessia Di Pietro,INFN-LNS.
WIMP search Result from KIMS experiments Kim Seung Cheon (DMRC,SNU)
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Activities on double beta decay search experiments in Korea 1.Yangyang Underground laboratory 2.Double beta decay search with HPGe & CsI(Tl) 3.Metal Loaded.
KIMS Seoul National University Juhee Lee 1 KPS in Changwon.
Pion-Induced Fission- A Review Zafar Yasin Pakistan Institute of Engineering and Applied Sciences (PIEAS) Islamabad, Pakistan.
Systematical Analysis of Fast Neutron Induced Alpha Particle Emission Reaction Cross Sections Jigmeddorj Badamsambuu, Nuclear Research Center, National.
PyungChang 2006/02/06 HYUNSU LEE CsI(Tl) crystals for WIMP search Hyun Su Lee Seoul National University (For The KIMS Collaboration)
1 CRESST Cryogenic Rare Event Search with Superconducting Thermometers Jens Schmaler for the CRESST group at MPI MPI Project Review December 14, 2009.
Scintillating Bolometers – Rejection of background due to standard two-neutrino double beta decay D.M. Chernyak 1,2, F.A. Danevich 2, A. Giuliani 1, M.
1 Semiempirical calculation of quenching factors for ions in scintillators V.I. Tretyak Institute for Nuclear Research, MSP Kyiv, Ukraine AMORE Collaboration.
Three years of cross-section measurements of (n,xn) threshold reactions at TSL Uppsala and NPI Řež O. Svoboda, A. Krása, A. Kugler, M. Majerle, J. Vrzalová,
1 st : Mass Spectrometry on Heavy Molecules with Cryogenic Detectors - status Project Review 2004 PROTEOM 2 nd : Measurement of the Quenching Factors in.
WIMPs Direct Search with Dual Light-emitting Crystals Xilei Sun IHEP International Symposium on Neutrino Physics and Beyond
Exploring the alpha cluster structure of nuclei using the thick target inverse kinematics technique for multiple alpha decays. The 24 Mg case Marina Barbui.
1 Recent results of the Kyiv group in 2  decay researches V.I. Tretyak Institute for Nuclear Research, MSP Kyiv, Ukraine AMORE Collaboration Workshop,
Investigation of the proton-induced reactions on natural molybdenum.
Status of ULE-HPGe Experiment for WIMP Search in YangYang
Determining Reduced Transition Probabilities for 152 ≤ A ≤ 248 Nuclei using Interacting Boson Approximation (IBA-1) Model By Dr. Sardool Singh Ghumman.
(on behalf of SIDDHARTA-2 collaboration)
The CRESST Dark Matter Search Status Report
Solar gamma-ray and neutron registration capabilities of the GRIS instrument onboard the International Space Station Yu. A. Trofimov, Yu. D. Kotov, V.
12th Geant4 Space Users Workshop
Secondary avalanches in gas mixtures
Institute for Scintillation Materials
Alain CARAPELLE et al., Centre Spatial de Liège - Université de Liège
UK Dark Matter Collaboration
at TSL high energy neutron facility
Cross-section Measurements of (n,xn) Threshold Reactions
DAMA: an observatory for rare
Giant Monopole Resonance
University of South Dakota
Emmanuel Clément IN2P3/GANIL – Caen France
CRESST Cryogenic Rare Event Search with Superconducting Thermometers
Irina Bavykina, MPI f. Physik
Sr-84 0n EC/b+ decay search with SrCl2 crystal
Direct Detection of Dark Matter
How precisely do we know the antineutrino source spectrum from a nuclear reactor? Klaus Schreckenbach (TU München) Klaus Schreckenbach.
Cyclotron Institute, Texas A&M University
(on behalf of the RENO collaboration)
Neutron Detection with MoNA LISA
Searching for states analogous to the 12C Hoyle state in heavier nuclei using the thick target inverse kinematics technique. Marina Barbui 5/17/2018, Galveston,
Modification of Fragmentation Function in Strong Interacting Medium
Chapter 4 Mechanisms and Models of Nuclear Reactions
Design of A New Wide-dynamic-range Neutron Spectrometer for BNCT with Liquid Moderator and Absorber S. Tamaki1, I. Murata1 1. Division of Electrical,
Elastic alpha scattering experiments
O. Svoboda, A. Krása, A. Kugler, M. Majerle, J. Vrzalová, V. Wagner
PHYS 3446, Spring 2012 Andrew Brandt
Change of 7Be decay rate under compression
Presentation transcript:

V.I. Tretyak Institute for Nuclear Research, MSP 03680 Kyiv, Ukraine Semiempirical calculation of quenching factors for ions in scintillators V.I. Tretyak Institute for Nuclear Research, MSP 03680 Kyiv, Ukraine RPScint’2009, 22-23.09.2009, Kyiv, Ukraine

Content: Introduction Outlines of the method Calculation of quenching factors: organic scintillators solid C8H8 liquid C16H18, C9H12 crystal scintillators pure CdWO4, PbWO4, ZnWO4, CaWO4, CeF3 doped CaF2(Eu), CsI(Tl), CsI(Na), NaI(Tl) liquid noble gases prediction of quenching factors for ions for some scintillators Conclusions

1. Introduction Motivations: Searches for dark matter: Universe – usual matter ~4%, dark matter ~23%, dark energy ~73%; WIMPs scatter on nuclei which constitutes detectors creating recoil ions; Amount of light produced in scintillator by ions is lower than that produced by electrons of the same energy (experimental fact); Thus, in scintillators calibrated with electrons or  quanta, signals from ions will be seen at lower energies than their real values (up to ~40 times); Evidently, knowledge of these transformation coefficients – quenching factors (QF) – is extremely important in searches for WIMPs, predicting where the signal should be seen; Many experimental efforts (sometimes very sophisticated) to measure QFs; It would be very nice if one would be able to calculate QFs. Investigation of rare alpha decays with scintillators (T1/2=1018-1019 yr): 180W in CdWO4 [F.A. Danevich et al., PRC 67 (2003) 014310] ; 180W in CaWO4 [Yu.G. Zdesenko et al., NIMA 538 (2005) 657]; 151Eu in CaF2(Eu) [P. Belli et al., NPA 789 (2007) 15].

2. Outlines of the method In calculation of QFs, we follow Birks approach in description of quenching of the light yield for highly ionizing particles [J.B. Birks, Proc. Phys. Soc. A 64 (1951) 874; The Theory and Practice of Scintillation Counting, Pergamon Press, Oxford, 1964] Light yield (LY) of highly ionizing particles in scintillating material depends not only on its energy E but also on its stopping power dE/dr Examples of stopping powers (SP) for electrons in CaWO4 calculated with the ESTAR code [M.J. Berger et al., Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions] and for different ions calculated with the SRIM code [J.F. Ziegler et al., SRIM. The Stopping and Range of Ions in Matter, SRIM Co., 2008]: Fig. 1b: Nuclear and electronic parts of SP Fig. 1a: Total SP

For particles with low SP (e at E>~100 keV): or (S is absolute scintillation factor) To account for suppression of LY for highly ionizing particles (ions) Birks proposed: (kB – Birks factor) Approximations of light yield for electrons and ions: but in general: Quenching factor (often for  particles: “/ ratio”) is ratio of LY of ions to LY of electrons: (1) S disappeared, and we have only 1 parameter: kB

Sometimes instead of QF, a relative LY is used as: (2) (ratio of ion’s LY to energy, normalized to that of electron) Relation between Q and R: (R is practically equal to Q if electron energies E and E0 are in energy range where L ~ E) Taking into account approximations: and we obtain the following approximation for QF: It gives the following important features of QF: QF depends on energy (not so trivial – in many papers constant QF was supposed); QF is minimal when dE/dr is maximal; QF increases at low energies (consequence of decrease of dE/dr, see Fig. 1).

In the following calculations: 1. all results are obtained with Eq In the following calculations: 1. all results are obtained with Eq. (1) or Eq. (2): 2. dE/dr are calculated with the ESTAR code for electrons and the SRIM code for ions (sometimes with the ASTAR code for  particles). 3. Total dE/dr is used. Some precautions when comparing experimental and calculated QF values: 1. QF depends on kind and amount of dopant in doped scintillators (like NaI(Tl)) but also could depend on impurities and defects in “pure” scintillators; 2. QF depends on temperature; 3. QF depends on such a technical parameter as time t during which scintillation signal is collected (see Fig. 2); if signals are not collected during proper time, it is possible to obtain wrong conclusions on QF values (enhancement instead of quenching); 4. It is better to use measurements of QFs when ions’ energies are exactly known (f.e. not with non-monoenergetic neutron sources like Am-Be – they give mixture of QFs for different E and different ions constituting scintillator).

[27] R. Gwin, R.B. Murray, Phys. Rev. 131 (1963) 501 Fig. 2: change of t from 1 s to 7 s resulted in change of QF (~30%) and in change of kB from 1.1e-3 to 2.3e-3 [kB everywhere is in g/(MeV cm2)] In the following, we will not expect that kB is some fundamental constant of scintillating material; its value could be different in different experimental conditions. However, we will suppose that if experimental conditions and data treatment are fixed, kB is the same for all particles (e and different ions). Below we will check this hypothesis on many examples where data existed.

3. Calculation of QFs for different scintillators Organic scintillators: C8H8 (polysterene, solid) C16H18 (PXE, liquid) C9H12 (pseudocumene, liquid) For C9H12, kB values in (c) and (d) are very different – not surprise (different conditions) In part d, kB is obtained by fitting data for protons; after this, curve for C ions is calculated [29] M. Bongrand, AIP Conf. Proc. 897 (2007) 14. [30] H.O. Back et al., NIMA 584 (2008) 98. [31] J. Hong et al., Astropart. Phys. 16 (2002) 333.

Crystal scintillators: CdWO4 [13] F.A. Danevich et al., PRC 67 (2003) 014310. [32] T. Fazzini et al., NIMA 410 (1998) 213. Once more, kB values in (a) and (b) are different for the same material due to different experimental conditions. In (b), kB value is obtained fitting data for protons; then, curve for  particles was calculated

Crystal scintillators: CaF2(Eu) [15] P. Belli et al., NPA 789 (2007) 15. [34] R. Hazama et al., NIMA 482 (2002) 297. [35] S. Umehara et al., PRC 78 (2008) 058501. Near the same kB value for data of [15] and [34, 35]. In (b), fit of data for F ions was used to draw curve for Ca ions (not so good agreement).

Crystal scintillators: PbWO4 [36] F.A. Danevich et al., NIMA A 556 (2006) 259.

Crystal scintillators: ZnWO4 [6] I. Bavykina et al., IEEE TNS 55 (2008) 1449. [38] F.A. Danevich et al., NIMA 544 (2005) 553. In (b), curves for O, Zn and W ions are calculated with kB value obtained by fitting data for  particles of [38]. Not good agreement with data [6] is explained by: (1) different temperatures (room T in [38] and 20 mK in [6]); (2) non-monoenergetic neutron source in [6], thus mixture of QFs for different energies and ions; (3) different data treatment.

Crystal scintillators: CaWO4 – 1 [14] Yu.G. Zdesenko et al., NIMA 538 (2005) 657.

Crystal scintillators: CaWO4 – 2 [40] Th. Jagemann et al., Astropart. Phys. 26 (2006) 269. In (a), kB was obtained from fit of data for O ions; then curves for Ca and W ions were calculated. Fig. 9b vs 9a demonstrates that total dE/dr is much more preferable in describing the QF behaviour.

Crystal scintillators: CaWO4 – 3 [39] G. Angloher et al., Astropart. Phys. 23 (2005) 325. [41] J. Ninkovic et al., NIMA 564 (2006) 567. In part (a), R’=1/R is shown: In (a), kB was obtained normalizing theoretical and experimental R’ values for protons; after this, R’ values for all other ions were calculated. Range of A and Z values: A=1, Z=1 for p, and A=197, Z=79 for Au. In (b) and (c), temperature is 7 mK; in (a) – room T (so, different kB). In (b), kB was obtained to reproduce R for 2.3 MeV  particle (A=4, Z=2). In (c), calculated curve with this kB is in agreement with point for 104 keV Pb ions (A=206, Z=82).

Crystal scintillators: CsI(Tl) [42] S. Pecourt et al., Astropart. Phys. 11 (1999) 457. [43] H. Park et al., NIMA 491 (2002) 460. [44] M.Z. Wang et al., PLB 536 (2002) 203. [45] T.Y. Kim et al., NIMA 500 (2003) 337. QF values for Cs and I ions are practically the same. Value of kB is the same for measurements by different groups (but could be just coincidence). kB for  particles is different in (d) but data were measured in different conditions.

Crystal scintillators: CsI(Na) [43] H. Park et al., NIMA 491 (2002) 460. In (a), QF for Cs (or I) ions are described. In (b), QF for  particles with kB=5.5e-3 is predicted.

Crystal scintillators: NaI(Tl) [8] H. Chagani et al., JINST 3 (2008) P06003. [47] D.R. Tovey et al., PLB 433 (1998) 150. [53] R. Bernabei et al., NIMA 592 (2008) 297. In (a), kB was obtained by describing data for Na ions and then used to calculate curve for I ions. In (c), kB is obtained by fitting data for  particles in LIBRA experiment. Predicted with this kB QFs for Na and I ions in (d) are much higher than those usually measured and used in NaI(Tl) dark matter experiments (very important prediction).

Crystal scintillators: CeF3 [54] P. Belli et al., NIMA 498 (2003) 352.

Liquid noble gases: LXe [56] R. Bernabei et al., PLB 436 (1998) 379. [57] V. Chepel et al., Astropart. Phys. 26 (2006) 58. [58] R. Bernabei et al., Eur. Phys. J. direct C 11 (2001) 1. [59] M. Tanaka et al., NIMA 457 (2001) 454. Experimental data are well described but with different kB values for different measurements.

Prediction of quenching factors for ions for some scintillators

4. Conclusions Semiempirical method of calculation of quenching factors is proposed, based on the Birks formula and calculation of total stopping powers for electrons and ions with the ESTAR and SRIM codes which are publicly available. There is only one free parameter in the approach – the Birks kB factor. It is not considered as some fundamental constant for a given scintillating material but as a variable which depends on conditions of measurements and data treatment. Hypothesis is used that, once conditions of measurements and data treatment are fixed, the kB value is the same for particles of different kinds. Thus, if kB was determined by fitting data for particles of one kind (e.g.  particles of few MeV from internal contamination), it can be used to calculate QFs for particles of another kind and for another energies of interest (e.g. low energy recoils after scattering of DM particles). The approach was checked on many examples with materials which, furthermore, have different mechanisms of scintillation (organic scintillators – solid C8H8, liquid C16H18, C9H12; crystal scintillators – pure CdWO4, PbWO4, ZnWO4, CaWO4, CeF3 and doped CaF2(Eu), CsI(Tl), CsI(Na), NaI(Tl); liquid noble gases).

(4) Quenching factors calculated in the present approach in general increase at low energies, and this encourages experimental searches for DM particles. (5) Estimations of quenching factors for nuclear recoils are given for some scintillators where experimental data are absent (CdWO4, PbWO4, CeF3, Bi4Ge3O12, LiF, ZnSe). (6) For the DAMA/LIBRA experiment, it was shown that, based on measured in DAMA/LIBRA QFs for  particles, QFs for Na and I ions should be ~2 higher than those typically used in NaI(Tl) DM experiments. It should shift down the “evidence spot” of the DAMA/LIBRA observations removing contradiction with other experiment which give only limits for WIMPs cross-sections.

Thank you for attention!

Non-linearity in the light-output: CdWO4 L.Bardelli et al., NIMA 569(2006)743 Calculated in proposed approach