10 12 and 14 TR Advanced Glycol Chiller

Slides:



Advertisements
Similar presentations
Water Source Heat Pump Systems
Advertisements

1 Kraft Fuels LPG Products & Services Your Logo Here Franz Keiling An Overview about LPG Dispensers and Technology Franz Keiling An Overview about LPG.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
APTA Media Presentation Mini-Hybrid & Power 450
Trane Variable Water Flow System
Perform Control Test. Check for Consistent Liquid Temperatures Entering and Leaving Liquid Temperatures should be close when the water pumps are on but.
Variable Frequency Drives VFD Basics
Johnson Controls1 YORK Model YVAA Air-Cooled Chillers Variable Speed Screw, tons.
CNG Refuelling station. A company located in Cherasco (Italy), is among the world leaders in the field of designing and manufacturing of components and.
Upon completion of this training one should be able to: Identify different types of hydronic heating systems Identify key components in a simple hydronic.
Bi Fuel Automotive Technologies Who we Are Fyda Energy Solutions is in a partnership with Prins and American Alternative Fuel bringing practical Alternative.
Engineer Presentation
PORTABLE GENERATOR Dimensions: 25.88” x 21.13” x 24.75” Weight: 147 lbs. UPC: *AS RATED BY ENGINE MANUFACTURER MODEL: PM ©2007 POWERMATE.
ASHRAE Presentation: VRF Overview Mitsubishi Electric Presenter: Phone number ©2011 Mitsubishi Electric& Electronics USA, Inc.
Product Introduction.
44 th Annual Conference & Technical Exhibition By Thomas Hartman, P.E. The Hartman Company Georgetown, Texas Sustainable Chilled Water.
Equipment Installation, piping & wiring Variable Water Flow System.
For more information, please contact 19/11/2010 EN/CV/DC Chiller design and purchase by Elena Perez Rodriguez.
High Density Cooling Air conditioning for high density applications
1 Multi-use Facility. 2 Occupancy – 140 persons Building Characteristics Single story 20,000 square feet (250’ x 80’) Standard construction.
Grundfos FLOW THINKING Air conditioning the Grundfos Way.
Perfect solution for large building
Air conditioning – Refreshes your life Mini-Chiller Applied Systems Sales1 EWA(Y)Q-AAV3P Residential Mini-Chiller Heating EWAQ - AA3VP EWYQ - AAV3P Cooling.
Hawke’s Bay Refrigeration
Heliocentris Commercial Confidential 1 Integration of Industrial Fuel Cells in Technical Applications Using the NEXA ® Training System Dr. Claus Fischer.
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
Flooded Screw Chiller FWSF Electronic Expansion Valve Condenser Evaporator Control box compressor Flooded Screw Chiller - FWSF.
1. Footer Date SpiralAIR Product Introduction People. Passion. Performance.
November 2004 Low Hanging Fruit Low Cost Energy Efficiency Opportunities in Cleanrooms.
WILO MVI Vertical Multi-Stage Pumps Multi-Stage Pumps for Commercial, Municipal and Industrial Applications Presentation Date – Revised Sept 2006.
CPPM Pixel Evaporative Cooling Plant Description & Operation with C 3 F 8 or C 4 F 10 G. Hallewell, CPPM, Feb 07, 2005.
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Second Nature ® Compact Chiller Leading the way in secondary coolant refrigeration systems. SNCC.
For more information, please contact 14/12/2010 EN/CV/DC Technical specification IT-3684 by Elena Perez Rodriguez.
THE SUSTAINABLE COMPANY Development of entrepreneurship in vocational education Leonardo Project Second Meeting Tenerife – February 2013 Spanish team presentation.
SYSTEMS. Pumps Systems Our systems are identified as follows Example: model D-CPS-HT-1000-VFD Dis for Duplex units CPSis for Constant Pressure System.
1  2008 Kaeser Compressors, Inc., USA (V2.2) “Specifications are subject to change without notice” Presenting... Kaeser Omega Blowers.
Sigma Rotary Screw Compressors
2016 Chiller New Products Presentation.
TYPE “HOS” 6” Stroke Compressor & Ancillary Equipment
Replacing hydride bed with bottle Advantages No risk of diminished bed capacity Following jobs no longer necessary – Move pressure gauge – Replace cracked.
WELCOME. Glycol Refrigeration A most basic definition of refrigeration is taking heat from someplace we don’t want it and moving it to someplace where.
Integrated Blower Packages Kaeser Integrated Blower Family.
James McIntyre VRF Training Manager V5 Key Components.
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
It’s…….
Hydraulic Trainer
Exhaust Heat Recovery Systems
Chicago Pneumatic Compressors Company Presentation
Design, Evaluation and Application of a Fuel Cell Vehicle
Compact line ‘EW*D~J-’ water-cooled chiller range
Advisor: Dr. Shangchao Lin
Sustainability Best Practices
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
GEYSER Heat Pump Water Heater
LCLS-II 2K Cold Box Controls Design Review
© Copyright, HQT-SV Control System
Presented By: Jim Lombardo Herbert & Conway, Inc.
Course PEF3006 Process Control Fall 2017 Actuators By Finn Haugen
10TR Nominal Glycol Chiller
SHANGHAI ROTORCOMP COMPRESSOR ONLY USE.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Dunham Bush Air Cooled Package
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
Champion RotorChamp HP
Champion RotorChamp HP
NRL NRL - Welcome to the NRK Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
Presentation transcript:

10 12 and 14 TR Advanced Glycol Chiller

FEATURES AND BENEFITS PLUG AND PLAY OPERATION Single point power connection for system. System available in 230 VAC or 460 VAC (60 Hz) Steel skid construction for easy transportation to final site of operation System delivered tested, charged, and programmed with Fluid Industrial Manufacturing proprietary controls paradigm PROPRIETARY CONTROLS PARADIGM Controls software designed by Fluid Industrial Manufacturing in house engineering to ensure optimal temperature accuracy and precision over time System controls designed for system safety and reliability: high / low pressure switches, fluid flow switches, current transmitters, equal run time sequencers (where applicable), PID temperature control, and more all included on base models SERVICEABILITY AND RELIABILITY 12 month (365 day) warranty from ship date – with extended warranties available System designed for serviceability – all electrical panels, compressors, and pump motors are readily accessible by trained technicians and situated for easy replacement should it be required Safety systems ensure proper operation at all times to maximize system life span and minimize down time CONFORMANCE AND REGULATIONS UL Listed and approved system Conforms with all California Title 24 and CalGreen Requirements and Voluntary Limitations. Fluid Industrial Manufacturing 280 Digital Drive, Morgan Hill, California 95037

FEATURES AND BENEFITS OPTIMIZED SYSTEM EFFICIENCY Designed to meet – and drastically exceed – all efficiency and configuration requirements for the state of California STANDARD EER ACCORDING TO AHRI 550/590 10 TON SYSTEM 12 TON SYSTEM 14 TON SYSTEM EER 10.756 Btu/W 10.901 Btu/W 10.745 Btu/W STANDARD AND OPTIONAL FEATURES STANDARD FEATURES Programmable PLC Controller Outgoing Temp Control 50 Gallon Buffer Tank Current Transmitters Single Compressor Circuit Single Circulation Pump Factory Tuned and Tested Diagnostic Display Micro Channel Condensers Fully Enclosed by Metallic Skins Tube Frame Construction EER Above 10.5 Low Ambient Operability Variable Speed Condensing Fan High / Low Pressure Safeties UL Listed OPTIONAL FEATURES Electronic Hot Gas Bypass System Variable Speed Compressor (VFD) Dual Compressor Circuits for Redundancy Two Pump System (Primary and Secondary Pump) Isolation Ball Valves Low Temperature Control (Sub 0C Fluid) Fluid Industrial Manufacturing 280 Digital Drive, Morgan Hill, California 95037

TECHNICAL SPECIFICATIONS FIGURE 1: 3HP System Circulation Pump Curve TABLE 1: Approximate Compressor Thermal Capacity – 10TR (BTU/hr) Coolant (Glycol) Temperature [°F] Ambient Temperature [°F] [30] [35] [40] [45] [50] [55] [75] 94,800 105,000 116,000 127,800 140,600 154,300 [85] 89,200 98,800 109,300 120,500 132,600 145,600 [95] 83,500 92,600 102,500 113,100 124,600 136,900 [105] 77,600 86,200 95,500 105,600 116,400 128,000 [115] 74,500 82,900 91,900 101,600 112,100 123,400 Fluid Industrial Manufacturing 280 Digital Drive, Morgan Hill, California 95037

TECHNICAL SPECIFICATIONS TABLE 2: Approximate Compressor Thermal Capacity – 12TR (BTU/hr) Coolant (Glycol) Temperature [°F] Ambient Temperature [°F] [30] [35] [40] [45] [50] [55] [75] 105,300 116,700 128,900 142,100 156,300 171,500 [85] 99,100 109,800 121,400 133,900 147,400 161,800 [95] 92,700 102,900 113,800 125,700 138,400 152,100 [105] 86,100 95,700 106,000 117,100 129,200 [115] 79,000 88,000 97,700 108,200 119,500 131,600 TABLE 3: Approximate Compressor Thermal Capacity – 14TR (BTU/hr) Coolant (Glycol) Temperature [°F] Ambient Temperature [°F] [30] [35] [40] [45] [50] [55] [75] 139,200 154,300 170,500 187,900 207,000 227,000 [85] 130,800 145,200 160,700 177,400 195,300 214,000 [95] 121,700 135,600 150,400 166,300 183,300 202,000 [105] 112,100 125,300 139,500 154,600 170,700 188,000 [115] 101,900 114,600 128,000 142,300 157,500 173,700 Fluid Industrial Manufacturing 280 Digital Drive, Morgan Hill, California 95037

DIMENSIONS AND WEIGHTS Approximate Operating Weight: TBD Pounds FIGURE 2: System top view dimensions (inches) FIGURE 3: System front view dimensions (inches) Approximate Operating Weight: TBD Pounds Fluid Industrial Manufacturing 280 Digital Drive, Morgan Hill, California 95037