DALI Scene Controller HDL-MC-DALI.431.

Slides:



Advertisements
Similar presentations
Digital Adressable Lighting Interface (Basic information)
Advertisements

Show Controller——DMX Module 48 Channel——SB-DN-48DMX 512 Channel——SB-DN-512DMX Configuration of Show Control ler ( DMX Module ) 240 Channel——SB-DN-240DMX.
DLP LCD PANEL Programming
Version How to Use Packet Tracer MarinaMD.
SMS Module Model : SB-DN-SMS/IP Configuration of SMS Module.
Dimmer debugging Big dimmer ( hanging dimmer ) ◆ 12ch 10A professional Intelligent Dimmer ◆ 6ch 20A professional Intelligent Dimmer ◆ 6ch 10A professional.
Touch screen function manual Right & left scroll key Room selecting key, Maximal quantity 50. Controlling Target icon Room background image brightness.
User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View.
DMX Controller SB-DN-512DMX.
HDL-MGSM.431. Description MGSM.431 is an automation module based on GSM monitoring and controlling. Being at a great distance you can operate a target.
TOUCH Life SB-WL-TL7 SB-MBL-TS10-CE Windows XP. Touch screen function manual Click the icon 5 times to exit Room select key Room Function Icon function.
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
0-10V Ballast Dimmer HDL-MRDA HDL-MRDA channel 10A DC0 - 10V output module is a multifunction control module. It has 6 channel relay.
MRDA Wiring diagram S-BUS Module ID setting button ballast L N DC0-10V dimming voltage Control DC Maximum current :100mA 6 relay switch 16A 6 channel.
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
Solutions for Hotel HDL-MHRCU.431.
Chapter One : DALI100. Chapter Two : Parameter of DALI Input : 5V by USB ; Maximum Current 500mA ; Output : V ; Maximum Current 250mA ;
目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.
Start up: 1. Power off and insert a GSM card, power on and check the GSM signal on the LCD. 2. Use the LCD and keys on the module to check and set the.
6 CH 5A LED Dimmer HDL-MDLED /2/2016 Description HDL-MDLED CH 5A Intelligent LED Dimming Module, it can be used to control the LED.
System Important Points for Wiring
CMV-NET Chigo VRF Network Centralized Control System
G. Schlag / STO-GM / Novembre 2012
Gateway HDL-MBUS01IP.431.
DALI-Gateway DG/S 1.1.
ABB STOTZ-KONTAKT GmbH DALI-Gateway DG/S
DALI Scene Controller HDL-MC-DALI.431.
PV100&PV200 Solar Pumping VFD
STO/GM December 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX DGN/S DALI Gateway for emergency lighting © STO/G - Slide 1.
Room Controller RC/A 8.1 Room Controller economic flexible modular.
Multifunctional Sensor
ILife App.
automatic recognition of load-type superior functionality
SB-DN-Logic960 Logic module.
6 CH 5A LED Dimmer HDL-MDLED
SMS module HDL-MGSM.431.
TransTel Medical Nurse Call System TransTel Communications.
Basic router configuration
DALI-Gateway DG/S 8.1.
Eclipse EHX System Logic Maestro
Kevin Boyce Director of Product Management, LED Drivers
FLoor Heating Controller
Power meter SB-DN-PM1P03 SB-DN-PM3P02.
Dimmer 6fold 10V Actuator M/DA
Wireless Relay HDL-MPR01-RF.18.
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
Universal Interface, 4-fold, FM, US/U 4.2
DMX Controller SB-DN-48DMX.
Chapter One:DALI100 Output:DALI1,DALI2,without difference of positive and negative Input:connected to computer with USB Power Indicator Light DALI Commend.
FLoor Heating Controller
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Premium, RM/S 2.1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Basic, RM/S 1.1
Wireless 4 Buttons Touch Panel
IR Emitter module SB-IR-EM.
with UCM/KNX Rev Sept 2010 Ref: UCM/KNX Manual
DMX512 Gateway M/DMX512.1.
Wireless 3 Buttons Touch Panel
MOSFET Dimmer Actuator
Wireless Relay HDL-MPR02-RF.18.
© 2002, Cisco Systems, Inc. All rights reserved.
Curtain Actuator M/W
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
Curtain Motor HDL-MWM70B.12 HDL-MVSM45B.12.
Setup 1; Add iMCB. Set up : Please check circuit and follow proper wiring before power up.
ABB STOTZ-KONTAKT GmbH DALI-Light Controller DLR/S M
Universal Dim Actuator UD/S
Unity Application Generator
OWS + SureView Integration
The efficient interface for lighting control
Presentation transcript:

DALI Scene Controller HDL-MC-DALI.431

DALI Introduction HDL-MC-DALI.431 Functions: Gateway between HDL Buspro system and DALI Ballast Max. 64 channel DALI ballasts can be connected to this module With scene control Maximum 16 separate areas, supports area dimming Each area has 16 scenes and maximum scenes running time is 90.51s. HDL-MC-DALI.431

Wiring

DALI address\Patch Step1- Check that the DALI bus and Luminaires are working Use the 'All lights are flickering' setting to see that the DALI bus is connected to all the expected luminaires

DALI address\Patch Step2- Check and initialize the Patch Click on Patch and then initialize the patch - check that all numbers correlate all the way to 64channels. Channels in HDL directly correlate to Addresses in DALI

DALI address\Patch Step3- Address the DALI Devices If it is a new installation use “Initialization” to set all of the addresses, the DALI ballasts will be addressed randomly. When the addressing is finished you will see all the addresses in the blue section. Step4- Check the address of each device Use the option “The designated lights with DALi Address are flickering” to make each address flash. Go through every address one at a time and write on your floor layout to show which luminaire has which address.

Area Setup Step5- Configure Areas (Groups) Configure areas and add channels to your areas. Areas in HDL directly correlate to groups in DALi 1. Click ”area setup” Channels in the area 2. select current area 4. Channels waiting for assignment 5. Add channel to or delete channel from current area. 3. create area When you are configuring areas – after clicking on save you will actually send the group settings to the DALi ballasts

Channel Step6- Configure Channels Check and configure the settings for all channels. Intensity during system failure: DALI devices intensity after power on:

Scene Step7- Configure Scenes. 1. select area 2. input scene no., key in a start scene and end scene according to your needs 3. scene remark 4. scene setup

Scene Setup 3. set up each channel’s status 2. set up scene running time - the transient time before reaching the preset level. 4. save the scene 1. click the scene setup

Scene Restore Select a scene for scene restore when power on.

DALI Status This tab shows the status of each ballast which is connected to the DALI. a) Ballast status: this is to check the status of the ballast whether it works normal or not b) Load status: this displays the status of the loads (lights) which is connected to the ballast whether it works fine or in fault. c) Lights ON/OFF: whether the lights are on or off d) In the range of brightness: this function is useless for now. e) Dimming: when you send dimming command to specific ballast, this shows whether the dimming process is complete or not

Controlling Step8- Controlling You can control the DALi devices using any of the standard HDL commands: Single Channel Command to set a single DALi device Scene Command to set a Group to a specific scene The DALI64 supports direct DALi group control. By using HDL single channel commands you can set or dim a whole Area / Group of ballasts. To directly control a whole area or group use channels 65 to 80, these are mapped to the DALi Groups 0 to 15

Emergency or Fire Mode Emergency or Fire Mode The function of this mode is: 1. Set all ballast on a per area basis to 100% when there is an emergency – for example used in a hospital when there is a fire alarm to assist with evacuation. 2. When the fire alarm is cleared each ballast returns to the setting it had before the emergency. Universal switches are used to set the emergency mode on or off on an area by area basis.

Emergency or Fire Mode For example: Area 1 contains channels 1, 2, 7 and 8 Area 2 contains channels 3, 4, 5 and 20 Current settings are: 1- 80%, 2 - 100%, 7 - 0%, 8 - 80%; 3 - 45%, 4 - 80%, 5 - 100%, 20 - 100%. Set universal switch 1 “on” (makes Area 1 go to emergency mode) 1, 2, 7 and 8 all go to 100% 3, 4, 5 and 20 do not change Set universal switch 1 “off” (makes Area 1 return to previous settings) Channels in area 1 go to Channels in area 2: