Date of download: 10/5/2017 Copyright © ASME. All rights reserved. From: Field Test of Water-Steam Separators for Direct Steam Generation in Parabolic Troughs J. Sol. Energy Eng. 2007;130(1):011002-011002-6. doi:10.1115/1.2804619 Figure Legend: Schematic diagram of a cyclone separator (not to scale)
Date of download: 10/5/2017 Copyright © ASME. All rights reserved. From: Field Test of Water-Steam Separators for Direct Steam Generation in Parabolic Troughs J. Sol. Energy Eng. 2007;130(1):011002-011002-6. doi:10.1115/1.2804619 Figure Legend: Schematic diagram of a baffle separator
Date of download: 10/5/2017 Copyright © ASME. All rights reserved. From: Field Test of Water-Steam Separators for Direct Steam Generation in Parabolic Troughs J. Sol. Energy Eng. 2007;130(1):011002-011002-6. doi:10.1115/1.2804619 Figure Legend: Schematic setup of the DISS test facility with the used measuring points
Date of download: 10/5/2017 Copyright © ASME. All rights reserved. From: Field Test of Water-Steam Separators for Direct Steam Generation in Parabolic Troughs J. Sol. Energy Eng. 2007;130(1):011002-011002-6. doi:10.1115/1.2804619 Figure Legend: Measured temperatures along the superheating section for two different steady-state tests (Collectors 9–11 from l=600–700m)
Date of download: 10/5/2017 Copyright © ASME. All rights reserved. From: Field Test of Water-Steam Separators for Direct Steam Generation in Parabolic Troughs J. Sol. Energy Eng. 2007;130(1):011002-011002-6. doi:10.1115/1.2804619 Figure Legend: Maximum measurements accuracy for several measured separation efficiencies as a function of the inlet steam quality
Date of download: 10/5/2017 Copyright © ASME. All rights reserved. From: Field Test of Water-Steam Separators for Direct Steam Generation in Parabolic Troughs J. Sol. Energy Eng. 2007;130(1):011002-011002-6. doi:10.1115/1.2804619 Figure Legend: Measured pressure loss coefficient for the investigated separators as a function of the inlet steam quality
Date of download: 10/5/2017 Copyright © ASME. All rights reserved. From: Field Test of Water-Steam Separators for Direct Steam Generation in Parabolic Troughs J. Sol. Energy Eng. 2007;130(1):011002-011002-6. doi:10.1115/1.2804619 Figure Legend: Measured separation efficiency of the baffle separator for different operation pressures with error bars
Date of download: 10/5/2017 Copyright © ASME. All rights reserved. From: Field Test of Water-Steam Separators for Direct Steam Generation in Parabolic Troughs J. Sol. Energy Eng. 2007;130(1):011002-011002-6. doi:10.1115/1.2804619 Figure Legend: Measured separation efficiency of the baffle and the cyclone separator (to improve clarity the error bars are neglected in this plot)
Date of download: 10/5/2017 Copyright © ASME. All rights reserved. From: Field Test of Water-Steam Separators for Direct Steam Generation in Parabolic Troughs J. Sol. Energy Eng. 2007;130(1):011002-011002-6. doi:10.1115/1.2804619 Figure Legend: Measured evaporation length within the superheating section for the baffle and the cyclone separator